M58CR064C, M58CR064D M58CR064P, M58CR064Q 64 Mbit (4Mb x 16, Dual Bank, Burst ) 1.8V Supply Flash Memory FEATURES SUMMARY ■ SUPPLY VOLTAGE Figure 1. Package – VDD = 1.65V to 2V for Program, Erase and Read – VDDQ = 1.65V to 3.3V for I/O Buffers – VPP = 12V for fast Program (optional) ■ SYNCHRONOUS / ASYNCHRONOUS READ – Synchronous Burst Read mode : 54MHz FBGA – Asynchronous/ Synchronous Page Read mode – Random Access: 85, 90, 100, 120ns ■ PROGRAMMING TIME – 10µs by Word typical TFBGA56 (ZB) 6.5 x 10mm – Double/Quadruple Word Program option ■ MEMORY BLOCKS – Dual Bank Memory Array: 16/48 Mbit – Parameter Blocks (Top or Bottom location) ■ DUAL OPERATIONS – Program Erase in one Bank while Read in other – No delay between Read and Write operations ■ BLOCK LOCKING – All blocks locked at Power up – Any combination of blocks can be locked ■ ELECTRONIC SIGNATURE – Manufacturer Code: 20h – Top Device Code, M58CR064C: 88CAh – Bottom Device Code, M58CR064D: 88CBh – Top Device Code, M58CR064P: 8801h – Bottom Device Code, M58CR064Q: 8802h – WP for Block Lock-Down ■ SECURITY – 128 bit user programmable OTP cells – 64 bit unique device number – One parameter block permanently lockable ■ COMMON FLASH INTERFACE (CFI) ■ 100,000 PROGRAM/ERASE CYCLES per BLOCK June 2003 1/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q TABLE OF CONTENTS SUMMARY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 2. Logic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Table 1. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 3. TFBGA Connections (Top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 2. Bank Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 4. Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SIGNAL DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Address Inputs (A0-A21). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Data Input/Output (DQ0-DQ15). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Chip Enable (E). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Output Enable (G). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Write Enable (W). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Write Protect (WP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Reset/Power-Down (RP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Latch Enable (L). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Clock (K).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Wait (WAIT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VDD Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VDDQ Supply Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VPP Program Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VSS Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VSSQ Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 BUS OPERATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Bus Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Bus Write. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Address Latch.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Output Disable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Standby. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 3. Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 COMMAND INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 4. Command Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 COMMAND INTERFACE - STANDARD COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Read Array Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Read Status Register Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Read Electronic Signature Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Read CFI Query Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Clear Status Register Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Block Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Program/Erase Suspend Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Program/Erase Resume Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Protection Register Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Set Configuration Register Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Block Lock Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Block Unlock Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Block Lock-Down Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 5. Standard Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 6. Electronic Signature Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 5. Security Block and Protection Register Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 COMMAND INTERFACE - FACTORY PROGRAM COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . 18 Bank Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Double Word Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Quadruple Word Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table 7. Factory Program Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 STATUS REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Program/Erase Controller Status Bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Erase Suspend Status Bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Erase Status Bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Program Status Bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 VPP Status Bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Program Suspend Status Bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Block Protection Status Bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Reserved Bit (SR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 8. Status Register Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 CONFIGURATION REGISTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Read Select Bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 X-Latency Bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Power-Down Bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Wait Configuration Bit (CR8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Burst Type Bit (CR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Valid Clock Edge Bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Wrap Burst Bit (CR3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Burst length Bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 9. Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 10. Burst Type Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Figure 6. X-Latency and Data Output Configuration Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 7. Wait Configuration Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 READ MODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Asynchronous Read Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Synchronous Burst Read Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Single Synchronous Read Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q DUAL OPERATIONS AND MULTIPLE BANK ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 11. Dual Operations Allowed In Other Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 12. Dual Operations Allowed In Same Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 BLOCK LOCKING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Reading a Block’s Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Locked State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Unlocked State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Lock-Down State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Locking Operations During Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 13. Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 PROGRAM AND ERASE TIMES AND ENDURANCE CYCLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 14. Program, Erase Times and Program, Erase Endurance Cycles . . . . . . . . . . . . . . . . . . . 30 MAXIMUM RATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 15. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 DC and AC PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 16. Operating and AC Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 8. AC Measurement I/O Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 9. AC Measurement Load Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 17. Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 18. DC Characteristics - Currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 19. DC Characteristics - Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 10. Asynchronous Random Access Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 11. Asynchronous Page Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 20. Asynchronous Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 12. Synchronous Burst Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 13. Single Synchronous Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Table 21. Synchronous Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 14. Write AC Waveforms, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Table 22. Write AC Characteristics, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 15. Write AC Waveforms, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Table 23. Write AC Characteristics, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Figure 16. Reset and Power-up AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Table 24. Reset and Power-up AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 PACKAGE MECHANICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Figure 17. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Bottom View Package Outline. . 46 Table 25. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Package Mechanical Data . . . . . 46 Figure 18. TFBGA56 Daisy Chain - Package Connections (Top view through package) . . . . . . . . 47 Figure 19. TFBGA56 Daisy Chain - PCB Connection Proposal (Top view through package). . . . . 48 PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Table 26. Ordering Information Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 4/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 27. Daisy Chain Ordering Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 APPENDIX A. BLOCK ADDRESS TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Table 28. Top Boot Block Addresses, M58CR064C, M58CR064P . . . . . . . . . . . . . . . . . . . . . . . . . 50 Table 29. Bottom Boot Block Addresses, M58CR064D, M58CR064Q . . . . . . . . . . . . . . . . . . . . . . 52 APPENDIX B. COMMON FLASH INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Table 30. Query Structure Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Table 31. CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Table 32. CFI Query System Interface Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Table 33. Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Table 34. Primary Algorithm-Specific Extended Query Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Table 35. Burst Read Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 APPENDIX C. FLOWCHARTS AND PSEUDO CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Figure 20. Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Figure 21. Double Word Program Flowchart and Pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Figure 22. Quadruple Word Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . 60 Figure 23. Program Suspend & Resume Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . 61 Figure 24. Block Erase Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Figure 25. Erase Suspend & Resume Flowchart and Pseudo Code. . . . . . . . . . . . . . . . . . . . . . . . 63 Figure 26. Locking Operations Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Figure 27. Protection Register Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . 65 APPENDIX D. COMMAND INTERFACE STATE TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Table 36. Command Interface States - Lock table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Table 37. Command Interface States - Modify Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 REVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Table 38. Document Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 5/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q SUMMARY DESCRIPTION The M58CR064 is a 64 Mbit (4Mbit x16) non-volatile Flash memory that may be erased electrically at block level and programmed in-system on a Word-by-Word basis using a 1.65V to 2V VDD supply for the circuitry and a 1.65V to 3.3V VDDQ supply for the Input/Output pins. An optional 12V VPP power supply is provided to speed up customer programming. In M58CR064C and M58CR064D the VPP pin can also be used as a control pin to provide absolute protection against program or erase. In M58CR064P and M58CR064Q this feature is disabled. The device features an asymmetrical block architecture. M58CR064 has an array of 135 blocks, and is divided into two banks, Banks A and B. The Dual Bank Architecture allows Dual Operations, while programming or erasing in one bank, Read operations are possible in the other bank. Only one bank at a time is allowed to be in Program or Erase mode. It is possible to perform burst reads that cross bank boundaries. The bank architecture is summarized in Table 2, and the memory maps are shown in Figure 4. The Parameter Blocks are located at the top of the memory address space for the M58CR064C and M58CR064P, and at the bottom for the M58CR064D and M58CR064Q. Each block can be erased separately. Erase can be suspended, in order to perform program in any other block, and then resumed. Program can be suspended to read data in any other block and then resumed. Each block can be programmed and erased over 100,000 cycles using the supply voltage V DD. Program and Erase commands are written to the Command Interface of the memory. An internal Program/Erase Controller takes care of the timings necessary for program and erase operations. 6/70 The end of a program or erase operation can be detected and any error conditions identified in the Status Register. The command set required to control the memory is consistent with JEDEC standards. The device supports synchronous burst read and asynchronous read from all blocks of the memory array; at power-up the device is configured for asynchronous read. In synchronous burst mode, data is output on each clock cycle at frequencies of up to 54MHz. The M58CR064 features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency, enabling instant code and data protection. All blocks have three levels of protection. They can be locked and locked-down individually preventing any accidental programming or erasure. In M58CR064C and M58CR064D there is an additional hardware protection against program and erase. When VPP ≤ VPPLK all blocks are protected against program or erase. All blocks are locked at Power- Up. The device includes a Protection Register and a Security Block to increase the protection of a system’s design. The Protection Register is divided into two segments: a 64 bit segment containing a unique device number written by ST, and a 128 bit segment One-Time-Programmable (OTP) by the user. The user programmable segment can be permanently protected. The Security Block, parameter block 0, can be permanently protected by the user. Figure 5, shows the Security Block and Protection Register Memory Map. The memory is offered in a TFBGA56, 6.5 x 10mm, 0.75 mm ball pitch package and is supplied with all the bits erased (set to ’1’). M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 2. Logic Diagram Table 1. Signal Names VDD VDDQ VPP 22 16 A0-A21 DQ0-DQ15 W E G RP WAIT M58CR064C M58CR064D M58CR064P M58CR064Q WP L K VSS A0-A21 Address Inputs DQ0-DQ15 Data Input/Outputs, Command Inputs E Chip Enable G Output Enable W Write Enable RP Reset/Power-Down WP Write Protect K Clock L Latch Enable WAIT Wait VDD Supply Voltage VDDQ Supply Voltage for Input/Output Buffers VPP Optional Supply Voltage for Fast Program & Erase VSS Ground VSSQ Ground Input/Output Supply NC Not Connected Internally VSSQ AI90000 7/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 3. TFBGA Connections (Top view through package) 1 2 3 4 5 6 7 8 A A11 A8 VSS VDD VPP A18 A6 A4 B A12 A9 A20 K RP A17 A5 A3 C A13 A10 A21 L W A19 A7 A2 D A15 A14 WAIT A16 DQ12 WP NC A1 E VDDQ DQ15 DQ6 DQ4 DQ2 DQ1 E A0 F VSS DQ14 DQ13 DQ11 DQ10 DQ9 DQ0 G G DQ7 VSSQ DQ5 VDD DQ3 VDDQ DQ8 VSSQ AI90001 Table 2. Bank Architecture 8/70 Bank Size Parameter Blocks Main Blocks Bank A 16 Mbit 8 blocks of 4 KWord 31 blocks of 32 KWord Bank B 48 Mbit - 96 blocks of 32 KWord M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 4. Memory Map Top Boot Block Address lines A21-A0 000000h 007FFFh Bottom Boot Block Address lines A21-A0 000000h 512 Kbit or 32 KWord 000FFFh 64 Kbit or 4 KWord Total of 8 Parameter Blocks (bottom bank) Total of 96 Main Blocks (bottom bank) Bank B 2F8000h 2FFFFFh 300000h 307FFFh 007000h 512 Kbit or 32 KWord Bank A 512 Kbit or 32 KWord 007FFFh 008000h 00FFFFh 64 Kbit or 4 KWord 512 Kbit or 32 KWord Total of 31 Main Blocks (bottom bank) Total of 31 Main Blocks (top bank) 3F0000h Bank A 3F7FFFh 3F8000h 3F8FFFh 0F8000h 512 Kbit or 32 KWord 0FFFFFh 100000h 64 Kbit or 4 KWord 107FFFh Total of 8 Parameter Blocks (top bank) 3FF000h 3FFFFFh 64 Kbit or 4 KWord 512 Kbit or 32 KWord 512 Kbit or 32 KWord Total of 96 Main Blocks (top bank) Bank B 3F8000h 3FFFFFh 512 Kbit or 32 KWord AI90002 9/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q SIGNAL DESCRIPTIONS See Figure 2 Logic Diagram and Table 1,Signal Names, for a brief overview of the signals connected to this device. Address Inputs (A0-A21). The Address Inputs select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the Command Interface of the internal state machine. Data Input/Output (DQ0-DQ15). The Data I/O outputs the data stored at the selected address during a Bus Read operation or inputs a command or the data to be programmed during a Bus Write operation. Chip Enable (E). The Chip Enable input activates the memory control logic, input buffers, decoders and sense amplifiers. When Chip Enable is at VILand Reset/Power-Down is at VIH the device is in active mode. When Chip Enable is at VIH the memory is deselected, the outputs are high impedance and the power consumption is reduced to the stand-by level. Output Enable (G). The Output Enable controls the outputs during the Bus Read operation of the memory. Write Enable (W). The Write Enable controls the Bus Write operation of the memory’s Command Interface. The data and address inputs are latched on the rising edge of Chip Enable or Write Enable whichever occurs first. Write Protect (WP). Write Protect is an input that gives an additional hardware protection for each block. When Write Protect is at VIL, the LockDown is enabled and the protection status of the Locked-Down blocks cannot be changed. When Write Protect is at VIH, the Lock-Down is disabled and the Locked-Down blocks can be locked or unlocked. (refer to Table 13, Lock Status). Reset/Power-Down (RP). The Reset/PowerDown input provides a hardware reset of the memory, and/or Power-Down functions, depending on the Configuration Register status. When Reset/ Power-Down is at VIL, the memory is in reset mode: the outputs are high impedance and if the Power-Down function is enabled the current consumption is reduced to the Reset Supply Current IDD2. Refer to Table 18, DC Characteristics - Currents for the value of IDD2. After Reset all blocks are in the Locked state and the Configuration Register is reset. When Reset/Power-Down is at VIH, the device is in normal operation. Exiting reset mode the device enters asynchronous read mode, but a negative transition of Chip Enable or Latch Enable is required to ensure valid data outputs. The Reset/Power-Down pin can be interfaced with 3V logic without any additional circuitry. It can be 10/70 tied to V RPH (refer to Table 19, DC Characteristics). Latch Enable (L). Latch Enable latches the address bits on its rising edge. The address latch is transparent when Latch Enable is at VIL and it is inhibited when Latch Enable is at VIH. Latch Enable can be kept Low (also at board level) when the Latch Enable function is not required or supported. Clock (K). The clock input synchronizes the memory to the microcontroller during synchronous read operations; the address is latched on a Clock edge (rising or falling, according to the configuration settings) when Latch Enable is at VIL. Clock is don't care during asynchronous read and in write operations. Wait (WAIT). Wait is an output signal used during synchronous read to indicate whether the data on the output bus are valid. This output is high impedance when Chip Enable or Output Enable are at VIH or Reset/Power-Down is at V IL. It can be configured to be active during the wait cycle or one clock cycle in advance. VDD Supply Voltage. VDD provides the power supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase). VDDQ Supply Voltage. VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered independently from VDD. VDDQ can be tied to VDD or can use a separate supply. VPP Program Supply Voltage. VPP is both a control input and a power supply pin. In M58CR064C/D the two functions are selected by the voltage range applied to the pin. In the M58CR064P/Q the control feature is disabled. In M58CR064C/D if VPP is kept in a low voltage range (0V to VDDQ) V PP is seen as a control input. In this case a voltage lower than VPPLK gives an absolute protection against program or erase, while VPP > VPP1 enables these functions (see Tables 18 and 19, DC Characteristics for the relevant values). VPP is only sampled at the beginning of a program or erase; a change in its value after the operation has started does not have any effect and program or erase operations continue. If V PP is in the range of VPPH it acts as a power supply pin. In this condition VPP must be stable until the Program/Erase algorithm is completed. VSS Ground. VSS ground is the reference for the core supply. It must be connected to the system ground. VSSQ Ground. VSSQ ground is the reference for the input/output circuitry driven by V DDQ. VSSQ must be connected to V SS M58CR064C, M58CR064D, M58CR064P, M58CR064Q Note: Each device in a system should have VDD, VDDQ and V PP decoupled with a 0.1µF ceramic capacitor close to the pin (high frequency, inherently low inductance capacitors should be as close as possible to the pack- BUS OPERATIONS There are six standard bus operations that control the device. These are Bus Read, Bus Write, Address Latch, Output Disable, Standby and Reset. See Table 3, Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations. Bus Read. Bus Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register and the Common Flash Interface. Both Chip Enable and Output Enable must be at V IL in order to perform a read operation. The Chip Enable input should be used to enable the device. Output Enable should be used to gate data onto the output. The data read depends on the previous command written to the memory (see Command Interface section). Refer to the Read AC Waveform figures and Characteristics tables in the DC and AC Parameters section for details of when the output becomes valid. Bus Write. Bus Write operations write Commands to the memory or latch Input Data to be programmed. A bus write operation is initiated when Chip Enable and Write Enable are at VIL with Output Enable at VIH. Commands, Input Data and Addresses are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses can also be latched prior to the write operation by toggling Latch Enable. In this case age). See Figure 9, AC Measurement Load Circuit. The PCB track widths should be sufficient to carry the required V PP program and erase currents. the Latch Enable should be tied to VIH during the bus write operation. See Figures 14 and 15, Write AC Waveforms, and Tables 22 and 23, Write AC Characteristics, for details of the timing requirements. Address Latch. Address latch operations input valid addresses. Both Chip enable and Latch Enable must be at V IL during address latch operations. The addresses are latched on the rising edge of Latch Enable. Output Disable. The outputs are high impedance when the Output Enable is at VIH. Standby. Standby disables most of the internal circuitry allowing a substantial reduction of the current consumption. The memory is in stand-by when Chip Enable and Reset/Power-Down are at VIH. The power consumption is reduced to the stand-by level and the outputs are set to high impedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to VIH during a program or erase operation, the device enters Standby mode when finished. Reset. During Reset mode the memory is deselected and the outputs are high impedance. The memory is in Reset mode when Reset/PowerDown is at VIL. The power consumption is reduced to the Standby level, independently from the Chip Enable, Output Enable or Write Enable inputs. If Reset is pulled to VSS during a Program or Erase, this operation is aborted and the memory content is no longer valid. Table 3. Bus Operations Operation E G W L RP Bus Read VIL VIL VIH VIL(2) VIH Bus Write VIL VIH VIL VIL(2) VIH Address Latch VIL X VIH VIL VIH Output Disable VIL VIH VIH X VIH Hi-Z Hi-Z Standby VIH X X X VIH Hi-Z Hi-Z X X X X VIL Hi-Z Hi-Z Reset WAIT DQ15-DQ0 Data Output Hi-Z Data Input Data Output or Hi-Z (3) Note: 1. X = Don’t care. 2. L can be tied to VIH if the valid address has been previously latched. 3. Depends on G. 11/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q COMMAND INTERFACE All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. An internal Program/Erase Controller handles all timings and verifies the correct execution of the Program and Erase commands. The Program/Erase Controller provides a Status Register whose output may be read at any time to monitor the progress or the result of the operation. The Command Interface is reset to read mode when power is first applied, when exiting from Reset or whenever V DD is lower than VLKO . Command sequences must be followed exactly. Any invalid combination of commands will reset the device to read mode. Refer to Table 4, Command Codes and Appendix D, Tables 36 and 37, Command Interface States Modify and Lock Tables, for a summary of the Command Interface. The Command Interface is split into two types of commands: Standard commands and Factory Program commands. The following sections explain in detail how to perform each command. 12/70 Table 4. Command Codes Hex Code Command 01h Block Lock Confirm 03h Set Configuration Register Confirm 10h Alternative Program Setup 20h Block Erase Setup 2Fh Block Lock-Down Confirm 30h Double Word Program Setup 40h Program Setup 50h Clear Status Register 55h Quadruple Word Program Setup 60h Block Lock Setup, Block Unlock Setup, Block Lock Down Setup and Set Configuration Register Setup 70h Read Status Register 80h Bank Erase Setup 90h Read Electronic Signature 98h Read CFI Query B0h Program/Erase Suspend C0h Protection Register Program D0h Program/Erase Resume, Block Erase Confirm, Bank Erase Confirm, Block Unlock Confirm FFh Read Array M58CR064C, M58CR064D, M58CR064P, M58CR064Q COMMAND INTERFACE - STANDARD COMMANDS The following commands are the basic commands Read CFI Query Command used to read, write to and configure the device. The Read CFI Query command is used to read Refer to Table 5, Standard Commands, in condata from the Common Flash Interface (CFI) junction with the following text descriptions. memory area located in the bottom bank. The Read Array Command Read CFI Query Command consists of one Bus Write cycle, to an address within the bottom bank. The Read Array command returns the addressed Once the command is issued subsequent Bus bank to Read Array mode. One Bus Write cycle is Read operations in the same bank read from the required to issue the Read Array command and reCommon Flash Interface. turn the addressed bank to Read Array mode. Subsequent read operations will read the adIf a Read CFI Query command is issued in a bank dressed location and output the data. A Read Arthat is executing a Program or Erase operation the ray command can be issued in one bank while bank will go into Read Status Register mode, subprogramming or erasing in the other bank. Howevsequent Bus Read cycles will output the Status er if a Read Array command is issued to a bank Register and the Program/Erase controller will currently executing a Program or Erase operation continue to Program or Erase in the background. the command will be ignored. When the Program or Erase operation has finished the device will enter Read CFI Query mode. Read Status Register Command This mode supports asynchronous or single synA Bank’s Status Register indicates when a Prochronous reads only, it does not support page gram or Erase operation is complete and the sucmode or synchronous burst reads. cess or failure of operation itself. Issue a Read Status Register command to read the Status RegThe status of the other banks is not affected by the ister content of the addressed Bank. The Read command (see Table 11). After issuing a Read Status Register command can be issued at any CFI Query command, a Read Array command time, even during Program or Erase operations. should be issued to the addressed bank to return the bank to read mode. The following Bus Read operations output the content of the Status Register of the addressed bank. See Appendix B, Common Flash Interface, Tables The Status Register is latched on the falling edge 30, 31, 32, 33, 34 and 35 for details on the inforof E or G signals, and can be read until E or G remation contained in the Common Flash Interface turns to VIH. Either E or G must be toggled to upmemory area. date the latched data. See Table 8 for the Clear Status Register Command description of the Status Register Bits. This mode The Clear Status Register command can be used supports asynchronous or single synchronous to reset (set to ‘0’) error bits SR1, SR3, SR4 and reads only. SR5 in the Status Register of the addressed bank. Read Electronic Signature Command One bus write cycle is required to issue the Clear The Read Electronic Signature command reads Status Register command. After the Clear Status the Manufacturer and Device Codes, the Block Register command the bank returns to Read Array Locking Status, the Protection Register, and the mode. Configuration Register. The error bits in the Status Register do not autoThe Read Electronic Signature command consists matically return to ‘0’ when a new command is isof one write cycle to an address within the bottom sued. The error bits in the Status Register should bank. A subsequent read operation in the address be cleared before attempting a new Program or of the bottom bank will output the Manufacturer Erase command. Code, the Device Code, the protection Status of Block Erase Command Blocks of the bottom bank, the Die Revision Code, The Block Erase command can be used to erase the Protection Register, or the Read Configuration a block. It sets all the bits within the selected block Register (see Table 6). to ’1’. All previous data in the block is lost. If the If the first write cycle of Read Electronic Signature block is protected then the Erase operation will command is issued to an address within the top abort, the data in the block will not be changed and bank, a subsequent read operation in an address the Status Register will output the error. The Block of the top bank will output the protection Status of Erase command can be issued at any moment, reblocks of the top bank. The status of the other gardless of whether the block has been probank is not affected by the command (see Table grammed or not. 11). This mode supports asynchronous or single Two Bus Write cycles are required to issue the synchronous reads only, it does not support page command. mode or synchronous burst reads. ■ The first bus cycle sets up the Erase command. 13/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q The second latches the block address in the internal state machine and starts the Program/ Erase Controller. If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits SR4 and SR5 are set and the command aborts. Erase aborts if Reset turns to VIL. As data integrity cannot be guaranteed when the Erase operation is aborted, the block must be erased again. Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end of the operation the bank will remain in Read Status Register mode until a Read Array, Read CFI Query or Read Electronic Signature command is issued. During Erase operations the bank containing the block being erased will only accept the Read Status Register and the Program/Erase Suspend command, all other commands will be ignored. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 14, Program, Erase Times and Program/Erase Endurance Cycles. See Appendix C, Figure 24, Block Erase Flowchart and Pseudo Code, for a suggested flowchart for using the Block Erase command. Program Command The memory array can be programmed word-byword. Only one Word in one bank can be programmed at any one time. Two bus write cycles are required to issue the Program Command. ■ The first bus cycle sets up the Program command. ■ The second latches the Address and the Data to be written and starts the Program/Erase Controller. After programming has started, read operations in the bank being programmed output the Status Register content. During Program operations the bank being programmed will only accept the Read Status Register and the Program/Erase Suspend command. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 14, Program, Erase Times and Program/Erase Endurance Cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory location must be reprogrammed. See Appendix C, Figure 20, Program Flowchart and Pseudo Code, for the flowchart for using the Program command. ■ 14/70 Program/Erase Suspend Command The Program/Erase Suspend command is used to pause a Program or Block Erase operation. A Bank Erase operation cannot be suspended. One bus write cycle is required to issue the Program/Erase Suspend command. Once the Program/Erase Controller has paused bits SR7, SR6 and/ or SR2 of the Status Register will be set to ‘1’. The command must be addressed to the bank containing the Program or Erase operation. During Program/Erase Suspend the Command Interface will accept the Program/Erase Resume, Read Array (cannot read the suspended block), Read Status Register, Read Electronic Signature and Read CFI Query commands. Additionally, if the suspend operation was Erase then the Clear status Register, Program, Block Lock, Block LockDown or Protection Program commands will also be accepted. The block being erased may be protected by issuing the Block Lock, Block LockDown or Protection Register Program commands. Only the blocks not being erased may be read or programmed correctly. When the Program/Erase Resume command is issued the operation will complete. Refer to the Dual Operations section for detailed information about simultaneous operations allowed during Program/Erase Suspend. During a Program/Erase Suspend, the device can be placed in standby mode by taking Chip Enable to VIH. Program/Erase is aborted if Reset turns to VIL. See Appendix C, Figure 23, Program Suspend & Resume Flowchart and Pseudo Code, and Figure 25, Erase Suspend & Resume Flowchart and Pseudo Code for flowcharts for using the Program/ Erase Suspend command. Program/Erase Resume Command The Program/Erase Resume command can be used to restart the Program/Erase Controller after a Program/Erase Suspend command has paused it. One Bus Write cycle is required to issue the command. The command must be written to the bank containing the Program or Erase Suspend. The Program/Erase Resume command changes the read mode of the target bank to Read Status Register mode. If a Program command is issued during a Block Erase Suspend, then the erase cannot be resumed until the programming operation has completed. It is possible to accumulate suspend operations. For example: suspend an erase operation, start a programming operation, suspend the programming operation then read the array. See Appendix C, Figure 23, Program Suspend & Resume Flowchart and Pseudo Code, and Figure 25, Erase Suspend & Resume Flowchart and Pseudo M58CR064C, M58CR064D, M58CR064P, M58CR064Q Code for flowcharts for using the Program/Erase Resume command. Protection Register Program Command The Protection Register Program command is used to Program the 128 bit user One-Time-Programmable (OTP) segment of the Protection Register. The segment is programmed 16 bits at a time. When shipped all bits in the segment are set to ‘1’. The user can only program the bits to ‘0’. Two write cycles are required to issue the Protection Register Program command. ■ The first bus cycle sets up the Protection Register Program command. ■ The second latches the Address and the Data to be written to the Protection Register and starts the Program/Erase Controller. Read operations output the Status Register content after the programming has started. The segment can be protected by programming bit 1 of the Protection Lock Register. Bit 1 of the Protection Lock Register also protects bit 2 of the Protection Lock Register. Programming bit 2 of the Protection Lock Register will result in a permanent protection of Parameter Block #0 (see Figure 5, Security Block and Protection Register Memory Map). Attempting to program a previously protected Protection Register will result in a Status Register error. The protection of the Protection Register and/or the Security Block is not reversible. The Protection Register Program cannot be suspended. See Appendix C, Figure 27, Protection Register Program Flowchart and Pseudo Code, for a flowchart for using the Protection Register Program command. Set Configuration Register Command. The Set Configuration Register command is used to write a new value to the Configuration Control Register which defines the burst length, type, X latency, Synchronous/Asynchronous Read mode and the valid Clock edge configuration. Two Bus Write cycles are required to issue the Set Configuration Register command. ■ The first cycle writes the setup command and the address corresponding to the Configuration Register content. ■ The second cycle writes the Configuration Register data and the confirm command. Once the command is issued the memory returns to Read mode. The value for the Configuration Register is always presented on A0-A15. CR0 is on A0, CR1 on A1, etc.; the other address bits are ignored. Block Lock Command The Block Lock command is used to lock a block and prevent Program or Erase operations from changing the data in it. All blocks are locked at power-up or reset. Two Bus Write cycles are required to issue the Block Lock command. ■ The first bus cycle sets up the Block Lock command. ■ The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table. 13 shows the Lock Status after issuing a Block Lock command. The Block Lock bits are volatile, once set they remain set until a hardware reset or power-down/ power-up. They are cleared by a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation. See Appendix C, Figure 26, Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Lock command. Block Unlock Command The Block Unlock command is used to unlock a block, allowing the block to be programmed or erased. Two Bus Write cycles are required to issue the Block Unlock command. ■ The first bus cycle sets up the Block Unlock command. ■ The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table 13 shows the protection status after issuing a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26, Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Unlock command. Block Lock-Down Command A locked or unlocked block can be locked-down by issuing the Block Lock-Down command. A lockeddown block cannot be programmed or erased, or have its protection status changed when WP is low, VIL. When WP is high, VIH, the Lock-Down function is disabled and the locked blocks can be individually unlocked by the Block Unlock command. Two Bus Write cycles are required to issue the Block Lock-Down command. ■ The first bus cycle sets up the Block Lock command. ■ The second Bus Write cycle latches the block address. 15/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q The lock status can be monitored for each block using the Read Electronic Signature command. Locked-Down blocks revert to the locked (and not locked-down) state when the device is reset on power-down. Table. 13 shows the Lock Status af- ter issuing a Block Lock-Down command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26, Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Lock-Down command. Commands Cycles Table 5. Standard Commands Bus Operations 1st Cycle 2nd Cycle Op. Add Data Op. Add Data Read Array 1+ Write BKA FFh Read WA RD Read Status Register 1+ Write BKA 70h Read BKA(2) SRD Read Electronic Signature 1+ Write BBKA or BKA(3) 90h Read BBKA or BKA(2,3) ESD(3) Read CFI Query 1+ Write BBKA 98h Read BBKA (2) QD Clear Status Register 1 Write BKA 50h Block Erase 2 Write BKA 20h Write BA D0h Program 2 Write BKA 40h or 10h Write WA PD Program/Erase Suspend 1 Write BKA B0h Program/Erase Resume 1 Write BKA D0h Protection Register Program 2 Write PRA C0h Write PRA PRD Set Configuration Register 2 Write CRD 60h Write CRD 03h Block Lock 2 Write BKA 60h Write BA 01h Block Unlock 2 Write BKA 60h Write BA D0h Block Lock-Down 2 Write BKA 60h Write BA 2Fh Note: 1. X = Don’t Care, WA=Word Address in targeted bank, RD=Read Data, SRD=Status Register Data, ESD=Electronic Signature Data, QD=Query Data, BA=Block Address, BKA= Bank Address, BBKA= Bottom Bank Address, PD=Program Data, PRA=Protection Register Address, PRD=Protection Register Data, CRD=Configuration Register Data. 2. Must be same bank as in the first cycle. The signature addresses are listed in Table 6. 3. When addressed to a block in the Top Bank, reads Block Protection data only. 16/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 6. Electronic Signature Codes Code Manufacturer Code Address (h) Data (h) Bottom Bank Address + 00 0020 Top (M58CR064C) 88CA Bottom (M58CR064D) 88CB Device Code Bottom Bank Address + 01 Top (M58CR064P) 8801 Bottom (M58CR064Q) 8802 Lock 0001 Unlocked 0000 Block Protection Block Address + 02 Locked and Locked-Down 0003 Unlocked and Locked-Down 0002 Reserved Bottom Bank Address + 03 Reserved Configuration Register Bottom Bank Address + 05 CR Protection Register Lock ST Factory Default xx06 Security Block Permanently Locked xx02 Bottom Bank Address + 80 OTP Area Permanently Locked Security Block and OTP Area Permanently Locked xx04 xx00 Bottom Bank Address + 81 Bottom Bank Address + 84 Unique Device Number Bottom Bank Address + 85 Bottom Bank Address + 8C OTP Area Protection Register Note: CR=Configuration Register. Figure 5. Security Block and Protection Register Memory Map PROTECTION REGISTER 8Ch SECURITY BLOCK User Programmable OTP 85h 84h Parameter Block # 0 Unique device number 81h 80h Protection Register Lock 2 1 0 AI06181 17/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q COMMAND INTERFACE - FACTORY PROGRAM COMMANDS The Factory Program commands are used to Double Word Program Command speed up programming. They require V PP to be at The Double Word Program command improves VPPH except for the Bank Erase command which the programming throughput by writing a page of also operates at VPP = VDD. Refer to Table 7, Factwo adjacent words in parallel. The two words tory Program Commands, in conjunction with the must differ only for the address A0. following text descriptions. Programming should not be attempted when VPP Bank Erase Command is not at VPPH. The command can be executed if VPP is below VPPH but the result is not guaranteed. The Bank Erase command can be used to erase a bank. It sets all the bits within the selected bank to Three bus write cycles are necessary to issue the ’1’. All previous data in the bank is lost. The Bank Double Word Program command. Erase command will ignore any protected blocks ■ The first bus cycle sets up the Double Word within the bank. If all blocks in the bank are proProgram Command. tected then the Bank Erase operation will abort ■ The second bus cycle latches the Address and and the data in the bank will not be changed. The the Data of the first word to be written. Status Register will not output any error. ■ The third bus cycle latches the Address and the Bank Erase operations can be performed at both Data of the second word to be written and starts VPP = VPPH and V PP = VDD. the Program/Erase Controller. Two Bus Write cycles are required to issue the Read operations in the bank being programmed command. output the Status Register content after the pro■ The first bus cycle sets up the Bank Erase gramming has started. command. During Double Word Program operations the bank ■ The second latches the bank address in the being programmed will only accept the Read Stainternal state machine and starts the Program/ tus Register command, all other commands will be Erase Controller. ignored. Dual operations are not supported during If the second bus cycle is not Write Bank Erase Double Word Program operations. It is not recomConfirm (D0h), Status Register bits SR4 and SR5 mended to suspend the Double Word Program are set and the command aborts. Erase aborts if command. Typical Program times are given in TaReset turns to VIL. As data integrity cannot be ble 14, Program, Erase Times and Program/Erase guaranteed when the Erase operation is aborted, Endurance Cycles. the bank must be erased again. Programming aborts if Reset goes to VIL. As data Once the command is issued the device outputs integrity cannot be guaranteed when the program the Status Register data when any address within operation is aborted, the memory locations must the bank is read. At the end of the operation the be reprogrammed. bank will remain in Read Status Register mode unSee Appendix C, Figure 21, Double Word Protil a Read Array, Read CFI Query or Read Elecgram Flowchart and Pseudo Code, for the flowtronic Signature command is issued. chart for using the Double Word Program During Bank Erase operations the bank being command. erased will only accept the Read Status Register Quadruple Word Program Command command, all other commands will be ignored. A The Quadruple Word Program command imBank Erase operation cannot be suspended. proves the programming throughput by writing a For optimum performance, Bank Erase compage of four adjacent words in parallel. The four mands should be limited to a maximum of 100 Prowords must differ only for the addresses A0 and gram/Erase cycles per Block. After 100 Program/ A1. Erase cycles the internal algorithm will still operate Programming should not be attempted when VPP properly but some degradation in performance is not at VPPH. The command can be executed if may occur. VPP is below VPPH but the result is not guaranteed. Dual operations are not supported during Bank Five bus write cycles are necessary to issue the Erase operations and the command cannot be Quadruple Word Program command. suspended. ■ The first bus cycle sets up the Double Word Typical Erase times are given in Table 14, ProProgram Command. gram, Erase Times and Program/Erase Endurance Cycles. ■ The second bus cycle latches the Address and the Data of the first word to be written. 18/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q The third bus cycle latches the Address and the Data of the second word to be written. ■ The fourth bus cycle latches the Address and the Data of the third word to be written. ■ The fifth bus cycle latches the Address and the Data of the fourth word to be written and starts the Program/Erase Controller. Read operations to the bank being programmed output the Status Register content after the programming has started. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory locations must be reprogrammed. ■ During Quadruple Word Program operations the bank being programmed will only accept the Read Status Register command, all other commands will be ignored. Dual operations are not supported during Quadruple Word Program operations. It is not recommended to suspend the Quadruple Word Program command. Typical Program times are given in Table 14, Program, Erase Times and Program/Erase Endurance Cycles. See Appendix C, Figure 22, Quadruple Word Program Flowchart and Pseudo Code, for the flowchart for using the Quadruple Word Program command. Command Phase Cycles Table 7. Factory Program Commands Bus Write Operations 1st 2nd 3rd Add Data Add Data 4th Add Data Bank Erase 2 BKA 80h BKA D0h Double Word Program(2) 3 BKA 30h WA1 PD1 WA2 PD2 Quadruple Word Program(3) 5 BKA 55h WA1 PD1 WA2 PD2 5th Add Data Add Data WA3 PD3 WA4 PD4 Note: 1. WA=Word Address in targeted bank, BKA= Bank Address, PD=Program Data, WA1 is the Start Address. 2. Word Addresses 1 and 2 must be consecutive Addresses differing only for A0. 3. Word Addresses 1,2,3 and 4 must be consecutive Addresses differing only for A0 and A1. 19/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q STATUS REGISTER The M58CR064 has two Status Registers, one for each bank. The Status Registers provide information on the current or previous Program or Erase operations executed in each bank. Issue a Read Status Register command to read the contents of the Status Register, refer to Read Status Register Command section for more details. To output the contents, the Status Register is latched and updated on the falling edge of the Chip Enable or Output Enable signals, and can be read until Chip Enable or Output Enable returns to VIH. The Status Register can only be read using single asynchronous or single synchronous reads. Bus Read operations from any address within the bank, always read the Status Register during Program and Erase operations. The various bits convey information about the status and any errors of the operation. Bits SR7, SR6 and SR2 give information on the status of the bank and are set and reset by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the device but must be reset by issuing a Clear Status Register command or a hardware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command. The bits in the Status Register are summarized in Table 8, Status Register Bits. Refer to Table 8 in conjunction with the following text descriptions. Program/Erase Controller Status Bit (SR7). The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is active or inactive in the addressed bank. When the Program/Erase Controller Status bit is Low (set to ‘0’), the Program/Erase Controller is active; when the bit is High (set to ‘1’), the Program/Erase Controller is inactive, and the device is ready to process a new command. The Program/Erase Controller Status is Low immediately after a Program/Erase Suspend command is issued until the Program/Erase Controller pauses. After the Program/Erase Controller pauses the bit is High. During Program, Erase, operations the Program/ Erase Controller Status bit can be polled to find the end of the operation. Other bits in the Status Register should not be tested until the Program/Erase Controller completes the operation and the bit is High. After the Program/Erase Controller completes its operation the Erase Status, Program Status, VPP Status and Block Lock Status bits should be tested for errors. Erase Suspend Status Bit (SR6). The Erase Suspend Status bit indicates that an Erase operation has been suspended or is going to be sus- 20/70 pended in the addressed block. When the Erase Suspend Status bit is High (set to ‘1’), a Program/ Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Erase Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR7 is set within 30µs of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Erase Suspend Status bit returns Low. Erase Status Bit (SR5). The Erase Status bit can be used to identify if the memory has failed to verify that the block or bank has erased correctly. When the Erase Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the block or bank and still failed to verify that it has erased correctly. The Erase Status bit should be read once the Program/ Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Erase Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. Program Status Bit (SR4). The Program Status bit is used to identify a Program failure. When the Program Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the byte and still failed to verify that it has programmed correctly. The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Program Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. VPP Status Bit (SR3). The V PP Status bit can be used to identify an invalid voltage on the VPP pin during Program and Erase operations. The VPP pin is only sampled at the beginning of a Program or Erase operation. Indeterminate results can occur if V PP becomes invalid during an operation. When the VPP Status bit is Low (set to ‘0’), the voltage on the V PP pin was sampled at a valid voltage; when the V PP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the V PP Lockout Voltage, VPPLK, the memory is protected and Program and Erase operations cannot be performed. M58CR064C, M58CR064D, M58CR064P, M58CR064Q Once set High, the V PP Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. Program Suspend Status Bit (SR2). The Program Suspend Status bit indicates that a Program operation has been suspended in the addressed block. When the Program Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Program Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR2 is set within 5µs of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Program Suspend Status bit returns Low. Block Protection Status Bit (SR1). The Block Protection Status bit can be used to identify if a Program or Block Erase operation has tried to modify the contents of a locked block. When the Block Protection Status bit is High (set to ‘1’), a Program or Erase operation has been attempted on a locked block. Once set High, the Block Protection Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. Reserved Bit (SR0). SR0 is reserved. Its value must be masked. Table 8. Status Register Bits Bit SR7 SR6 SR5 SR4 SR3 SR2 SR1 Name P/E.C. Status Erase Suspend Status Erase Status Program Status VPP Status Type Logic Level Definition ’1’ Ready ’0’ Busy ’1’ Erase Suspended ’0’ Erase In progress or Completed ’1’ Erase Error ’0’ Erase Success ’1’ Program Error ’0’ Program Success ’1’ VPP Invalid, Abort ’0’ VPP OK ’1’ Program Suspended ’0’ Program In Progress or Completed ’1’ Program/Erase on protected Block, Abort ’0’ No operation to protected blocks Status Status Error Error Error Program Suspend Status Status Block Protection Status SR0 Error Reserved Note: Logic level ’1’ is High, ’0’ is Low. 21/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q CONFIGURATION REGISTER The Configuration Register is used to configure the type of bus access that the memory will perform. Refer to Read Modes section for details on read operations. The Configuration Register is set through the Command Interface. After a Reset or Power-Up the device is configured for asynchronous page read (CR15 = 1). The Configuration Register bits are described in Table 9. They specify the selection of the burst length, burst type, burst X latency and the Read operation. Refer to Figures 6 and 7 for examples of synchronous burst configurations. Read Select Bit (CR15) The Read Select bit, CR15, is used to switch between asynchronous and synchronous Bus Read operations. When the Read Select bit is set to ’1’, read operations are asynchronous; when the Read Select bit is set to ’0’, read operations are synchronous. Synchronous Burst Read is supported in both parameter and main blocks and can be performed across banks. On reset or power-up the Read Select bit is set to’1’ for asynchronous access. X-Latency Bits (CR13-CR11) The X-Latency bits are used during Synchronous Read operations to set the number of clock cycles between the address being latched and the first data becoming available. For correct operation the X-Latency bits can only assume the values in Table 9, Configuration Register. The correspondence between X-Latency settings and the maximum sustainable frequency must be calculated taking into account some system parameters. Two conditions must be satisfied: 1. Depending on whether tAVK_CPU or t DELAY is supplied either one of the following two equations must be satisfied: (n + 1) t K ≥ tACC - tAVK_CPU + tQVK_CPU (n + 2) tK ≥ tACC + tDELAY + tQVK_CPU 2. and also tK > tKQV + tQVK_CPU where n is the chosen X-Latency configuration code tK is the clock period tAVK_CPU is clock to address valid, L Low, or E Low, whichever occurs last tDELAY is address valid, L Low, or E Low to clock, whichever occurs last tQVK_CPU is the data setup time required by the system CPU, tKQV is the clock to data valid time tACC is the random access time of the device. 22/70 Refer to Figure 6, X-Latency and Data Output Configuration Example. Power-Down Bit (CR10) The Power-Down bit is used to enable or disable the power-down function. When the Power-Down bit is set to ‘0’ the powerdown function is disabled. If the Reset/PowerDown, RP, pin goes Low, VIL, the device is reset and the supply current, IDD, is reduced to the standby value, IDD3. When the Power-Down bit is set to ‘1’ the powerdown function is enabled. If the Reset/PowerDown, RP, pin goes Low, VIL, the device goes into the power-down state and the supply current, IDD, is reduced to the power-down value, IDD2. The recovery time after a Reset/Power-Down, RP, pulse is significantly longer when power-down is enabled (see Table 24). After a reset the Power-Down Bit is set to ‘0’. Wait Configuration Bit (CR8) In burst mode the Wait bit controls the timing of the Wait output pin, WAIT. When the Wait bit is ’0’ the Wait output pin is asserted during the wait state. When the Wait bit is ’1’ (default) the Wait output pin is asserted one clock cycle before the wait state. WAIT is asserted during a continuous burst and also during a 4 or 8 burst length if no-wrap configuration is selected. WAIT is not asserted during asynchronous reads, single synchronous reads or during latency in synchronous reads. Burst Type Bit (CR7) The Burst Type bit is used to configure the sequence of addresses read as sequential or interleaved. When the Burst Type bit is ’0’ the memory outputs from interleaved addresses; when the Burst Type bit is ’1’ (default) the memory outputs from sequential addresses. See Tables 10, Burst Type Definition, for the sequence of addresses output from a given starting address in each mode. Valid Clock Edge Bit (CR6) The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during Synchronous Burst Read operations. When the Valid Clock Edge bit is ’0’ the falling edge of the Clock is the active edge; when the Valid Clock Edge bit is ’1’ the rising edge of the Clock is active. Wrap Burst Bit (CR3) The burst reads can be confined inside the 4 or 8 Word boundary (wrap) or overcome the boundary (no wrap). The Wrap Burst bit is used to select between wrap and no wrap. When the Wrap Burst bit is set to ‘0’ the burst read wraps; when it is set to ‘1’ the burst read does not wrap. M58CR064C, M58CR064D, M58CR064P, M58CR064Q Burst length Bits (CR2-CR0) The Burst Length bits set the number of Words to be output during a Synchronous Burst Read operation as result of a single address latch cycle. They can be set for 4 words, 8 words or continuous burst, where all the words are read sequentially. In continuous burst mode the burst sequence can cross bank boundaries. In continuous burst mode or in 4, 8 words no-wrap, depending on the starting address, the device asserts the WAIT output to indicate that a delay is necessary before the data is output. If the starting address is aligned to a 4 word boundary no wait states are needed and the WAIT output is not asserted. If the starting address is shifted by 1,2 or 3 positions from the four word boundary, WAIT will be asserted for 1, 2 or 3 clock cycles when the burst sequence crosses the first 64 word boundary, to indicate that the device needs an internal delay to read the successive words in the array. WAIT will be asserted only once during a continuous burst access. See also Table 10, Burst Type Definition. CR14, CR9, CR5 and CR4 are reserved for future use. Table 9. Configuration Register Bit CR15 Description Value 0 Synchronous Read 1 Asynchronous Read (Default at power-on) Read Select CR14 CR13-CR11 Description Reserved 010 2 clock latency 011 3 clock latency 100 4 clock latency 101 5 clock latency 111 Reserved X-Latency Other configurations reserved CR10 Power-Down 0 Power-Down disabled 1 Power-Down enabled CR9 CR8 CR7 CR6 Reserved 0 WAIT is active during wait state 1 WAIT is active one data cycle before wait state (default) 0 Interleaved 1 Sequential (default) 0 Falling Clock edge 1 Rising Clock edge Wait Configuration Burst Type Valid Clock Edge CR5-CR4 CR3 CR2-CR0 Reserved 0 Wrap 1 No Wrap 001 4 words 010 8 words 111 Continuous (CR7 must be set to ‘1’) Wrap Burst Burst Length 23/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Mode Table 10. Burst Type Definition Start Address 4 Words 8 Words Continuous Burst Sequential Interleaved Sequential Interleaved 0 0-1-2-3 0-1-2-3 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6... 1 1-2-3-0 1-0-3-2 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 1-2-3-4-5-6-7... 2 2-3-0-1 2-3-0-1 2-3-4-5-6-7-0-1 2-3-0-1-6-7-4-5 2-3-4-5-6-7-8... 3 3-0-1-2 3-2-1-0 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 3-4-5-6-7-8-9... 7-4-5-6 7-6-5-4 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 7-8-9-10-11-12-13... Wrap ... 7 ... 60 60-61-62-63-64-65-66... 61 61-62-63-WAIT-64-65-66... 62 62-63-WAIT-WAIT-64-65-66... 63 63-WAIT-WAIT-WAIT-64-6566... Sequential Interleaved Sequential 0 0-1-2-3 0-1-2-3-4-5-6-7 1 1-2-3-4 1-2-3-4-5-6-7-8 2 2-3-4-5 2-3-4-5-6-7-8-9... 3 3-4-5-6 3-4-5-6-7-8-9-10 7-8-9-10 7-8-9-10-11-12-13-14 60 60-61-62-63 60-61-62-63-64-65-6667 61 61-62-63-WAIT-64 61-62-63-WAIT-64-6566-67-68 62 62-63-WAIT-WAIT64-65 62-63-WAIT-WAIT-6465-66-67-68-69 63 63-WAIT-WAITWAIT-64-65-66 63-WAIT-WAIT-WAIT64-65-66-67-68-69-70 Interleaved No-wrap ... 24/70 7 ... Same as for Wrap (Wrap /No Wrap has no effect on Continuous Burst ) M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 6. X-Latency and Data Output Configuration Example X-latency 1st cycle 2nd cycle 3rd cycle 4th cycle K E L A21-A0 tDELAY VALID ADDRESS tAVK_CPU tQVK_CPU tK tKQV tACC tQVK_CPU DQ15-DQ0 VALID DATA VALID DATA Note. Settings shown: X-latency = 4, Data Output held for one clock cycle AI90005 Figure 7. Wait Configuration Example E K L A21-A0 DQ15-DQ0 VALID ADDRESS VALID DATA VALID DATA NOT VALID VALID DATA WAIT CR8 = '0' WAIT CR8 = '1' AI90006b 25/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q READ MODES Read operations can be performed in two different ways depending on the settings in the Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read operation is Asynchronous; if the data output is synchronized with clock, the read operation is Synchronous. The Read mode and data output format are determined by the Configuration Register. (See Configuration Register section for details). All banks supports both asynchronous and synchronous read operations. The Dual Bank architecture allows read operations in one bank, while write operations are being executed in the other (see Tables 11 and 12). Asynchronous Read Mode In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the data corresponding to the address latched, that is the memory array, Status Register, Common Flash Interface or Electronic Signature depending on the command issued. CR15 in the Configuration Register must be set to ‘1’ for Asynchronous operations. In Asynchronous Read mode a Page of data is internally read and stored in a Page Buffer. The Page has a size of 4 Words and is addressed by A0 and A1 address inputs. The address inputs A0 and A1 are not gated by Latch Enable in Asynchronous Read mode. The first read operation within the Page has a longer access time (Tacc, Random access time), subsequent reads within the same Page have much shorter access times. If the Page changes then the normal, longer timings apply again. Asynchronous Read operations can be performed in two different ways, Asynchronous Random Access Read and Asynchronous Page Read. Only Asynchronous Page Read takes full advantage of the internal page storage so different timings are applied. See Table 20, Asynchronous Read AC Characteristics, Figure 10, Asynchronous Random Access Read AC Waveform and Figure 11, Asynchronous Page Read AC Waveform for details. Synchronous Burst Read Mode In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It is possible to perform burst reads across bank boundaries. Synchronous Burst Read mode can only be used to read the memory array. For other read operations, such as Read Status Register, Read CFI and Read Electronic Signature, Single Synchronous Read or Asynchronous Random Access Read must be used. 26/70 In Synchronous Burst Read mode the flow of the data output depends on parameters that are configured in the Configuration Register. A burst sequence is started at the first clock edge (rising or falling depending on Valid Clock Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable or Chip Enable, whichever occurs last. Addresses are internally incremented and after a delay of 2 to 5 clock cycles (X latency bits CR13-CR11) the corresponding data are output on each clock cycle. The number of Words to be output during a Synchronous Burst Read operation can be configured as 4 or 8 Words or Continuous (Burst Length bits CR2-CR0). The data can be configured to remain valid for one or two clock cycles (Data Output Configuration bit CR9). The order of the data output can be modified through the Burst Type and the Wrap Burst bits in the Configuration Register. The burst sequence may be configured to be sequential or interleaved (CR7). The burst reads can be confined inside the 4 or 8 Word boundary (Wrap) or overcome the boundary (No Wrap). If the starting address is aligned to the Burst Length (4 or 8 Words), the wrapped configuration has no impact on the output sequence. Interleaved mode is not allowed in Continuous Burst Read mode or with No Wrap sequences. A WAIT signal may be asserted to indicate to the system that an output delay will occur. This delay will depend on the starting address of the burst sequence; the worst case delay will occur when the sequence is crossing a 64 word boundary and the starting address was at the end of a four word boundary. WAIT is asserted during the Wait state and at the end of 4- and 8-Word Burst. It is deasserted during the X latency and when output data are valid. In Continuous Burst Read mode a Wait state will occur when crossing the first 64 Word boundary. If the burst starting address is aligned to a 4 Word Page, the Wait state will not occur. The WAIT signal is active Low. The WAIT signal is meaningful only in Synchronous Burst Read mode, in other modes, WAIT is not asserted (except for Read Array mode). See Table 21, Synchronous Read AC Characteristics and Figure 12, Synchronous Burst Read AC Waveform for details. Single Synchronous Read Mode Single Synchronous Read operations are similar to Synchronous Burst Read operations except that only the first data output after the X latency is valid. Other Configuration Register parameters have no effect on Single Synchronous Read operations. M58CR064C, M58CR064D, M58CR064P, M58CR064Q Synchronous Single Reads are used to read the Electronic Signature, Status Register, CFI, Block Protection Status, Configuration Register Status or Protection Register. When the addressed bank is in Read CFI, Read Status Register or Read Electronic Signature mode, the WAIT signal is always deasserted. See Table 21, Synchronous Read AC Characteristics and Figure 13, Single Synchronous Read AC Waveform for details. DUAL OPERATIONS AND MULTIPLE BANK ARCHITECTURE The Dual Operations feature simplifies the softthen a Program command can be issued to anothware management of the device and allows code er block, so the device can have one block in to be executed from one bank while the other bank Erase Suspend mode, one programming and the is being programmed or erased. other bank in Read mode. Bus Read operations are allowed in the other bank between setup and The Dual operations feature means that while proconfirm cycles of program or erase operations. gramming or erasing in one bank, Read operaThe combination of these features means that tions are possible in the other bank with zero read operations are possible at any moment. latency (only one bank at a time is allowed to be in Program or Erase mode). If a Read operation is reTables 11 and 12 show the dual operations possiquired in a bank which is programming or erasing, ble in the other bank and in the same bank. For a the Program or Erase operation can be suspendcomplete list of possible commands refer to Aped. Also if the suspended operation was Erase pendix D, Command Interface State Tables. Table 11. Dual Operations Allowed In Other Bank Commands allowed in other bank Read Array Read Status Register Read CFI Query Idle Yes Yes Yes Yes Yes Yes Yes Yes Programming Yes Yes Yes Yes – – – – Erasing Yes Yes Yes Yes – – – – Program Suspended Yes Yes Yes Yes – – – Yes Erase Suspended Yes Yes Yes Yes Yes – – Yes Block Erase Program/ Erase Suspend Program/ Erase Resume Status of bank Read Electronic Program Signature Block Erase Program/ Program/ Erase Erase Suspend Resume Table 12. Dual Operations Allowed In Same Bank Commands allowed in same bank Status of bank Idle Read Array Read Read Read Status Electronic Program CFI Query Register Signature Yes Yes Yes Yes Yes Yes Yes Yes Programming – Yes – – – – Yes – Erasing – Yes – – – – Yes – Program Suspended Yes(1) Yes Yes Yes – – – Yes Erase Suspended Yes(1) Yes Yes Yes Yes(1) – – Yes Note: 1. Not allowed in the Block or Word that is being erased or programmed. 27/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q BLOCK LOCKING The M58CR064 features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency. This locking scheme has three levels of protection. ■ Lock/Unlock - this first level allows softwareonly control of block locking. ■ ■ Lock-Down - this second level requires hardware interaction before locking can be changed. VPP ≤ VPPLK - the third level offers a complete hardware protection against program and erase on all blocks (M58CR064C/D only). The first two levels (Lock/Unlock and Lock-Down) are available in M58CR064C/D and M58CR064P/ Q. The third level (VPP ≤ VPPLK) is only available for the M58CR064C/D versions, in the M58CR064P/Q this feature has been disabled. For all devices the protection status of each block can be set to Locked, Unlocked, and Lock-Down. Table 13, defines all of the possible protection states (WP, DQ1, DQ0), and Appendix C, Figure 26, shows a flowchart for the locking operations. Reading a Block’s Lock Status The lock status of every block can be read in the Read Electronic Signature mode of the device. To enter this mode write 90h to the device. Subsequent reads at the address specified in Table 6, will output the protection status of that block. The lock status is represented by DQ0 and DQ1. DQ0 indicates the Block Lock/Unlock status and is set by the Lock command and cleared by the Unlock command. It is also automatically set when entering Lock-Down. DQ1 indicates the Lock-Down status and is set by the Lock-Down command. It cannot be cleared by software, only by a hardware reset or power-down. The following sections explain the operation of the locking system. Locked State The default status of all blocks on power-up or after a hardware reset is Locked (states (0,0,1) or (1,0,1)). Locked blocks are fully protected from any program or erase. Any program or erase operations attempted on a locked block will return an error in the Status Register. The Status of a Locked block can be changed to Unlocked or Lock-Down using the appropriate software commands. An Unlocked block can be Locked by issuing the Lock command. Unlocked State Unlocked blocks (states (0,0,0), (1,0,0) (1,1,0)), can be programmed or erased. All unlocked blocks return to the Locked state after a hardware 28/70 reset or when the device is powered-down. The status of an unlocked block can be changed to Locked or Locked-Down using the appropriate software commands. A locked block can be unlocked by issuing the Unlock command. Lock-Down State Blocks that are Locked-Down (state (0,1,x))are protected from program and erase operations (as for Locked blocks) but their protection status cannot be changed using software commands alone. A Locked or Unlocked block can be Locked-Down by issuing the Lock-Down command. LockedDown blocks revert to the Locked state when the device is reset or powered-down. The Lock-Down function is dependent on the WP input pin. When WP=0 (VIL), the blocks in the Lock-Down state (0,1,x) are protected from program, erase and protection status changes. When WP=1 (V IH) the Lock-Down function is disabled (1,1,x) and Locked-Down blocks can be individually unlocked to the (1,1,0) state by issuing the software command, where they can be erased and programmed. These blocks can then be re-locked (1,1,1) and unlocked (1,1,0) as desired while WP remains high. When WP is low , blocks that were previously Locked-Down return to the Lock-Down state (0,1,x) regardless of any changes made while WP was high. Device reset or power-down resets all blocks , including those in Lock-Down, to the Locked state. Locking Operations During Erase Suspend Changes to block lock status can be performed during an erase suspend by using the standard locking command sequences to unlock, lock or lock-down a block. This is useful in the case when another block needs to be updated while an erase operation is in progress. To change block locking during an erase operation, first write the Erase Suspend command, then check the status register until it indicates that the erase operation has been suspended. Next write the desired Lock command sequence to a block and the lock status will be changed. After completing any desired lock, read, or program operations, resume the erase operation with the Erase Resume command. If a block is locked or locked-down during an erase suspend of the same block, the locking status bits will be changed immediately, but when the erase is resumed, the erase operation will complete. Locking operations cannot be performed during a program suspend. Refer to Appendix D, Command Interface State Table, for detailed information on which commands are valid during erase suspend. M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 13. Lock Status Current Protection Status(1) (WP, DQ1, DQ0) Next Protection Status(1) (WP, DQ1, DQ0) Current State Program/Erase Allowed After Block Lock Command After Block Unlock Command After Block Lock-Down Command After WP transition 1,0,0 yes 1,0,1 1,0,0 1,1,1 0,0,0 1,0,1(2) no 1,0,1 1,0,0 1,1,1 0,0,1 1,1,0 yes 1,1,1 1,1,0 1,1,1 0,1,1 1,1,1 no 1,1,1 1,1,0 1,1,1 0,1,1 0,0,0 yes 0,0,1 0,0,0 0,1,1 1,0,0 0,0,1(2) no 0,0,1 0,0,0 0,1,1 1,0,1 0,1,1 no 0,1,1 0,1,1 0,1,1 1,1,1 or 1,1,0 (3) Note: 1. The lock status is defined by the write protect pin and by DQ1 (‘1’ for a locked-down block) and DQ0 (‘1’ for a locked block) as read in the Read Electronic Signature command with A1 = VIH and A0 = VIL. 2. All blocks are locked at power-up, so the default configuration is 001 or 101 according to WP status. 3. A WP transition to VIH on a locked block will restore the previous DQ0 value, giving a 111 or 110. 29/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q PROGRAM AND ERASE TIMES AND ENDURANCE CYCLES The Program and Erase times and the number of Program/ Erase cycles depends on the voltage Program/ Erase cycles per block are shown in Tasupply used. ble 14. In the M58CR064 the maximum number of Table 14. Program, Erase Times and Program, Erase Endurance Cycles Typ Typical after 100k W/E Cycles Max Unit 0.3 1 2.5 s Preprogrammed 0.8 3 4 s Not Preprogrammed 1.1 4 s Preprogrammed 11 s Not Preprogrammed 18 s Preprogrammed 33 s Not Preprogrammed 54 s Parameter Block (4 KWord) Program(3) 40 ms Main Block (32 KWord) Program(3) 300 ms Word Program (3) 10 Program Suspend Latency Erase Suspend Latency Parameter Condition Min Parameter Block (4 KWord) Erase(2) Main Block (32 KWord) Erase VPP = VDD Bank A (16Mbit) Erase Bank B (48Mbit) Erase 10 100 µs 5 10 µs 5 20 µs Main Blocks 100,000 cycles Parameter Blocks 100,000 cycles Program/Erase Cycles (per Block) Parameter Block (4 KWord) Erase 0.3 2.5 s Main Block (32 KWord) Erase 0.9 4 s Bank A (16Mbit) Erase 13 s Bank B (48Mbit) Erase 39 s 510 ms VPP = VPPH 4Mbit Program Quadruple Word Word/ Double Word/ Quadruple Word Program(3) Parameter Block (4 KWord) Program(3) Main Block (32 KWord) Program(3) 8 100 µs Quadruple Word 8 ms Word 32 ms Quadruple Word 64 ms Word 256 ms Main Blocks 1000 cycles Parameter Blocks 2500 cycles Program/Erase Cycles (per Block) Note: 1. TA = –40 to 85°C; VDD = 1.65V to 2V; VDDQ = 1.65V to 3.3V. 2. The difference between Preprogrammed and not preprogrammed is not significant (‹30ms). 3. Excludes the time needed to execute the command sequence. 30/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q MAXIMUM RATING Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not im- plied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 15. Absolute Maximum Ratings Value Symbol Min Max Unit Ambient Operating Temperature –40 85 °C TBIAS Temperature Under Bias –40 125 °C TSTG Storage Temperature –55 155 °C VIO Input or Output Voltage –0.5 VDDQ+0.5 V VDD Supply Voltage –0.5 2.7 V Input/Output Supply Voltage –0.5 3.6 V Program Voltage –0.5 13 V Output Short Circuit Current 100 mA Time for VPP at VPPH 100 hours TA VDDQ VPP IO tVPPH Parameter 31/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q DC AND AC PARAMETERS This section summarizes the operating measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 16, Operating and AC Measurement Conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 16. Operating and AC Measurement Conditions M58CR064C, M58CR064D, M58CR064P, M58CR064Q 85 90 100 120 Parameter Unit Min Max Min Max Min Max Min Max VDD Supply Voltage 1.8 2.0 1.7 2.0 1.65 2.0 1.65 2.0 V VDDQ Supply Voltage 1.8 3.3 1.7 3.3 1.65 3.3 1.65 3.3 V VPP Supply Voltage (Factory environment) 11.4 12.6 11.4 12.6 11.4 12.6 11.4 12.6 V VPP Supply Voltage (Application environment) –0.4 VDDQ +0.4 –0.4 VDDQ +0.4 –0.4 VDDQ +0.4 –0.4 VDDQ +0.4 V Ambient Operating Temperature –40 85 –40 85 –40 85 –40 85 °C Load Capacitance (CL) 30 30 Input Rise and Fall Times Input Pulse Voltages Input and Output Timing Ref. Voltages 30 30 pF 4 4 4 4 ns 0 to VDDQ 0 to VDDQ 0 to VDDQ 0 to VDDQ V VDDQ/2 VDDQ/2 VDDQ/2 VDDQ/2 V Figure 8. AC Measurement I/O Waveform Figure 9. AC Measurement Load Circuit VDDQ VDDQ VDDQ VDDQ/2 VDD 0V 16.7kΩ AI06161 DEVICE UNDER TEST CL 0.1µF 16.7kΩ 0.1µF CL includes JIG capacitance AI06162 Table 17. Capacitance Symbol CIN COUT Parameter Input Capacitance Output Capacitance Note: Sampled only, not 100% tested. 32/70 Test Condition Min Max Unit VIN = 0V 6 8 pF VOUT = 0V 8 12 pF M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 18. DC Characteristics - Currents Symbol Parameter Test Condition ILI Input Leakage Current ILO Output Leakage Current Supply Current Asynchronous Read (f=6MHz) IDD1 Supply Current Synchronous Read (f=40MHz) Supply Current Synchronous Read (f=54MHz) IDD2 Supply Current (Power-Down) IDD3 Supply Current (Standby) Min Typ Max Unit 0V ≤ VIN ≤ VDDQ ±1 µA 0V ≤ VOUT ≤ VDDQ ±1 µA E = VIL, G = VIH 3 6 mA 4 Word 6 13 mA 8 Word 8 14 mA Continuous 6 10 mA 4 Word 7 16 mA 8 Word 10 18 mA Continuous 13 25 mA RP = VSS ± 0.2V 2 10 µA E = VDD ± 0.2V 10 50 µA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA Program/Erase in one Bank, Asynchronous Read in another Bank 13 26 mA Program/Erase in one Bank, Synchronous Read in another Bank 16 30 mA E = VDD ± 0.2V 10 50 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP = VPPH 100 400 µA VPP ≤ VDD 0.2 5 µA VPP ≤ VDD 0.2 5 µA Supply Current (Program) IDD4 (1) Supply Current (Erase) Supply Current IDD5 (1,2) (Dual Operations) IDD6(1) Supply Current Program/ Erase Suspended (Standby) VPP Supply Current (Program) IPP1(1) VPP Supply Current (Erase) IPP2 IPP3(1) VPP Supply Current (Read) VPP Supply Current (Standby) Note: 1. Sampled only, not 100% tested. 2. VDD Dual Operation current is the sum of read and program or erase currents. 33/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 19. DC Characteristics - Voltages Symbol Parameter Test Condition Min Typ Max Unit VIL Input Low Voltage –0.5 0.4 V VIH Input High Voltage VDDQ –0.4 VDDQ + 0.4 V VOL Output Low Voltage IOL = 100µA 0.1 V VOH Output High Voltage IOH = –100µA VDDQ –0.1 VPP1 VPP Program Voltage-Logic Program, Erase 1 1.8 1.95 V VPPH VPP Program Voltage Factory Program, Erase 11.4 12 12.6 V VPPLK Program or Erase Lockout 0.9 V VLKO VDD Lock Voltage VRPH RP pin Extended High Voltage 34/70 V 1 V 3.3 V Hi-Z Hi-Z tELLH tLLLH tAVLH tELQV tAVQV tELTV tGLQV tAVAV Outputs Enabled tGLTV tGLQX tLHGL tLLQV tLHAX tELQX VALID Valid Address Latch Note. Write Enable, W, is High. DQ0-DQ15 WAIT G E L A0-A21 Data Valid VALID tAXQX tEHTZ tGHQZ tGHQX tEHQX tEHQZ Standby VALID AI90009b M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 10. Asynchronous Random Access Read AC Waveforms 35/70 36/70 DQ0-DQ15 WAIT G E L A0-A1 A2-A21 Hi-Z tELTV tELQX tGLQV tGLTV tGLQX tELQV tLLQV Valid Address Latch tELLH tLLLH tAVLH VALID ADDRESS tAVAV Enabled Outputs tLHGL tLHAX VALID DATA VALID DATA VALID ADDRESS Valid Data VALID DATA tAVQV1 VALID ADDRESS VALID ADDRESS VALID DATA VALID ADDRESS Standby AI90048c M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 11. Asynchronous Page Read AC Waveforms M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 20. Asynchronous Read AC Characteristics Symbol Alt Read Timings 85 90 100 120 Unit tAVAV tRC Address Valid to Next Address Valid Min 85 90 100 120 ns tAVQV tACC Address Valid to Output Valid (Random) Max 85 90 100 120 ns tAVQV1 tPAGE Address Valid to Output Valid (Page) Max 30 30 45 45 ns tAXQX (1) tOH Address Transition to Output Transition Min 0 0 0 0 ns Chip Enable Low to Wait Valid Max 14 14 14 18 ns tELTV tELQV (2) tCE Chip Enable Low to Output Valid Max 85 90 100 120 ns tELQX (1) tLZ Chip Enable Low to Output Transition Min 0 0 0 0 ns Chip Enable High to Wait Hi-Z Max 20 20 20 20 ns tEHTZ (1) tOH Chip Enable High to Output Transition Min 0 0 0 0 ns tEHQZ (1) tHZ Chip Enable High to Output Hi-Z Max 20 20 20 20 ns tGLQV (2) tOE Output Enable Low to Output Valid Max 25 25 25 25 ns tGLQX (1) tOLZ Output Enable Low to Output Transition Min 0 0 0 0 ns Output Enable Low to Wait Valid Max 14 14 14 18 ns tEHQX tGLTV Latch Timings M58CR064 Parameter tGHQX (1) tOH Output Enable High to Output Transition Min 0 0 0 0 ns tGHQZ (1) tDF Output Enable High to Output Hi-Z Max 20 20 20 20 ns tAVLH tAVADVH Address Valid to Latch Enable High Min 10 10 10 10 ns tELLH tELADVH Chip Enable Low to Latch Enable High Min 10 10 10 10 ns tLHAX tADVHAX Latch Enable High to Address Transition Min 10 10 10 10 ns tLLLH tADVLADVH Latch Enable Pulse Width Min 10 10 10 10 ns tLLQV tADVLQV Latch Enable Low to Output Valid (Random) Max 85 90 100 120 ns tLHGL tADVHGL Latch Enable High to Output Enable Low Min 10 10 10 10 ns Note: 1. Sampled only, not 100% tested. 2. G may be delayed by up to t ELQV - tGLQV after the falling edge of E without increasing tELQV . 37/70 38/70 Hi-Z tELKH Hi-Z tLLLH Address Latch tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS X Latency tGLTV tGLQX Note 1 tKHQV tKHKH VALID Valid Data Flow tKHQV VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal can be configured to be active during wait state or one cycle before. 3. Address latched and data output on the rising clock edge. WAIT G E K L A0-A21 DQ0-DQ15 Note 2 tKHTX tKHKL tKHQX tKHQX VALID Boundary Crossing Note 2 tKHTV tKHTX tKLKH tKHQV tKHQX NOT VALID Data Valid tGHQZ tGHQX AI90010b Standby tEHTZ tEHQZ tEHQX tEHEL VALID M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 12. Synchronous Burst Read AC Waveforms Hi-Z tELKH Hi-Z tLLLH tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS tGLTV tGLQV tGLQX Note 1 tKHQV Note 3 VALID tKHKH NOT VALID tKHKL NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal is configured to be active during wait state. 3. WAIT is always deasserted when addressed bank is in Read CFI, Read SR or Read electronic signature mode. WAIT signals valid data if the addressed bank is in Read Array mode. 4. Address latched and data output on the rising clock edge. WAIT(2) G E K(4) L A0-A21 DQ0-DQ15 NOT VALID tKLKH tGHQZ tGHQX tEHEL tEHQZ tEHTZ NOT VALID tEHQX NOT VALID AI06232 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 13. Single Synchronous Read AC Waveforms 39/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 21. Synchronous Read AC Characteristics M58CR064 Clock Specifications Synchronous Read Timings Symbol Alt Parameter Unit 90 100 120 tAVKH tAVCLKH Address Valid to Clock High Min 7 7 7 7 ns tELKH tELCLKH Chip Enable Low to Clock High Min 7 7 7 7 ns tELTV Chip Enable Low to Wait Valid Max 14 14 14 18 ns tEHEL Chip Enable Pulse Width (subsequent synchronous reads) Min 20 20 20 20 ns tEHTZ Chip Enable High to Wait Hi-Z Max 20 20 20 20 ns tKHAX tCLKHAX Clock High to Address Transition Min 10 10 10 10 ns tKHQV tKHTV tCLKHQV Clock High to Output Valid Clock High to WAIT Valid Max 14 14 14 18 ns tKHQX tKHTX tCLKHQX Clock High to Output Transition Clock High to WAIT Transition Min 4 4 4 4 ns tLLKH tADVLCLKH Latch Enable Low to Clock High Min 7 7 7 7 ns Clock Period (f=40MHz) Min 25 ns tKHKH tCLK Clock Period (f=54MHz) Min 18 18 18 ns tKHKL tCLKHCLKL Clock High to Clock Low Min 5 5 5 5 ns tKLKH tCLKLCLKH Clock Low to Clock High Max 5 5 5 5 ns Note: 1. Sampled only, not 100% tested. 2. For other timings please refer to Table 20, Asynchronous Read AC Characteristics. 40/70 85 K VPP WP DQ0-DQ15 W G E L A0-A21 tWLWH tLHAX COMMAND tLLLH SET-UP COMMAND tDVWH tGHWL tELWL tELLH tAVLH BANK ADDRESS tWHDX CMD or DATA tWHKV tWHEL tWHVPL tQVVPL tQVWPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS tWHWPL tWHQV tWHGL tWHAX tWHAV CONFIRM COMMAND OR DATA INPUT tVPHWH tWPHWH tWHWL tWHEH tWHLL tAVWH VALID ADDRESS tAVAV PROGRAM OR ERASE AI90011b M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 14. Write AC Waveforms, Write Enable Controlled 41/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 22. Write AC Characteristics, Write Enable Controlled M58CR064 Symbol tAVAV Alt tWC tAVLH 90 100 120 Address Valid to Next Address Valid Min 85 90 100 120 ns Address Valid to Latch Enable High Min 10 10 10 10 ns tWC Address Valid to Write Enable High Min 60 60 60 60 ns tDVWH tDS Input Valid to Write Enable High Min 40 40 40 40 ns Chip Enable Low to Latch Enable High Min 10 10 10 10 ns Chip Enable Low to Write Enable Low Min 0 0 0 0 ns tELQV Chip Enable Low to Output Valid Min 85 90 100 120 ns tGHWL Output Enable High to Write Enable Low Min 20 20 20 20 ns tLHAX Latch Enable High to Address Transition Min 10 10 10 10 ns tLLLH Latch Enable Pulse Width Min 10 10 10 10 ns tWHAV Write Enable High to Address Valid Min 0 0 0 0 ns tELWL Write Enable Controlled Timings Unit 85 tAVWH tELLH tCS tWHAX tAH Write Enable High to Address Transition Min 0 0 0 0 ns tWHDX tDH Write Enable High to Input Transition Min 0 0 0 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 0 0 0 ns Write Enable High to Chip Enable Low Min 50 50 50 50 ns tWHGL Write Enable High to Output Enable Low Min 0 0 0 0 ns tWHLL Write Enable High to Latch Enable Low Min 0 0 0 0 ns tWHKV Write Enable High to Clock Valid Min 25 25 25 25 ns tWHWL tWPH Write Enable High to Write Enable Low Min 30 30 30 30 ns Write Enable High to Output Valid Min 105 110 120 140 ns Write Enable Low to Write Enable High Min 50 50 50 50 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 0 0 ns VPP High to Write Enable High Min 200 200 200 200 ns tWHVPL Write Enable High to VPP Low Min 200 200 200 200 ns tWHWPL Write Enable High to Write Protect Low Min 200 200 200 200 ns tWPHWH Write Protect High to Write Enable High Min 200 200 200 200 ns tWHEL(2) tWHQV tWLWH Protection Timings Parameter tVPHWH tWP tVPS Note: 1. Sampled only, not 100% tested. 2. tWHEL has the values shown when reading in the targeted bank. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing a command. If the read operation is in a different bank tWHEL is 0ns. 42/70 K VPP WP DQ0-DQ15 E G W L A0-A21 tGHEL tELEH tLHAX COMMAND SET-UP COMMAND tDVEH tLLLH tELLH tWLEL tAVLH BANK ADDRESS tEHDX tEHEL tEHWH CMD or DATA tEHAX CONFIRM COMMAND OR DATA INPUT tVPHEH tWPHEH tAVEH VALID ADDRESS tAVAV tEHVPL tEHWPL tWHKV tWHEL tEHGL tQVVPL tQVWPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS PROGRAM OR ERASE AI90012b M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 15. Write AC Waveforms, Chip Enable Controlled 43/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 23. Write AC Characteristics, Chip Enable Controlled M58CR064 Symbol Alt Chip Enable Controlled Timings Unit 85 90 100 120 tAVAV tWC Address Valid to Next Address Valid Min 85 90 100 120 ns tAVEH tWC Address Valid to Chip Enable High Min 60 60 60 60 ns Address Valid to Latch Enable High Min 10 10 10 10 ns tAVLH tDVEH tDS Input Valid to Write Enable High Min 40 40 40 40 ns tEHAX tAH Chip Enable High to Address Transition Min 0 0 0 0 ns tEHDX tDH Chip Enable High to Input Transition Min 0 0 0 0 ns Min 30 30 30 30 ns Chip Enable High to Output Enable Low Min 0 0 0 0 ns Chip Enable High to Write Enable High Min 0 0 0 0 ns Min 60 60 60 60 ns tEHEL tWPH Chip Enable High to Chip Enable Low tEHGL tEHWH tCH tELEH tWP Chip Enable Low to Chip Enable High tELLH Chip Enable Low to Latch Enable High Min 10 10 10 10 ns tELQV Latch Enable Low to Output Valid Min 85 90 100 120 ns tGHEL Output Enable High to Chip Enable Low Min 20 20 20 20 ns tLHAX Latch Enable High to Address Transition Min 10 10 10 10 ns tLLLH Latch Enable Pulse Width Min 10 10 10 10 ns Write Enable High to Chip Enable Low Min 50 50 50 50 ns Write Enable High to Clock Valid Min 25 25 25 25 ns Write Enable Low to Chip Enable Low Min 0 0 0 0 ns tEHVPL Chip Enable High to VPP Low Min 200 200 200 200 ns tEHWPL Chip Enable High to Write Protect Low Min 200 200 200 200 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 0 0 ns Min 200 200 200 200 ns Min 200 200 200 200 ns tWHEL(2) tWHKV tWLEL Protection Timings Parameter tVPHEH tWPHEH tCS tVPS VPP High to Chip Enable High Write Protect High to Chip Enable High Note: 1. Sampled only, not 100% tested. 2. tWHEL has the values shown when reading in the targeted bank. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing a command. If the read operation is in a different bank tWHEL is 0ns. 44/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 16. Reset and Power-up AC Waveforms tPLWL tPLEL tPLGL tPLLL W, E, G, L RP tVDHPH tPLPH VDD, VDDQ Power-Up Reset AI90013c Table 24. Reset and Power-up AC Characteristics Symbol tPLWL tPLEL tPLGL tPLLL Parameter Reset Low to Write Enable Low, Chip Enable Low, Output Enable Low, Latch Enable Low Test Condition 85 90 100 120 Unit During Program Min 10 10 10 10 µs During Erase Min 20 20 20 20 µs Other Conditions Min 80 80 80 80 ns tPLPH (1,2) RP Pulse Width Min 50 50 50 50 ns tVDHPH (3) Supply Voltages High to Reset High Min 50 50 50 50 µs Note: 1. The device Reset is possible but not guaranteed if tPLPH < 50ns. 2. Sampled only, not 100% tested. 3. It is important to assert RP in order to allow proper CPU initialization during Power-Up or Reset. 45/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q PACKAGE MECHANICAL Figure 17. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Bottom View Package Outline D D1 SD FD FE E E1 e BALL "A1" ddd b e A2 A A1 BGA-Z20 Note: Drawing is not to scale. Table 25. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Package Mechanical Data millimeters inches Symbol Typ Min Max A 1.010 A1 0.250 Min Max 1.200 0.0398 0.0472 0.400 0.0098 0.0157 A2 0.790 0.0311 b 0.400 0.350 0.450 0.0157 0.0138 0.0177 D 6.500 6.400 6.600 0.2559 0.2520 0.2598 D1 5.250 – – 0.2067 – – ddd 46/70 Typ 0.100 0.0039 E 10.000 9.900 10.100 0.3937 0.3898 0.3976 E1 4.500 – – 0.1772 – – e 0.750 – – 0.0295 – – FD 0.625 – – 0.0246 – – FE 2.750 – – 0.1083 – – SD 0.375 – – 0.0148 – – M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 18. TFBGA56 Daisy Chain - Package Connections (Top view through package) 1 2 3 4 5 6 7 8 A B C D E F G AI07731 47/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 19. TFBGA56 Daisy Chain - PCB Connection Proposal (Top view through package) 1 2 3 4 5 6 7 8 START POINT A B C D E F G END POINT AI07755 48/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q PART NUMBERING Table 26. Ordering Information Scheme Example: M58CR064C 85 ZB 6 T Device Type M58 Architecture C = Dual Bank, Burst Mode Operating Voltage R = VDD = 1.65V to 2.0V, VDDQ = 1.65V to 3.3V Device Function 064C = 64 Mbit (x16), Dual Bank: 1/4-3/4 partitioning, Top Boot 064D = 64 Mbit (x16), Dual Bank: 1/4-3/4 partitioning, Bottom Boot 064P = 64 Mbit (x16), Dual Bank: 1/4-3/4 partitioning, Top Boot, VPP protection feature disabled 064Q = 64 Mbit (x16), Dual Bank: 1/4-3/4 partitioning, Bottom Boot, VPP protection feature disabled Speed 85 = 85ns 90 = 90ns 10 = 100ns 12 = 120ns Package ZB = TFBGA56: 6.5 x 10mm, 0.75 mm pitch Temperature Range 6 = –40 to 85°C Option T = Tape & Reel packing Table 27. Daisy Chain Ordering Scheme Example: M58CR064 -ZB T Device Type M58CR064 Daisy Chain ZB = TFBGA56: 6.5 x 10mm, 0.75 mm pitch Option T = Tape & Reel Packing Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact the ST Sales Office nearest to you. 49/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q APPENDIX A. BLOCK ADDRESS TABLES Table 28. Top Boot Block Addresses, M58CR064C, M58CR064P # Bank A 2F8000-2FFFFF 32 2F0000-2F7FFF Address Range 41 32 2E8000-2EFFFF 32 2E0000-2E7FFF 0 4 3FF000-3FFFFF 42 1 4 3FE000-3FEFFF 43 32 2D8000-2DFFFF 44 32 2D0000-2D7FFF 45 32 2C8000-2CFFFF 3FB000-3FBFFF 46 32 2C0000-2C7FFF 47 32 2B8000-2BFFFF 48 32 2B0000-2B7FFF 32 2A8000-2AFFFF 2 4 3FD000-3FDFFF 3 4 3FC000-3FCFFF 4 50/70 32 40 4 5 4 3FA000-3FAFFF 6 4 3F9000-3F9FFF 7 4 3F8000-3F8FFF 49 8 32 3F0000-3F7FFF 50 32 2A0000-2A7FFF 51 32 298000-29FFFF 52 32 290000-297FFF 32 288000-28FFFF 9 32 3E8000-3EFFFF 10 32 3E0000-3E7FFF 11 32 3D8000-3DFFFF 53 12 32 3D0000-3D7FFF 54 32 280000-287FFF 55 32 278000-27FFFF 13 32 3C8000-3CFFFF 14 32 3C0000-3C7FFF 56 32 270000-277FFF 15 32 3B8000-3BFFFF 57 32 268000-26FFFF 58 32 260000-267FFF 59 32 258000-25FFFF 32 250000-257FFF 248000-24FFFF 16 32 3B0000-3B7FFF 17 32 3A8000-3AFFFF Bank B Bank Size (KWord) 39 18 32 3A0000-3A7FFF 60 19 32 398000-39FFFF 61 32 62 32 240000-247FFF 32 238000-23FFFF 20 32 390000-397FFF 21 32 388000-38FFFF 63 22 32 380000-387FFF 64 32 230000-237FFF 65 32 228000-22FFFF 23 32 378000-37FFFF 24 32 370000-377FFF 66 32 220000-227FFF 32 218000-21FFFF 25 32 368000-36FFFF 67 26 32 360000-367FFF 68 32 210000-217FFF 69 32 208000-20FFFF 27 32 358000-35FFFF 28 32 350000-357FFF 70 32 200000-207FFF 71 32 1F8000-1FFFFF 72 32 1F0000-1F7FFF 29 32 348000-34FFFF 30 32 340000-347FFF 31 32 338000-33FFFF 73 32 1E8000-1EFFFF 32 1E0000-1E7FFF 32 32 330000-337FFF 74 33 32 328000-32FFFF 75 32 1D8000-1DFFFF 32 1D0000-1D7FFF 34 32 320000-327FFF 76 35 32 318000-31FFFF 77 32 1C8000-1CFFFF 78 32 1C0000-1C7FFF 36 32 310000-317FFF 37 32 308000-30FFFF 38 32 300000-307FFF Bank B M58CR064C, M58CR064D, M58CR064P, M58CR064Q 32 1B8000-1BFFFF 110 32 0C0000-0C7FFF 80 32 1B0000-1B7FFF 111 32 0B8000-0BFFFF 81 32 1A8000-1AFFFF 112 32 0B0000-0B7FFF 82 32 1A0000-1A7FFF 113 32 0A8000-0AFFFF 83 32 198000-19FFFF 114 32 0A0000-0A7FFF 84 32 190000-197FFF 115 32 098000-09FFFF 85 32 188000-18FFFF 116 32 090000-097FFF 86 32 180000-187FFF 117 32 088000-08FFFF 87 32 178000-17FFFF 118 32 080000-087FFF 88 32 170000-177FFF 119 32 078000-07FFFF 89 32 168000-16FFFF 120 32 070000-077FFF 90 32 160000-167FFF 121 32 068000-06FFFF 91 32 158000-15FFFF 122 32 060000-067FFF 92 32 150000-157FFF 123 32 058000-05FFFF 93 32 148000-14FFFF 124 32 050000-057FFF 94 32 140000-147FFF 125 32 048000-04FFFF 95 32 138000-13FFFF 126 32 040000-047FFF 96 32 130000-137FFF 127 32 038000-03FFFF 97 32 128000-12FFFF 128 32 030000-037FFF 98 32 120000-127FFF 129 32 028000-02FFFF 99 32 118000-11FFFF 130 32 020000-027FFF 100 32 110000-117FFF 131 32 018000-01FFFF 101 32 108000-10FFFF 132 32 010000-017FFF 102 32 100000-107FFF 133 32 008000-00FFFF 103 32 0F8000-0FFFFF 134 32 000000-007FFF 104 32 0F0000-0F7FFF 105 32 0E8000-0EFFFF 106 32 0E0000-0E7FFF 107 32 0D8000-0DFFFF 108 32 0D0000-0D7FFF 109 32 0C8000-0CFFFF Bank B 79 51/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 29. Bottom Boot Block Addresses, M58CR064D, M58CR064Q Bank B 32 2B8000-2BFFFF 2B0000-2B7FFF Size (KWord) Address Range 92 32 2A8000-2AFFFF 134 32 3F8000-3FFFFF 91 32 2A0000-2A7FFF 90 32 298000-29FFFF 89 32 290000-297FFF 32 288000-28FFFF 133 32 3F0000-3F7FFF 132 32 3E8000-3EFFFF 131 32 3E0000-3E7FFF 88 130 32 3D8000-3DFFFF 87 32 280000-287FFF 32 278000-27FFFF 129 32 3D0000-3D7FFF 86 128 32 3C8000-3CFFFF 85 32 270000-277FFF 127 32 3C0000-3C7FFF 84 32 268000-26FFFF 83 32 260000-267FFF 82 32 258000-25FFFF 32 250000-257FFF 126 32 3B8000-3BFFFF 125 32 3B0000-3B7FFF 124 32 3A8000-3AFFFF 81 123 32 3A0000-3A7FFF 80 32 248000-24FFFF 79 32 240000-247FFF 238000-23FFFF 122 32 398000-39FFFF 121 32 390000-397FFF 78 32 388000-38FFFF 77 32 230000-237FFF 76 32 228000-22FFFF 75 32 220000-227FFF 74 32 218000-21FFFF 73 32 210000-217FFF 72 32 208000-20FFFF 120 32 119 32 380000-387FFF 118 32 378000-37FFFF 117 32 370000-377FFF 116 32 368000-36FFFF 115 32 360000-367FFF 114 32 358000-35FFFF 71 32 200000-207FFF 32 1F8000-1FFFFF 113 32 350000-357FFF 70 112 32 348000-34FFFF 69 32 1F0000-1F7FFF 111 32 340000-347FFF 68 32 1E8000-1EFFFF 32 1E0000-1E7FFF 110 32 338000-33FFFF 67 109 32 330000-337FFF 66 32 1D8000-1DFFFF 65 32 1D0000-1D7FFF 108 32 328000-32FFFF 107 32 320000-327FFF 64 32 1C8000-1CFFFF 63 32 1C0000-1C7FFF 62 32 1B8000-1BFFFF 308000-30FFFF 61 32 1B0000-1B7FFF 32 1A8000-1AFFFF 106 32 318000-31FFFF 105 32 310000-317FFF 104 52/70 32 93 # Bank B Bank 94 32 103 32 300000-307FFF 60 102 32 2F8000-2FFFFF 59 32 1A0000-1A7FFF 58 32 198000-19FFFF 101 32 2F0000-2F7FFF 100 32 2E8000-2EFFFF 57 32 190000-197FFF 56 32 188000-18FFFF 55 32 180000-187FFF 99 32 2E0000-2E7FFF 98 32 2D8000-2DFFFF 97 32 2D0000-2D7FFF 96 32 2C8000-2CFFFF 95 32 2C0000-2C7FFF Bank A 54 32 178000-17FFFF 22 32 53 32 170000-177FFF 21 32 070000-077FFF 52 32 168000-16FFFF 20 32 068000-06FFFF 51 32 160000-167FFF 19 32 060000-067FFF 50 32 158000-15FFFF 18 32 058000-05FFFF 49 32 150000-157FFF 17 32 050000-057FFF 48 32 148000-14FFFF 16 32 048000-04FFFF 47 32 140000-147FFF 15 32 040000-047FFF 46 32 138000-13FFFF 14 32 038000-03FFFF 45 32 130000-137FFF 13 32 030000-037FFF 44 32 128000-12FFFF 12 32 028000-02FFFF 43 32 120000-127FFF 11 32 020000-027FFF 42 32 118000-11FFFF 10 32 018000-01FFFF 41 32 110000-117FFF 9 32 010000-017FFF 40 32 108000-10FFFF 8 32 008000-00FFFF 39 32 100000-107FFF 7 4 007000-007FFF 38 32 0F8000-0FFFFF 6 4 006000-006FFF 37 32 0F0000-0F7FFF 5 4 005000-005FFF 36 32 0E8000-0EFFFF 4 4 004000-004FFF 35 32 0E0000-0E7FFF 3 4 003000-003FFF 34 32 0D8000-0DFFFF 2 4 002000-002FFF 33 32 0D0000-0D7FFF 1 4 001000-001FFF 32 32 0C8000-0CFFFF 0 4 000000-000FFF 31 32 0C0000-0C7FFF 30 32 0B8000-0BFFFF 29 32 0B0000-0B7FFF 28 32 0A8000-0AFFFF 27 32 0A0000-0A7FFF 26 32 098000-09FFFF 25 32 090000-097FFF 24 32 088000-08FFFF 23 32 080000-087FFF Bank A Bank B M58CR064C, M58CR064D, M58CR064P, M58CR064Q 078000-07FFFF 53/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q APPENDIX B. COMMON FLASH INTERFACE The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when necessary. When the Read CFI Query Command is issued the device enters CFI Query mode and the data structure is read from the memory. Tables 30, 31, 32, 33, 34 and 35 show the addresses used to retrieve the data. The Query data is always presented on the lowest order data outputs (DQ0-DQ7), the other outputs (DQ8-DQ15) are set to 0. The CFI data structure also contains a security area where a 64 bit unique security number is written (see Figure 5, Security Block and Protection Register Memory Map). This area can be accessed only in Read mode by the final user. It is impossible to change the security number after it has been written by ST. Issue a Read Array command to return to Read mode. Table 30. Query Structure Overview Offset Sub-section Name Description 00h Reserved Reserved for algorithm-specific information 10h CFI Query Identification String Command set ID and algorithm data offset 1Bh System Interface Information Device timing & voltage information 27h Device Geometry Definition Flash device layout P Primary Algorithm-specific Extended Query table Additional information specific to the Primary Algorithm (optional) A Alternate Algorithm-specific Extended Query table Additional information specific to the Alternate Algorithm (optional) Security Code Area Lock Protection Register Unique device Number and User Programmable OTP 80h Note: The Flash memory display the CFI data structure when CFI Query command is issued. In this table are listed the main sub-sections detailed in Tables 31, 32, 33, 34 and 35. Query data is always presented on the lowest order data outputs. Table 31. CFI Query Identification String Offset Sub-section Name Description 00h 0020h Manufacturer Code 01h 88CAh 88CBh 8801h 8802h Device Code (M58CR064C/D/P/Q) 02h reserved Reserved 03h reserved Reserved 04h-0Fh reserved Reserved 10h 0051h 11h 0052h 12h 0059h 13h 0003h 14h 0000h 15h offset = P = 0039h 16h 0000h 17h 0000h 18h 0000h 19h value = A = 0000h 1Ah 0000h 54/70 Value ST Top Bottom "Q" Query Unique ASCII String "QRY" "R" "Y" Primary Algorithm Command Set and Control Interface ID code 16 bit ID code defining a specific algorithm Address for Primary Algorithm extended Query table (see Table 33) p = 39h Alternate Vendor Command Set and Control Interface ID Code second vendor - specified algorithm supported NA Address for Alternate Algorithm extended Query table NA M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 32. CFI Query System Interface Information Offset Data Description Value 1Bh 0017h VDD Logic Supply Minimum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 1.7V 1Ch 0020h VDD Logic Supply Maximum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 2.0V 1Dh 0017h VPP [Programming] Supply Minimum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 1.7V 1Eh 00C0h VPP [Programming] Supply Maximum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 12V 1Fh 0004h Typical time-out per single byte/word program = 2n µs 16µs 20h 0003h Typical time-out for quadruple word program = 2n µs 8µs 21h 000Ah Typical time-out per individual block erase = 2n ms 1s 22h 0000h Typical time-out for full chip erase = 2n ms NA 23h 0003h Maximum time-out for word program = 2n times typical 128µs 24h 0004h Maximum time-out for quadruple word = 2n times typical 128µs 25h 0002h Maximum time-out per individual block erase = 2n times typical 4s 26h 0000h Maximum time-out for chip erase = 2n times typical NA Table 33. Device Geometry Definition Data 27h 0017h Device Size = 2n in number of bytes 28h 29h 0001h 0000h Flash Device Interface Code description x16 Async. 2Ah 2Bh 0003h 0000h Maximum number of bytes in multi-byte program or page = 2n 8 Byte 2Ch 0002h Number of identical sized erase block regions within the device bit 7 to 0 = x = number of Erase Block Regions 2Dh 2Eh 007Eh 0000h Region 1 Information Number of identical-size erase blocks = 007Eh+1 2Fh 30h 0000h 0001h Region 1 Information Block size in Region 1 = 0100h * 256 byte 31h 32h 0007h 0000h Region 2 Information Number of identical-size erase blocks = 000Eh+1 33h 34h 0020h 0000h Region 2 Information Block size in Region 2 = 0020h * 256 byte 35h 38h 0000h Reserved for future erase block region information M58CR064C/P Offset Word Mode Description Value 8 MByte 2 127 64 KByte 8 8 KByte NA 55/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q M58CR064D/Q Offset Word Mode Data Description 2Dh 2Eh 0007h 0000h Region 1 Information Number of identical-size erase block = 0007h+1 2Fh 30h 0020h 0000h Region 1 Information Block size in Region 1 = 0020h * 256 byte 31h 32h 007Eh 0000h Region 2 Information Number of identical-size erase block = 007Eh+1 33h 34h 0000h 0001h Region 2 Information Block size in Region 2 = 0100h * 256 byte 35h 38h 0000h Reserved for future erase block region information Value 8 8 KByte 127 64 KByte NA Table 34. Primary Algorithm-Specific Extended Query Table Offset Data (P)h = 39h 0050h 0052h Description Value "P" Primary Algorithm extended Query table unique ASCII string “PRI” 0049h "R" "I" (P+3)h = 3Ch 0031h Major version number, ASCII "1" (P+4)h = 3Dh 0030h Minor version number, ASCII "0" (P+5)h = 3Eh 00E6h Extended Query table contents for Primary Algorithm. Address (P+5)h contains less significant byte. 0003h (P+7)h = 40h 0000h (P+8)h = 41h 0000h (P+9)h = 42h 0001h (P+A)h = 43h 0003h (P+B)h = 44h 0000h (P+C)h = 45h 56/70 0018h bit bit bit bit bit bit bit bit bit bit bit 0 1 2 3 4 5 6 7 8 9 10 to 31 Chip Erase supported (1 = Yes, 0 = No) Erase Suspend supported (1 = Yes, 0 = No) Program Suspend supported (1 = Yes, 0 = No) Legacy Lock/Unlock supported (1 = Yes, 0 = No) Queued Erase supported (1 = Yes, 0 = No) Instant individual block locking supported (1 = Yes, 0 = No) Protection bits supported (1 = Yes, 0 = No) Page mode read supported (1 = Yes, 0 = No) Synchronous read supported (1 = Yes, 0 = No) Simultaneous operation supported (1 = Yes, 0 = No) Reserved; undefined bits are ‘0’. If bit 31 is ’1’ then another 31 bit field of optional features follows at the end of the bit-30 field. Supported Functions after Suspend Read Array, Read Status Register and CFI Query bit 0 Program supported after Erase Suspend (1 = Yes, 0 = No) bit 7 to 1 Reserved; undefined bits are ‘0’ Block Protect Status Defines which bits in the Block Status Register section of the Query are implemented. bit 0 Block protect Status Register Lock/Unlock bit active (1 = Yes, 0 = No) bit 1 Block Lock Status Register Lock-Down bit active (1 = Yes, 0 = No) bit 15 to 2 Reserved for future use; undefined bits are ‘0’ VDD Logic Supply Optimum Program/Erase voltage (highest performance) bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV No Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Yes 1.8V M58CR064C, M58CR064D, M58CR064P, M58CR064Q Offset Data Description (P+D)h = 46h 00C0h VPP Supply Optimum Program/Erase voltage bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV (P+E)h = 47h (P+F)h = 48h (P+10)h = 49h (P+11)h = 4Ah (P+12)h = 4Bh 0000h Reserved Value 12V Table 35. Burst Read Information Offset Data Description Value (P+13)h = 4Ch 0003h Page-mode read capability bits 0-7 ’n’ such that 2n HEX value represents the number of readpage bytes. See offset 28h for device word width to determine page-mode data output width. (P+14)h = 4Dh 0003h Number of synchronous mode read configuration fields that follow. 3 (P+15)h = 4Eh 0001h Synchronous mode read capability configuration 1 bit 3-7 Reserved bit 0-2 ’n’ such that 2n+1 HEX value represents the maximum number of continuous synchronous reads when the device is configured for its maximum word width. A value of 07h indicates that the device is capable of continuous linear bursts that will output data until the internal burst counter reaches the end of the device’s burstable address space. This field’s 3-bit value can be written directly to the read configuration register bit 0-2 if the device is configured for its maximum word width. See offset 28h for word width to determine the burst data output width. 4 (P+16)h = 4Fh 0002h Synchronous mode read capability configuration 2 8 (P+17)h = 50h 0007h Synchronous mode read capability configuration 3 Cont. (P+18)h = 51h 0036h Max operating clock frequency (MHz) (P+19)h = 52h 0001h Supported handshaking signal (WAIT pin) bit 0 during synchronous read (1 = Yes, 0 = No) bit 1 during asynchronous read (1 = Yes, 0 = No) 8 Bytes 54 MHz Yes No 57/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q APPENDIX C. FLOWCHARTS AND PSEUDO CODES Figure 20. Program Flowchart and Pseudo Code Start program_command (addressToProgram, dataToProgram) {: writeToFlash (bank_address, 0x40) ; /*or writeToFlash (bank_address, 0x10) ; */ Write 40h or 10h writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06170 Note: 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 58/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 21. Double Word Program Flowchart and Pseudo code Start Write 30h double_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2) { writeToFlash (bank_address, 0x30) ; writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ /*Memory enters read status state after the Program command*/ Write Address 1 & Data 1 (3) Write Address 2 & Data 2 (3) do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.b7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; YES SR4 = 0 YES SR1 = 0 NO Program to Protected Block Error (1, 2) if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06171 Note: 1. Status check of b1 (Protected Block), b3 (V PP Invalid) and b4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 and Address 2 must be consecutive addresses differing only for bit A0. 59/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 22. Quadruple Word Program Flowchart and Pseudo Code Start quadruple_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2, addressToProgram3, dataToProgram3, addressToProgram4, dataToProgram4) { writeToFlash (bank_address, 0x55) ; Write 55h Write Address 1 & Data 1 (3) writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ Write Address 2 & Data 2 (3) writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ writeToFlash (addressToProgram3, dataToProgram3) ; /*see note (3) */ Write Address 3 & Data 3 (3) writeToFlash (addressToProgram4, dataToProgram4) ; /*see note (3) */ Write Address 4 & Data 4 (3) /*Memory enters read status state after the Program command*/ do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.b7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06172 Note: 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 to Address 4 must be consecutive addresses differing only for bits A0 and A1. 60/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 23. Program Suspend & Resume Flowchart and Pseudo Code Start program_suspend_command ( ) { writeToFlash (any_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if program has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR2 = 1 NO Program Complete YES Write FFh } Read data from another address Write D0h if (status_register.SR2==0) /*program completed */ { writeToFlash (bank_address, 0xFF) ; read_data ( ) ; /*read data from another block*/ /*The device returns to Read Array (as if program/erase suspend was not issued).*/ else { writeToFlash (bank_address, 0xFF) ; read_data ( ); /*read data from another address*/ writeToFlash (any_address, 0xD0) ; /*write 0xD0 to resume program*/ } Write FFh } Program Continues Read Data AI06173 61/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 24. Block Erase Flowchart and Pseudo Code Start erase_command ( blockToErase ) { writeToFlash (bank_address, 0x20) ; Write 20h writeToFlash (blockToErase, 0xD0) ; /* only A12-A20 are significannt */ /* Memory enters read status state after the Erase Command */ Write Block Address & D0h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1) YES Command Sequence Error (1) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; YES SR4, SR5 = 1 if ( (status_register.SR4==1) && (status_register.SR5==1) ) /* command sequence error */ error_handler ( ) ; NO SR5 = 0 NO Erase Error (1) if ( (status_register.SR5==1) ) /* erase error */ error_handler ( ) ; YES SR1 = 0 NO Erase to Protected Block Error (1) if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06174 Note: If an error is found, the Status Register must be cleared before further Program/Erase operations. 62/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 25. Erase Suspend & Resume Flowchart and Pseudo Code Start erase_suspend_command ( ) { writeToFlash (bank_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if erase has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR6 = 1 NO Erase Complete if (status_register.SR6==0) /*erase completed */ { writeToFlash (bank_address, 0xFF) ; YES read_data ( ) ; /*read data from another block*/ /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Write FFh Read data from another block or Program/Protection Program or Block Protect/Unprotect/Lock } else Write D0h Write FFh Erase Continues Read Data { writeToFlash (bank_address, 0xFF) ; read_program_data ( ); /*read or program data from another address*/ writeToFlash (bank_address, 0xD0) ; /*write 0xD0 to resume erase*/ } } AI06175 63/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 26. Locking Operations Flowchart and Pseudo Code Start locking_operation_command (address, lock_operation) { writeToFlash (bank_address, 0x60) ; /*configuration setup*/ Write 60h if (lock_operation==LOCK) /*to protect the block*/ writeToFlash (address, 0x01) ; else if (lock_operation==UNLOCK) /*to unprotect the block*/ writeToFlash (address, 0xD0) ; else if (lock_operation==LOCK-DOWN) /*to lock the block*/ writeToFlash (address, 0x2F) ; Write 01h, D0h or 2Fh writeToFlash (bank_address, 0x90) ; Write 90h Read Block Lock States Locking change confirmed? if (readFlash (address) ! = locking_state_expected) error_handler () ; /*Check the locking state (see Read Block Signature table )*/ NO YES writeToFlash (bank_address, 0xFF) ; /*Reset to Read Array mode*/ Write FFh } End AI06176 64/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Figure 27. Protection Register Program Flowchart and Pseudo Code Start protection_register_program_command (addressToProgram, dataToProgram) {: writeToFlash (bank_address, 0xC0) ; Write C0h writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06177 Note: 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 65/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q APPENDIX D. COMMAND INTERFACE STATE TABLES Table 36. Command Interface States - Lock table Current State of the Current Bank Current State of Other Bank Any State Mode State Read Array CFI Electronic Signature Status Setup Any State Lock Unlock Lock-Down CR Command Input to the Current Bank (and Next State of the Current Bank) Others Read Array (FFH) Erase Confirm P/E Resume Unlock Confirm (D0h) Read Status Register (70h) Block Lock Clear Read Unlock Block lock Read Status Electronic Lock-Down Confirm CFI Query Register Signature setup (01h) (98h) (50h) (90h) Set CR setup (60h) SEE Read MODIFY Read Array Read Array Status Read Array TABLE Register Block Lock Unlock Lock-Down Error, Set CR Error Block lock Block Lock Unlock Unlock Lock-Down Lock-Down Error, Set Block CR Error Block Lock Unlock Lock-Down Error, Set CR Error Block Lock Unlock Lock-Down Error, Set CR Error Read Elect. Sign. Read Elect. Sign. Read Elect. Sign. Done SEE Read MODIFY Read Array Read Array Status Read Array TABLE Register ProgramDouble/ Quadruple Program Done SEE Read MODIFY Read Array Read Array Status Read Array TABLE Register Setup Idle Erase Suspend Read Array, CFI, Program Elect. Suspend Sign., Status Setup Idle Any State Block/ Bank Erase Idle Program Suspend Erase Suspend Read Array, CFI, Elect. Sign., Status Block Lock Block Lock Block Lock Block Lock Unlock Unlock Unlock Unlock Lock-Down Lock-Down Lock-Down Lock-Down Error, Set Error, Set Block Block CR Error CR Error Set CR Block LocK Unlock Read CFI Lock-Down Read Array Read Array Read Array Setup, Set CR Setup Block LocK Unlock Read CFI Lock-Down Read Array Read Array Read Array Setup, Set CR Setup Block LocK Unlock Read CFI Lock-Down Read Array Read Array Read Array Setup, Set CR Setup Program (Busy) PS Read Status Register PS Read Array PS Read Elect. Sign. PS Read CFI PS Read Array PS Read Array PS Read Array PS Read Array Erase Error Erase Error Erase (Busy) Erase Error Erase Error Erase Error Erase Error Erase Error Erase Error Erase Error Erase Error SEE Read MODIFY Read Array Read Array Status Read Array TABLE Register Read Elect. Sign. Erase (Busy) ES Read Array Erase (Busy) ES Read Array ES Read Elect. Sign. SEE MODIFY TABLE ES Read Array Note: PS = Program Suspend, ES = Erase Suspend. 66/70 Block Lock, Unlock, Read CFI Lock-Down, Read Array Read Array Read Array Set CR Setup PS Read Array Error Done Set CR Confirm (03h) SEE MODIFY TABLE Setup Busy Block Lock Unlock Lock-Down Error, Set CR Error Error Lock SEE Read Unlock MODIFY Read Array Read Array Status Read Array Lock-Down TABLE Register Block Set CR Protection Any State Register Any State Read Elect. Sign. Block LockDown Confirm (2Fh) ES Read Status Register ES Read Array Block LocK Unlock Read CFI Lock-Down Read Array Read Array Read Array Setup, Set CR Setup ES Read CFI Block LocK Unlock ES Read Lock-Down Array Setup, Set CR Setup ES Read Array ES Read Array M58CR064C, M58CR064D, M58CR064P, M58CR064Q Table 37. Command Interface States - Modify Table Current State of the Other Bank Current State of the Current Bank Mode State Read Array, CFI, Electronic Signature, Status Register Setup Busy Idle Erase Suspend Program Suspend Setup Busy Idle Erase Suspend Program Suspend Idle Setup Busy Idle Lock Unlock Lock-Down CR Error, Lock Unlock Lock-Down Block, Set CR Setup Busy Done Busy Erase Suspend Idle Double/ Protection Quadruple Program-Erase Register Suspend (B0h) Program Setup Program Setup (30h/55h) (C0h) Bank Erase Setup (80h) Read Array Read Array Read Array Read Array Read Array Program setup Block Erase Setup Protection Register Setup Double/ Quadruple Program Setup Bank Erase Setup SEE LOCK TABLE Program Double/ Quadruple Word Program Done Read Array Read Array Read Array Read Array Read Array Read Array Program setup Block Erase Setup Protection Register Setup Double/ Quadruple Program Setup Bank Erase Setup Block/ Bank Erase Erase Suspend Read Array Read Array Read Array Read Array Read Array Read Array Read Array Protection Protection Protection Protection Protection Protection Protection Register (Busy) Register (Busy) Register (Busy) Register (Busy) Register (Busy) Register (Busy) Register (Busy) SEE LOCK TABLE Program Setup Read Array Block Erase Setup Read Array Read Array Read Array Protection Register Setup Read Array Read Array Double/ Quadruple Program Setup Read Array Read Array Bank Erase Setup Read Array Program (Busy) Program (Busy) Program (Busy) Program (Busy) PS Read Status Program (Busy) Program (Busy) Program (Busy) Register SEE LOCK TABLE Read Array Read Array Program Setup Block Erase Setup Read Array Program Suspend Read Array Read Array Read Array Setup Busy Idle Block Erase Setup (20h) Read Array Protection Register Setup Erase Suspend Program Suspend Setup Idle SEE LOCK TABLE Program Setup (10h/40h) Read Array Idle Idle Others Read Array Erase Suspend Program Suspend Any State Setup Busy Command Input to the Current Bank (and Next State of the Current Bank) Read Array Read Array Read Array Read Array Read Array Protection Register Setup Double/ Quadruple Program Setup Bank Erase Setup Read Array Read Array Read Array Read Array, CFI, Elect. Sign., Status Register SEE LOCK TABLE Setup SEE LOCK TABLE Erase Error Erase Error Erase Error Erase Error Erase Error Erase Error Busy Erase (Busy) Erase (Busy) Erase (Busy) ES Read Status Register Erase (Busy) Erase (Busy) Erase (Busy) Read Array, CFI, Elect. Sign., Status Register SEE LOCK TABLE Program Suspend PS Read Array PS Read Array PS Read Array PS Read Array PS Read Array PS Read Array ES Read Array ES Read Array Program Setup ES Read Array ES Read Array ES Read Array Double/ ES Read Array Quadruple Program Setup ES Read Array ES Read Array Note: PS = Program Suspend, ES = Erase Suspend. 67/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q REVISION HISTORY Table 38. Document Revision History Date Version November 2000 -01 First Issue 12/20/00 -02 Protection/Security clarification Memory Map diagram clarification (Figure 4) Single Synchronous Read clarification (Figure 6) Identifier Codes clarification (Table 6) X-Latency configuration clarification CFI Query Identification String change (Table 31) Synchronous Burst Read Waveforms change (Figure 12) Reset AC Characteristics clarification (Table 24) Program Time clarification (Table ) 1/08/01 -03 Reset AC Characteristics clarification (Table 24) Reset AC Waveforms diagram change (Figure 1) 3/02/01 -04 Document type: from Target Specification to Product Preview Read Status Register clarification Read Electronic Signature clarification Protection Register Program clarification Write Configuration Register clarification Wait Configuration Sequence change (Figure 7) CFI Query System Interface clarification (Table 32) CFI Device Geometry change (Table 33) Asynchronous Read AC Waveforms change (Figure 10) Page Read AC Waveforms added (Figure 11) Write AC Waveforms W Contr. and E Contr. change (Figure 14, 15) Reset and Power-up AC Characteristics and Waveform change (Table 24, Figure 1) TFBGA Package Mechanical Data and Outline added (Table 25, Figure 17) 4/05/01 -05 TFBGA Connections change X-Latency Configuration Sequence change Reset and Power-up AC Characteristics clarification VDDQ clarification 23-Jul-2001 -06 Complete rewrite and restructure 23-Oct-2001 -07 85ns speed class added, document classified as Preliminary Data 15-Mar-2002 -08 Part numbers M58CR064P/Q added. CFI information clarified: Table 31,data modified at Offset 13h. Table 32, data modified at Offsets 20h, 23h, 24h and 25h. Table 35, Offset addresses modified. DC Characteristics table modified, Program, Erase Times and Program, Erase Endurance Cycles table modified. 23-May-2002 -09 Document changed to new structure 27-Aug-2002 9.1 Revision numbering modified: a minor revision will be indicated by incrementing the digit after the dot, and a major revision, by incrementing the digit before the dot. (revision version 09 equals 9.0). Document status changed from Preliminary Data to Datasheet. Minimum VDD and VDDQ supply voltages for 85ns speed class changed to 1.8V in Table16, Operating and AC Measurement Conditions. 68/70 Revision Details M58CR064C, M58CR064D, M58CR064P, M58CR064Q Date Version Revision Details 24-Feb-2003 9.2 Revision History moved to end of document. 90ns Speed Class added. Bank Erase Command moved to Factory Program Commands section. Bank Erase cycles limited to 100 per Block. WAIT signal modified in Figure 7, Wait Configuration Example. WAIT behavior modified. Burst sequence in wrapped configuration and Burst sequence start specified in Synchronous Burst Read Mode paragraph. Erase replaced by Block Erase in Tables 11 and 12, Dual Operations allowed in Other Bank and in Same Bank, respectively. Latch signal corrected in Figure 11, Asynchronous Page Read AC Waveforms. Daisy Chain added. 06-Jun-2003 9.3 VDD and VDDQ minimum values changed for 90ns speed class in Table 16, Operating and AC Measurement Conditions. Minor text changes. 69/70 M58CR064C, M58CR064D, M58CR064P, M58CR064Q Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics. The ST logo is registered trademark of STMicroelectronics All other names are the property of their respective owners © 2003 STMicroelectronics - All Rights Reserved STMicroelectronics group of companies Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States. www.st.com 70/70