Low Signal Relay G5V-2 Suitable for handling low signals in computer peripherals, telecommunications and security equipment ■ Capable of switching loads up to 2 A ■ Conforms to FCC part 68 1500 V surge withstand ■ Reliable bifurcated crossbar contacts ■ ■ Fully-sealed construction Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12). Type Standard High-sensitivity Ultra-sensitive Contact form DPDT Construction Fully-sealed Specifications ■ CONTACT DATA Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 0.50 A at 125 VAC 2 A at 30 VDC Ag (Au clad) 2A 125 VAC 125 VDC 2A 62.50 VA 60W 10 µA, 10 mVDC Part number G5V-2 G5V-2-H G5V-2-H1 G5V-2 G5V-2 ■ COIL DATA Standard type Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (Ref. value) (H) Pick-up voltage Dropout voltage Armature OFF Armature ON % of rated voltage 3 5 6 9 12 24 48 166.70 100 83.30 55.60 41.70 20.80 12 18 50 72 162 288 1,152 4,000 0.04 0.09 0.16 0.31 0.47 1.98 — 0.05 0.11 0.19 0.49 0.74 2.68 — 75% max. Coil inductance (Ref. value) (H) 5% min. Maximum voltage Power consumption (mW) 120% max. Approx. 500 at 65°C (149°F) 110% max. Approx. 580 at 60°C (140°F) High-sensitivity type Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 3 5 6 9 12 24 48 120 72 60 40 30 15 7.5 25 70 100 225 400 1,600 6,400 Armature OFF 0.04 0.12 0.18 0.40 0.75 3.16 — Pick-up voltage Armature ON 0.07 0.19 0.29 0.62 1.18 4.81 — Dropout voltage % of rated voltage 75% max. 5% min. Maximum voltage Power consumption (mW) 120% max. Approx. 360 at 70°C (158°F) 110% max. at 70°C (158°F) Ultra-sensitive type Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 3 5 6 9 12 24 48 50 30 25 16.70 12.50 8.30 6.25 60 166.70 240 540 960 2,880 7,680 Coil inductance (Ref. value) (H) Armature OFF 0.18 0.46 0.70 1.67 2.90 6.72 20.10 Pick-up voltage Armature ON 0.26 0.71 0.97 2.33 3.99 9.27 26.70 Dropout voltage % of rated voltage 75% max. 5% min. Maximum voltage Power consumption (mW) 150% max. Approx. 150 at 70°C (158°F) Approx. 200 Approx. 300 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C (73°F). 2 G5V-2 G5V-2 ■ CHARACTERISTICS Contact resistance Operate time Release time Bounce time Operating frequency 50 mΩ max. G5V-2, G5V-2-H, 100 mΩ max. G5V-2-H1 7 ms max. (mean value: approx. 3.5 ms) 3 ms max. (mean value: approx. 0.8 ms) Mean value: approx. 0.5 ms Mean value: approx. 3.5 ms Operate Release Mechanical Electrical Insulation resistance Dielectric strength Surge withstand voltage Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating/storage Humidity Service life Mechanical Electrical Weight 36,000 operations/hour 1,800 operations/hour (under rated load) 1,000 MΩ min (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 750 VAC, 50/60 Hz for 1 minute between contacts of same poles (500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type) 1,500 V 10 X 160 µs (conforms to part 68 of FCC rules) 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude 1,000 m/s2 (approx. 100 G) 200 m/s2 (approx. 20 G) -25° to 70°C (-13° to 158°F) 35% to 85% RH 15 million operations min. (at operating frequency of 36,000 operations/hour) See “Characteristic Data” 6 g (0.21 oz) Note: Data shown are of initial value. ■ CHARACTERISTIC DATA Electrical service life Rated operating voltage (V) Ambient temperature vs. maximum voltage Maximum voltage (%) Rated operating current (A) Service life (x103 operations) Maximum switching capacity Rated operating current (A) Ambient temperature [°C (°F)] ---- 48 VDC coil voltage (standard type) All other types and voltages 3 G5V-2 G5V-2 Dimensions Unit: mm (inch) ■ RELAYS Fully-sealed Terminal arrangement/Internal (bottom view) Mounting holes (bottom view) 123456 123456 Note: 1. 123456 and indicate mounting orientation marks. 2. A tolerance of ±0.10 (0.004) applies to the above dimensions. ■ APPROVALS UL (File No. E41515)/CSA (File No. LR24825) Type G5V-2 G5V-2-H Contact form DPDT G5V-2-H1 Coil rating 3 to 48 VDC 3 to 24 VDC 3 to 48 VDC Contact ratings 0.6 A, 125 VAC 0.6 A,110 VDC 2.0 A, 30 VDC 0.6 A, 125 VAC 0.6 A, 110 VDC 1.0 A, 24 VDC Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY7 4 01/00 Specifications subject to change without notice. Printed in the U.S.A.