MCC 1N4933GP

MCC
Features
•
•
•
•
•
1 Amp Glass
Passivated Fast
Recovery Rectifier
50 - 600 Volts
Glass Passivated Junction
Low Leakage Current
Metalurgically Bonded Construction
Low Cost
Fast Switching
Maximum Ratings
•
•
•
1N4933GP
THRU
1N4937GP
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
DO-41
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 30 °C/W Junction To Lead
MCC
Catalog
Number
Device
Marking
1N4933
1N4934
1N4935
1N4936
1N4937
-----------
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
35V
70V
140V
280V
420V
50V
100V
200V
400V
600V
D
A
Cathode
Mark
B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
Typical Junction
Capacitance
IF(AV)
1.0A
TA =55°C
IFSM
30A
8.3ms, half sine
VF
1.3V
IFM = 1.0A;
TJ = 25°C*
IR
5.0µA
100µA
TJ = 25°C
TJ = 125°C
C
Trr
200ns
CJ
15pF
IF=0.5A,
IR=1.0A,
Irr=0.25A
Measured at
IF=1.0A
VR=30V
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.166
.080
.028
1.000
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
www.mccsemi.com
MAX
.205
.107
.034
---
MM
MIN
4.10
2.00
.70
25.40
MAX
5.20
2.70
.90
---
NOTE
MCC
1N4933GP thru 1N4937GP
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
1.2
6
4
1.0
2
Amps
.8
1
.6
.6
Amps
.4
.4
.2
25°C
.2
.1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.06
0
.04
0
50
75
100
125
150
175
°C
.02
.01
.4
.6
.8
1.0
1.2
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
100
60
40
20
pF
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
1N4933GP thru 1N4937GP
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
100
60
60
40
50
20
40
10
30
6
Amps
4 T =100°C
A
20
10
5
0
2
µAmps 1
.6
1
2
4
6
8 10
40
60 80 100
Cycles
.4
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.2
.1
20
TA=25°C
.06
.04
.02
.01
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
www.mccsemi.com