MITSUBISHI M2S28D30ATP

MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
PRELIMINARY
Some of contents are subject to change without notice.
DESCRIPTION
M2S28D20ATP is a 4-bank x 8388608-word x 4-bit,
M2S28D30ATP is a 4-bank x 4194304-word x 8-bit,
M2S28D40ATP is a 4-bank x 2097152-word x 16-bit,
double data rate synchronous DRAM, with SSTL_2 interface. All control and address signals are
referenced to the rising edge of CLK. Input data is registered on both edges of data strobe, and output
data and data strobe are referenced on both edges of CLK. The M2S28D20/30/40ATP achieves very
high speed data rate up to 133MHz, and are suitable for main memory in computer systems.
FEATURES
- Vdd=Vddq=2.5V+0.2V
- Double data rate architecture;
two data transfers per clock cycle
- Bidirectional, data strobe (DQS) is transmitted/received with data
- Differential clock inputs (CLK and /CLK)
- DLL aligns DQ and DQS transitions
with CLK transitions edges of DQS
- Commands entered on each positive CLK edge;
- data and data mask referenced to both edges of DQS
- 4 bank operation controlled by BA0, BA1 (Bank Address)
- /CAS latency- 2.0/2.5 (programmable)
- Burst length- 2/4/8 (programmable)
- Burst type- sequential / interleave (programmable)
- Auto precharge / All bank precharge controlled by A10
- 4096 refresh cycles /64ms (4 banks concurrent refresh)
- Auto refresh and Self refresh
- Row address A0-11 / Column address A0-9,11(x4)/ A0-9(x8)/ A0-8(x16)
- SSTL_2 Interface
- 400-mil, 66-pin Thin Small Outline Package (TSOP II)
- FET switch control(/QFC) for x4/ x8
- JEDEC standard
MITSUBISHI ELECTRIC
1
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
PIN CONFIGURATION(TOP VIEW)
x4
x8
x16
VDD
NC
VDDQ
NC
DQ0
VSSQ
NC
NC
VDDQ
NC
DQ1
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NU,/QFC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
VDD
DQ0
VDDQ
NC
DQ1
VSSQ
NC
DQ2
VDDQ
NC
DQ3
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NU,/QFC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
CLK,/CLK
CKE
/CS
/RAS
/CAS
/WE
DQ0-7
DQS
DM
/QFC
Vref
VDD
DQ0
VDDQ
DQ1
DQ2
VSSQ
DQ3
DQ4
VDDQ
DQ5
DQ6
VSSQ
DQ7
NC
VDDQ
LDQS
NC
VDD
NC
LDM
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
66pin TSOP(II)
400mil width
x
875mil length
0.65mm
Lead Pitch
ROW
A0-11
Column
A0-9,11(x4)
A0-9 (x8)
A0-8 (x16)
: Master Clock
: Clock Enable
: Chip Select
: Row Address Strobe
: Column Address Strobe
: Write Enable
: Data I/O
: Data Strobe
: Write Mask
: FET Switch Control for x4/x8
: Reference Voltage
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
A0-11
BA0,1
Vdd
VddQ
Vss
VssQ
MITSUBISHI ELECTRIC
VSS
DQ15
VSSQ
DQ14
DQ13
VDDQ
DQ12
DQ11
VSSQ
DQ10
DQ9
VDDQ
DQ8
NC
VSSQ
UDQS
NC
VREF
VSS
UDM
/CLK
CLK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
VSS
VSS
DQ7
VSSQ
NC
DQ6
VDDQ
NC
DQ5
VSSQ
NC
DQ4
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CLK
CLK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
VSS
VSS
NC
VSSQ
NC
DQ3
VDDQ
NC
NC
VSSQ
NC
DQ2
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CLK
CLK
CKE
NC
NC
A11
A9
A8
A7
A6
A5
A4
VSS
: Address Input
: Bank Address Input
: Power Supply
: Power Supply for Output
: Ground
: Ground for Output
2
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
BLOCK DIAGRAM
DLL
Memory
Array
Bank #0
DQ0 - 15
/QFC for x4/x8 UDQS,LDQS
I/O Buffer
QFC&QS Buffer
Memory
Array
Bank #1
Memory
Array
Bank #2
Memory
Array
Bank #3
Mode Register
Control Circuitry
Address Buffer
Control Signal Buffer
Clock Buffer
A0-11
/CS /RAS /CAS /WE
BA0,1
CLK, /CLK CKE
Type Designation Code
UDM,
LDM
This rule is applied to only Synchronous DRAM family.
M 2 S 28 D 3 0 A TP -75
Speed Grade 10: 125MHz@CL=2.5,100MHz@CL=2.0
75: 133MHz@CL=2.5,100MHz@CL=2.0
Package Type TP: TSOP(II)
Process Generation
Function Reserved for Future Use
Organization 2 n 2: x4, 3: x8, 4: x16
DDR Synchronous DRAM
Density 28: 128M bits
Interface V:LVTTL, S:SSTL_3, _2
Memory Style (DRAM)
Mitsubishi Main Designation
MITSUBISHI ELECTRIC
3
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
PIN FUNCTION
SYMBOL
TYPE
DESCRIPTION
Input
Clock: CLK and /CLK are differential clock inputs. All address and
control input signals are sampled on the crossing of the positive edge
of CLK and negative edge of /CLK. Output (read) data is referenced to
the crossings of CLK and /CLK (both directions of crossing).
CKE
Input
Clock Enable: CKE controls internal clock. When CKE is low, internal
clock for the following cycle is ceased. CKE is also used to select auto /
self refresh. After self refresh mode is started, CKE becomes
asynchronous input. Self refresh is maintained as long as CKE is low.
/CS
Input
Chip Select: When /CS is high, any command means No Operation.
/RAS, /CAS, /WE
Input
Combination of /RAS, /CAS, /WE defines basic commands.
A0-11
Input
A0-11 specify the Row / Column Address in conjunction with BA0,1.
The Row Address is specified by A0-11. The Column Address is
specified by A0-9,11(x4), A0-9(x8) and A0-8(x16). A10 is also used to
indicate precharge option. When A10 is high at a read / write
command, an auto precharge is performed. When A10 is high at a
precharge command, all banks are precharged.
BA0,1
Input
Bank Address: BA0,1 specifies one of four banks to which a command is
applied. BA0,1 must be set with ACT, PRE, READ, WRITE commands.
CLK, /CLK
DQ0-15(x16),
DQ0-7(x8),
DQ0-3(x4),
Input / Output
Data Input/Output: Data bus
DQS
Input / Output
Data Strobe: Output with read data, input with write data. Edgealigned with read data, centered in write data. Used to capture write
data. For the x16, LDQS corresponds to the data on DQ0-DQ7; UDQS
correspond to the data on DQ8-DQ15
/QFC
Output
DM
Input
FET Control: Optional. Output during every Read and Write access. Can
be used to control isolation switches on modules. Open drain output.
Input Data Mask: DM is an input mask signal for write data. Input data
is masked when DM is sampled HIGH along with that input data
during a WRITE access. DM is sampled on both edges of DQS.
Although DM pins are input only, the DM loading matches the DQ
and DQS loading. For the x16, LDM corresponds to the data on DQ0DQ7; UDM corresponds to the data on DQ8-DQ15.
Vdd, Vss
Power Supply
Power Supply for the memory array and peripheral circuitry.
VddQ, VssQ
Power Supply
VddQ and VssQ are supplied to the Output Buffers only.
Vref
Input
SSTL_2 reference voltage.
MITSUBISHI ELECTRIC
4
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
BASIC FUNCTIONS
The M2S28D20/30/40ATP provides basic functions, bank (row) activate, burst read / write, bank
(row) precharge, and auto / self refresh. Each command is defined by control signals of /RAS,
/CAS and /WE at CLK rising edge. In addition to 3 signals, /CS ,CKE and A10 are used as chip
select, refresh option, and precharge option, respectively. To know the detailed definition of
commands, please see the command truth table.
/CLK
CLK
/CS
Chip Select : L=select, H=deselect
/RAS
Command
/CAS
Command
/WE
Command
CKE
Refresh Option @refresh command
A10
Precharge Option @precharge or read/write command
define basic commands
Activate (ACT) [/RAS =L, /CAS =/WE =H]
ACT command activates a row in an idle bank indicated by BA.
Read (READ) [/RAS =H, /CAS =L, /WE =H]
READ command starts burst read from the active bank indicated by BA. First output data appears after
/CAS latency. When A10 =H at this command, the bank is deactivated after the burst read (autoprecharge, READA)
Write (WRITE) [/RAS =H, /CAS =/WE =L]
WRITE command starts burst write to the active bank indicated by BA. Total data length to be written
is set by burst length. When A10 =H at this command, the bank is deactivated after the burst write
(auto-precharge, WRITEA)
.
Precharge (PRE) [/RAS =L, /CAS =H, /WE =L]
PRE command deactivates the active bank indicated by BA. This command also terminates burst read
/write operation. When A10 =H at this command, all banks are deactivated (precharge all, PREA ).
Auto-Refresh (REFA) [/RAS =/CAS =L, /WE =CKE =H]
REFA command starts auto-refresh cycle. Refresh address including bank address are generated
internally. After this command, the banks are precharged automatically.
MITSUBISHI ELECTRIC
5
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
COMMAND TRUTH TABLE
MNEMONIC
CKE
n-1
CKE
n
/CS
/RAS
/CAS
/WE
BA0,1
A10
/AP
Deselect
DESEL
H
X
H
X
X
X
X
X
X
No Operation
NOP
H
X
L
H
H
H
X
X
X
Row Address Entry &
Bank Activate
ACT
H
H
L
L
H
H
V
V
V
Single Bank Precharge
PRE
H
H
L
L
H
L
V
L
X
PREA
H
H
L
L
H
L
X
H
X
Column Address Entry
& Write
WRITE
H
H
L
H
L
L
V
L
V
Column Address Entry
& Write with
Auto-Precharge
WRITEA
H
H
L
H
L
L
V
H
V
Column Address Entry
& Read
READ
H
H
L
H
L
H
V
L
V
Column Address Entry
& Read with
Auto-Precharge
READA
H
H
L
H
L
H
V
H
V
Auto-Refresh
REFA
H
H
L
L
L
H
X
X
X
Self-Refresh Entry
REFS
H
L
L
L
L
H
X
X
X
L
H
H
X
X
X
X
X
X
Self-Refresh Exit
REFSX
L
H
L
H
H
H
X
X
X
Burst Terminate
TERM
H
H
L
H
H
L
X
X
X
1
Mode Register Set
MRS
H
H
L
L
L
L
L
L
V
2
COMMAND
Precharge All Banks
A0-9,
note
11
H=High Level, L=Low Level, V=Valid, X=Don't Care, n=CLK cycle number
NOTE:
1. Applies only to read bursts with autoprecharge disabled; this command is undefined (and should not be used) for
read bursts with autoprecharge enabled, and for write bursts.
2. BA0-BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0=1 ,
BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A11 provide the
op-code to be written to the selected Mode Register.
MITSUBISHI ELECTRIC
6
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
FUNCTION TRUTH TABLE
Current State
IDLE
ROW ACTIVE
READ(AutoPrecharge
Disabled)
/CS /RAS /CAS /WE Address
H
X
X
X X
L
H
H
H X
L
L
L
L
L
H
H
L
L
L
H
L
H
H
L
L
L
L
H
X
L
L
H
H
L
L
X
H
L
H
Command
DESEL
NOP
Action
NOP
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
ILLEGAL
ILLEGAL
Bank Active, Latch RA
NOP
Auto-Refresh
4
5
5
MRS
Mode Register Set
X
BA
BA, CA, A10
BA, RA
BA, A10
X
Op-Code, ModeL
Add
X X
DESEL
NOP
H
H
H X
L BA
NOP
TERM
H
L
H BA, CA, A10
READ / READA
L
H
L
L
WRITE / WRITEA
L
L
L
L
L
L
H
H
L
ACT
PRE / PREA
REFA
L
L
L
MRS
ILLEGAL
H
X
X
H BA, RA
L BA, A10
H X
Op-Code, ModeL
Add
X X
NOP
NOP
Begin Read, Latch CA, Determine
Auto-Precharge
Begin Write, Latch CA, Determine
Auto-Precharge
Bank Active / ILLEGAL
Precharge / Precharge All
ILLEGAL
DESEL
NOP (Continue Burst to END)
L
L
H
H
H
H
H X
L BA
NOP
TERM
L
H
L
H BA, CA, A10
READ / READA
L
H
L
L
WRITE / WRITEA
NOP (Continue Burst to END)
Terminate Burst
Terminate Burst, Latch CA, Begin
New Read, Determine AutoPrecharge
ILLEGAL
L
L
L
L
L
L
H
H
L
ACT
PRE / PREA
REFA
Bank Active / ILLEGAL
Terminate Burst, Precharge
ILLEGAL
L
L
L
H BA, RA
L BA, A10
H X
Op-Code, ModeL
Add
MRS
ILLEGAL
BA, CA, A10
BA, CA, A10
MITSUBISHI ELECTRIC
Notes
2
2
2
3
2
7
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
FUNCTION TRUTH TABLE (continued)
Current State
WRITE(AutoPrecharge
Disabled)
READ with
Auto-Precharge
WRITE with
Auto-Precharge
/CS /RAS /CAS /WE Address
H
X
X
X X
Command
DESEL
Action
NOP (Continue Burst to END)
ACT
PRE / PREA
REFA
NOP (Continue Burst to END)
ILLEGAL
Terminate Burst, Latch CA, Begin
Read, Determine Auto-Precharge
Terminate Burst, Latch CA, Begin
Write, Determine Auto-Precharge
Bank Active / ILLEGAL
Terminate Burst, Precharge
ILLEGAL
MRS
ILLEGAL
DESEL
NOP
TERM
READ / READA
WRITE / WRITEA
ACT
PRE / PREA
REFA
NOP (Continue Burst to END)
NOP (Continue Burst to END)
ILLEGAL
ILLEGAL
ILLEGAL
Bank Active / ILLEGAL
Precharge / ILLEGAL
ILLEGAL
MRS
ILLEGAL
DESEL
NOP
TERM
READ / READA
WRITE / WRITEA
ACT
PRE / PREA
REFA
NOP (Continue Burst to END)
NOP (Continue Burst to END)
ILLEGAL
ILLEGAL
ILLEGAL
Bank Active / ILLEGAL
Precharge / ILLEGAL
ILLEGAL
MRS
ILLEGAL
L
L
H
H
H
H
H X
L BA
NOP
TERM
L
H
L
H BA, CA, A10
READ / READA
L
H
L
L
WRITE / WRITEA
L
L
L
L
L
L
H
H
L
L
L
L
H
L
L
L
L
L
L
L
X
H
H
H
H
L
L
L
X
H
H
L
L
H
H
L
L
L
L
H
L
L
L
L
L
L
L
X
H
H
H
H
L
L
L
X
H
H
L
L
H
H
L
L
L
L
H BA, RA
L BA, A10
H X
Op-Code, ModeL
Add
X X
H X
L BA
H BA, CA, A10
L BA, CA, A10
H BA, RA
L BA, A10
H X
Op-Code, ModeL
Add
X X
H X
L BA
H BA, CA, A10
L BA, CA, A10
H BA, RA
L BA, A10
H X
Op-Code, ModeL
Add
BA, CA, A10
MITSUBISHI ELECTRIC
Notes
3
3
2
2
2
2
2
8
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
FUNCTION TRUTH TABLE (continued)
Current State
PRECHARGING
/CS /RAS /CAS /WE Address
H
X
X
X X
L
H
H
H X
L
H
H
L BA
L
H
L
X BA, CA, A10
L
L
H
H BA, RA
L
L
H
L BA, A10
L
L
L
H X
Op-Code, ModeL
L
L
L
Add
H
X
X
X X
ROW
L
H
H
H X
ACTIVATING
L
H
H
L BA
L
H
L
X BA, CA, A10
L
L
H
H BA, RA
L
L
H
L BA, A10
L
L
L
H X
Op-Code, ModeL
L
L
L
Add
H
X
X
X X
WRITE REL
H
H
H X
COVERING
L
H
H
L BA
L
H
L
X BA, CA, A10
L
L
H
H BA, RA
L
L
H
L BA, A10
L
L
L
H X
Op-Code, ModeL
L
L
L
Add
Command
DESEL
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
Action
NOP (Idle after tRP)
NOP (Idle after tRP)
ILLEGAL
ILLEGAL
ILLEGAL
NOP (Idle after tRP)
ILLEGAL
MRS
ILLEGAL
DESEL
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
NOP (Row Active after tRCD)
NOP (Row Active after tRCD)
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
MRS
ILLEGAL
DESEL
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
NOP
NOP
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
MRS
ILLEGAL
MITSUBISHI ELECTRIC
Notes
2
2
2
4
2
2
2
2
2
2
2
2
9
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
FUNCTION TRUTH TABLE (continued)
Current State /CS /RAS /CAS /WE Address
REFRESHING H
X
X
X X
MODE
REGISTER
SETTING
L
L
L
L
L
L
H
H
H
L
L
L
H
H
L
H
H
L
H
L
X
H
L
H
L
L
L
L
H
L
L
L
L
L
L
X
H
H
H
L
L
L
X
H
H
L
H
H
L
X
H
L
X
H
L
H
L
L
L
L
X
BA
BA, CA, A10
BA, RA
BA, A10
X
Op-Code, ModeAdd
X
X
BA
BA, CA, A10
BA, RA
BA, A10
X
Op-Code, ModeAdd
Command
DESEL
Action
NOP (Idle after tRC)
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
NOP (Idle after tRC)
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
MRS
ILLEGAL
DESEL
NOP
TERM
READ / WRITE
ACT
PRE / PREA
REFA
NOP (Row Active after tRSC)
NOP (Row Active after tRSC)
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
ILLEGAL
MRS
ILLEGAL
Notes
ABBREVIATIONS:
H=High Level, L=Low Level, X=Don't Care
BA=Bank Address, RA=Row Address, CA=Column Address, NOP=No Operation
NOTES:
1. All entries assume that CKE was High during the preceding clock cycle and the current clock cycle.
2. ILLEGAL to bank in specified state; function may be legal in the bank indicated by BA, depending on the state of
that bank.
3. Must satisfy bus contention, bus turn around, write recovery requirements.
4. NOP to bank precharging or in idle state. May precharge bank indicated by BA.
5. ILLEGAL if any bank is not idle.
ILLEGAL = Device operation and/or data-integrity are not guaranteed.
MITSUBISHI ELECTRIC
10
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
FUNCTION TRUTH TABLE for CKE
Current State
SELFREFRESHING
POWER
DOWN
ALL BANKS
IDLE
ANY STATE
other than listed
above
CKE n-1
CKE n
/CS
/RAS
/CAS
/WE
Address
Action
Notes
H
X
X
X
X
X
X
INVALID
1
L
H
H
X
X
X
X
Exit Self-Refresh (Idle after tRC)
1
L
H
L
H
H
H
X
Exit Self-Refresh (Idle after tRC)
1
L
H
L
H
H
L
X
ILLEGAL
1
L
H
L
H
L
X
X
ILLEGAL
1
L
H
L
L
X
X
X
ILLEGAL
1
L
L
X
X
X
X
X
NOP (Maintain Self-Refresh)
1
H
X
X
X
X
X
X
INVALID
L
H
X
X
X
X
X
Exit Power Down to Idle
L
L
X
X
X
X
X
NOP (Maintain Self-Refresh)
H
H
X
X
X
X
X
Refer to Function Truth Table
2
H
L
L
L
L
H
X
Enter Self-Refresh
2
H
L
H
X
X
X
X
Enter Power Down
2
H
L
L
H
H
H
X
Enter Power Down
2
H
L
L
H
H
L
X
ILLEGAL
2
H
L
L
H
L
X
X
ILLEGAL
2
H
L
L
L
X
X
X
ILLEGAL
2
L
X
X
X
X
X
X
Refer to Current State =Power Down
2
H
H
X
X
X
X
X
Refer to Function Truth Table
H
L
X
X
X
X
X
Begin CLK Suspend at Next Cycle
3
L
H
X
X
X
X
X
Exit CLK Suspend at Next Cycle
3
L
L
X
X
X
X
X
Maintain CLK Suspend
ABBREVIATIONS:
H=High Level, L=Low Level, X=Don't Care
NOTES:
1. CKE Low to High transition will re-enable CLK and other inputs asynchronously.
.
A minimum setup time must be satisfied before any command other than EXIT.
2. Power-Down and Self-Refresh can be entered only from the All Banks Idle State.
3. Must be legal command.
MITSUBISHI ELECTRIC
11
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
SIMPLIFIED STATE DIAGRAM
POWER
APPLIED
POWER
ON
PRE
CHARGE
ALL
PREA
SELF
REFRESH
REFS
MRS
MODE
REGISTER
SET
REFSX
MRS
AUTO
REFRESH
REFA
IDLE
CKEL
CKEH
Active
Power
Down
ACT
POWER
DOWN
CKEL
CKEH
ROW
ACTIVE
WRITE
BURST
STOP
READ
READ
WRITE
WRITEA
WRITE
READA
READ
WRITEA
READ
TERM
READA
READA
WRITEA
READA
PRE
PRE
PRE
PRE
CHARGE
Automatic Sequence
Command Sequence
MITSUBISHI ELECTRIC
12
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
POWER ON SEQUENCE
Before starting normal operation, the following power on sequence is necessary to prevent a
SDRAM from damaged or multifunctioning.
1. Apply VDD before or the same time as VDDQ
2. Apply VDDQ before or at the same time as VTT & Vref
3. Maintain stable condition for 200us after stable power and CLK, apply NOP or DSEL
4. Issue precharge command for all banks of the device
5. Issue EMRS
6. Issue MRS for the Mode Register and to reset the DLL
7. Issue 2 or more Auto Refresh commands
8. Maintain stable condition for 200 cycle
After these sequence, the DDR SDRAM is idle state and ready for normal operation.
MODE REGISTER
CLK
Burst Length, Burst Type and /CAS Latency can be
programmed by setting the mode register (MRS). The mode
register stores these data until the next MRS command, which
may be issued when both banks are in idle state. After tRSC from
a MRS command, the DDR SDRAM is ready for new command.
/CLK
/CS
/RAS
/CAS
/WE
BA1 BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
BA0
BA1
0
0
0
0
0
DR
CL
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Latency
Mode
LTMODE
0
/CAS Latency
R
R
2
R
R
R
2.5
R
BT
BL
A11-A0
BL
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Burst
Length
Burst Type
DLL Reset
0
NO
1
YES
MITSUBISHI ELECTRIC
V
BT=0
R
2
4
8
R
R
R
R
BT=1
R
2
4
8
R
R
R
R
0
Sequential
1
Interleaved
R: Reserved for Future Use
13
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
EXTENDED MODE REGISTER
DLL disable / enable mode can be programmed by setting the extended
CLK
mode register (EMRS). The extended mode register stores these data
/CLK
until the next EMRS command, which may be issued when all banks are
in idle state. After tRSC from a EMRS command, the DDR SDRAM is
/CS
ready for new command.
/RAS
/CAS
/WE
BA1 BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
BA0
0
0
0
0
0
0
0
0
0
0
0
QFC DS
DD
BA1
V
A11-A0
DLL Disable
Drive
Strength
QFC
MITSUBISHI ELECTRIC
0
1
0
1
0
1
DLL Enable
DLL Disable
Normal
Weak
Disable
Enable
14
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
/CLK
CLK
Command
Read
Write
Y
Y
Address
DQS
Q0 Q1 Q2 Q3
DQ
CL= 2
BL= 4
Initial Address
A2
D0 D1 D2 D3
Burst
Length
Burst
Length
/CAS
Latency
BL
Column Addressing
A1 A0
Sequential
Interleaved
0
0
0
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
0
1
1
2
3
4
5
6
7
0
1
0
3
2
5
4
7
6
0
1
0
2
3
4
5
6
7
0
1
2
3
0
1
6
7
4
5
0
1
1
3
4
5
6
7
0
1
2
3
2
1
0
7
6
5
4
8
1
0
0
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
1
0
1
5
6
7
0
1
2
3
4
5
4
7
6
1
0
3
2
1
1
0
6
7
0
1
2
3
4
5
6
7
4
5
2
3
0
1
1
1
1
7
0
1
2
3
4
5
6
7
6
5
4
3
2
1
0
-
0
0
0
1
2
3
0
1
2
3
-
0
1
1
2
3
0
1
0
3
2
4
-
1
0
2
3
0
1
2
3
0
1
-
1
1
3
0
1
2
3
2
1
0
-
-
0
0
1
0
1
1
0
1
0
2
-
-
1
MITSUBISHI ELECTRIC
15
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Conditions
Ratings
Unit
Vdd
Supply Voltage
with respect to Vss
-0.5 ~ 3.7
V
VddQ
Supply Voltage for Output
with respect to VssQ
-0.5 ~ 3.7
V
VI
Input Voltage
with respect to Vss
-0.5 ~ Vdd+0.5
V
VO
Output Voltage
with respect to VssQ
-0.5 ~ VddQ+0.5
V
IO
Output Current
50
mA
1000
mW
Pd
Power Dissipation
Topr
Operating Temperature
Tstg
o
Ta = 25 C
Storage Temperature
0 ~ 70
o
-65 ~ 150
o
C
C
DC OPERATING CONDITIONS
(Ta=0 ~ 70oC, unless otherwise noted)
S ym bol
P a ra m e te r
V dd
S upply V olta ge
V ddQ
S upply V olta ge for O utput
V re f
Input R e fe re nc e V olta ge
V IH (D C )
H igh-L e ve l Input V olta ge
V IL (D C )
L ow -L e ve l Input V olta ge
V IN (D C )
Input V olta ge L e ve l, C L K a nd /C L K
V ID (D C ) Input D iffe re ntia l V olta ge , C L K a nd /C L K
V TT
I/O T e rm ina tion V olta ge
M in.
2.3
2.3
0.49*V ddQ
V re f + 0.18
-0.3
-0.3
0.36
V re f - 0.04
L im its
T yp.
2.5
2.5
0.50*V ddQ
M a x.
2.7
2.7
0.51*V ddQ
V ddQ +0.3
V re f - 0.18
V ddQ + 0.3
V ddQ + 0.6
V re f + 0.04
U nit N ote s
V
V
V
V
V
V
V
V
5
7
6
CAPACITANCE
(Ta=0 ~ 70oC, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, unless otherwise noted)
Symbol
Parameter
Test Condition
CI(A)
CI(C)
CI(K)
CI/O
CO(QF)
Input Capacitance, address pin
Input Capacitance, control pin
Input Capacitance, CLK pin
I/O Capacitance, I/O, DQS, DM pin
Output Capacitance, /QFC
VI=1.25v
f=100MHz
VI=25mVrms
MITSUBISHI ELECTRIC
Limits
Delta
Unit Notes
Min. Max. Cap.(Max.)
2.0
3.0
pF
11
0.50
2.0 3.0
pF
11
2.0 3.0
0.25
pF
11
4.0 5.0
pF
11
0.50
2.0 3.0
pF
11
16
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
AVERAGE SUPPLY CURRENT from Vdd
(Ta=0 ~ 70oC, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, Output Open, unless otherwise noted)
Symbol
Parameter/Test Conditions
Organization
Limits(Max.)
-75
-10
x4
105
95
x8
110
105
x16
120
115
x4
110
100
x8
115
110
x16
135
130
x4/x8/x16
20
20
x4/x8/x16
40
40
x4/x8/x16
40
40
x4
60
55
x8
65
60
x16
75
70
x4
150
140
x8
170
160
x16
210
200
x4
145
135
x8
165
155
x16
200
180
IDD5 AUTO REFRESH CURRENT: t RC = t RFC (MIN)
x4/x8/x16
190
180
IDD6 SELF REFRESH CURRENT: CKE < 0.2V
x4/x8/x16
3
3
OPERATING CURRENT: One Bank; Active-Precharge; t RC = t RC MIN; t CK
IDD0 = t CK MIN; DQ, DM and DQS inputs changing twice per clock cycle; address
and control inputs changing once per clock cycle
OPERATING CURRENT: One Bank; Active-Read-Precharge;
IDD1 Burst = 2; t RC = t RC MIN; CL = 2.5; t CK = t CK MIN; IOUT= 0mA;
Address and control inputs changing once per clock cycle
IDD2P
PRECHARGE POWER-DOWN STANDBY CURRENT: All banks idle; powerdown mode; CKE <VIL (MAX); t CK = t CK MIN
IDLE STANDBY CURRENT: /CS > VIH (MIN); All banks idle;
IDD2N CKE > VIH (MIN); t CK = t CK MIN; Address and other control inputs changing
once per clock cycle
IDD3P
ACTIVE POWER-DOWN STANDBY CURRENT: One bank active; powerdown mode; CKE < VIL (MAX); t CK = t CK MIN
ACTIVE STANDBY CURRENT: /CS > VIH (MIN); CKE > VIH (MIN); One
bank; Active-Precharge; t RC = t RAS MAX; t CK = t CK MIN; DQ,DM and
IDD3N
DQS inputs changing twice per clock cycle; address and other control inputs
changing once per clock cycle
OPERATING CURRENT: Burst = 2; Reads; Continuous burst;One bank active;
IDD4R Address and control inputs changing once per clock cycle;CL=2.5; t CK = t CK
MIN; IOUT = 0 mA
OPERATING CURRENT: Burst = 2; Writes; Continuous burst; One bank active;
IDD4W Address and control inputs changing once per clock cycle; CL=2.5; t CK = t CK
MIN;DQ, DM and DQS inputs changing twice per clock cycle
Unit
Notes
mA
9
AC OPERATING CONDITIONS AND CHARACTERISTICS
(Ta=0 ~ 70oC, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, Output Open, unless otherwise noted)
S ymb o l
P a ra me ter / Test C o nd itio ns
V IH (A C ) H igh- Level Inp ut V o ltage (A C )
V IL(A C ) Lo w - Level Inp ut V o ltage (A C )
Limits
M in.
V ref + 0 .3 5
M ax.
V ref - 0 .3 5
V ID (A C )
V IX (A C )
IO Z
II
Inp ut D ifferential V o ltage, C LK and /C LK
Inp ut C ro ssing P o int V o ltage, C LK and /C LK
O ff- state O utp ut C urrent /Q flo ating V o = 0 ~ V d d Q
Inp ut C urrent / V IN = 0 ~ V d d Q
IO H
IO L
O utp ut H igh C urrent (V O U T = 1 .9 5 V )
O utp ut H igh C urrent (V O U T = 0 .3 5 V )
0 .7
V d d Q + 0 .6
0 .5 * V d d Q - 0 .2 0 .5 * V d d Q + 0 .2
-5
5
-2
2
- 1 6 .8
1 6 .8
MITSUBISHI ELECTRIC
U nit
N o tes
V
V
V
V
µA
µA
7
8
mA
mA
17
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
AC TIMING REQUIREMENTS
(Ta=0 ~ 70oC, Vdd = VddQ = 2.5V +0.2V, Vss = VssQ = 0V, unless otherwise noted)
Symbol
AC Characteristics Parameter
-75
-10
Unit
Min.
Max
Min.
Max
DQ Output Valid data delay time from CLK//CLK
-0.75
0.75
-0.8
0.8
ns
tDQSCK DQ Output Valid data delay time from CLK//CLK
-0.75
0.75
-0.8
0.8
ns
tAC
tCH
CLK High level width
0.45
0.55
0.45
0.55
ns
tCL
CLK Low level width
0.45
0.55
0.45
0.55
ns
tCK
CLK cycle time
7.5
15
8
15
ns
10
15
10
15
ns
tDH
Input Setup time (DQ,DM)
0.5
0.6
ns
tDS
Input Hold time(DQ,DM)
0.5
0.6
ns
tDIPW
DQ and DM input pulse width (for each input)
1.75
tHZ
Data-out-high impedance time from CLK//CLK
-0.75
0.75
-0.8
0.8
ns
14
tLZ
Data-out-low impedance time from CLK//CLK
-0.75
0.75
-0.8
0.8
ns
14
-0.5
0.5
-0.6
0.6
ns
tDQSQ DQ Valid data delay time from DQS
tHP
Clock half period
tCLmin or
tCHmin
tQH
Output DQS valid window
tHP-0.75
tDQSS
Write command to first DQS latching transition
0.75
2
Notes
ns
tCLmin or
tCHmin
ns
tHP-1.0
1.25
0.75
ns
1.25
tCK
tDQSH DQS input High level width
0.35
0.35
tCK
tDQSL DQS input Low level width
0.35
0.35
tCK
tDSS
DQS falling edge to CLK setup time
0.2
0.2
tCK
tDSH
DQS falling edge hold time from CLK
0.2
0.2
tCK
tMRD
Mode Register Set command cycle time
15
15
ns
0
0
ns
16
tCK
15
tWPRES Write preamble setup time
tWPST Write postamble
0.4
0.6
0.4
0.6
tWPRE Write preamble
0.25
0.25
tCK
tIS
Input Setup time (address and control)
0.9
1.2
ns
19
tIH
Input Hold time (address and control)
0.9
1.2
ns
19
tRPST
Read postamble
0.4
0.6
0.4
0.6
tCK
tRPRE
Read preamble
0.9
1.1
0.9
1.1
tCK
tQPST
/QFC postamble during reads
0.4
0.6
0.4
0.6
tCK
0.9
1.1
0.9
1.1
tCK
4
ns
2
ns
tQPRE /QFC preamble during reads
tQCK
/QFC output access time from CLK//CLK, for write
tQOH
/QFC output hold time for writes
4
1.25
2
MITSUBISHI ELECTRIC
1.25
18
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
AC TIMING REQUIREMENTS(Continues)
(Ta=0 ~ 70oC, Vdd = VddQ = 2.5V +0.2V, Vss = VssQ = 0V, unless otherwise noted)
Symbol
AC Characteristics Parameter
-75
-10
Min.
Max
Min.
Max
120,000
50
120,000
Unit
Notes
tRAS
Row Active time
45
tRC
Row Cycle time(operation)
65
70
ns
tRFC
Auto Ref. to Active/Auto Ref. command period
75
80
ns
tRCD
Row to Column Delay
20
20
ns
tRP
Row Precharge time
20
20
ns
tRRD
Act to Act Delay time
15
15
ns
tWR
Write Recovery time
15
15
ns
tDAL
Auto Precharge write recovery + precharge time
35
35
ns
tWTR
Internal Write to Read Command Delay
1
1
tCK
tXSNR Exit Self Ref. to non-Read command
75
80
ns
tXSRD Exit Self Ref. to -Read command
200
200
tCK
tXPNR Exit Power down to command
1
1
tCK
tXPRD Exit Power down to -Read command
1
1
tCK
18
15.6
15.6
µs
17
tREFI
Average Periodic Refresh interval
ns
Output Load Condition
VREF
DQS
VTT =VREF
DQ
VREF
50Ω
VOUT
Zo=50Ω
30pF
VREF
Output Timing
Measurement
Reference Point
MITSUBISHI ELECTRIC
19
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
Notes
1. All voltages referenced to Vss.
2. Tests for AC timing, IDD, and electrical, AC and DC characteristics, may be conducted at nominal reference/supply
voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified.
3. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5V in the test environment, but input timing is still
referenced to VREF (or to the crossing point for CK//CK), and parameter specifications are guaranteed for the
specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1V/ns in the
range between VIL(AC) and VIH(AC).
4. The AC and DC input level specifications are as defined in the SSTL_2 Standard (i.e. the receiver will effectively
switch as a result of the signal crossing the AC input level, and will remain in that state as long as the signal does not
ring back above (below) the DC input LOW (HIGH) level.
5. VREF is expected to be equal to 0.5*VddQ of the transmitting device, and to track variations in the DC level of the
same. Peak-to-peak noise on VREF may not exceed +2% of the DC value.
6. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be
set equal to VREF, and must track variations in the DC level of VREF.
7. VID is the magnitude of the difference between the input level on CLK and the input level on /CLK.
8. The value of VIX is expected to equal 0.5*VddQ of the transmitting device and must track variations in the DC level
of the same.
9. Enables on-chip refresh and address counters.
10. IDD specifications are tested after the device is properly initialized.
11. This parameter is sampled. VddQ = 2.5V+0.2V, Vdd = 2.5V + 0.2V , f = 100 MHz, Ta = 25oC, VOUT(DC) =
VddQ/2, VOUT(PEAK TO PEAK) = 25mV. DM inputs are grouped with I/O pins - reflecting the fact that they are
matched in loading (to facilitate trace matching at the board level).
12. The CLK//CLK input reference level (for timing referenced to CLK//CLK) is the point at which CLK and /CLK
cross; the input reference level for signals other than CLK//CLK, is VREF.
13. Inputs are not recognized as valid until VREF stabilizes. Exception: during the period before VREF stabilizes,
CKE< 0.3VddQ is recognized as LOW.
14. t HZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not
referenced to a specific voltage level, but specify when the device output is no longer driving (HZ), or begins driving
(LZ).
15. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this
parameter, but system performance (bus turnaround) will degrade accordingly.
16. The specific requirement is that DQS be valid (HIGH, LOW, or at some point on a valid transition) on or before
this CLK edge. A valid transition is defined as monotonic, and meeting the input slew rate specifications of the device.
When no writes were previously in progress on the bus, DQS will be transitioning from High-Z to logic LOW. If a
previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time,
depending on tDQSS.
17. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device.
18. tXPRD should be 200 tCLK in the condition of the unstable CLK operation during the power down mode.
19. For command/address and CK & /CK slew rate > 1.0V/ns.
MITSUBISHI ELECTRIC
20
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
Read Operation
tCK
tCH
tCL
/CLK
CLK
tIS
Cmd &
Add.
tIH
Valid Data
tDQSCK
tRPST
tRPRE
DQS
VREF
tQPST
/QFC
tQPRE
tDQSQ
tQH
tAC
DQ
Write Operation / tDQSS=max.
/CLK
CLK
tDQSS
tWPST
tDSS
tWPRES
DQS
tQCK
tDQSL
tWPRE
/QFC
tDQSH
tDS
tQOH(min)
tDH
DQ
Write Operation / tDQSS=min.
/CLK
CLK
tDSH
tDQSS
tWPST
DQS
/QFC
tQCK
tWPRES
tWPRE
tDQSL
tDS
tDQSH
tQOH(max)
tDH
DQ
MITSUBISHI ELECTRIC
21
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
OPERATIONAL DESCRIPTION
BANK ACTIVATE
The DDR SDRAM has four independent banks. Each bank is activated by the ACT command with
the bank addresses (BA0,1). A row is indicated by the row address A11-0. The minimum activation
interval between one bank and the other bank is tRRD. Maximum 2 ACT commands are allowed
within tRC,although the number of banks which are active concurrently is not limited.
PRECHARGE
The PRE command deactivates the bank indicated by BA0,1. When multiple banks are active, the
precharge all command (PREA,PRE+A10=H) is available to deactivate them at the same time. After
tRP from the precharge, an ACT command to the same bank can be issued.
Bank Activation and Precharge All (BL=8, CL=2)
/CLK
CLK
2 ACT command / tRCmin
tRCmin
Command
ACT
ACT READ
tRRD
A0-9,11
Xa
PRE
tRP
tRAS
Xb
ACT
Y
tRCD
Xb
BL/2
A10
Xa
Xb
0
BA0,1
00
01
00
1
Xb
01
DQS
DQ
Qa0
Qa1
Qa2
Qa3
Qa4
Qa5
Qa6
Qa7
Precharge all
A precharge command can be issued at BL/2 from a read command without data loss.
MITSUBISHI ELECTRIC
22
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
READ
After tRCD from the bank activation, a READ command can be issued. 1st Output data is available
after the /CAS Latency from the READ, followed by (BL-1) consecutive data when the Burst Length
is BL. The start address is specified by A11,A9-A0(x4)/A9-A0(x8)/A8-A0(x16), and the address
sequence of burst data is defined by the Burst Type. A READ command may be applied to any
active bank, so the row precharge time (tRP) can be hidden behind continuous output data by
interleaving the multiple banks. When A10 is high at a READ command, the auto-precharge
(READA) is performed. Any command(READ,WRITE,PRE,ACT) to the same bank is inhibited till
the internal precharge is complete. The internal precharge starts at BL/2 after READA. The next
ACT command can be issued after (BL/2+tRP) from the previous READA.
Multi Bank Interleaving READ (BL=8, CL=2)
/CLK
CLK
Command
ACT
READ ACT
READ PRE
tRCD
A0-9,11
Xa
Y
Xb
Y
A10
Xa
0
Xb
0
0
BA0,1
00
00
10
10
00
DQS
DQ
Qa0
Qa1
Qa2
Qa3
Qa4
Qa5
Qa6
Qa7
Qb0
Qb1
Qb2
Qb3
Qb4
Qb5
Qb7
Qb8
Burst Length
/CAS latency
MITSUBISHI ELECTRIC
23
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
READ with Auto-Precharge (BL=8, CL=2)
/CLK
CLK
BL/2 + tRP
Command
ACT
A0-9,11
Xa
Y
Xb
A10
Xa
1
Xb
BA0,1
00
00
00
READ
ACT
tRCD
tRP
BL/2
DQS
DQ
Qa0
Qa1
Qa2
Qa3
Qa4
Qa5
Qa6
Qa7
Internal precharge start
READ Auto-Precharge Timing (BL=8)
/CLK
CLK
Command
ACT
READ
BL/2
CL=2.5 DQ
CL=2 DQ
Qa0
Qa0
Qa1
Qa2
Qa1
Qa2
Qa3
Qa3
Qa4
Qa4
Qa5
Qa6
Qa5
Qa6
Qa7
Qa7
Internal Precharge Start Timing
MITSUBISHI ELECTRIC
24
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
WRITE
After tRCD from the bank activation, a WRITE command can be issued. 1st input data is set from
the WRITE command with data strobe input, following (BL-1) data are written into RAM, when
the Burst Length is BL. The start address is specified by A11,A9-A0(x4)/A9-A0(x8)/A8-A0(x16),
and the address sequence of burst data is defined by the Burst Type. A WRITE command may be
applied to any active bank, so the row precharge time (tRP) can be hidden behind continuous input
data by interleaving the multiple banks. From the last data to the PRE command, the write recovery
time (tWRP) is required. When A10 is high at a WRITE command, the auto-precharge(WRITEA) is
performed. Any command(READ,WRITE,PRE,ACT) to the same bank is inhibited till the internal
precharge is complete. The next ACT command can be issued after tDAL from the last input data
cycle.
Multi Bank Interleaving WRITE (BL=8)
/CLK
CLK
Command
A0-9,11
ACT
WRITE
WRITE ACT
tRCD
Xa D
Ya
Xb
tRCD
D
PRE
PRE
Yb
A10
Xa
Xa
0
Xb
0
0
0
BA0,1
00
00
10
10
00
10
DQS
Da0
DQ
Da1
Da2
Da3
Da4
Da5
Da6
Da7
Db0
Db1
Db2
Db3
Db4
Db5
Db6
Db7
WRITE with Auto-Precharge (BL=8)
/CLK
CLK
Command
ACT
WRITE
ACT
tDAL
tRC
A0-9,11
Xa
Y
Xb
A10
Xa
1
Xb
BA0,1
00
00
00
D
DQS
DQ
Da0
Da1
Da2
Da3
Da4
Da5
Da6
Da7
MITSUBISHI ELECTRIC
25
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
BURST INTERRUPTION
[Read Interrupted by Read]
Burst read operation can be interrupted by new read of any bank. Random column access is allowed.
READ to READ interval is minimum 1CLK.
Read Interrupted by Read (BL=8, CL=2)
/CLK
CLK
Command
READ READ
READ
READ
Yi
Yj
Yk
Yl
A10
0
0
0
0
BA0,1
00
00
10
01
A0-9,11
DQS
Qai0 Qai1 Qaj0 Qaj1
DQ
Qaj2 Qaj3 Qak0 Qak1 Qak2 Qak3 Qak4 Qak5 Qal0 Qal1 Qal2
Qal3 Qal4 Qal5 Qal6 Qal7
[Read Interrupted by precharge]
Burst read operation can be interrupted by precharge of the same bank. READ to PRE interval is
minimum 1 CLK. A PRE command to output disable latency is equivalent to the /CAS Latency.
As a result, READ to PRE interval determines valid data length to be output. The figure below
shows examples of BL=8.
Read Interrupted by Precharge (BL=8)
/CLK
CLK
Command
READ
PRE
DQS
DQ
Command
CL=2.5
READ
Q0
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q4
Q5
PRE
DQS
DQ
Command
READ PRE
DQS
DQ
MITSUBISHI ELECTRIC
26
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
Read Interrupted by Precharge (BL=8)
/CLK
CLK
Command
READ
PRE
DQS
DQ
Command
CL=2.0
Q0
READ
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q4
Q5
PRE
DQS
DQ
Command
READ PRE
DQS
DQ
MITSUBISHI ELECTRIC
27
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Read Interrupted by Burst Stop]
Burst read operation can be interrupted by a burst stop command(TERM). READ to TERM interval
is minimum 1 CLK. A TERM command to output disable latency is equivalent to the /CAS Latency.
As a result, READ to TERM interval determines valid data length to be output. The figure below
shows examples of BL=8.
Read Interrupted by TERM (BL=8)
/CLK
CLK
Command
TERM
READ
DQS
DQ
Command
CL=2.5
READ
Q0
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q4
Q4
Q5
TERM
DQS
DQ
Command
READ TERM
DQS
DQ
Command
READ
TERM
DQS
Q0
DQ
Command
CL=2.0
READ
Q1
Q2
Q3
Q0
Q1
Q2
Q3
Q0
Q1
Q5
TERM
DQS
DQ
Command
READ TERM
DQS
DQ
MITSUBISHI ELECTRIC
28
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Read Interrupted by Write with TERM]
Read Interrupted by TERM (BL=8)
/CLK
CLK
Command
CL=2.5
READ
TERM
DQS
Q0
DQ
Command
CL=2.0
WRITE
READ
Q1
TERM
Q2
Q3
D0 D1
D2
D3
D4
D5
D2
D4
D5
D6
D7
WRITE
DQS
DQ
Q0
Q1
Q2
Q3
MITSUBISHI ELECTRIC
D0
D1
D3
29
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Write interrupted by Write]
Burst write operation can be interrupted by write of any bank. Random column access is allowed.
WRITE to WRITE interval is minimum 1 CLK.
Write Interrupted by Write (BL=8)
/CLK
CLK
Command
WRITE WRITE
WRITE
WRITE
A0-9,11
Yi
Yj
Yk
Yl
A10
0
0
0
0
BA0,1
00
00
10
00
DQS
DQ
Dai0 Dai1 Daj0
Daj1 Daj2 Daj3 Dak0 Dak1 Dak2 Dak3 Dak4 Dak5 Dal0
Dal1 Dal2 Dal3 Dal4 Dal5 Dal6
Dal7
[Write interrupted by Read]
Burst write operation can be interrupted by read of the same or the other bank. Random column
access is allowed. Internal WRITE to READ command interval(tWTR) is minimum 1 CLK. The
input data on DQ at the interrupting READ cycle is "don't care". tWTR is referenced from the first
positive edge after the last data input.
Write Interrupted by Read (BL=8, CL=2.5)
/CLK
CLK
Command
A0-9,11
A10
BA0,1
WRITE
READ
Yi
Yj
0
0
00
00
DM
tWTR
QS
DQ
Dai0
Dai1
Qaj0
Qaj1 Qaj2 Qaj3 Qaj4 Qaj5 Qaj6
MITSUBISHI ELECTRIC
Qaj7
30
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Write interrupted by Precharge]
Burst write operation can be interrupted by precharge of the same or all bank. Random column
access is allowed. tWR is referenced from the first positive CLK edge after the last data input.
Write Interrupted by Precharge (BL=8, CL=2.5)
/CLK
CLK
Command
WRITE
A0-9,11
Yi
A10
0
BA0,1
PRE
00
00
tWR
DM
QS
DQ
Dai0
Dai1
MITSUBISHI ELECTRIC
31
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Initialize and Mode Register sets]
Initialize and MRS
/CLK
CLK
CKE
Command
NOP
PRE
A0-9,11
1
A10
BA0,1
EMRS
MRS
Code
Code
Code
Code
10
00
PRE
AR
AR
MRS
ACT
Xa
1
Code
Xa
00
Xa
DQS
DQ
tMRD
Extended Mode
Register Set
tMRD
tRP
tRFC
tRFC
tMRD
Mode Register Set,
Reset DLL
[AUTO REFRESH]
Single cycle of auto-refresh is initiated with a REFA(/CS=/RAS=/CAS=L,/WE=CKE=H)
command. The refresh address is generated internally. 4096 REFA cycles within 64ms refresh
128Mbits memory cells. The auto-refresh is performed on 4 banks concurrently. Before performing
an auto refresh, all banks must be in the idle state. Auto-refresh to auto-refresh interval is minimum
tRFC . Any command must not be supplied to the device before tRFC from the REFA command.
Auto-Refresh
/CLK
CLK
/CS
NOP or DESELECT
/RAS
/CAS
/WE
CKE
tRFC
A0-11
BA0,1
Auto Refresh on All Banks
Auto Refresh on All Banks
MITSUBISHI ELECTRIC
32
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[SELF REFRESH]
Self -refresh mode is entered by issuing a REFS command (/CS=/RAS=/CAS=L,/WE=H,CKE=L).
Once the self-refresh is initiated, it is maintained as long as CKE is kept low. During the selfrefresh mode, CKE is asynchronous and the only enable input, all other inputs including CLK are
disabled and ignored, so that power consumption due to synchronous inputs is saved. To exit the
self-refresh, supplying stable CLK inputs, asserting DESEL or NOP command and then asserting
CKE for longer than tXSNR/tXSRD.
Self-Refresh
/CLK
CLK
/CS
/RAS
/CAS
/WE
CKE
A0-11
X
Y
BA0,1
X
Y
tXSNR
tXSRD
Self Refresh Exit
MITSUBISHI ELECTRIC
33
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Asynchronous SELF REFRESH]
Asynchronous Self -refresh mode is entered by CKE=L within 2 tCLK after issuing a REFA
command (/CS=/RAS=/CAS=L,/WE=H). Once the self-refresh is initiated, it is maintained as long as
CKE is kept low. During the self-refresh mode, CKE is asynchronous and the only enable input, all
other inputs including CLK are disabled and ignored, so that power consumption due to synchronous
inputs is saved. To exit the self-refresh, supplying stable CLK inputs, asserting DESEL or NOP
command and then asserting CKE for longer than tXSNR/tXSRD.
Asynchronous Self-Refresh
/CLK
CLK
/CS
/RAS
/CAS
/WE
CKE
max 2 tCLK
A0-11
BA0,1
tXSNR
Self Refresh Exit
MITSUBISHI ELECTRIC
34
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
[Power DOWN]
The purpose of CLK suspend is power down. CKE is synchronous input except during the selfrefresh mode. A command at cycle is ignored. From CKE=H to normal function, DLL recovery time
is NOT required in the condition of the stable CLK operation during the power down mode.
Power Down by CKE
/CLK
CLK
Standby Power Down
CKE
Command
PRE
NOP
NOP
Valid
tXPNR/tXPRD
Active Power Down
CKE
Command
ACT
NOP
NOP
Valid
[DM CONTROL]
DM is defined as the data mask for writes. During writes,DM masks input data word by word. DM
to write mask latency is 0.
DM Function(BL=8,CL=2)
/CLK
CLK
Command
READ
WRITE
DM
Don't Care
DQS
DQ
D0 D1
D3 D4
D5 D6
D7
Q0
Q1
Q2
Q3
Q4
Q5
Q6
masked by DM=H
MITSUBISHI ELECTRIC
35
MITSUBISHI LSIs
DDR SDRAM (Rev.0.1)
M2S28D20/ 30/ 40ATP
Jun,'00 Preliminary
128M Double Data Rate Synchronous DRAM
Keep safety first in your circuit designs!
Mitsubishi Electric Corporation puts the maximum effort into making semiconductor products better and more reliable,
but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal
injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with
appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material or (iii)
prevention against any malfunction or mishap.
Notes regarding these materials
These materials are intended as a reference to assist our customers in the selection of the Mitsubishi semiconductor
product best suited to the customer’s application; they do not convey any license under any intellectual property rights, or
any other rights, belonging to Mitsubishi Electric Corporation or a third party.
Mitsubishi Electric Corporation assumes no responsibility for any damage, or infringement of any third-party’s rights,
originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples
contained in these materials.
All information contained in these materials, including product data, diagrams, charts, programs and algorithms
represents information on products at the time of publication of these materials, and are subject to change by Mitsubishi
Electric Corporation without notice due to product improvements or other reasons. It is therefore recommended that
customers contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for the
latest product information before purchasing a product listed herein.
The information described here may contain technical inaccuracies or typographical errors. Mitsubishi Electric
Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors.
Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the
Mitsubishi Semiconductor home page (http://www.mitsubishichips.com).
When using any or all of the information contained in these materials, including product data, diagrams, charts, programs,
and algorithms, please be sure to evaluate all information as a total system before making a final decision on the
applicability of the information and products. Mitsubishi Electric Corporation assumes no responsibility for any damage,
liability or other loss resulting from the information contained herein.
Mitsubishi Electric Corporation semiconductors are not designed or manufactured for use in a device or system that is
used under circumstances in which human life is potentially at stake. Please contact Mitsubishi Electric Corporation or an
authorized Mitsubishi Semiconductor product distributor when considering the use of a product contained herein for any
specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea
repeater use.
The prior written approval of Mitsubishi Electric Corporation is necessary to reprint or reproduce in whole or in part these
materials.
If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a
license from the Japanese government and cannot be imported into a country other than the approved destination.
Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is
prohibited.
Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for further
details on these materials or the products contained therein.
MITSUBISHI ELECTRIC
36