Motor Timer H2C DIN-sized (48 x 48, 45 x 75 mm) Motor Timer with Variable Time Ranges Five time ranges are selectable per timer unit. Easy-to-monitor neon lamp for timing operation indication (for 110, 120, 220, 240 VAC types only). Conforms to VDE0110 Group C for creepage distance. Easy-to-set large transparent knob and easy-toread single pattern scale facilitate time setting. Equipped with timing operation indicator and moving pointer. RC Ordering Information Operation/resetting p / g system t Time-limit operation/ se esett g self-resetting Internal connection ti Separate motor a d clutch c utc and connection i Terminal 8-pin round socket Time-limit contact t t SPDT Instantaneous contact t t SPDT 11-pin round socket Front screw Time-limit operation/ e ect c resetting esett g electric 8-pin round socket SPDT 11-pin round socket Surface mounting/ track mounting Flush mounting H2C-8 H2C-8 (with Y92F-30 adapter) H2C H2C (with Y92F-30 adapter) H2C-F --- --- H2C-8R H2C-8R (with Y92F-30 adapter) SPDT H2C-R H2C-R (with Y92F-30 adapter) H2C-FR --- Front screw Note: Model Specify both the model number and supply voltage when ordering. Accessories (Order Separately) Timer Back connecting socket Track mounted socket ( (see note 1) Solder terminal Screw terminal H2C-8, H2C-8R P2CF-08, PF085A PL08 P3G-08 H2C, H2C-R PF113A PL11 P3GA-11 Note: Track mounted socket can be used as a front connecting socket. 1 H2C H2C Specifications Time Ranges Five time ranges are available for each timer by turning the time range selector every 60 degrees. Note: Rated time is displayed on the window. Position of time range selector Time range code A 1.25 to 30 s 7.5 s to 3 min 1.25 to 30 min 7.5 min to 3 hrs 1.25 to 30 hrs B 0.2 to 6 s 2 to 60 s 0.2 to 6 min 2 to 60 min 0.2 to 6 hrs C 0.5 to 12 s 5 to 120 s 0.5 to 12 min 5 to 120 min 0.5 to 12 hrs Ratings Item H2C Rated supply voltage 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note 1) Operating voltage range 85% to 110% of rated supply voltage (see note 2) Power consumption Approx. 3.5 VA Control outputs 6 A at 250 VAC, resistive load (cos! = 1) (see note 3) Note: 1. The front panel of the timer is color coded to identify the following supply voltage classifications: 100 to 120 V: Blue 200 to 240 V: Red Other classes: Black 2. If the voltage continues to be applied after the set time has elapsed, the operating voltage range will change to between 90% and 110% of the rated voltage. 3. The switching capacity of the control output is 6 A at 250 VAC (cos" = 1). Refer to “Engineering Data” since the electrical service life of the built-in switch will change in such a case. Characteristics Accuracy of operating time #0.5% max. $#1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range code C) Setting error #2% max. Reset time 0.5 s max. Influence of voltage #1% max. Influence of temperature #2% max. Insulation resistance 100 M% min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts) 2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 150 m/s2 (approx. 15G) Ambient temperature Operating: --10&C to 50&C Storage: --25&C to 65&C Ambient humidity Operating: 45% to 85% Life expectancy Mechanical: 10,000,000 operations min. 500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h) Electrical: See “Engineering Data” Motor life expectancy 20,000 hrs Approved standards UL (File No. E52800) Weight H2C series: approx. 180 g H2C-F series: approx. 270 g 2 H2C H2C Switching operations (x 103 ) Switching operations (x 103 ) Engineering Data Load current (A) Load current (A) Nomenclature Timing operation indicator Time range selector Rated voltage color code Operation Timing Chart H2C-8 H2C-8R ON-delay 8-pin Round Socket Set time OFF-delay 8-pin Round Socket Rt Set time Rt Rt Set time (T) Rt Power failure time (t) Rt T+t Rt: Resetting time Rt: Resetting time H2C(-F) H2C-(F)R Set time Rt Set time Rt Set time (T) Rt Rt Power failure time (t) Rt T+t (see note) Note: Rt: Resetting time (see note) Rt: Resetting time For the types rated at 24 and 48 VAC, the timing operation indicator is not equipped. 3 H2C H2C Dimensions Note: All units are in millimeters unless otherwise indicated. H2C/H2C-R/ H2C-8/H2C-8R For Flush Mounting 44.8 x 44.8 For a load current of 3 A max., dimension L becomes 3 mm min. with an interval of 0 mm between timers. For a load current of 6 A max., dimension L becomes 8 mm min. with an interval of 5 mm between timers. H2C-F/H2C-FR Mounting Holes Mounting Height of Timer Two, M4 or 4.5 dia. holes For a load current of 1 A max., dimension L becomes 10 mm min. with an interval of 0 mm between timers. For a load current of 3 A max., dimension L becomes 15 mm min. with an interval of 5 mm between timers. For a load current of 6 A max., dimension L becomes 20 mm min. with an interval of 10 mm between timers. Accessories (Order Separately) Track Mounted/Front Connecting Socket P2CF-08 Terminal Arrangement (Top View) Eight, M3.5 x 7.5 sem Mounting Holes Mounting Height of Timer with Socket Two, 4.5 dia. or Two, M4 Two, 4.5 dia. holes Top View PF085A Terminal Arrangement (Top View) Eight, M3.5 ' 7 sems Mounting Holes Two, M4 or 4.5 dia. holes Two, 4.5 dia. holes For a load current of 3 A max., dimension L becomes 14 mm min. with an interval of 0 mm between timers. For a load current of 6 A max., dimension L becomes 19 mm min. with an interval of 5 mm between timers. 4 Mounting Height of Timer with Socket H2C H2C PF113A Terminal Arrangement (Top View) Eleven, M3.5 ' 7 sems Mounting Holes Two, M4 or 4.5 dia. holes Mounting Height of Timer with Socket For a load current of 3 A max., dimension L becomes 14 mm min. with an interval of 0 mm between timers. For a load current of 6 A max., dimension L becomes 19 mm min. with an interval of 5 mm between timers. Back Connecting Socket Terminal Arrangement (Bottom View) PL08 (Solder Terminals) Mounting Holes Mounting Height of Timer with Socket Two, 3.5 dia. or 3M socket mounting holes Two, 2 dia. holes Bottom View PL11 (Solder Terminals) Terminal Arrangement (Bottom View) Mounting Holes Two, 3.5 dia. or M3 socket mounting holes Mounting Height of Timer with Socket Two, 2 dia. holes 35 max. Approx. 20.5 Mounting Height of Timer with Socket P3G-08 Terminal Arrangement (Bottom View) P3GA-11 27 dia. Terminal Arrangement (Bottom View) 5 H2C H2C Mounting Track (Meets DIN EN50022) PFP-100N2 PFP-100N/PFP-50N Twelve, 25 ' 4.5 elliptic holes (see note) (see note) Note: This dimension applied to PFP-50N. Note: End Plate PFP-M PFP-S H2C (with PF113A) H2C-F (See note) (See note) Note: A total of twelve, 25 x 4.5 elliptic holes are provided with 6 holes cut from each rail end at a pitch of 10 mm between holes. For a load current of 3 A max., a spacer and an end plate are not required. For a load current of 6 A, one spacer or an end plate is required. Note: For a load current of 1 A max., a spacer and an end plate are not required. For a load current of 3 A max., one spacer or an end plate is required. For a load current of 6 A max. two spacers or two end plates are required. Adapter for Flush Mounting Timer Hold-down Clips Y92F-30 Y92H-2 (for PF085A/PF113A Connecting Socket) (See note) Note: 6 The adapter can be mounted to the timer form any side of the timer housing since the adapter security notches are provided on all four sides of the housing. Y92H-1 (for PL08/PL11 Connecting Socket) H2C H2C Time Setting Ring Protective Cover Y92A-Y1 Y92A-48B The time setting ring locks the time setting knob to store the set time to facilitate its resetting. A maximum of two time setting rings are connectable per timer. The protective cover shields the front panel, particularly the time setting section, from dust, dirt, and water, as well as prevents the set value from being altered due to accidental contact with the time setting knob. Installation Terminal Arrangement H2C-8 H2C-8R ON-delay 8-pin Round Socket OFF-delay 8-pin Round Socket H2C(-F) H2C-(F)R 7 H2C H2C Precautions How to Change the Time Range How to Mount the Timer on Mounting Track Change the positions of the time range selector with a flat-blade screwdriver or an Allen wrench. Mounting First hook portion A of the timer to the mounting track, then depress the timer in direction B. ! Caution Be sure to turn the power off before changing the time specification. Changing the time range while the timer is in operation may cause a malfunction. Dismounting Pull out portion C with a round-blade screwdriver and remove the timer from the mounting track. A C B Electrical Set How to Select Power Frequency ! Notice Power frequency Before using the timer, set the frequency selector located at the rear panel to the proper power frequency (50 or 60 Hz). Note that if the frequency selector is set incorrectly, time measurement may not be performed accurately against the set time. The motor and clutch do not need to be reset simultaneously. Use the voltage applied to the clutch for resetting with the H2C-R. Do not allow power to be continuously applied to the motor and clutch for extended periods of time. Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. The deviation and setting error for the operation time shows the percent of FS. The absolute value of the deviation and setting error will not change even if the set time is changed. The time specifications should therefore be selected to use the operation time as close to FS as possible. At high temperatures, the operation voltage will be 90% or less if voltage is applied continuously after timeout. Be sure to keep the voltage within the allowable voltage fluctuation range. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L007-E1-8 8