MCC UPS140

MCC
UPS120
THRU
UPS140
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
•
High Power Surface Mount Package
Guard Ring Protection
Low Forward Voltage
Integral Heat Sink/Locking Tabs
Compatible with Automatic Insertion Equipment
1 Amp Schottky
Rectifier
20 to 40 Volts
Maximum Ratings
•
•
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 23°C/W Junction To Tab
Maximum Thermal Resistance; 10°C/W Junction To Bottom
MCC
Device
Maximum
Maximum Maximum
Catalog
Marking
Recurrent
RMS
DC
Number
Peak Reverse
Voltage
Blocking
Voltage
Voltage
UPS120
BCF
20V
14V
20V
UPS130
BCG
30V
21V
30V
UPS140
BCJ
40V
28V
40V
DO-216AA
( POWERMITE
)
A
G
E
TAB 1 CATHODE
IF(AV)
1.0A
TJ = 135°C
IFSM
50A
8.3ms, half sine
H
J
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
UPS120
UPS130
UPS140
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage UPS120
UPS130
UPS140
TAB 2 ANODE
C
K
D
B
F
L
DIMENSIONS
VF
IR
.45 V
.55 V
.55 V
IFM = 1.0A;
TJ = 25°C*
TJ = 25°C
TJ = 85°C
.40/25mA VR = 20V
.41/11mA VR = 30 V
.50/25mA VR = 40 V
INCHES
DIM
A
B
C
D
E
F
G
H
J
K
L
MIN
.143
.070
.070
.087
.029
.051
----.035
.021
---------
MM
MAX
.153
.080
.080
.097
.039
.061
.026
.045
.031
.025
.006
*Pulse test: Pulse width 200 µsec, Duty cycle 2%
NOTE: POWERMITE package is patental by microsemi corp.
www.mccsemi.com
MIN
3.63
1.78
1.78
2.21
0.74
1.30
----0.89
0.53
---------
MAX
3.89
2.03
2.03
2.46
0.99
1.55
0.66
1.14
0.79
0.64
0.15
NOTE
MCC
UPS120 thru UPS140
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
1.2
6
4
1.0
2
.8
25°C
Amps
1
.6
.6
Amps
.4
.4
.2
.2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.1
.06
0
.04
25
50
75
100
125
150
°C
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
.02
.01
0
.2
.4
.6
.8
1.0
1.2
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
100
60
40
20
pF
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.mccsemi.com
400
1000
MCC
UPS120 thru UPS140
Figure 4
Peak Forward Surge Current
50
40
30
20
Amps
10
5
0
1
2
4
6
8 10
20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Oscilloscope
Note 1
-0.25
-1.0
1cm
Set Time Base for 20/100ns/cm
www.mccsemi.com