MITSUBISHI RM50TC-24

MITSUBISHI DIODE MODULES
RM50TC-M,-H,-24,-2H
MEDIUM POWER GENERAL USE
INSULATED TYPE
RM50TC-M,-H,-24,-2H
• IO
• VRRM
DC output current .................... 100A
Repetitive peak reverse voltage
.......... 400/800/1200/1600V
• 3 phase bridge
• Insulated Type
• UL Recognized
Yellow Card No. E80276 (N)
File No. E80271
APPLICATION
AC motor controllers , DC motor controllers, Battery DC power supplies,
DC power supplies for control panels, and other general DC power equipment
OUTLINE DRAWING & CIRCUIT DIAGRAM
Dimensions in mm
20
40
2–φ5.5
11.5 10.5
20
10
30
5–M5
68
8
LABEL
29.5
26.5
80
Feb.1999
MITSUBISHI DIODE MODULES
RM50TC-M,-H,-24,-2H
MEDIUM POWER GENERAL USE
INSULATED TYPE
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Voltage class
M
H
24
2H
Unit
VRRM
Repetitive peak reverse voltage
400
800
1200
1600
V
VRSM
Non-repetitive peak reverse voltage
480
960
1350
1700
V
Ea
Recommended AC input voltage
110
220
370
440
V
Ratings
Unit
IO
DC output current
Three-phase full wave rectifying circuit, TC=102°C
100
A
IFSM
Surge (non-repetitive) forward current
One half cycle at 60Hz, peak value
1000
A
I2t
I2t for fusing
Value for one cycle of surge current
4.2 × 103
A2s
f
Maximum operating frequency
1000
Hz
Tj
Junction temperature
–40~+150
°C
Tstg
Storage temperature
–40~+125
°C
Viso
Isolation voltage
Parameter
Symbol
Conditions
Charged part to case
Main terminal screw M5
—
Mounting torque
Mounting screw M5
—
Weight
Typical value
2500
V
1.47~1.96
N·m
15~20
kg·cm
1.47~1.96
N·m
15~20
kg·cm
220
g
ELECTRICAL CHARACTERISTICS
Limits
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
IRRM
Repetitive reverse current
Tj=150°C, VRRM applied
—
—
10
VFM
Forward voltage
Tj=25°C, IFM=100A, instantaneous meas.
—
—
1.2
V
Rth (j-c)
Thermal resistance
Junction to case
—
—
0.2
°C/ W
Rth (c-f)
Contact thermal resistance
Case to fin, conductive grease applied
—
—
0.06
°C/ W
Insulation resistance
Measured with a 500V megohmmeter between main terminal
and case
10
—
—
MΩ
—
mA
Feb.1999
MITSUBISHI DIODE MODULES
RM50TC-M,-H,-24,-2H
MEDIUM POWER GENERAL USE
INSULATED TYPE
PERFORMANCE CURVE
MAXIMUM FORWARD CHARACTERISTIC
1000
Tj=25°C
SURGE (NON-REPETITIVE)
FORWARD CURRENT (A)
FORWARD CURRENT (A)
10 3
7
5
3
2
ALLOWABLE SURGE (NON-REPETITIVE)
FORWARD CURRENT
10 2
7
5
3
2
10 1
7
5
3
2
10 0
0.6
0.8
1.0
1.2
1.4
800
600
400
200
0
2.0
1
2 3
5 7 10
20 30
50 70100
CONDUCTION TIME
(CYCLES AT 60Hz)
MAXIMUM TRANSIENT THERMAL IMPEDANCE
(JUNCTION TO CASE)
10 0 2 3 5 7 10 1
0.20
MAXIMUM POWER DISSIPATION
250
POWER DISSIPATION (W)
TRANSIENT THERMAL IMPEDANCE
(°C/W)
FORWARD VOLTAGE (V)
0.16
0.12
0.08
0.04
0
10 –3 2 3 5 7 10 –2 2 3 5 7 10 –1 2 3 5 7 10 0
TIME (s)
RESISTIVE, INDUCTIVE LOAD
200
150
100
50
0
0
20
40
60
80
100
DC OUTPUT CURRENT (A)
ALLOWABLE CASE TEMPERATURE
VS. DC OUTPUT CURRENT
CASE TEMPERATURE (°C)
160
RESISTIVE, INDUCTIVE LOAD
140
120
100
80
60
0
20
40
60
80
100
DC OUTPUT CURRENT (A)