FEATURES
SY100E241
DESCRIPTION
■ 1000ps max. CLK to output
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E241 are 8-bit shiftable registers designed
for use in new, high-performance ECL systems. Unlike the
E141, the E241 features internal data feedback organized
such that the SHIFT control overrides the HOLD, /LOAD
control. Thus, the normal operations of HOLD and LOAD
can be toggled with a single control line without the need for
external gating. This configuration also enables switching
to scan mode with the single SHIFT control line.
The eight inputs D0–D7 accept parallel input data, while
S-IN accepts serial input data when in shift mode. Data is
accepted a set-up time before the rising edge of CLK.
Shifting is also accomplished on the rising clock edge. A
HIGH on the Master Reset pin (MR) asychronously resets
all the registers to zero.
■
■
■
■
SHIFT overrides HOLD, /LOAD control
Asynchronous Master Reset
Pin-compatible with E141
Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E241
■ Available in 28-pin PLCC package
PIN NAMES
BLOCK DIAGRAM
Pin
S-IN
D
D0
Q
Q0
R
D
D1 – D6
Q
Q1 – Q6
R
Function
D0–D7
Parallel Data Inputs
S-IN
Serial Data Input
SEL0
SHIFT Control
SEL1
HOLD, /LOAD Control
CLK
Clock
MR
Master Reset
Q0–Q7
Data Outputs
VCCO
VCC to Output
BITS 1-6
D
D7
Q
Q7
R
SEL1 (HOLD/LOAD)
SEL0 (SHIFT)
CLK
MR
M9999-032206
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: December 2005
SY10E241
SY100E241
Micrel, Inc.
Ordering Information(1)
Q7
D5
VCCO
D7
D6
SEL0
NC
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
J28-1
Commercial
SY10E241JC
Sn-Pb
SEL1
26
18
Q6
SY10E241JC
CLK
MR
27
17
Q5
VCC
SY10E241JCTR(2)
J28-1
Commercial
SY10E241JC
Sn-Pb
SY100E241JC
J28-1
Commercial
SY100E241JC
Sn-Pb
SY100E241JCTR(2)
J28-1
Commercial
SY100E241JC
Sn-Pb
SY10E241JZ(3)
J28-1
Commercial
SY10E241JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E241JZTR(2, 3)
J28-1
Commercial
SY10E241JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E241JZ(3)
J28-1
Commercial
SY100E241JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E241JZTR(2, 3)
J28-1
Commercial
SY100E241JZ with
Pb-Free bar-line indicator
Matte-Sn
1
2
16
15
14
3
13
4
12
6
D2
D3
5
7
8
9
10 11
NC
VCCO
Q4
Q3
Q0
Q1
Q2
D0
D1
TOP VIEW
PLCC
J28-1
D4
VCCO
VEE
S-IN
28
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032206
[email protected] or (408) 955-1690
2
SY10E241
SY100E241
Micrel, Inc.
TRUTH TABLE
SEL0
SEL1
Function
L
L
Load
L
H
Hold
H
X
Shift (Dn to Dn+1)
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
Min. Typ. Max. Min. Typ.
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
TA = +85°C
Max. Min.
Typ.
Max.
Unit
Condition
µA
—
mA
—
—
—
150
—
—
150
—
—
150
—
—
125
125
150
150
—
—
125
125
150
150
—
—
125
144
150
173
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
Min. Typ. Max. Min. Typ.
TA = +85°C
Max. Min. Typ.
Max.
Unit
Condition
MHz
—
ps
—
ps
—
ps
—
fSHIFT
Max. Shift Frequency
700
900
—
700
900
—
700
900
—
tPD
Propagation Delay to Output
CLK
MR
625
600
750
725
975
975
625
600
750
725
975
975
625
600
750
725
975
975
Set-up Time
D
SEL0 (SHIFT)350
SEL1 (HOLD/LOAD)
S-IN
175
200
400
125
25
—
250
–100
—
350
—
—
175
200
400
125
25
—
250
–100
—
350
—
—
175
200
400
125
25
—
250
–100
—
Hold Time
D
SEL0 (SHIFT)
SEL1 (HOLD/LOAD)
S-IN
200
100
50
300
–25
–200
–250
100
—
—
—
—
200
100
50
300
–25
–200
–250
100
—
—
—
—
200
100
50
300
–25
–200
–250
100
—
—
—
—
tRR
Reset Recovery Time
900
600
—
900
600
—
900
600
—
ps
—
tPW
Minimum Pulse Width
CLK, MR
400
—
—
400
—
—
400
—
—
ps
—
tskew
Within-Device Skew
—
60
—
—
60
—
—
60
—
ps
1
tr
tf
Rise/Fall Time
20% to 80%
300
525
800
300
525
800
300
525
800
ps
—
tS
tH
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
M9999-032206
[email protected] or (408) 955-1690
3
—
—
SY10E241
SY100E241
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032206