OMRON E3X

Communications Units for E3X-DA-N-series Fiber Amplifiers
E3X-DRT21/SRT21/CIF11
CSM_E3X-DRT21_SRT21_CIF11_DS_E_2_1
Three New Communications
Units for Fiber Amplifiers
DeviceNet
Communications
Unit
E3X-DRT21
CompoBus/S
Communications
Unit
E3X-SRT21
RS-422
Communications
Unit
E3X-CIF11
Features
Fibers
Mobile Console
RS422
Connecting a hand-held
Mobile Console enables easy
setting and monitoring.
Optic
Terminal-block Unit
al Co
mmun
icatio
ns
E39-TM1
Using a Terminal-block Unit allows input
from Basic Switches.
Programmable Controller
Reduced Wiring
New connectors enable wiring and space reductions, as well as easier maintenance.
Create the Required Number of Channels by Connecting Up To 16 Units
(14 Units for CompoBus/S).
A New Amplifier That Monitors the ON/OFF Incident Level.
The peak data and bottom data are updated according
to the ON/OFF timing of the Sensor.
This feature enables monitoring of aging and remote
setting of thresholds, even in applications with a high
ON/OFF frequency.
(One is updated when the Sensor turns ON, and the
other when the Sensor turns OFF, depending on
whether the Sensor is light-ON or dark-ON.)
Incident level data
Threshold value
Bottom data
E3X-DA6-P
Wiring-reduction
Connector
Basic Switch
E3X-CN02
Peak data
1
E3X-DRT21/SRT21/CIF11
Ordering Information
Communications Units
Fiber Amplifier with Incident Level Monitoring Function*
Communications method
DeviceNet
CompoBus/S
RS-422
Model
E3X-DRT21
E3X-SRT21
E3X-CIF11
Communications method
All communications methods
Wiring-reduction Connector*
Communications method
---
Terminal-block Unit
Communications method
All communications methods
Model
E39-TM1
Model
E3X-DA6-P
Model
E3X-CN02
* Order Fiber Amplifiers and Wiring-reduction Connectors as sets.
Ratings and Specifications
Communications Units
Item
Model
E3X-DRT21
E3X-SRT21
E3X-CIF11
Communications method
DeviceNet
CompoBus/S
RS-422
*2 E3X-DA6, E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8
Connectable Fiber Amplifiers *1
E3X-DA6TW, E3X-DA8TW, E3X-DA6-P, E39-TM1
Number of connectable Fiber
16 max.
14 max.
16 max.
Amplifiers
11.4 to 26.4 VDC
Power supply voltage
11 to 25 VDC
14 to 26.4 VDC
(12 VDC −5% to 24 VDC +10%)
Internal current consumption *3 70 mA max.
30 mA max.
40 mA max.
Ambient temperature
Operating: −20 to 55°C, Storage: −30 to 70°C (with no icing or condensation)
Ambient humidity
35% to 85% (with no condensation)
Weight (packed state)
Approx. 150 g
Approx. 200 g
*1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers (e.g., E3X-DA11V).
*2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number).
Connection is also supported for models with “MADE IN JAPAN” on the cover underlined.
Lot No.1 8 6 0 1
Manufactured on 18 June 2001.
Last two digits of the year of manufacture.
Month of manufacture. October, November, and December are represented with X, Y, and Z respectively.
Day of manufacture.
*3. Does not include the current supplied to the Fiber Amplifier.
Terminal-block Unit
Item
Model
Power supply voltage*1
Sensor power supply
Current consumption
Response speed
Number of inputs
Input signals
Input operating configuration
Indicators
Ambient temperature*2
E39-TM1
12 to 24 VDC ±10%, ripple (p-p) 10% max.
11 to 23 VDC (power supply voltage −1 V)
40 mA max. + Sensor current consumption (total: 100 mA max.)
1.2 ms max.
1 point
NPN/PNP no-voltage input (contact and non-contact), switchable
N.O./ N.C., switchable
Input signal display (orange)
Operating:
Groups of 1 to 3 Units: −25 to 55°C (with no icing or condensation)
Groups of 4 to 8 Units: −25 to 45°C (with no icing or condensation)
Groups of 9 to 16 Units: −25 to 40°C (with no icing or condensation)
Storage: −30 to 70°C
*1. The power supply for the E39TM1 is provided from the
Communications Unit (order
separately). Use an E3X-CN02
(order separately) Connector.
*2. When 4 or more Units are grouped
together, the current consumption
per Unit must not exceed 75 mA.
When using together with the
E3X-DA-N Fiber Amplifiers,
connect the E39-TM1 Units at the
end of the group.
In this case, the upper limit for the
ambient temperature for the E3XDA-N Amplifiers is the rated upper
limit −5°C.
2
E3X-DRT21/SRT21/CIF11
(Unit: mm)
Dimensions
Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
Communications Units
E3X-DRT21
(43)
34.6
30
16
(106)
(75)
34.8
71.3
(43)
(65)
E3X-SRT21
30
34.6
16
34.8
71.3
E3X-CIF11
34.6
30
16
(106)
(75)
71.3
34.8
(46)
(65)
3
E3X-DRT21/SRT21/CIF11
Terminal-block Unit
E39-TM1
3
10
3
71
64.6
40.65
In the interest of product improvement, specifications are subject to change without notice.
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.