Ordering number : ENN6167 CMOS IC LC72711W, 72711LW Mobile FM Multiplex Broadcast (DARC) Receiver IC Overview The LC72711W and LC72711LW are data demodulator ICs for receiving FM multiplex broadcasts for mobile reception in the DARC format. This IC includes an onchip bandpass filter for extracting the DARC signal from the FM baseband signal. Furthermore, since this IC supports all of the IT-R recommended FM multiplex frame structures (methods A, A', B, and C), it is optimal for worldwide market radios that provide FM multiplex reception. The LC72711W and LC72711LW support both parallel and CCB serial CPU interfaces. • 7.2 MHz crystal oscillator circuit • Two power saving modes: STNBY and EC_STOP • Applications can use either a parallel CPU interface (DMA) or a CCB serial interface. • Supply voltage: 4.5 to 5.5 V (LC72711W), 2.7 to 3.6 V (LC72711LW) Package Dimensions unit: mm 3190-SQFP64 [LC72711W, 72711LW] Functions 12.0 10.0 1.25 0.5 0.18 1.25 0.15 33 48 49 1.25 32 0.5 12.0 10.0 16 0.1 1 1.7max 17 64 1.25 • Adjustment-free 76 kHz SCF bandpass filter • Supports all FM multiplex frame structures (methods A, A', B, and C) under CPU control. • MSK delay detection system based on a 1T delay. • Error correction function based on a 2T delay (in the MSK detection stage) • Digital PLL based clock regeneration function • Shift-register 1T and 2T delay circuits • Block and frame synchronization detection circuits • Functions for setting the number of allowable BIC errors and the number of synchronization protection operations. • Error correction using (272, 190) codes • Built-in layer 4 CRC code checking circuit • On-chip frame memory and memory control circuit for vertical correction 0.5 0.5 SANYO: SQFP64 • CCB is a trademark of SANYO ELECTRIC CO., LTD. • CCB is SANYO’s original bus format and all the bus addresses are controlled by SANYO. Any and all SANYO products described or contained herein do not have specifications that can handle applications that require extremely high levels of reliability, such as life-support systems, aircraft’s control systems, or other applications whose failure can be reasonably expected to result in serious physical and/or material damage. Consult with your SANYO representative nearest you before using any SANYO products described or contained herein in such applications. SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all SANYO products described or contained herein. SANYO Electric Co.,Ltd. Semiconductor Company TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN 12100RM (OT) No. 6167-1/29 LC72711W, 72711LW Specifications Absolute Maximum Ratings at Ta = +25°C, VSS = 0 V. Items in parentheses refer to the LC72711LW. Parameter Symbol Maximum supply voltage Conditions VDD Input voltage Output voltage Output current Allowable output current (total) VIN(1) A0/CL, A1/CE, A2/DI, RST, STNBY VIN(2) Pins other than VIN(1) Unit V –0.3 to +7.0 V –0.3 to VDD + 0.3 V VOUT(1) DO VOUT(2) Pins other than VOUT(1) IOUT(1) INT, RDY, DREQ, and D0 to D15 0 to 4.0 mA IOUT(2) Pins other than IOUT(1) 0 to 2.0 mA ITTL Allowable power dissipation Ratings (–0.3 to +5.5) –0.3 to +7.0 Pdmax –0.3 to +7.0 V –0.3 to VDD + 0.3 V Total for all the output pins Ta ≤ +85°C 20 mA 200 mW Operating temperature Topr –40 to +85 °C Storage temperature Tstg –55 to +125 °C [LC72711W] Allowable Operating Ranges at Ta = –40 to +85°C, VSS = 0 V Parameter Supply voltage High-level input voltage Low-level input voltage Symbol Conditions VDD Ratings min typ max Unit 4.5 5.5 V VIH1 A0/CL, A1/CE, A2/DI, RST, STNBY 0.7 VDD 5.5 V VIH2 DACK, WR, RD, CS, SP, BUSWD, A3, IOCNT1, IOCNT2 0.7 VDD VDD V VIL1 Pins for which VIH1 applies VSS 0.3 VDD V VIL2 Pins for which VIH2 applies VSS 0.3 VDD FOSC XIN input sensitivity VXI With a sine wave input to XIN, capacitor coupling, VDD = +4.5 to +5.5 V 400 1500 mVrms VMPX With a 100% modulated composite signal input to MPXIN, VDD = +4.5 to +5.5 V 150 400 mVrms Serial I/O Input amplitude This IC operates with a frequency precision of ±250 ppm 7.2 V Oscillator frequency MHz Clock low-level period tCL A0/CL 0.7 µs Clock high-level period tCH A0/CL 0.7 µs Data setup time tSU A0/CL, A2/DI 0.7 µs Data hold time tHD A0/CL, A2/DI 0.7 µs CE wait time tEL A0/CL, A1/CE 0.7 µs CE setup time tES A0/CL, A1/CE 0.7 µs CE hold time tEH A0/CL, A1/CE 0.7 Data latch change time tLC A1/CE Data output time tDDO DO, A0/CL CRC4 change time tCRC CRC4, A0/CL µs 0.7 277 µs 555 ns 0.7 µs No. 6167-2/29 LC72711W, 72711LW [LC72711W] Allowable Operating Ranges: Parallel Interface at Ta = –40 to +85°C, VSS = 0 V Parameter Conditions Ratings min typ max Unit Address to RD setup tSARD A0/CL, A1/CE, A2/DI, A3, RD 20 ns RD to address hold tHARD A0/CL, A1/CE, A2/DI, A3, RD, tWRDL→250 ns –20 ns RD low-level width tWRDL1 RD 250 RD low-level width (when RDY is used) tWRDL2 RD 100 150 RD cycle wait tCYRD A0/CL, A1/CE, A2/DI, A3, RD RDY width (Register read) tWRDY RDY ns 210 ns ns 0 ns tSAWR A0/CL, A1/CE, A2/DI, A3, WR 20 ns WR to address hold tHAWR A0/CL, A1/CE, A2/DI, A3, WR 20 ns WR cycle wait tCYWR A0/CL, A1/CE, A2/DI, A3, WR 150 ns WR low-level width tWWRL WR 200 ns tRDH RD, DATn 60 ns 250 Address to WR setup RD data hold Parallel I/O Symbol WR data hold tWDH WR, DATn 0 RDY output delay tDRDY RD, RDY 0 Corrected output RD width Corrected output RD width (when RDY is used) RDY width (corrected output read) tWDRD1 tWDRD2 tWDRDY 300 RD (BUSWD = H 16 bits) 540 RD (BUSWD = L 8 bits) 100 RD (BUSWD = H 16 bits) 300 540 ns RDY (BUSWD = L 8 bits) 60 210 ns RDY ((BUSWD = H 16 bits) DREQ, DACK DMA cycle wait tCYDM RD, DREQ RD low-level width (DMA) tWRDM RD Notes: ns RD (BUSWD = L 8 bits) tDREQ DACK to DREQ delay ns 30 300 300 ns ns 300 ns 490 ns 260 ns 420 ns ns Application designs must take the RDY signal output delay into consideration if the RDY signal is used as the CPU bus wait signal. When the RDY signal is used, the “RD low-level width” and the “Corrected output RD width” values express the basic timing (excluding the wait time) settings for the CPU bus. If the RDY signal is not used, (that is, if no wait states are inserted) the value of the RD low-level width will be 250 ns (minimum). No. 6167-3/29 LC72711W, 72711LW [LC72711LW] Allowable Operating Ranges at Ta = –40 to +85°C, VSS = 0 V Parameter Supply voltage High-level input voltage Low-level input voltage Symbol Conditions Ratings min typ max Unit 2.7 3.6 V VIH1 A0/CL, A1/CE, A2/DI, RST, STNBY 0.7 VDD 5.5 V VIH2 DACK, WR, RD, CS, SP, BUSWD, A3, IOCNT1, IOCNT2 0.7 VDD VDD V VIL1 Pins for which VIH1 applies VSS 0.3 VDD V VIL2 Pins for which VIH2 applies VSS 0.3 VDD VDD FOSC XIN input sensitivity VXI With a sine wave input to XIN, capacitor coupling. VDD = +2.7 to +3.6 V 400 900 mVrms VMPX1 With a 100% modulated composite signal input to MPXIN. VDD = +3.3 V 120 350 mVrms VMPX2 With a 100% modulated composite signal input to MPXIN. VDD = +2.7 V 120 180 mVrms Serial I/O Input amplitude This IC operates with a frequency precision of ±250 ppm 7.2 V Oscillator frequency MHz Clock low-level period tCL A0/CL 0.7 µs Clock high-level period tCH A0/CL 0.7 µs Data setup time tSU A0/CL, A2/DI 0.7 µs Data hold time tHD A0/CL, A2/DI 0.7 µs CE wait time tEL A0/CL, A1/CE 0.7 µs CE setup time tES A0/CL, A1/CE 0.7 µs CE hold time tEH A0/CL, A1/CE 0.7 Data latch change time tLC A1/CE Data output time tDDO DO, A0/CL CRC4 change time tCRC CRC4, A0/CL µs 0.7 277 µs 555 ns 0.7 µs No. 6167-4/29 LC72711W, 72711LW [LC72711LW] Allowable Operating Ranges: Parallel Interface at Ta = –40 to +85°C, VSS = 0 V Parameter Conditions Ratings min typ max Unit Address to RD setup tSARD A0/CL, A1/CE, A2/DI, A3, RD 20 ns RD to address hold tHARD A0/CL, A1/CE, A2/DI, A3, RD, tWRDL→250 ns –20 ns RD low-level width tWRDL1 RD 280 RD low-level width (when RDY is used) tWRDL2 RD 100 150 RD cycle wait tCYRD A0/CL, A1/CE, A2/DI, A3, RD RDY width (Register read) tWRDY RDY ns 230 ns ns 0 ns tSAWR A0/CL, A1/CE, A2/DI, A3, WR 20 ns WR to address hold tHAWR A0/CL, A1/CE, A2/DI, A3, WR 20 ns WR cycle wait tCYWR A0/CL, A1/CE, A2/DI, A3, WR 150 ns WR low-level width tWWRL WR 200 ns tRDH RD, DATn 60 ns 280 Address to WR setup RD data hold Parallel I/O Symbol WR data hold tWDH WR, DATn 0 RDY output delay tDRDY RD, RDY 0 Corrected output RD width Corrected output RD width (when RDY is used) RDY width (corrected output read) tWDRD1 tWDRD2 tWDRDY 300 RD (BUSWD = H 16 bits) 540 RD (BUSWD = L 8 bits) 100 RD (BUSWD = H 16 bits) 300 540 ns RDY (BUSWD = L 8 bits) 60 230 ns RDY ((BUSWD = H 16 bits) DREQ, DACK DMA cycle wait tCYDM RD, DREQ RD low-level width (DMA) tWRDM RD Notes: ns RD (BUSWD = L 8 bits) tDREQ DACK to DREQ delay ns 50 300 300 ns ns 300 ns 490 ns 260 ns 420 ns ns Application designs must take the RDY signal output delay into consideration if the RDY signal is used as the CPU bus wait signal. When the RDY signal is used, the “RD low-level width” and the “Corrected output RD width” values express the basic timing (excluding the wait time) settings for the CPU bus. If the RDY signal is not used, (that is, if no wait states are inserted) the value of the “RD low-level width” will be 280 ns (minimum). No. 6167-5/29 LC72711W, 72711LW [LC72711W] Electrical Characteristics at VDD = +4.5 to +5.5 V, within the allowable operating ranges Parameter Symbol High-level input current Low-level input current Input resistance Ratings min typ max Unit VOH1 Io = 2 mA, BCK, FCK, BLOCK, FLOCK, CRC4, CLK16DATA VDD – 0.4 VOH2 Io = 4 mA, INT, RDY, DREQ, D0 to D15 VDD – 0.4 VOL1 Io = 2 mA, Pins for which VOH1 applies 0.4 V High-level output voltage Low-level output voltage Conditions V V VOL2 Io = 4 mA, Pins for which VOH2 applies 0.4 V VOL3 Io = 2 mA, DO, INT 0.4 V VIH1 VIN = 5.5 V, A0/CL, A1/CE, A2/DI, RST, STNBY 1.0 µA VIH2 VIN = VDDD, All input pins other than IIH1 1.0 µA IIL VIN = VSSD, All input pins Rmpx MPXIN – Vssa f = 100 kHz Reference supply voltage output Vref Bandpass filter center frequency Fc –1.0 50 Vref, Vdda = 5 V FLOUT µA kΩ 2.5 V 76.0 kHz –3 dB bandwidth Fbw FLOUT Group delay Dgd FLOUT Gain Gain FLOUT – MPXIN f = 76 kHz ATT1 FLOUT f = 50 kHz 25 ATT2 FLOUT f = 100 kHz 15 dB ATT3 FLOUT f = 30 kHz 50 dB 50 Stop band attenuation ATT4 FLOUT f = 150 kHz Output off leakage current IOFF V0 = VDDD, DO Hysteresis voltage VHIS A0/CL, A1/CE, A2/DI, A3, CS, RD, WR, DACK, IOCNT1, IOCNT2, RST, STNBY Internal feedback resistor Rf Current drain IDD XIN, XOUT 19.0 –7.5 kHz +7.5 20 µs dB dB dB 5.0 V 0.1 VDDD 1.0 18 µA MΩ 25 mA No. 6167-6/29 LC72711W, 72711LW [LC72711LW] Electrical Characteristics at VDD = +2.7 to +3.6 V, within the allowable operating ranges Parameter Symbol High-level input current Input resistance typ max Unit Io = 1 mA, BCK, FCK, BLOCK, FLOCK, CRC4, CLK16DATA VDD – 0.4 VOH2 Io = 2 mA, INT, RDY, DREQ, D0 to D15 VDD – 0.4 VOL1 Io = 1 mA, Pins for which VOH1 applies 0.4 V VOL2 Io = 2 mA, Pins for which VOH2 applies 0.4 V VOL3 Io = 1 mA, DO, INT 0.4 V VIN = 5.5 V, A0/CL, A1/CE, A2/DI, RST, STNBY 1.0 µA 1.0 µA IIH1 IIH2 Low-level input current Ratings min VOH1 High-level output voltage Low-level output voltage Conditions VIN = VSSD, All input pins Rmpx MPXIN – Vssa f = 100 kHz Vref Bandpass filter center frequency Fc V VIN = VDDD, All input pins other than IIH1 IIL Reference supply voltage output V –1.0 50 Vref, Vdda = 3 V FLOUT µA kΩ 1.5 V 76.0 kHz –3 dB bandwidth Fbw FLOUT Group delay Dgd FLOUT Gain Gain FLOUT – MPXIN f = 76 kHz ATT1 FLOUT f = 50 kHz 25 ATT2 FLOUT f = 100 kHz 15 dB ATT3 FLOUT f = 30 kHz 50 dB 50 Stop band attenuation ATT4 FLOUT f = 150 kHz Output off leakage current IOFF V0 = VDDD, DO Hysteresis voltage VHIS A0/CL, A1/CE, A2/DI, A3, CS, RD, WR, DACK, IOCNT1, IOCNT2, RST, STNBY Internal feedback resistor Rf Current drain IDD XIN, XOUT 19.0 –7.5 kHz +7.5 20 µs dB dB dB 1.0 V 0.1 VDDD 1.0 12 µA MΩ 20 mA No. 6167-7/29 LC72711W, 72711LW Vddd FCK BCK FLOCK BLOCK DATA CLK16 Block Diagram LPF Vssd 1T delay Clock regeneration STNBY Synchronization regeneration Error correction: layer 2 CRC Timing control 2T delay RST 7.2 MHz XOUT LPF MSK correction circuit PN decoding Data XIN Vref MPXIN Anti-aliasing filter Address 76 kHz -BPF (SCF) Memory array Output control (CPU interface) and layer 4 CRC detection circuit Vdda Vref TIN SP BUSWD A2/DI A3 DO D0 to D15 A0/CL A1/CE INT DREQ DACK CS RD WR RDY CRC4 IOCNT1 IOCNT2 CIN VREF FLOUT Vssa INT Vddd Vssd DO NC WR RD A0/CL A1/CE A2/DI A3 CS STNBY RST SP BUSWD Pin Assignment 32 49 TIN D15 NC D14 Vssa D13 Vref D12 MPXIN D11 Vdda D10 FLOUT D9 LC72711W LC72711LW CIN NC D8 D7 TPC1 D6 TPC2 D5 TEST D4 TOSEL1 D3 TOSEL2 D2 Vssd D1 SQFP-64 XIN D0 64 1 16 RDY Vddd Vssd DACK CRC4 DREQ BCK FCK FLOCK BLOCK DATA CLK16 IOCNT2 Vddd IOCNT1 XOUT (Top view) No. 6167-8/29 LC72711W, 72711LW Pin Functions Pin No. Pin 3 IOCNT1 Function Data bus I/O control 1 (SP = 4 IOCNT2 Data bus I/O control 2 (SP = low)*1 13 DACK DMA acknowledge (SP = low)*1 38 WR Write control signal (SP = low)*1 39 RD Read control signal (SP = low)*1 40 A0/CL Address input 0 (SP = low) CCB CL input (SP = high) 41 A1/CE 1 (SP = low) CCB CE input (SP = high) 42 A2/DI 2 (SP = low) CCB DI input (SP = high) 43 A3 44 CS 46 RST 45 STNBY System reset input (negative logic) Standby mode (positive logic) SP BUSWD 60 TEST 58 TPC1 59 TPC2 As above 61 TOSEL1 As above 62 TOSEL2 As above 49 TIN As above 5 CLK16 Clock regeneration monitor 6 DATA Demodulated data monitor SP = low: parallel, SP = high: serial BUSWD = low: 8 bits, BUSWD = high: 16 bits The test pin must be connected to the digital system ground (VSS). Must be connected to the digital system power supply (VDD) or ground (VSS) in normal operation. 9 FCK Frame start signal output 10 BCK Block start signal output 7 FLOCK Outputs a high level when in frame synchronization 8 BLOCK Outputs a high level when in block synchronization CRC4 INT 12 DREQ 16 RDY Input Chip select input (SP = L)*1 48 11 Pin circuit 3 (SP = low)*1 47 33 I/O low)*1 Input Output Level 4 CRC detection result output External CPU interrupt request output DMA request signal Read ready signal Data bus 17 to 24 D0 to D7 The bus width can be set to be either 8 bits or 16 bits by the BUSWD pin (pin 48). I/O For data input, only the lower 8 bits (D0 to D7) are valid. 25 to 32 D8 to D15 Data bus (in 16-bit mode) These pins are held in the output off state when BUSWD is low. 64 XIN 1 XOUT Connections for the system clock crystal oscillator circuit. The XIN pin can also be used as an external clock signal input. 53 MPXIN Baseband (multiplex) signal input 55 FLOUT Subcarrier output (76 kHz bandpass filter output) Output I/O Input Output Continued on next page. No. 6167-9/29 LC72711W, 72711LW Continued from preceding page. Pin No. Pin 56 CIN Function Subcarrier input (comparator input) I/O Pin circuit Input Vref Vdda 52 VREF Reference voltage output (Vdda/2) Output Vssa 36 DO CCB serial interface data output NC This pin must be left open Output 37 50 57 54 VDDA Analog system power supply — 51 VSSA Analog system ground — 2, 15, 34 VDDD Digital system power supply (+2.7 to +5.5 V) — 14, 35, 63 VSSD Digital system ground — Notes: 1. This pin must be connected to VDDD or VSSD if the IC is used in serial interface mode (when SP is high). 2. A capacitor of at least 2000 pF must be inserted between VDDD and VSSD. No. 6167-10/29 LC72711W, 72711LW Control Registers This IC includes both registers that can be read and registers that can be written. These registers can be accessed using either the serial interface (CCB) or the parallel interface. The SP pin switches between these interfaces. The initial values of the write registers are the data loaded into internal registers when a reset signal (RST) is received. These values are recommended values that do not need to be changed during normal operation. If the parallel interface is used, applications must hold the address fixed at 00H when reading out data to which error correction has been applied. If the CCB interface is used, the application needs only to specify the CCB address (#FB). The address 00H is an invalid address for writing. The addresses other than those specified below are control addresses particular to the IC. Applications must not specify those addresses. Address Register 1 BIC R/W Address Register Number of allowable BIC errors 2 Function W 1 STAT Status register Function R/W R SYNCB Block synchronization: error protection count W 2 BLNO Block number register R 3 SYNCF Frame synchronization: error protection count W 4 CTL1 Control register 1 W 5 CTL2 Control register 2 W 6 CRC4 Layer 4 CRC register W Number of Allowable BIC Errors Address Register R/W Initial value 01H BIC W 22H BIT7 BIT6 BIT5 Back protection BIT4 BIT3 (LSB) BIT1 BIT0 Forward protection BIT2 (LSB) The synchronization circuit in this IC operates by recognizing a 16-bit BIC code. The number of allowable errors is the number of incorrect bits allowed in those 16 bits. This data sets up separate values for forward protection mode (when synchronized) and for back protection mode (when not synchronized). The default value is to allow 2 incorrect bits in both forward and back modes. If the block synchronization discrimination output (BLOCK) is used for discriminating whether or not FM multiplex data is present, we recommend setting the back protection mode BIC allowable error count to 1 or 0. Block Synchronization: Error Protection Count Address Register R/W Initial value 02H SYNCB W 17H BIT7 BIT6 BIT5 Back protection BIT4 (LSB) BIT3 BIT1 BIT0 Forward protection BIT2 (LSB) The synchronization protection count can be set separately for both forward and back protection. The count conditions for the protection counts are as follows. • Back protection mode (not synchronized: BLOCK = low) If the timing of the IC internal synchronization free-running counter matches the timing of the received BIC, the protection count is incremented by 1. Contrarily, if the timings of the IC internal counter and the received BIC do not match, the protection counter is cleared to 0. The timing of the count is the timing of the IC internal counter. • Forward protection mode (synchronized: BLOCK = high) In reverse to the back protection mode, if the timing of the IC internal free-running counter does not match the detection timing of the received BIC, the protection counter is incremented, and if the timings match, the protection counter is cleared to 0. Figure 1 shows the states of the protection counter for the cases where the forward and back protection counts are both 3. This IC defines the value of the protection counter to be 1 at the point that a match or a discrepancy between the IC internal timing and the timing of the received BIC occurs. For example, when the value of the back protection count is 2, the IC internal timing and the timing of the received BIC will have matched two times consecutively. If the protection data is set to new values, for example if the protection counts are set to 3 as assumed in figure 1, applications must send values which are 1 less than the intended value; in this case 22H. Similarly, if the value is set to 00H, the protection counts will, by definition, be set to 1 for both the forward and back directions. However, note that the resulting operation will be equivalent to there being no protection circuit. The default values are 8 for the forward protection count and 2 for the back protection count. If the block synchronization output (BLOCK) is used for discriminating whether or not FM multiplex data is present, we recommend setting the block synchronization back protection count to a value that is more strict than the default value. (That is, we recommend replacing the default value of 2 with a value of 3 or higher.) No. 6167-11/29 LC72711W, 72711LW BIC 1 Received data 2 0 3 1 0 Reset Synchronization counter BIC position 1 2 3 BLOCK * Assumes that the forward and back protection counts are 3. Figure 1 Block Synchronization Protection Operation (Forward → Back → Forward) Frame Synchronization: Error Protection Count Address Register R/W Initial value 03H SYNCF W 17H BIT7 BIT6 BIT5 Back protection BIT4 BIT3 (LSB) BIT1 BIT0 Forward protection BIT2 (LSB) This IC detects the BIC characteristic inflection points which occur at four places in a single frame, and increments or decrements a protection counter depending on whether or not they match the IC internal frame synchronization timing counter. As is the case with the block synchronization error protection value, applications must set these to values one less than the desired protection count. The default values are 8 for the frame synchronization forward protection count and 2 for the back protection count. Control Register 1 Address Register R/W Initial value 04H CTL1 W 00H BIT7 BIT6 CRC4_RST DO_MOVE BIT5 BIT4 INT_MOVE SYNC_RST BIT3 BIT2 BIT1 BIT0 EC_STOP VEC_HALT RTIB FRAME • FRAME 0: Specifies method B. (default) 1: Specifies method A. • RTIB 0: Real-time information blocks present. (default) 1: No real-time information blocks. In the ITU-R recommended frame structure method A, a total of 12 data blocks can be inserted in the parity data area (the area that consists of 82 consecutive blocks of parity packets). If this IC is used in a system that has no real-time information blocks (RTIB), this flag must be set. Note that if this flag is changed, frame synchronization is retained in the synchronized state for the time corresponding to the forward protection count, and then switches to the unsynchronized state. To quickly reestablish frame synchronization, applications must reset the synchronization circuit using the SYNC_RST flag. • VEC_HALT 0: Vertical correction and the second horizontal correction processing are performed. (default) 1: Vertical correction and the second horizontal correction processing are not performed. All IC operations related to vertical correction and the second horizontal correction are stopped by setting this flag. Note that in data output, only data to which the first horizontal correction has been applied will be output. • EC_STOP 0: All functions operate. (default) 1: Only the MSK detection circuit and the synchronization regeneration circuit operate. This flag stops all operations relating to error correction (including RAM access), data output, and other operations. While all IC operations are stopped in standby mode, MSK demodulation, the synchronization circuit, the serial data input circuit, and the layer 4 CRC circuit continue to operate in this mode. No. 6167-12/29 LC72711W, 72711LW • SYNC_RST 0: (default) 1: Resets just the synchronization regeneration circuit. Clears the synchronization status and the synchronization protection status in the synchronization circuit block, and sets the circuit to the unsynchronized state. This allows the circuit to quickly pull in to frame synchronization when the frame synchronization is incorrect for the new reception data following tuning, when the radio has been tuned to a new station. While this flag is used for synchronization related section of the system, it does not initialize the registers that set the number of allowable BIC errors, the block synchronization forward and back protection counts, and the frame synchronization forward and back protection counts. Also note that during a synchronization block reset, the INT signal is not output and the DO pin outputs a high level (high-impedance). This flag is not automatically reset to 0. Applications must send a 0 value after setting this flag. • INT_MOVE 0: Data is only output when error correction has completed, layer 2 CRC has completed, and the data was received with the circuit synchronized. (default) 1: All data is output. (Operation is identical to that of the LC72700E.) In the default state, this IC only outputs data that has been fully error corrected and that was received in both block and frame synchronization. (This also includes the layer 2 CRC check.) To acquire all data as provided by the LC72700, applications must set both this flag and the VEC_OUT (BIT2) flag in control register 2 as described below. • DO_MOVE (Valid only when SP is high.) 0: The high state (high impedance) is held at all times other than when data is being output. (default) 1: Operate identically to the LC72700 when changes are linked to the INT signal, i.e. when both INT_MOVE and VEC_OUT are set to 1. • CRC4_RST 0: (default) 1:Reset the layer 4 CRC detection circuit. This flag is not automatically reset to 0. Applications must send a 0 value after setting this flag. Control Register 2 Address Register R/W Initial value BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 05H CTL2 W 00H SUBBLK BLK_RST DACK DREQ RDY VEC_OUT DMA_RD DMA • DMA (Valid only when SP is low.) 0: Do not use DMA transfer for readout of post-error correction data. (default) 1: Use DMA transfer for readout of post-error correction data. • DMA_RD (Valid only when SP is low.) 0: Use the RD signal as the DMA transfer read control signal. (default) 1: Use the DACK signal as the DMA transfer read control signal. • VEC_OUT 0: Do not perform post-vertical correction output when vertical correction processing is not performed. (default) 1: Output all data, even when vertical correction processing is not performed. (Operation identical to that of the LC72700E) When this flag is set and a frame of data with absolutely no errors is received, data that is completely identical to the corresponding post-horizontal correction data is output with the timing of the output of post-vertical correction data, even if vertical correction is not performed. This flag must be set to create interface specifications identical to those of the LC72700. • RDY (Valid only when SP is low.) 0: The RDY output is issued with timing 1. (default) 1: The RDY output is issued with timing 2. • DREQ (Valid only when SP is low.) 0: Negative logic is used for the polarity of the DREQ signal. (default) 1: Positive logic is used for the polarity of the DREQ signal. • DACK (Valid only when SP is low.) 0: Negative logic is used for the polarity of the DACK signal. (default) 1: Positive logic is used for the polarity of the DACK signal. No. 6167-13/29 LC72711W, 72711LW • BLK_RST 0: (default) 1: Resets the block synchronization circuit only. Sets the block synchronization status to unsynchronized and clears the block synchronization protection counter. However, note that this has no effect on the frame synchronization functions. Also note that during a synchronization block reset, the INT signal is not output and the DO pin outputs a high level (high-impedance). This flag is not automatically reset to 0. Applications must send a 0 value after setting this flag. • SUBBLK 0: Normal status. (default) 1: Set to 1 when a substation (for example a dGPS station during VICS reception) is temporarily received. RD Valid output DATn RDY timing 1 RDY timing 2 RDY Signal Output Timing Layer 4 CRC Register Address Register R/W Initial value 06H CRC4 W 00H BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 (LSB) This is the data group write register used for the layer 4 CRC check. It is used only when the parallel interface is used. Applications should specify the dedicated CCB address when using the serial interface. Status Register Address Register R/W Initial value BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 01H STAT R — VH BLK FRM ERR PRI HEAD CRC4 RTIB • VH 0: Indicates data for which only horizontal correction was performed. 1: Indicates data for which after horizontal correction, vertical and then second horizontal correction were performed as well. Packet data with an RTIB flag is output with VH set to 0. • BLK 0: Indicates data that was received with block synchronization unsynchronized. 1: Indicates data that was received with block synchronization synchronized. • FRM 0: Indicates data that was received with frame synchronization unsynchronized. 1: Indicates data that was received with frame synchronization synchronized. • ERR 0: Indicates data for which error correction completed and no errors were detected in the level 2 CRC check. 1: Indicates data for which error correction was not possible or for which errors were detected in the level 2 CRC check. • PRI 0: Indicates data that was inferred to be data block data by the frame synchronization circuit. 1: Indicates data that was inferred to be parity block data by the frame synchronization circuit. Packet data with an RTIB flag is output with PRI set to 0. No. 6167-14/29 LC72711W, 72711LW • HEAD 0: 1: Indicates data that was inferred to be in the frame head block by the frame synchronization circuit. This flag is valid only when VH is 0. • CRC4 0: Indicates that the layer 4 CRC detection circuit division registers were not all zeros. 1: Indicates that the layer 4 CRC detection circuit division registers were all zeros, i.e. that there were no errors. The result at the point immediately prior to register readout is loaded into this flag. • RTIB 0: 1: Indicates the data is a real-time information block. (This bit is valid only in method A'.) This bit is fixed at 0 during method A and method B reception. Block Number Register Address Register R/W Initial value BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 02H BLNO R — BLN7 BLN6 BLN5 BLN4 BLN3 BLN2 BLN1 BLN0 Indicates the block number or the parity block number of the output data. A single frame consists of data blocks numbered 0 to 189 and parity blocks numbered 0 to 81. Output following vertical correction does not include parity block data. The value of the block number register is undefined if VEC_HALT (bit 2 in control register 1) is set to 1. Data Update Timing for Read Registers The data in the two read registers (the status register at address 01H and the block number register at address 02H) is updated in the 1 ms interval between 1 ms prior to the output of the interrupt control signal (INT) and a point immediately before the INT output. In normal processing, when an interrupt occurs, the application will first determine the nature of the data packet that will be output by the current interrupt signal by reading out the status register, and determine if it is necessary to read out that data. For example, if error correction failed and the erroneous data is not required, the application should simply wait for the next interrupt. If the CCB interface is used, the application reads out the data from CCB address #FB, and determines the status from the additional 16 bits of data. It then either reads out the following data or sets the CE signal low to cancel the readout. Applications can also read out data asynchronously with respect to the interrupt signal. In this case, the application checks the current reception status by reading out the status register and checking bit 6 (data received in the block synchronized state) and bit 5 (data received in the frame synchronized state). In this case, using data for which bit 7 (VH) is 0 provides superior real time characteristics. No. 6167-15/29 LC72711W, 72711LW CPU Interface Timing <Parallel Mode> • Register Read Timing tWRDL1, tWRDL2 tCYRD A0 to A3 CS tSARD tHARD RD tDRDY RDY tWRDY tRDH Valid output DATn * tHARD stipulates the earliest timing for A0 to A3 and CS. • Register Write Timing tWWRL tCYWR A0 to A3 CS tSAWR tHAWR WR tWDH DATn No. 6167-16/29 LC72711W, 72711LW • Post-Correction Data Read Timing *: tWDRD1, tWDRD2 A0 to A3: When post-correction data is read, A0 to A3 will be held fixed at 0. tCYRD A0 to A3 CS tSARD tDRDY RD tWDRDY RDY tRDH Valid output DATn Valid output • Post-Correction Data Read Timing (DMA) tWRDM tDREQ DREQ DACK RD A0 to A3 CS tRDH DATn tCYDM *: A0 to A3: When post-correction data is read, A0 to A3 will be held fixed at 0. *: DREQ and DACK: The polarity of these signals can be set. *: Applications can select whether the DR or DACK signal is used for readout. No. 6167-17/29 LC72711W, 72711LW Layer 4 CRC Detection Circuit <Parallel Interface> This function provides data group error detection, i.e. layer 4 CRC. When the stipulated number of bytes of data group data and the CRC detection word (16 bits) are written to the layer 4 CRC register (address 6), if either the CRC4 pin outputs a high level or the CRC4 flag (bit 1 in the status register at address 1) is set to 1 then there were no errors in the data. The CRC4 pin or CRC4 flag in the status register outputs a high level, if the IC internal CRC detection register bits are all in the logic 0 state. When this function is used to perform a layer 4 CRC check, applications must initialize the IC internal CRC detection register before transferring the data for a single data group. This initialization is performed by sending data for bit 7 (CRC4_RST) in control register 1. Note that since this initialization flag is not automatically reset to 0, after the application sets this flag it must then send another data item that resets it to 0 before sending the layer 4 CRC check data. If there were no errors in all the received data groups, the CRC register will, necessarily, be all zeros after the CRC check for a given data group. Therefore, as long as there are no errors detected in the layer 4 CRC check, the application does not need to initialize the CRC detection register again using the control register as described above. There is no upper limit on the total data length of data groups that can be transferred. Also, when the serial interface issued, the CCB transfers can be divided into multiple transfer operations. The generating polynomial G(x) for the CRC code is as follows. G(x) = X16 + X12 + X5 + 1 Structure of the Post-Correction Output Data <Parallel Interface> The total length of the prepared output data is always 176 bits, i.e. 22 bytes. The layer 2 CRC data (14 bits) and the parity data (82 bits) are not output. The data in each packet in the post-correction data is output in order starting at the beginning in 8- or 16-bit units. BIC codes are not output. When the CPU reads out the data, it can easily select the data by checking the status register first. The CPU can then simply ignore data determined to be unnecessary without having to read it out by simply waiting until the next interrupt arrives. Data block (176 bits) Post-error correction data Parity (82 bits) Layer 2 CRC (14 bits) *: This data is not output. Structure of a Single Data Packet (Total length: 272 bits. BIC is not included.) CPU Interface <CCB Mode> CCB Format Data is input and output using the CCB (Computer Control Bus) format, which is Sanyo’s audio IC serial bus format. This IC uses an 8-bit address CCB with the address shown below. The CCB address is sent while CE is low, and the CCB I/O mode is determined when CE is set high. CCB address I/O mode B0 B1 B2 B3 A0 A1 A2 Item A3 Input 0 1 0 1 1 1 1 1 16-bit control data input Output 1 1 0 1 1 1 1 1 Data corresponding to the number of clock (CL) cycles is output Input 0 0 1 1 1 1 1 1 Data input mode for the layer 4 CRC detection circuit (8-bit units) Output 1 0 1 1 1 1 1 1 Register output only Data Input (Register Write) Data is stored in an IC internal register. The CCB address #FA and 16 bits of data (DI0 to DI15) are input to the DI pin. The bits are assigned as follows. Although DI12 to DI15 are unused data, arbitrary values must be provided to complete a full 16 bits of data. See the “Control Register” section earlier in this document for details on the register contents and addresses. Details on writing to the layer 4 CRC check register are described later in this document. (The CCB address #FC is used for this function.) DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 BIT0 BIT1 BIT2 BIT3 BIT4 BIT5 BIT6 BIT7 BIT0 BIT1 BIT2 BIT3 (LSB) Input data (8 bits) (MSB) Register address DI12 to DI15 Unused data No. 6167-18/29 LC72711W, 72711LW tEL tES CE tCH tEH tCL CL tSU tHD B0 DI B1 B2 B3 A0 A1 A2 A3 DI0 DI1 DI2 DI13 DI14 DI15 tLC Internal data latch operation Data Output (Post-Correction Data Output) The IC outputs packet data to which error correction processing has bee applied. The application inputs the CCB address #FB to DI. tES tEL CE tCH tCL CL tSU DI tHD B0 B1 B2 B3 A0 A1 A2 A3 tDDO DO0 DO DO1 DO2 DO285 DO286 DO287 *: The DO pin is normally left open. Since the DO pin is an n-channel open-drain output, the data change time from a low-level output to a high-level output differs due to the pull-up resistor. Structure of the Post-Correction Output Data <CCB Interface> Post-error correction data can be output by using CCB address #FB. Although there are up to 288 bits of valid data that can be output, it is possible to stop clock input (CL input) and set CE to the low level, and output the remaining data on the next interrupt with no harmful effects whatsoever. • The maximum amount of data that can be output is 288 bits (36 bytes), and the contents of the status register (STAT) and the block number register (BLNO) are added as the first two bytes. • The contents of the STAT and BLNO registers are output LSB first. • The post-correction data is output in order starting with the first bit in each single block of data. • The BIC code is not output. • The values of the output data are not guaranteed if multiple data read operations are performed for a single interrupt signal (INT). STAT (8 bits) BLNO (8 bits) DO0 to DO7 DO8 to DO15 Data section (176 bits) Post-error correction data DO16 to DO191 Layer 2 CRC (14 bits) Parity (82 bits) DO192 to DO205 DO206 to DO287 No. 6167-19/29 LC72711W, 72711LW Layer 4 CRC Check Circuit <CCB Interface> The basic outline of this operation is the same as that described in the Layer 4 CRC Detection Circuit <Parallel Interface> section earlier in this document. The data group data used for this error detection operation is sent to the IC using the CCB interface. The value #FC is used as the CCB address. The data group data is transferred in 8-bit units. There is no upper limit on the amount of data that can be transferred (the value N in the figure below), and the data transfer may be divided into multiple operations. tEL tES CE tEH tCL tCH CL tSU tHD B0 DI B1 B2 B3 A0 A1 A2 A3 CR0 CR1 CR2 N-2 N-1 N tCRC CRC4 pin output Note: The number of items, N, refers to the number of 8-bit items. CRC4 pin output after N items have been transferred. Register Output The IC internal status and block number registers are special-purpose registers that can be read out by applications. (See the discussion of the read register data update timing on page 15.) The application inputs the CCB address #FD to DI. The status register data is output first followed by the block number register data. tES tEL CE tCH tCL CL tSU DI tHD B0 B1 B2 B3 A0 A1 A2 A3 tDDO DO ST0 ST1 ST2 BLN5 BLN6 BLN7 No. 6167-20/29 LC72711W, 72711LW Notes on Operation during Resets and in Standby Mode Reset Signal The reset operation is executed when the supply voltage (VDD) rises above 3.4 V (2.5 V in the LC72711LW) and the RST pin input level is held at or below VIL for 300 ns or longer. (See the figure below.) When power is first applied, or when power is removed and applied again, always apply a reset before using this IC. 3.4 V (2.5 V in the LC72711LW) VDD voltage VIH RST VIL (0.3*VDD) 300 ns (min) Pin States during Reset Low level:CLK16 (5), DATA (6), FLOCK (7), BLOCK (8), FCK (9), BCK (10) High level: INT (33), RDY (16), CRC4 (11), DREQ (12) Open: D0 (17) to D15 (32), DO (36) Reset Operating Range The states of the output pins as the result of a reset signal are stipulated in the "Pin States during Reset" item above. The IC internal flip-flops are all reset. While the shift registers used for delay are also reset, the memory array is not influenced by this operation. However, since memory is not refreshed, data cannot be retained. The crystal oscillator circuit is not stopped. Post-Reset Data Input After a reset operation has completed, if at least one clock cycle (about 278 ns when the IC's main clock is 3.6 MHz) elapses, the register write circuit will be functional. (That is, the IC can accept data.) Notes on Standby Mode The IC is set to standby mode by applying a high level to the STNBY pin. Since all IC operations are stopped in this mode, the state is essentially equivalent to removing power from the IC. (Note that after clearing standby mode, applications must wait the oscillator stabilization time before using the IC.) The pin output states during standby mode are the same as those states during a reset as described above. Output Conditions for Post-Error Correction Output (Default Mode) (1) For each block (272 bits) of received data, the IC applies (272, 190) code error correction and a layer 2 CRC error check. After the error correction has completed, the IC prepares to transfer the data to the CPU and outputs an interrupt signal from the INT pin. This is referred to as horizontal correction output. (2) Note that under the default operating conditions, this interrupt signal is not output unless the corresponding output data meets the following three conditions. • Error correction completed correctly and no errors were discovered in the layer 2 CRC check. • The data was received in both block and frame synchronization. • The data is packet data. (3) If the data could not be corrected in horizontal correction, product code correction is performed in frame units and a second horizontal correction operation is performed for this data that could not be corrected by the first horizontal correction. This sequence of operations is called vertical correction. The output conditions for data that can be acquired after vertical correction are as follows. • The data that could not be corrected by horizontal correction only, but that was corrected by vertical correction. • The data is packet data. No. 6167-21/29 LC72711W, 72711LW This means that data that was fully corrected by horizontal correction is not output. Also, packet data that could not be corrected by either horizontal correction or vertical correction is not output. Furthermore, post-vertical correction parity packet data is also not output. (4) Applications can clear the INT signal selection conditions described in (2) and (3) above by setting bit 5 (INT_MOVE) in the control register. (5) Vertical correction is performed when all of the packet data in a frame is received in frame synchronization and furthermore when it was not possible to correct all of the packet (block) data with horizontal correction. Vertical correction is not performed if one frame of data with no errors was received or the receiver was not in frame synchronization during reception. To prevent incorrect correction, error correction using vertical correction is not performed for packets error correction using horizontal correction fully completed and for packets that had no errors. (6) Under the default settings, if vertical correction is not performed, the corresponding post-vertical correction output is not output. Applications can specify the post-vertical correction data to be output regardless of whether or not vertical correction is performed by setting bit 2 (VEC_OUT) in control register 2. Note 1. In this case, if data with absolutely no errors is received, completely identical data will be output twice, once as horizontal correction output, and once as vertical correction output. This status is identical to the output status of the LC72700E. Note 2. Immediately after power is applied, undefined data that is, in principle, not required by applications, will be output as post-vertical correction data. CPU Interface Basic Limitations To save internal memory, this IC limits its output data buffer to the smallest size possible. Since the data received by the IC is written to memory continuously without interruption, the post-correction data in the output data buffer that should be read out may be overwritten by the following data if readout of the data is delayed. The output timing for post-correction data, both horizontal and vertical, is stipulated as follows for this IC. (1) When the IC completes preparation of the output data, it drops the INT pin to the low level as a transfer request. (2) During data output, there are periods when only horizontal data can be read out, and there are other periods when both horizontal data and vertical data can be read out in a time-division multiplexed manner. (3) Applications must complete the data transfer operation within 9 ms after the INT pin goes low. If only posthorizontal correction data is output, the data transfer may be performed within an 18 ms period. After the stipulated period, the next data will be written to the output buffer replacing the previous data, even if the CPU is reading out the data. (4) The amount of data that can be read for a single transfer request (INT) for each of the horizontal and vertical data is one block only. The post-vertical correction data is output in order starting with block number 1 after vertical correction processing completes. The parity block data is not output. 18 ms INT Horizontal data only output Horizontal and vertical data output 1 ms Horizontal data output period Horizontal data output period Period during which data retention is not guaranteed 68 µs Vertical data output period 68 µs Figure 2 External Interface - Basic Timing No. 6167-22/29 LC72711W, 72711LW Notes on Data Output Timing (Relationship with the received data) Figure 3 shows the timing relationship between the received data and the interrupt control signal (INT). However, the delay from the actual received signal due to demodulation operations in MSK demodulation blocks is ignored. Block synchronization is established by discriminating the BIC code. As shown in figure 3, the data for the nth packet can be output during reception of the following packet (number n+1). Figure 4 shows the output timing for post-vertical correction data. In vertical correction, the data for a single frame is stored in memory and the correction operation is performed if frame synchronization was established and it was not possible to correct all the packet data in horizontal correction. The timing with which vertical correction is started is the start of the frame. Horizontal correction is performed for each packet while packets 1 through 28 in the nth frame are being received, and this data is passed to the CPU interface. Vertical correction is performed for the data from the previous frame (frame n-1) in the unused time periods during that processing. The vertical correction data consists of 190 blocks that are output, and this data is output at the rate of one block for every block received, in order starting at the time the 29th packet (block) is received. Only data from the data blocks in the FM multiplex broadcast frame structure is output, and the last block (block 190) is output during reception of the 218th block. As indicated previously (page 21) packet data that was, for example, corrected completely by horizontal correction, is not output in the vertical correction output data. (The INT signal is not issued.) However, the order in which the horizontal output is produced is not speeded up by the amount of the packet data that is not output. For example, if data packets 1 to 100 were corrected by horizontal correction, output of the post-vertical correction packet data for packet 101 will not occur at the reception position of block number 29 in figure 4, but at the reception position for packet data number 129. Packet n data Packet n-1 Received data Packet n+1 BIC BIC 18 ms 300 ns max 62.5 µs BCK 300 ns max INT Output period for packet n+1 data 1 ms 68 µs Data cannot be guaranteed Packet n data output Figure 3 Received Data, Block Synchronization, and Data Output Timing Received block signal First frame 271 272 nth frame 1 2 3 28 29 30 31 218 219 220 BCK 62.5 µs FCK 18 ms 1 2 189 190 INT 1 ms 18 ms 18 ms × 28 = 504 ms 9 ms 9 ms Output periods for post-vertical correction data from the previous frame. Figure 4 Post-Vertical Correction Data Output Timing No. 6167-23/29 LC72711W, 72711LW CPU Connection Example <Parallel Interface> This section presents examples of the connection of this IC to a CPU. Note that care is required with respect to read timing, since the time required to read a register, and the time required to read a post-correction data packet (22 bytes) are different. • Normal connection When hardware waits are applied to the CPU, the wait time (RDY width) requires care. BUSWD = low: 8 bits BUSWD = high: 16 bits LC72711W (LW) CPU D0 to D7 (D0 to D15) A0 to A3 WR RD CS WR RD CS INT INT RDY WAIT DREQ DACK IOCNT1 IOCNT2 BUSWD Bus-width 8 bits RST PORT1 SP • DMA transfer mode I/O read/write operations are used for the normal register read and write operations. However, programmable wait states may need to be inserted, depending on the execution speeds. DMA processing is only used for readout of post-correction data. Applications can select whether RD or DACK is used as the DMA read control signal by setting a register. The default is to use the RD signal. The data bus width in DMA mode is always 8 bits. LC72711W (LW) D0 to D7 A0 to A3 WR RD CS WR RD CS INT INT RDY DREQ DACK BUSWD IOCNT1 DREQ DACK Bus-width 8 bits IOCNT2 RST CPU DMA mode setting example (For reference only) SH Series: Transfer type: 2-cycle transfer Transfer mode: Single transfer mode V Series: Address mode: Dual address mode Bus mode: Cycle stealing mode The source side (the FM multiplex IC) address is fixed at 0. CPU PORT1 SP No. 6167-24/29 LC72711W, 72711LW • Data bus I/O control block The data bus (D0 to D15) can be controlled with two control signals: IOCNT1 and IOCNT2. These pins must be held low if unused. CS IOCNT1 IOCNT2 RD DACK Control register 2, bits 1 and 2 D0 to D15 CPU Connection Example <CCB Interface> CPU LC72711W (LW) A1/CE PORT1 A0/CL SCK * A2/DI TX * DO RX * INT PORT2 (INT) RST PORT3 SP *: SCK, TX, and RX are the CPU serial interface channel. Normally, I/O port pins may be used for these lines. * The resistance of the DO pin pull-up resistor must be selected according to the transfer clock speed. No. 6167-25/29 LC72711W, 72711LW Control Program Compatibility This IC allows the majority of the control software used to be compatible with Sanyo's other FM multiplex ICs, in particular, the LC72700E, LC72705E, LC72706E, LC72708E, and LC72709E(W). However, the following aspects of the control software require modification. • Values of the register addresses The addresses of the allowable BIC error count, synchronization error protection count, control registers, the layer 4 CRC register, and other registers have been modified. The CCB address for serial I/O over a CCB bus has not been changed. • INT signal output timing The INT signal output timing for data output is as follows. A circle ("O") indicates that INT is output, and a cross ("X") indicates that the signal is not output. Item Control register 1 bit 5, INT_MOVE Control register 2 bit 2, VEC_OUT Default value L L Combination 1 H Combination 2 Combination 3 Horizontal correction output Operational overview Vertical correction output Correct data Incorrect data Parity Correct data NG Operation identical to that of the LC72705/06/07E and LC72708/09E(W) ● × × ● *1 × H Operation identical to that of the LC72700E All data is output ● ● ● ● *2 ● H L The output data selection conditions are cleared, but there is no vertical correction output when vertical correction is not performed ● ● ● ● *3 ● L H The output data selection conditions are retained, but all of the vertical correction output is output ● × × ● ● Notes:1. Data for which horizontal correction failed, but for which vertical correction succeeded is output. 2. All data is output. 3. If there is data for which horizontal correction failed, the post-vertical correction data for that data is output, regardless of whether or not vertical correction succeeded. (If the IC performs vertical correction, post-vertical correction data will be output.) Notes on Output Data Selection after Tuning (Reference) When building an FM multiplex reception system, a tuning system is an absolute necessity. However, if it is unacceptable for the IC to output data from the old station after tuning to a new station, the application must perform the following processing. (1) At the same time as tuning a new station, the application must set bit 4 (SYNC_RST) in control register 1 to set the synchronization circuit to the unsynchronized state. (2) Under the default settings, after the synchronization reset applications must acquire data according to the issued INT signal. The post-vertical correction output is not provided by the IC until frame synchronization has been established for the new station after tuning and the first vertical correction operation has been performed. (3) If bit 2 (VEC_OUT) in control register 2 has been enabled, applications must not use the post-vertical correction output (data for which bit 7 in the status register is high) until frame synchronization has been reestablished. This IC performs the portion of the DARC FM multiplex processing through layer 2 error correction without requiring any special control operations. The IC itself cannot determine if the contents of the received data have changed or if a new station has been tuned. This means that applications must use the procedure described above for this IC not to output old data and only output the new data. Another point is that in IC synchronization, although it is rare for the old station and the new station to be frame synchronized, applications need to perform the processing in item 1 above to cancel frame synchronization forward protection period. No. 6167-26/29 LC72711W, 72711LW Sample Data Acquisition Flowchart Note: The figure below is for allocation of received data at the layer 3 level. This documentation is present as an example for reference purposes only of FM multiplex data acquisition processing by the system CPU. Its operation is not guaranteed. INT Status acquisition Correction complete? ** This discrimination is not required with the default settings. (No INT signal is issued.) Synchronized? Read in the postcorrection data (22 bytes) Was this post-horizontal correction data? Prefix discrimination Is the data group complete? Yes Prefix discrimination Is the data group complete? Yes Yes Is the decoding identifier 1? Yes Start decoding and presentation processing Layer 4 CRC check Start decoding and presentation processing Layer 4 CRC check End No. 6167-27/29 LC72711W, 72711LW Prefix discrimination Is this the data group for the first reception? Yes Allocate a storage area the size of the data group. Yes Update the data in the existing data storage area. Update? No Check the correctness of the received data packet. Resend? Yes No Is the data group complete? Store in the corresponding data group storage area. Yes End Additional Notes In addition to the above processing, processing required for layer 3 (data group) level processing includes “deletion of inappropriate data.” Although rare, in certain cases the IC will send inappropriate packet data that does not belong to any data group currently being broadcast. The following three points are possible reasons for this occurring. (1) The IC frame synchronization circuit generates an incorrect synchronization state, and the IC incorrectly outputs parity packet data as normal packet data. This can occur when the back protection count is less rigorous (2 or lower), or during weak field reception. (2) While extremely rare, incorrect correction can occur. (This almost never happens.) (3) Noise entering the data transfer lines between the FMD IC and the CPU within the end product set. Inappropriate packet data that occurs for these reasons and does not belong to any data group, will not be updated, and will remain in the program storage memory indefinitely. If the application does not include a routine that searches for and deletes inappropriate data, program storage memory will overflow at some point. Also, applications should perform a layer 4 CRC check after data group completion and before program display. No. 6167-28/29 LC72711W, 72711LW • The DARC (Data Radio Channel) FM multiplex broadcast technology was developed by NHK (Japan Broadcasting Corporation). • DARC is a registered trademark of NHK Engineering Service (NHK-ES). • A separate contract with NHK-ES is required in advance for the manufacture and/or sale of electronic equipment that uses DARC technology. • The logo shown here can be displayed on electronic equipment that uses DARC technology. • Sanyo Electric Co., Ltd. has reported to NHK-ES the number of units and purchasers of ICs that use DARC technology shipped since October 1997. Specifications of any and all SANYO products described or contained herein stipulate the performance, characteristics, and functions of the described products in the independent state, and are not guarantees of the performance, characteristics, and functions of the described products as mounted in the customer’s products or equipment. To verify symptoms and states that cannot be evaluated in an independent device, the customer should always evaluate and test devices mounted in the customer’s products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. In the event that any or all SANYO products (including technical data, services) described or contained herein are controlled under any of applicable local export control laws and regulations, such products must not be exported without obtaining the export license from the authorities concerned in accordance with the above law. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or any information storage or retrieval system, or otherwise, without the prior written permission of SANYO Electric Co., Ltd. Any and all information described or contained herein are subject to change without notice due to product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification” for the SANYO product that you intend to use. Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties. This catalog provides information as of January, 2000. Specifications and information herein are subject to change without notice. PS No. 6167-29/29