TRIPLE 5-INPUT OR/NOR GATE Micrel, Inc. FEATURES SY100S301 SY100S301 DESCRIPTION ■ Max. propagation delay of 750ps ■ IEE min. of –25mA ■ Industry standard 100K ECL levels ■ Extended supply voltage option: VEE = –4.2V to –5.5V The SY100S301 is an ultra-fast triple 5-input OR/NOR gate designed for use in high-performance ECL systems. The inputs on this device have 75kΩ pull-down resistors. ■ Voltage and temperature compensation for improved noise immunity ■ 20% faster than Fairchild 300K at lower power ■ Internal 75kΩ input pull-down resistors ■ Function and pinout compatible with Fairchild F100K ■ Available in 28-pin PLCC package BLOCK DIAGRAM PIN NAMES Pin D1a D2a D3a D4a D5a Function Dna, Dnb, Dnc Data Inputs (n-1...5) Oa Oa, Ob, Oc Data Outputs Oa Oa, Ob, Oc Complementary Data Outputs VEES VEE Substrate VCCA VCCO for ECL Outputs D1b D2b D3b D4b D5b D1c D2c D3c D4c D5c M9999-042307 [email protected] or (408) 955-1690 Ob Ob Oc Oc Rev.: H 1 Amendment: /0 Issue Date: April 2007 SY100S301 Micrel, Inc. D1a Ordering Information Oa Oa D3a D2a VEES D4a PACKAGE/ORDERING INFORMATION Part Number Package Type Operating Range Package Marking Lead Finish Ob SY100S301JC J28-1 Commercial SY100S301JC Sn-Pb Ob VCCA SY100S301JCTR(1) J28-1 Commercial SY100S301JC Sn-Pb VCC VCC SY100S301JZ(2) J28-1 Commercial SY100S301JZ with Pb-Free bar-line indicator Matte-Sn Oc SY100S301JZTR(1, 2) J28-1 Commercial SY100S301JZ with Pb-Free bar-line indicator Matte-Sn 11 10 9 8 7 6 5 D5a D1b 12 13 VEE VEES D2b 14 15 D3b D4b 4 3 Top View PLCC J28-1 16 17 18 2 1 28 27 26 Oc 19 20 21 22 23 24 25 D3c D4c D5c D1c D2c VEES D5b Notes: 1. Tape and Reel. 2. Pb-Free package is recommended for new designs. 28-Pin PLCC (J28-1) M9999-042307 [email protected] or (408) 955-1690 2 SY100S301 Micrel, Inc. ABSOLUTE MAXIMUM RATINGS(1) LOGIC EQUATION Oa = D1a + D2a + D3a + D4a + D5a Ob = D1b + D2b + D3b + D4a + D5b Oc = D1c + D2c + D3c + D4c + D5c Symbol GUARANTEED OPERATING CONDITIONS Symbol Parameter VEE Input HIGH Current TA Power Supply Current Min. Typ. Max. Unit –5.5 –4.5 –4.2 V 0 25 85 ˚C Rating Value Unit VEE Power Supply –0.5 to +7.0 V VIN Input Voltage –0.5 to VEE V IOUT DC Output Current –50 mA TC Temperature Under Bias –55 to +125 ˚C TJ Junction Temperature +150 ˚C TLEAD Lead Temperature (soldering, 20 sec.) +260 ˚C Tstore Storage Temperature –65 to +150 ˚C Note: 1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied at conditions other than those detailed in the operational sections of this data book. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. DC ELECTRICAL CHARACTERISTICS VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND Symbol Parameter IIH Input HIGH Current IEE Power Supply Current Min. Typ. Max. Unit Condition — — 200 µA — –25 –17 –11 mA Inputs Open AC ELECTRICAL CHARACTERISTICS VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND TA = 0°C Symbol TA = +25°C TA = +85°C Parameter Min. Max. Min. Max. Min. Max. Unit tPLH tPHL Propagation Delay Data to Output 300 750 300 750 300 750 ps tTLH tTHL Transition Time 20% to 80%, 80% to 20% 300 900 300 900 300 900 ps M9999-042307 [email protected] or (408) 955-1690 3 Condition SY100S301 Micrel, Inc. TIMING DIAGRAM 0.7 ± 0.1 ns 0.7 ± 0.1 ns INPUT 80% 50% 20% TRUE tPHL tPLH 50% OUTPUT tPLH tPHL 80% 50% 20% COMPLEMENT tTLH tTHL Propagation Delay and Transition Times M9999-042307 [email protected] or (408) 955-1690 4 SY100S301 Micrel, Inc. 28-PIN PLCC (J28-1) Rev. A MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB USA http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2006 Micrel, Incorporated. M9999-042307 [email protected] or (408) 955-1690 5