SEMTECH LC04-6TE

LC04-6
Dual Low Capacitance TVS Array for
Telecom Linecard Applications
PROTECTION PRODUCTS
Description
Features
u Transient protection for high-speed data lines to
The LC04-6 has been specifically designed to protect
sensitive components which are connected to highspeed telecommunications lines from over voltages
caused by lightning, ESD (electrostatic discharge), and
EFT (electrical fast transients).
The device is in a JEDEC SO-16 NB package. It is
designed to provide metallic surge protection for two
tip & ring line pairs. The low capacitance topology
means signal integrity is preserved on high-speed lines.
The high surge capability (1000W, tp=10/1000µs)
makes the LC04-6 suitable for telecommunications
systems operating in harsh transient environments.
The LC04-6 is designed to meet the lightning surge
requirements of Bellcore GR-1089 (Intra-building) , FCC
Part 68, ITU K.20, and IEC 61000-4-5. The features of
the LC04-6 are ideal for protecting T1/E1 transceivers
in WAN applications.
u
u
u
u
u
Bellcore GR-1089 IPP=70A (10/1000µs)
Bellcore GR 1089 IPP=100A (2/10µs)
ITU K.20 IPP=100A (5/310µs)
IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
IEC 61000-4-5 (Lightning) IPP=100A (8/20µs)
Protects two tip and ring line pairs
Low capacitance for high-speed interfaces
High surge capability
Low clamping voltage
Solid-state silicon avalanche technology
Mechanical Characteristics
u
u
u
u
JEDEC SO-16 package
Molding compound flammability rating: UL 94V-0
Marking : Part number, date code, logo
Packaging : Tube or Tape and Reel per EIA 481
Applications
u
u
u
u
u
u
u
u
Circuit Diagram
T1/E1 Line Cards
Base Stations
WAN Equipment
CSU/DSU
Multiplexers
Routers
ISP Equipment
Customer Premise Equipment
Schematic & PIN Configuration
TIP
RING
SO-16 (Top View)
Revision 9/2000
1
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Absolute Maximum Rating
R ating
Symbo l
Value
Units
Peak Pulse Pow er (tp = 10/1000µ s)
Pp k
1000
Watts
Peak Pulse Current (tp = 10/1000 µ s)
I PP
70
A
Peak Pulse Current (tp = 8/20µ s)
I PP
200
A
Peak Pulse Current (tp = 10/560µ s)
I PP
100
A
Lead Sold ering Temp erature
TL
260 (10 sec.)
°C
Op erating Temp erature
TJ
-55 to +125
°C
TSTG
-55 to +150
°C
Storage Temp erature
Electrical Characteristics
LC04-6
Par ame te r
Symbo l
Co nd itio ns
Minimum
Typ ical
Maximum
Units
6
V
Reverse Stand -Off Voltage
V RWM
Reverse Breakd ow n Voltage
V BR
It = 1mA
IR
V RWM = 6V, T=25°C
15
µA
V RWM = 3V, T=25°C
2
µA
Reverse Leakage Current
6.8
V
Clamp ing Voltage
VC
IPP = 10A ,
tp = 10/1000µ s
12.5
V
Clamp ing Voltage
VC
IPP = 70A ,
tp = 10/1000µ s
15
V
Clamp ing Voltage
VC
IPP = 100A ,
tp = 8/20µ s
20
V
Junction Cap acitance
Cj
Each Line
V R = 0V, f = 1MHz
15
pF
ã 2000 Semtech Corp.
2
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Typical Characteristics
Non-Repetitive Peak Pulse Power vs. Pulse Time
Power Derating Curve
100
110
% of Rated Power or IPP
Peak Pulse Power - P PP (kW)
100
10
90
80
70
60
50
40
30
20
10
0
1
0.1
1
10
100
0
1000
25
50
75
100
125
150
Ambient Temperature - TA (oC)
Pulse Duration - tp (µs)
Pulse Waveform
Clamping Voltage vs. Peak Pulse Current
110
Waveform
Parameters:
tr = 8µs
td = 20µs
90
Percent of IPP
80
70
e
60
14
Clamping Voltage - V C (V)
100
-t
50
40
td = IPP/2
30
20
12
10
8
6
Waveform
Parameters:
tr = 10µs
td = 1000µs
4
2
10
0
0
0
5
10
15
20
25
0
30
10
20
30
40
50
60
70
80
Peak Pulse Current - IPP (A)
Time (µs)
Capacitance vs. Reverse Voltage
(Each Line)
14
Capacitance (pF)
12
10
8
6
4
2
f=1MHz
0
0
1
2
3
4
5
6
7
Reverse Voltage (V)
ã 2000 Semtech Corp.
3
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Applications Information
Device Connection Options for Protection of Two
High-Speed Line Pairs
Figure 1 - Connection for Differential (Line-to-Line)
Protection of two Tip/Ring Line Pairs
The LC04-6 is designed to protect four high-speed data
lines (two differential pairs) from transient over-voltages which result from lightning and ESD. Protection
of two line pairs is achieved by connecting the device
as follows: Pins 1-4 are connected to line 1 of the first
pair (i.e. Tip 1) and pins 13-16 are connected to line 2
of the first pair (i.e. Ring 1). Pins 5-8 are connected to
line 1 of the second pair (i.e. Tip 2) and pins 9-12 are
connected to line two of the second pair (i.e. Ring 2).
All pins should be connected for best results. Minimize
parasitic inductance in the protection circuit path by
keeping the trace length between the protected line
and the LC04-6 as short as possible.
TIP 1
RING 1
TIP 2
RING 2
T1/E1 Linecard Protection
A typical T1/E1 linecard protection circuit is shown in
Figure 2. The LC04-6 is connected between Tip & Ring
on the transmit and receive line pairs. It provides
protection to metallic (line-to-line) lightning and ESD
surges. It is designed to meet the intra-building requirements of Bellcore GR-1089. This design takes
advantage of the isolation of the transformer to
suppress common mode surges. The LC04-6 may also
be configured to meet metallic surges of FCC Part68
when used in conjunction with a 5W (minimum) PTC or
line feed resistor (LFR). The PTC (or LFR + fuse) are
required to meet the AC power cross requirements, but
will also reduce the effective surge current to levels
within the capability of the LC04-6 (Table 1). To complete the protection circuit, the SRDA05-4 (or
SRDA3.3-4 for 3.3V supplies) is employed as the IC
side protection element. This device helps prevent the
transceiver from latching up by providing fine clamping
of transients that are coupled through the transformer.
The versatility of the LC04-6 makes it ideal for use with
combination long haul/short haul T1/E1 transceivers.
ã 2000 Semtech Corp.
4
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Typical Applications
Figure 2 - T1 Line Card protection
Immunity
Stand ar d
Pe ak Op e n
Cir cuit Sur ge
Vo ltage
Cur r e nt
Wave fo r m
(µs)
Pe ak Sho r t
Cir cuit
Sur ge
Cur r e nt
(A)
Sur ge
Ge ne r ato r
So ur ce
R e sistance
(W)
To tal So ur ce
R e sistance
(with 5W PTC o r
LFC)
(W)
Effe ctive
Sho r t
Sir cuit
Cur r e nt
(A)
( V)
Be llco r e GR -1089
Intr a-Build ing
800
2/10
100
8
13
61.5
FCC Par t 68
1500
10/160
200
7.5
12.5
120
Table 1
ã 2000 Semtech Corp.
5
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Outline Drawing - SO-16
Land Pattern - SO-16
ã 2000 Semtech Corp.
6
www.semtech.com
LC04-06
PROTECTION PRODUCTS
Ordering Information
P ar t
Numbe r
Wo r king
Vo ltage
Qty p e r
Reel
R e e l Size
LC04-6.TB
6V
500
7 Inch
LC04-6.TE
6V
2500
13 Inch
Note:
(1) No suffix indicates tube pack.
Contact Information
Semtech Corporation
Protection Products Division
652 Mitchell Rd., Newbury Park, CA 91320
Phone: (805)498-2111 FAX (805)498-3804
ã 2000 Semtech Corp.
7
www.semtech.com