TOSHIBA TOTX195

TOTX195
FIBER OPTIC TRANSMITTING MODULE
TOTX195
FIBER OPTIC TRANSMITTING
MODULE FOR SIMPLEX DIGITAL
SIGNAL TRANSMISSION
Unit: mm
l Data rate : DC to 10 Mb/s (NRZ code)
l Transmission distance: Up to 50 m
l TTL interface
l LED is driven by Differential circuit.
1. Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Rating
Unit
Storage Temperature
Tstg
−40 to 85
°C
Operating Temperature
Topr
−40 to 85
°C
Supply Voltage
VCC
−0.5 to 7
V
Input Voltage
VIN
−0.5 to VCC + 0.5
V
Soldering Temperature
Tsol
260 (Note 1)
°C
Note 1: Soldering time ≤ 3 s (More than 1 mm apart from the package).
Handling precaution: The LEDs used in this product contain GaAs (Gallium Arsenide).
Care must be taken to protect the safety of people and the environment when scrapping or
terminal processing.
1
2001-08-10
TOTX195
2. Recommended Operating Conditions
Characteristics
Symbol
Min
Typ.
Max
Unit
Supply Voltage
VCC
4.75
5.0
5.25
V
High Level Input Voltage
VIH
2.0
―
VCC
V
Low Level Input Voltage
VIL
0
―
0.8
V
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
Characteristics
Symbol
Test Condition
Typ.
Max
Unit
DC
―
10
Mb / s
Data Rate
NRZ Code
Transmission Distance
Using APF (Note 3) and TORX194
0.2
―
50
m
Using APF and TORX194
Pulse width 100 ns
Pulse cycle 200 ns, CL = 10 pF
−30
―
30
ns
APF 1 m, R = 1.2 kΩ
−11
―
−6
dBm
―
670
―
nm
―
40
55
mA
Pulse Width Distortion
(Note 4)
∆tw
(Note 2)
Min
Fiber Output Power
Pf
Peak Emission Wavelength
λp
Current Consumption
ICC
High Level Input Voltage
VIH
2.0
―
―
V
Low Level Input Voltage
VIL
―
―
0.8
V
High Level Input Current
IIH
VI = 2.7 V
―
―
20
µA
Low Level Input Current
IIL
VI = 0.4 V
―
―
−0.4
mA
Note 2:
Note 3:
Note 4:
Note 5:
R = 1.2 kΩ
(Note 5)
LED is on when input signal is high level, it is off when low level.
All Plastic Fiber (980/1000 µm) with polished surface.
Between input of TOTX195 and output of TORX194.
Measure with a standard optical fiber with fiber optic connectors. Valued by peak.
2
2001-08-10
TOTX195
4. Example of Typical Characteristics (Note 6)
Note 6: There give characteristic examples, and its values are not guaranteed.
3
2001-08-10
TOTX195
Note 6: There give characteristic examples, and its values are not guaranteed.
4
2001-08-10
TOTX195
5. Application Circuit
Note 7: Select a resistor value as follows:
Transmission Distance
(m)
Resistor
(Ω)
0.2 to 10
17.8 k
10 to 30
6.2 k
30 to 50
1.2 k
6. Applicable Optical Fiber with Fiber Optic Connectors
TOCP100−□□B, TOCP155−□□B, TOCP100P−□□B, TOCP155P−□□B
5
2001-08-10
TOTX195
7. Precautions during use
(1)
Maximum rating
The maximum ratings are the limit values which must not be exceeded during operation of device.
None of these rating value must not be exceeded. If the maximum rating value is exceeded, the
characteristics of devices may never be restored properly. In extreme cases, the device may be
permanently damages.
(2) Lifetime of light emitters
If an optical module is used for a long period of time, degeneration in the characteristics will mostly
be due to a lowering of the fiber output power (Pf). This is caused by the degradation of the optical
output of the LEDs used as the light source. The cause of degradation of the optical output of the
LEDs may be defects in wafer crystallization or mold resin stress. The detailed causes are, however,
not clear.
The lifetime of light emitters is greatly influenced by the operating conditions and the environment in
which it is used as well as by the lifetime characteristics unique to the device type. Thus, when a light
emitting device and its operating conditions determined, Toshiba recommend that lifetime
characteristics be checked.
Depending on the environment conditions, Toshiba recommend that maintenance such as regular
checks of the amount of optical output in accordance with the condition of operating environment.
(3) Soldering
Optical modules are comprised of internal semiconductor devices. However, in principle, optical
modules are optical components. During soldering, ensure that flux does not contact with the emitting
surface or the detecting surface. Also ensure that proper flux removal is conducted after soldering.
Some optical modules come with a protective cap. The protective cap is used to avoid malfunction
when the optical module is not in use. Note that it is not dust or waterproof.
As mentioned before, optical modules are optical components. Thus, in principle, soldering where
there may be flux residue and flux removal after soldering is not recommended. Toshiba recommend
that soldering be performed without the optical module mounted on the board. Then, after the board
has been cleaned, the optical module should be soldered on to the board manually.
If the optical module cannot be soldered manually, use non−halogen (chlorine−free) flux and make
sure, without cleaning, there is no residue such as chlorine. This is one of the ways to eliminate the
effects of flux. In such a cases, be sure to check the devices’ reliability.
(4) Vibration and shock
This module is plastic sealed and has its wire fixed by resin. This structure is relatively resistant to
vibration and shock. In actual equipment, there are sometime cases in which vibration, shock, or
stress is applied to soldered parts or connected parts, resulting in lines cut. A care must be taken in
the design of equipment which will be subject to high levels of vibration.
(5) Attaching the fiber optic transmitting module
Solder the fixed pins (pins 4 and 5) of the fiber optic transmitting module TOTX195 to the printed
circuit board in order to fix it to the board.
(6) Solvent
When using solvent for flux removal, do not use a high acid or high alkali solvent. Be careful not to
pour solvent in to the optical connector ports. If solvent is inadvertently poured in to them, clean it off
using cotton tips.
(7) Protective cap
When the TOTX195 is not in use, attach the protective cap.
(8) Supply voltage
Use the supply voltage within the recommended operating condition (VCC = 5 ± 0.25 V). Make sure
that supply voltage does not exceed the maximum rating value of 7 V, even for an instant.
(9) Input voltage
If a voltage exceeding the maximum rating value (VCC + 0.5 V) is applied to the transmitter input,
the internal IC may suffer damage. If there is a possibility that excessive voltage due to surges may
be added to the input terminal, insert a protective circuit.
(10) Soldering condition
Solder at 260°C or less for no more than three seconds.
(11) Precautions when disposing of devices and packing materials.
When disposing devices and packing materials, follow the procedures stipulated by local regulations
in order to protect the environment against contamination.
Compound semiconductors such as GaAs are used as LED materials in this module. When devices are
disposed of, worker safety and protection of the environment must be taken into account.
6
2001-08-10
TOTX195
(12) Precautions during use
Toshiba is continually working to improve the quality and the reliability of their products.
Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical
sensitivity and their vulnerability to physical stress. It is the responsibility of the buyer, when
utilizing Toshiba products, to observe standards of safety, and to avoid situations in which the
malfunction or failure of a Toshiba product could cause loss of human life, bodily injury or damage to
property.
When developing equipment, please ensure that Toshiba products are used within the specified
operating ranges set forth in the most recent product specifications. Also, please keep in mind the
precautions and conditions set forth in the Toshiba Semiconductor Reliability Handbook.
7
2001-08-10
TOTX195
RESTRICTIONS ON PRODUCT USE
000707EAC
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes
are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the
products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with
domestic garbage.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
8
2001-08-10