TOSHIBA TORX111

TORX111
FIBER OPTIC RECEIVING MODULE
TORX111
FIBER OPTIC RECEIVING MODULE
FOR APF
Unit: mm
l Non−connector (connector less) type
l Data rate: DC to 6 Mb / s (NRZ code)
l Transmission distance:
Up to 10 m (With TOTX111)
l TTL interface
1. Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Ratings
Unit
Storage Temperature
Tstg
−40 to 85
°C
Operating Temperature
Topr
−20 to 70
°C
Supply Voltage
VCC
−0.5 to 7
V
High Level Output Current
IOH
−1
mA
Low Level Output Current
IOL
20
mA
Clamped Fiber Bearable Force
FCB
19.6 (Note 1)
N
Soldering Temperature
Tsol
260 (Note 2)
°C
Note 1: Pulling in the axial direction. Momentary value.
Note 2: Soldering time ≤ 3 s (More than 1 mm apart from the package).
1
2001-08-31
TORX111
2. Recommended Operating Conditions
Characteristics
Supply Voltage
Symbol
Min
Typ.
Max
Unit
VCC
4.75
5.0
5.25
V
Load Impedance
(Note 3)
―
―
10
KΩ
Load Capacitor
(Note 3)
―
―
10
pF
Note 3: Load of analogue output.
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
Characteristics
Symbol
Test Condition
(Note 4)
Min
Typ.
Max
Unit
DC
―
6
Mb / s
Data Rate
NRZ code
Transmission Distance
APF (Note 5) with TOTX111
0.2
―
10
m
Pulse width 165 ns
Pulse cycle 330 ns
CL = 10 pF
−55
―
55
ns
Pulse Width Distortion
(Note 6)
∆tw
Maximum Receivable
Power
(Note 7)
PMAX
APF (Note 5), 6 Mb / s NRZ code
−4.5
―
―
dBm
Minimum Receivable
Power
(Note 7)
PMIN
APF (Note 5), 6 Mb / s NRZ code
―
―
−22
dBm
―
12
20
mA
PIN = −4.5 to −22 dBm
2.3
―
2.8
V
PIN = −∞ dBm
1.6
―
―
V
Current Consumption
ICC
Analogue Output Voltage
VA
High Level Output Voltage
VOH
4.6
―
―
V
Low Level Output Voltage
VOL
―
―
0.4
V
Min
Typ.
Max
Unit
Note 4:
Note 5:
Note 6:
Note 7:
When optical input is on, output level is high. Optical input is off, output is low.
All Plastic Fiber (980 µm core, 1000 µm cladding).
Between input of TOTX111 and digital output of TORX111.
−9
BER ≤ 10 . Peak value.
4. Mechanical Characteristics (Ta = 25°C)
Characteristics
Symbol
Fiber Insert Force
Test Condition
FFI
Using TOFC100, First value
―
6
19.6
N
Fiber Clamping Force
(Note 8)
FFC
Using TOFC100, First value
19.6
35
―
N
Ring Unclamping Force
(Note 9)
FRC
Using TOFC100, First value
―
10
19.6
N
Note 8: The optical fiber is disconnected when it is pulled with this load in the axial direction.
Note 9: This is the load required for the clamp release ring to release the optical fiber clamp.
When disconnecting the optical fiber, hold in the clamp release ring.
2
2001-08-31
TORX111
5. Example of Typical Characteristics (Note 10)
Note 10: There give characteristic examples, and its values are not guaranteed.
3
2001-08-31
TORX111
Note 10: There give characteristic examples, and its values are not guaranteed.
4
2001-08-31
TORX111
Note 10: There give characteristic examples, and its values are not guaranteed.
5
2001-08-31
TORX111
Note 10: There give characteristic examples, and its values are not guaranteed.
6. Application Circuit
6
2001-08-31
TORX111
7. Precautions during use
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Maximum rating
The maximum ratings are the limit values which must not be exceeded during operation of device.
None of these rating value must not be exceeded. If the maximum rating value is exceeded, the
characteristics of devices may never be restored properly. In extreme cases, the device may be
permanently damages.
Soldering
Optical modules are comprised of internal semiconductor devices. However, in principle, optical
modules are optical components. During soldering, ensure that flux does not contact with the emitting
surface or the detecting surface. Also ensure that proper flux removal is conducted after soldering.
Some optical modules come with a protective cap. The protective cap is used to avoid malfunction
when the optical module is not in use. Note that it is not dust or waterproof.
As mentioned before, optical modules are optical components. Thus, in principle, soldering where
there may be flux residue and flux removal after soldering is not recommended. Toshiba recommend
that soldering be performed without the optical module mounted on the board. Then, after the board
has been cleaned, the optical module should be soldered on to the board manually.
If the optical module cannot be soldered manually, use non−halogen (chlorine−free) flux and make
sure, without cleaning, there is no residue such as chlorine. This is one of the ways to eliminate the
effects of flux. In such a cases, be sure to check the devices’reliability.
Noise resistance
It is believed that the use of optical transfer devices improve noise resistance. In theory, optical fiber
is not affected by noise at all. However, receiving modules which handle signals whose level is
extremely small, are susceptible to noise.
TOSLINK improve noise resistance to use a conductive case. However, the current signal output by
the optical receiving modules' photodiode is extremely small. Thus, in some environments, shielding
the case may not achieve sufficient noise resistance.
First systems which incorporate TOSLINK, Toshiba recommend testing using the actual device to
check its noise resistance.
Use a simple noise filter on TOSLINK fiber optic transceiving module's power line. If the ripple in the
power supply used is significant, reinforce the filter.
The optical module is to be used in an area which is susceptible to radiated noise, increase the
shielding by covering the optical module and the power line filter with a metallic cover.
Vibration and shock
This module is plastic sealed and has its wire fixed by resin. This structure is relatively resistant to
vibration and shock. In actual equipment, there are sometime cases in which vibration, shock, or
stress is applied to soldered parts or connected parts, resulting in lines cut. A care must be taken in
the design of equipment which will be subject to high levels of vibration.
Fixing fiber optical receiving module
Solder the fixed pin (pins 5 and 6) of fiber optic receiving module TORX111 to the printed circuit
board to fix the module to the board.
Solvent
When using solvent for flux removal, do not use a high acid or high alkali solvent. Be careful not to
pour solvent in to the optical connector ports. If solvent is inadvertently poured in to them, clean it off
using cotton tips.
Dirt
Note that dirt should not be in to a module.
Optical fiber
Use TOFC100 or similar product for optical fiber. When cutting optical fiber, use an edged tool such
as a cutter knife.
Removing the optical fiber from the module
When removing the optical fiber from the module, push the ring. Note that not to pull the optical fiber
out from the module without pushing the ring. The tip of the optical fiber may be cut off and remain
in the module.
7
2001-08-31
TORX111
(10) Shielding and wiring pattern of fiber optic receiving modules
To shield, connect the fixed pins (pins 5 and 6) of fiber optic transceiving module TORX111 to the
GND.
Where the fiber optic receiving module uses metal material, be careful that the case does not touch
wiring (including land).
To improve noise resistance, shield the optical module and the power line filter using a metallic cover.
(11) Supply voltage
Use the supply voltage within the recommended operating condition (VCC = 5 ± 0.25 V). Make sure
that supply voltage does not exceed the maximum rating value of 7 V, even for an instant.
(12) Output
If the receiver output is at low and is connected to the power supply, or if the output is high and is
connected to GND, the internal IC may be destroyed.
(13) Analogue Output
Pin No.2, fiber optic receiving module TORX111, is analog output terminal for observing the received
optical power as a result of measuring analog output voltage.
When LED or other devices connect to analog output, use the buffer circuit.
When analog output terminal is not used, do not connect any circuit to it.
(14) Soldering condition
Solder at 260°C or less for no more than three seconds.
(15) Precautions when disposing of devices and packing materials.
When disposing devices and packing materials, follow the procedures stipulated by local regulations
in order to protect the environment against contamination.
When devices are disposed of, worker safety and protection of the environment must be taken into
account.
(16) Precautions during use
Toshiba is continually working to improve the quality and the reliability of their products.
Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical
sensitivity and their vulnerability to physical stress. It is the responsibility of the buyer, when
utilizing Toshiba products, to observe standards of safety, and to avoid situations in which the
malfunction or failure of a Toshiba product could cause loss of human life, bodily injury or damage to
property.
When developing equipment, please ensure that Toshiba products are used within the specified
operating ranges set forth in the most recent product specifications. Also, please keep in mind the
precautions and conditions set forth in the Toshiba Semiconductor Reliability Handbook.
8
2001-08-31
TORX111
RESTRICTIONS ON PRODUCT USE
000707EAA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
9
2001-08-31