OMRON 2SMPP-02

MEMS Gauge Pressure Sensor
2SMPP
MEMS Gauge Pressure Sensor Featuring
Small Size and Low Power Consumption
• Ultra-miniature 6.1 × 4.7 × 8.2 mm (L × W × H).
• Piezo Resistive element provides electrical characteristics
that are superior to capacitive type pressure sensors.
• 0 to 37 kPa pressure range.
• Low Power consumption of 0.2 mW
• Low Temperature Influence
• RoHS Compliant
Ordering Information
Standard Models with Surface mount package
Classification
Bottom Port Type
Structure
Packaging
SOP
Plastic sleeve
Terminal Arrangement
Model
2SMPP-02
Application Examples
Icc
Vout (+)
• Medical equipment
• Home appliance
• Air movement control
• Level indicators
Non Conneted
Nsub
• Leak detection
• Pressure controller
GND
Vout (−)
MEMS Gauge Pressure Sensor
2SMPP
35
Specifications
■ Ratings
Item
2SMPP-02
Pressure type
Gauge Pressure
Sensing type
Piezo Resistive
Applicable gases
Air (Non-corrosive, dust free)
Ratings
Pressure range
0 to 37 kPa
Withstand pressure
Max. 53 kPa
Supply current
100 μADC
Current consumption
Max. 130 μADC
Ambient operating temperature
0 to 50°C (with no icing or condensation)
Ambient operating humidity
15 to 90%RH (with no icing or condensation)
Ambient storage temperature
−30 to 85°C (with no icing or condensation)
Ambient storage humidity
10 to 95%RH (with no icing or condensation)
Note: 1. The above values are initial values measured at ambient temperature condition of 23°C.
2. Please avoid caustic gases.
3. Standard product is not calibrated for negative pressures.
■ Electrical Characteristics
Item
2SMPP-02
Bridge resistance
20 ± 2 kΩ
Offset voltage (See note 2.)
−2.5 ± 4.0 mV
Span voltage (See note 2.)
31.0 ± 3.1 mV (at 37 kPa)
Non-Linearity (See note 2.)
0 ± 0.8%FS (0 to 37 kPa)
Hysteresis (See note 2.)
0 ± 0.5%FS (0 to 37 kPa)
Temperature influence of Span
0.5 ± 1.0%FS (at 0°C)
Temperature influence of Offset
0 ± 3.0%FS (0 to 25°C)
0.3 ± 1.0%FS (at 50°C)
0 ± 3.0%FS (25 to 50°C)
Note: 1. The above values are initial values measured at ambient temperature condition of 23°C.
2. Not including temperature influence.
■ Environment Characteristics
Item
2SMPP-02
Vibration resistance
Shock resistance
Destruction
10 Hz to 500 Hz 10 G
Malfunction
10 Hz to 500 Hz 10 G
Destruction
15 G
Malfunction
15 G
Life Expectancy
300,000 Operations min. (0 to 39 kPa)
ESD
1000 V (Human body model)
Weight
0.17 g
Package Material
PPS (Polyphenylenesulfide)
36
2SMPP
MEMS Gauge Pressure Sensor
Engineering Data (for reference)
■ Output Characteristics
Rated Pressure vs. Output Voltage
40
35
Output Voltage [mV]
30
25
20
15
10
5
0
−5
0
Note: 1.
2.
3.
4.
10
20
30
40
Rated Pressure [kPa]
50
Ambient temperature condition: 25°C
Drive current: 100 μA
These output voltage characteristics are measured with tester without a mounting board.
The output voltage characteristics may be influenced by the mounting board. Be sure to check operation including durability in actual
equipment before use.
Temperature influence of Span voltage
Temperature influence of Offset voltage
2.0
Temp. Influence of Offset Voltage [%FS]
Temp. Influence of Span Voltage [%FS]
2.0
1.5
1.0
0.5
0.0
−0.5
−1.0
−10
Note: 1.
2.
3.
4.
0
10
20
30
40
Temperature [°C]
50
60
1.5
1.0
0.5
0.0
−0.5
−1.0
−1.5
−2.0
−10
0
10
20
30
40
Temperature [°C]
50
60
Measured points are 0°C and 25°C, 50°C
Drive current: 100 μA
These output voltage characteristics are measured with tester without a mounting board.
The output voltage characteristics may be influenced by the mounting board. Be sure to check operation including durability in actual
equipment before use.
MEMS Gauge Pressure Sensor
2SMPP
37
Pressure cycle range (0 to 40 kPa)
1
Span voltage range [%FS]
Offset voltage range [%FS]
1
0.5
0
−0.5
−1
Note: 1.
2.
3.
4.
0
100000
200000
Pressure cycle
0.5
0
−0.5
−1
300000
0
100000
200000
Pressure cycle
Tested temperature condition: 25°C
Number of pressure cycle time: 3 x 105
Rated cycle pressure: 0 to 40 kPa
These output voltage characteristics are measured with tester without a mounting board.
Example of application circuit for MEMS Pressure Sensor
VDD
Constant current circuit unit
Amplifier circuit unit
+
−
Pressure
Sensor
+
−
−
+
Vout
−
+
1. The pressure sensor is designed to convert a voltage by means of constant current drive.
2. Please amplify the output voltage of the pressure sensor by using the amplifying circuit if necessary.
38
MEMS Gauge Pressure Sensor
2SMPP
300000
Dimensions
Note: All units are in millimeters unless otherwise indicated.
2SMPP-02
4.75
4.00
3
0.25±0.05
#1
φ3.80
φ0.62
6.15 5.40
9.85
A
3.20
4-R0.50
4
6
1.27
0.40
1.27 x 2 = 2.54
1.00
2.00
The tolerance is ±0.3mm unless otherwise specified.
1.50
2.80
1.00
4.75
(1.10)
φ1.80
φ2.60
Top view
1 Vout (+)
6 Icc
2 NC
5 N-sub
3 GND
6 Vout (-)
Marking
0.75
1.125
5.45
0.10
P P 0 2
0.90
4.05
1.125
0.45
5 6 7 8
(0.90)
1.65
1.65
3.30
(1.075)
LOT NUMBER
MEMS Gauge Pressure Sensor
2SMPP
39
Precautions
■ Precautions for Correct Use
Handling
Mounting
• Only air can be used as pressure media on the products directly. It
is prohibited to use pressure media including corrosive gases (e.g.
organic solvents gases, sulfur dioxide and hydrogen sulfide gases),
fluid and any other foreign materials.
• The products are not water proof. Please keep dry in use.
• Don't use the products under dew-condensing conditions. Frozen
fluid on sensor chips may also cause fluctuation of sensor output
and other troubles.
• Don't put foreign materials (e.g. a wire or pin) into connecting tube.
It may cause breakage of pressure sensor chips or fluctuation of
sensor output caused by clogging the tube.
• Use the products within rated pressure. Usage at pressure out of
the range may cause breakage.
• Don't use under high-frequency vibration including ultrasonic wave.
• The products may be broken by static electricity. Charged materials
(e.g. a workbench and a floor) and workers must provide measures
against static electricity, including ground connection.
• Overpowering terminals may deform them and detract their solderability. Don't drop or handle the products roughly.
• Don't use the products under humid or dusty condition.
• Terminals connection of pressure sensors must be handled as
directed by a connection diagram.
• Use lands on the printed-circuit boards to which the sensor can be
securely fixed.
• Fix pin No.2 on the printed-circuit boards, not fixed causes fluctuation of sensor output signals.
Environmental Conditions for Transport and Storage
• It is prohibited to keep the products with corrosive gases (e.g.
organic solvents gases, sulfur dioxide and hydrogen sulfide gases).
• The products are not water proof. Please keep dry during storage.
• An anti-static treatment has been applied to the sleeves. Please
note the following points.
1. Getting wet may remove an anti-static treatment and eliminate its effect.
2. The sleeves may feel sticky under hot and humid condition
due to the nature of the anti-static treatment.
3. Anti-static has aging degradation. It is prohibited to keep the
sleeves for more than six months. The sleeves are also nonreusable.
• Don't keep the products under humid or dusty condition.
40
MEMS Gauge Pressure Sensor
2SMPP
Soldering
• Due to its small size, the thermal capacity of the pressure sensor is
low. Therefore, take steps to minimize the effects of external heat.
• Dip soldering bath: Max.260°C, within 10 sec.
• Soldering iron: Max. 260°C, within 10 sec.
• Do not heat the case of sensor package, heat only terminal.
• Use a non-corrosive resin type of flux. Since the pressure sensor
chip is exposed to the atmosphere, do not allow flux to enter inside.
Cleaning
• Since the pressure sensor chip is exposed to atmosphere, do not
allow cleaning fluid to enter inside.
• Avoid ultrasonic cleaning since this may cause breaks or disconnections in the wiring.
Coating
• Do not coat the pressure sensor when it is mounted to the print circuit board.
• Do not wash the print circuit board after the pressure sensor is
mounted using detergent containing silicone. Otherwise, the detergent may remain on the surface of the pressure sensor.
MEMO
MEMS Gauge Pressure Sensor
2SMPP
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X305-E-1
10/10
Specifications subject to change without notice
MEMS Gauge Pressure Sensor
2SMPP
Printed in USA