Micrel, Inc. QUINT EXCLUSIVE OR/NOR GATE FEATURES ■ ■ ■ ■ ■ ■ ■ ■ DESCRIPTION The SY100S307 is an ultra-fast quint exclusive-OR/NOR gate designed for use in high-performance ECL systems. A function output that is the wire-OR result of the exclusive-OR outputs is also available. The inputs on the device have 75kΩ pull-down resistors. Max. propagation delay of 1000ps IEE min. of –58mA Extended supply voltage option: VEE = –4.2V to –5.5V Voltage and temperature compensation for improved noise immunity Internal 75kΩ input pull-down resistors 50% faster than Fairchild 300K at lower power Function and pinout compatible with Fairchild F100K Available in 28-pin PLCC package block DIAGRAM PIN NAMES M9999-060910 [email protected] or (408) 955-1690 SY100S307 SY100S307 1 Pin Function Dna – Dne Data Inputs (n-1...5) E Enable Input Oa – Oe Data Outputs Oa – Oe Complementary Data Outputs VEES VEE Substrate VCCA VCCO for ECL Outputs Rev.: I Amendment: /0 Issue Date: June 2010 SY100S307 Micrel, Inc. PACKAGE/ORDERING INFORMATION Ordering Information Part Number SY100S307JC SY100S307JCTR (1) Package Type Operating Range Package Marking Lead Finish J28-1 Commercial SY100S307JC Sn-Pb J28-1 Commercial SY100S307JC Sn-Pb SY100S307JZ(2) J28-1 Commercial SY100S307JZ with Matte-Sn Pb-Free bar-line indicator SY100S307JZTR(1, 2) J28-1 Commercial SY100S307JZ with Pb-Free bar-line indicator SY100S307JY with SY100S307JY(2) J28-1 Industrial Pb-Free bar-line indicator SY100S307JYTR(1,2) 28-Pin PLCC (J28-1) J28-1 Industrial Notes: 1.Tape and Reel. 2.Pb-Free package is recommended for new designs. M9999-060910 [email protected] or (408) 955-1690 2 Matte-Sn Matte-Sn SY100S307JY with Matte-Sn Pb-Free bar-line indicator SY100S307 Micrel, Inc. LOGIC EQUATION F = (D1a+ D2a) + (D1b + D2b) + (D1c +D2c) + (D1d +D2d) + (D1e +D2e). DC ELECTRICAL CHARACTERISTICS VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND Symbol IIH IEE Parameter Min. Unit Condition Input HIGH Current D2a — D2e — — 200 D2a — D2e — — 250 µA VIN = VIH (Max.) Power Supply Current mA Inputs Open –58 Typ. Max. –40 –27 AC ELECTRICAL CHARACTERISTICS VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND TA = -40°C T A = 0°C TA = +25°C TA = +85°C Symbol Min. Max. Max. Min. Max. Min. Min. Parameter Max. Unit Condition tPLH tPH2 Propagation Delay 300 300 1000 D2a — D2e to O, O 1000 300 1000 300 1000 ps tPLH tPHL Propagation Delay 300 900 300 D1a — D1e to O, O 900 300 900 300 930 ps tPLH tPHL Propagation Delay 1425 300 300 1425 300 1425 300 1425 Data to F ps tTLH tTHL Transition Time 3 20% to 80%, 80% to 20% ps 00 900 900 00 300 TIMING DIAGRAM Propagation Delay and Transition Times NOTE: VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND M9999-060910 [email protected] or (408) 955-1690 3 900 300 900 SY100S307 Micrel, Inc. 28-PIN PLCC (J28-1) Rev. A MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA tel + 1 (408) 944-0800 fax + 1 (408) 474-1000 web http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2006 Micrel, Incorporated. M9999-060910 [email protected] or (408) 955-1690 4