RG2 - RG2Z ULTRA FAST RECOVERY RECTIFIER DIODES PRV : 200 - 400 Volts Io : 1.2 Amperes D2 FEATURES : * * * * * * * High current capability High surge current capability High reliability Low reverse current Low forward voltage drop Fast switching for high efficiency Pb / RoHS Free 1.00 (25.4) MIN. 0.161 (4.1) 0.154 (3.9) 0.284 (7.21) 0.268 (6.81) MECHANICAL DATA : 1.00 (25.4) MIN. 0.034 (0.86) 0.028 (0.71) * Case : D2 Molded plastic * Epoxy : UL94V-O rate flame retardant * Lead : Axial lead solderable per MIL-STD-202, Method 208 guaranteed * Polarity : Color band denotes cathode end * Mounting position : Any * Weight : 0.465 gram Dimensions in inches and ( millimeters ) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating at 25 °C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. RATING SYMBOL RG2Z RG2 UNIT Maximum Peak Reverse Voltage VRM 200 400 V Maximum Peak Reverse Surge Voltage VRSM 200 400 V Maximum Average Forward Current Ta = 60 °C IF(AV) 1.2 A IFSM 50 A Maximum Peak Forward Surge Current (50 Hz, Half-cycle, Sine wave, Single Shot) 1.5 1.8 Maximum Forward Voltage at IF = 1.5A VF Maximum Reverse Current at VR = VRM Ta = 25 °C IR 0.5 mA Maximum Reverse Current at VR = VRM Ta = 100 °C IR(H) 2.5 mA Maximum Reverse Recovery Time ( Note 1 ) Trr 100 ns Junction Temperature Range TJ - 40 to + 150 °C Storage Temperature Range TSTG - 40 to + 150 °C V Notes : ( 1 ) Reverse Recovery Test Conditions : IF = 100 mA, IRP = 100 mA. Page 1 of 2 Rev. 03 :September 7, 2005 RATING AND CHARACTERISTIC CURVES ( RG2 - RG2Z ) FIG.1 - REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM 100 µF specimen 100 mA 100 mA IF IRP 10 Ω 20µS 0.1 IRP 200µS Trr NOTE : IF = IRP = 100 mA TO 10 mA FIG.2 - DERATING CURVE FOR OUTPUT RECTIFIED CURRENT FIG.3 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT 50 PEAK FORWARD SURGE CURRENT, AMPERES AVERAGE FORWARD OUTPUT CURRENT, AMPERES 1.5 1.2 0.9 0.6 0.3 0 0 25 50 75 100 125 150 40 30 20 10 0 175 1 AMBIENT TEMPERATURE, ( °C) 10 FORWARD CURRENT, AMPERES 4 6 10 20 40 60 100 FIG.5 - TYPICAL REVERSE CHARACTERISTICS REVERSE CURRENT, MICROAMPERES FIG.4 - TYPICAL FORWARD CHARACTERISTICS 1.0 Ta = 25 °C 0.1 2 NUMBER OF CYCLES AT 50Hz 0.01 10 TJ = 100 °C 1.0 0.1 TJ = 25 °C 0.0 0 20 40 60 80 100 12 140 PERCENT OF RATED REVERSE VOLTAGE, (%) 0.001 0.2 0.6 1.0 1.4 1.8 2.2 2.6 2.8 FORWARD VOLTAGE, VOLTS Page 2 of 2 Rev. 03 :September 7, 2005