ETC G5V-2

Low Signal Relay
G5V-2
Suitable for handling low signals in
computer peripherals, telecommunications and security equipment
■ Capable of switching loads up to 2 A
■ Conforms to FCC part 68 1500 V surge
withstand
■ Reliable bifurcated crossbar contacts
■
■
Fully-sealed construction
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12).
Type
Standard
High-sensitivity
Ultra-sensitive
Contact form
DPDT
Construction
Fully-sealed
Specifications
■ CONTACT DATA
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Resistive load (p.f. = 1)
0.50 A at 125 VAC
2 A at 30 VDC
Ag (Au clad)
2A
125 VAC
125 VDC
2A
62.50 VA
60W
10 µA, 10 mVDC
Part number
G5V-2
G5V-2-H
G5V-2-H1
G5V-2
G5V-2
■ COIL DATA
Standard type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Armature OFF
Armature ON
% of rated voltage
3
5
6
9
12
24
48
166.70
100
83.30
55.60
41.70
20.80
12
18
50
72
162
288
1,152
4,000
0.04
0.09
0.16
0.31
0.47
1.98
—
0.05
0.11
0.19
0.49
0.74
2.68
—
75% max.
Coil inductance
(Ref. value) (H)
5% min.
Maximum
voltage
Power
consumption
(mW)
120% max. Approx. 500
at 65°C
(149°F)
110% max. Approx. 580
at 60°C
(140°F)
High-sensitivity type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
5
6
9
12
24
48
120
72
60
40
30
15
7.5
25
70
100
225
400
1,600
6,400
Armature OFF
0.04
0.12
0.18
0.40
0.75
3.16
—
Pick-up
voltage
Armature ON
0.07
0.19
0.29
0.62
1.18
4.81
—
Dropout
voltage
% of rated voltage
75% max. 5% min.
Maximum
voltage
Power
consumption
(mW)
120% max. Approx. 360
at 70°C
(158°F)
110% max.
at 70°C
(158°F)
Ultra-sensitive type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
5
6
9
12
24
48
50
30
25
16.70
12.50
8.30
6.25
60
166.70
240
540
960
2,880
7,680
Coil inductance
(Ref. value) (H)
Armature OFF
0.18
0.46
0.70
1.67
2.90
6.72
20.10
Pick-up
voltage
Armature ON
0.26
0.71
0.97
2.33
3.99
9.27
26.70
Dropout
voltage
% of rated voltage
75% max. 5% min.
Maximum
voltage
Power
consumption
(mW)
150% max. Approx. 150
at 70°C
(158°F)
Approx. 200
Approx. 300
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
2
G5V-2
G5V-2
■ CHARACTERISTICS
Contact resistance
Operate time
Release time
Bounce time
Operating frequency
50 mΩ max. G5V-2, G5V-2-H, 100 mΩ max. G5V-2-H1
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
Mean value: approx. 0.5 ms
Mean value: approx. 3.5 ms
Operate
Release
Mechanical
Electrical
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Ambient temperature Operating/storage
Humidity
Service life
Mechanical
Electrical
Weight
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for
ultra-sensitive type)
1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
1,000 m/s2 (approx. 100 G)
200 m/s2 (approx. 20 G)
-25° to 70°C (-13° to 158°F)
35% to 85% RH
15 million operations min. (at operating frequency of 36,000 operations/hour)
See “Characteristic Data”
6 g (0.21 oz)
Note: Data shown are of initial value.
■ CHARACTERISTIC DATA
Electrical service life
Rated operating voltage (V)
Ambient temperature vs.
maximum voltage
Maximum voltage (%)
Rated operating current (A)
Service life (x103 operations)
Maximum switching capacity
Rated operating current (A)
Ambient temperature [°C (°F)]
---- 48 VDC coil voltage (standard type)
All other types and voltages
3
G5V-2
G5V-2
Dimensions
Unit: mm (inch)
■ RELAYS
Fully-sealed
Terminal arrangement/Internal
(bottom view)
Mounting holes
(bottom view)
123456
123456
Note: 1. 123456 and
indicate mounting orientation marks.
2. A tolerance of ±0.10 (0.004) applies to the above dimensions.
■ APPROVALS
UL (File No. E41515)/CSA (File No. LR24825)
Type
G5V-2
G5V-2-H
Contact form
DPDT
G5V-2-H1
Coil rating
3 to 48 VDC
3 to 24 VDC
3 to 48 VDC
Contact ratings
0.6 A, 125 VAC
0.6 A,110 VDC
2.0 A, 30 VDC
0.6 A, 125 VAC
0.6 A, 110 VDC
1.0 A, 24 VDC
Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually
defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external
spacings).
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
4
01/00
Specifications subject to change without notice.
Printed in the U.S.A.