RECOM RP40

Features
●
●
●
●
●
●
●
●
2:1 Wide Input Voltage Range
40 Watts Output Power
1.6kVDC Isolation
Fixed Operating Frequency
Six-Sided Continuous Shield
Design Meet Safety Standard
Standard 76.2 x66.0x10.2mm Package
Efficiency to 90%
POWERLINE
DC/DC-Converter
RP40S_D_TE
Series
Selection Guide 12V, 24V and 48V Input Types
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4)
Current
mA
Efficiency(5)
%
Capacitive(6)
Load max.
µF
RP40-123.3SE
9-18
3.3
10000
3530
85
25800
RP40-1205SE
9-18
5
8000
4170
87
13600
RP40-1212SE
9-18
12
3400
4100
88
2400
RP40-1215SE
9-18
15
2700
4100
88
1550
RP40-243.3SE
18-36
3.3
10000
1720
84
25800
RP40-2405SE
18-36
5
8000
2010
87
13600
RP40-2412SE
18-36
12
3400
1980
90
2400
RP40-2415SE
18-36
15
2700
2000
88
1550
RP40-483.3SE
36-75
3.3
10000
850
85
25800
RP40-4805SE
36-75
5
8000
980
89
13600
RP40-4812SE
36-75
12
3400
1000
89
2400
RP40-4815SE
36-75
15
2700
1000
88
1550
RP40-1205DE
9-18
±5
+7000 / -1000
4330
81
12000 / 1700
RP40-1212DE
9-18
±12
±1800
4550
83
RP40-1215DE
9-18
±15
±1400
4430
83
RP40-2405DE
18-36
±5
+7000 / -1000
2130
82
RP40-2412DE
18-36
±12
±1800
2170
87
±1200
RP40-2415DE
18-36
±15
±1400
2140
86
±750
RP40-4805DE
36-75
±5
+7000 / -1000
1060
84
RP40-4812DE
36-75
±12
±1800
1100
86
±1200
RP40-4815DE
36-75
±15
±1400
1100
86
±750
RP40-123.305DE
9-18
3.3 / 5
4000 / 4000
3730
78
10300 / 6800
RP40-243.305DE
18-36
3.3 / 5
4000 / 4000
1840
79
10300 / 6800
RP40-483.305DE
36-75
3.3 / 5
4000 / 4000
910
80
10300 / 6800
RP40-120512TE
9-18
5 / ±12
4000 / ±850
4490
79
6800 / ±590
RP40-120515TE
9-18
5 / ±15
4000 / ±680
4430
80
6800 / ±380
RP40-240512TE
18-36
5 / ±12
4000 / ±850
2180
81
6800 / ±590
RP40-240515TE
18-36
5 / ±15
4000 / ±680
2160
82
6800 / ±380
RP40-480512TE
36-75
5 / ±12
4000 / ±850
1060
83
6800 / ±590
RP40-480515TE
36-75
5 / ±15
4000 / ±680
1060
83
6800 / ±380
Part Number
248
21-July-2005
40 Watt
Single, Dual,
Positive Dual &
Triple Output
±1200
±750
12000 / 1700
12000 / 1700
www.recom-international.com
POWERLINE
RP40-S_D_TE
Series
DC/DC-Converter
Derating-Graph (Ambient Temperature)
RP40-4805SE
125
100
Output Power (%)
75
50
Natural Convection
25
0
-40 -25 -10 0
50 60
Ambient Temperature Range (°C)
70 80 90 100
55°C
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at [email protected]
91
90
89
88
87
86
85
84
83
82
81
80
RP40-4805SE
RP40-4805SE
Efficiency VS Input Voltage
Efficiency VS Output Load
Efficiency (%)
Efficiency (%)
Typical Characteristics
36
40
45
50
55
60
65
70
75
91
90
89
88
86
84
82
80
70
60
50
45
0,5
1
2
3
4
5
6
7
8
Output Load (A)
Input Voltage (V)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
Input Filter
Input Surge Voltage (100 ms max.)
Pi Type
12V Input
24V Input
48V Input
Input Reflected Ripple (nominal Vin and full load)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
9-18VDC
18-36VDC
36-75VDC
36VDC
50VDC
100VDC
40mAp-p
DC-DC ON
DC-DC OFF
Nominal input
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
Single & Dual
Triple 3.3V, 5V
Auxiliary
40W max.
±2%
±2%
±5%
continued on next page
www.recom-international.com
21-July-2005
249
RP40-S_D_TE
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Voltage Adjustability
Minimum Load
Line Regulation (LL-HL at full load)
Load Regulation (25% to 100% FL)
Cross Regulation (Note 8)
±10%
RP40-xx3.305DE
others
Single
Dual
Triple 3.3V, 5V
Auxiliary
Single
Dual
Triple 3.3V, 5V
Auxiliary
Dual
Triple 3.3V, 5V
Auxiliary
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
20% min.
10% of FL
±0.5%
±1%
±2%
±5%
±0.5%
±1%
±2%
±5%
±1%
±1%
±5%
1%/p-p of Vout max.
±0.02%/°C, max.
3.3V
5V
12V
15V
500µS
3.9V
6.2V
15V
18V
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
1.600VDC min.
Isolation Resistance
109 Ω min.
Isolation Capacitance
500pF max.
Operating Frequency
185kHz typ.
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
+100°C
Natural convection
Thermal Shock
-55°C to +105°C
7.3°C/Watt
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel-Coated copper
Base Material
Non-conductive black plastic FR4
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
48g
Dimensions
76.2 x 66.0 x 10.2mm
1.315 x 106 Hours
MTBF (see note 2)
250
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
21-July-2005
www.recom-international.com
RP40-S_D_TE
Series
POWERLINE
DC/DC-Converter
Notes :
1. The RP40 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control pin voltage is referenced to negative input
8. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other
auxiliary load change from 25% to 100% load
9. See application notes for EMI-filtering.
Package Style and Pinning (mm)
3rd angle
projection
66.00
76.20
10.20
8.00
dia.
1.0
63.50
7.6
Pin Connections
10.20
17.80
10
10.20
4
9
10.20
10.20
3
10.20
Bottom View
8
12.70
2
7
15.20
7.60
1
Pin #
Single
1
CTRL
2
+Vin
3
-Vin
4
SYNC
5
Trim Down
6
Trim
7
Trim Up
8
+Vout
9
-Vout
10
No Pin
NC = No Connection
Dual
CTRL
+Vin
-Vin
SYNC
+Vout
Com
-Vout
Trim
NC
NC
Triple
CTRL
+Vin
-Vin
SYNC
+Aux
Com (Aux)
-Aux
+Vout(Primary)
Com(Primary)
Trim
3.3V / 5V
CTRL
+Vin
-Vin
SYNC
3.3V
Com
+5V
Trim
NC
NC
Pin Pitch Tolerance ±0.35 mm
6
7.60
5
www.recom-international.com
21-July-2005
251
RP40-S_D_TE
Series
POWERLINE
DC/DC-Converter
Application of Synchronization
Converter 1
2
+ Vin
4
3
– Vin
1. The unit is capable of external synchronization from
an independent time base with a switching rate
between 200kHz and 215 kHz.
2. The amplitude of the synchronizing pulse train is
TTL compatible.
3. The duty cycle of the CLK should be 20% high and
80% low.
4. Synchronization is referenced to negative input
(–Vin).
+
Sync
–
Converter 2
2
4
3
Converter
2
+ Vin
+
1
Sync
3
– Vin
–
+
CTRL
–
ON/OFF
Control
CLK
2N7000
CLK Signal
80%
20%
External Output Trimming
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
[ ] for triple output trim
{ } for RP40-xx3.305DE only trim 3.3V / 5V
7(7) [9] {6}
Trim Up
6(8) [10] {8}
RU
6(8) [10] {8}
252
Trim Down
RD
5(5) [8] {5}
21-July-2005
www.recom-international.com