Communications Units for E3X-DA-N-series Fiber Amplifiers E3X-DRT21/SRT21/CIF11 CSM_E3X-DRT21_SRT21_CIF11_DS_E_2_1 Three New Communications Units for Fiber Amplifiers DeviceNet Communications Unit E3X-DRT21 CompoBus/S Communications Unit E3X-SRT21 RS-422 Communications Unit E3X-CIF11 Features Fibers Mobile Console RS422 Connecting a hand-held Mobile Console enables easy setting and monitoring. Optic Terminal-block Unit al Co mmun icatio ns E39-TM1 Using a Terminal-block Unit allows input from Basic Switches. Programmable Controller Reduced Wiring New connectors enable wiring and space reductions, as well as easier maintenance. Create the Required Number of Channels by Connecting Up To 16 Units (14 Units for CompoBus/S). A New Amplifier That Monitors the ON/OFF Incident Level. The peak data and bottom data are updated according to the ON/OFF timing of the Sensor. This feature enables monitoring of aging and remote setting of thresholds, even in applications with a high ON/OFF frequency. (One is updated when the Sensor turns ON, and the other when the Sensor turns OFF, depending on whether the Sensor is light-ON or dark-ON.) Incident level data Threshold value Bottom data E3X-DA6-P Wiring-reduction Connector Basic Switch E3X-CN02 Peak data 1 E3X-DRT21/SRT21/CIF11 Ordering Information Communications Units Fiber Amplifier with Incident Level Monitoring Function* Communications method DeviceNet CompoBus/S RS-422 Model E3X-DRT21 E3X-SRT21 E3X-CIF11 Communications method All communications methods Wiring-reduction Connector* Communications method --- Terminal-block Unit Communications method All communications methods Model E39-TM1 Model E3X-DA6-P Model E3X-CN02 * Order Fiber Amplifiers and Wiring-reduction Connectors as sets. Ratings and Specifications Communications Units Item Model E3X-DRT21 E3X-SRT21 E3X-CIF11 Communications method DeviceNet CompoBus/S RS-422 *2 E3X-DA6, E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8 Connectable Fiber Amplifiers *1 E3X-DA6TW, E3X-DA8TW, E3X-DA6-P, E39-TM1 Number of connectable Fiber 16 max. 14 max. 16 max. Amplifiers 11.4 to 26.4 VDC Power supply voltage 11 to 25 VDC 14 to 26.4 VDC (12 VDC −5% to 24 VDC +10%) Internal current consumption *3 70 mA max. 30 mA max. 40 mA max. Ambient temperature Operating: −20 to 55°C, Storage: −30 to 70°C (with no icing or condensation) Ambient humidity 35% to 85% (with no condensation) Weight (packed state) Approx. 150 g Approx. 200 g *1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers (e.g., E3X-DA11V). *2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number). Connection is also supported for models with “MADE IN JAPAN” on the cover underlined. Lot No.1 8 6 0 1 Manufactured on 18 June 2001. Last two digits of the year of manufacture. Month of manufacture. October, November, and December are represented with X, Y, and Z respectively. Day of manufacture. *3. Does not include the current supplied to the Fiber Amplifier. Terminal-block Unit Item Model Power supply voltage*1 Sensor power supply Current consumption Response speed Number of inputs Input signals Input operating configuration Indicators Ambient temperature*2 E39-TM1 12 to 24 VDC ±10%, ripple (p-p) 10% max. 11 to 23 VDC (power supply voltage −1 V) 40 mA max. + Sensor current consumption (total: 100 mA max.) 1.2 ms max. 1 point NPN/PNP no-voltage input (contact and non-contact), switchable N.O./ N.C., switchable Input signal display (orange) Operating: Groups of 1 to 3 Units: −25 to 55°C (with no icing or condensation) Groups of 4 to 8 Units: −25 to 45°C (with no icing or condensation) Groups of 9 to 16 Units: −25 to 40°C (with no icing or condensation) Storage: −30 to 70°C *1. The power supply for the E39TM1 is provided from the Communications Unit (order separately). Use an E3X-CN02 (order separately) Connector. *2. When 4 or more Units are grouped together, the current consumption per Unit must not exceed 75 mA. When using together with the E3X-DA-N Fiber Amplifiers, connect the E39-TM1 Units at the end of the group. In this case, the upper limit for the ambient temperature for the E3XDA-N Amplifiers is the rated upper limit −5°C. 2 E3X-DRT21/SRT21/CIF11 (Unit: mm) Dimensions Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet. Communications Units E3X-DRT21 (43) 34.6 30 16 (106) (75) 34.8 71.3 (43) (65) E3X-SRT21 30 34.6 16 34.8 71.3 E3X-CIF11 34.6 30 16 (106) (75) 71.3 34.8 (46) (65) 3 E3X-DRT21/SRT21/CIF11 Terminal-block Unit E39-TM1 3 10 3 71 64.6 40.65 In the interest of product improvement, specifications are subject to change without notice. 4 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.