Multifunction Preset Counter H7CX Counters • Highly visible display with backlit negative transmissive LCD. • Programmable PV color to visually alert when output status changes (screw terminal block models). • Intuitive setting enabled using ergonomic up/down digit keys (4digit models) and DIP switch. • Configurable as 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachometer. (Configurability varies with model.) • PNP/NPN switchable input. • Finger-safe terminals (screw terminal block models). • Meets a variety of mounting requirements: Screw terminal block models, and pin-style terminal models. • NEMA4/IP66 compliance. • Six-language instruction manual. Contents Model Number Structure.............................................................. C-88 Ordering Information.................................................................... C-88 Specifications............................................................................... C-89 Connections................................................................................. C-93 Nomenclature .............................................................................. C-98 Dimensions .................................................................................. C-99 Precautions.................................................................................. C-103 Operating Procedures.................................................................. C-106 Setting Procedure Guide ....................................................... C-106 Operating Procedures (Counter Function) ............................ C-107 Operating Procedures (Tachometer Function) ...................... C-118 Operation in Configuration Selection Mode........................... C-124 Additional Information .................................................................. C-125 Multifunction Preset Counter H7CX C-87 Model Number Structure ■ Model Number Legend H7CX-A@@@@@@ 1 2 3 4 5 6 4. Output type None: Contact output or contact and transistor in combination S: Transistor output 5. Supply voltage/external power supply None: 100 to 240 VAC at 50/60 Hz with 12 VDC power supply D: 12 to 24 VDC without external power supply D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC power supply 6. Case color None: Black G: Light gray (Munsell 5Y7/1): Produced upon request. 1. External connection None: Screw terminals 11: 11-pin socket 2. No. of digits None: 6 digits 4: 4 digits 3. Stage setting None: 1-stage setting U: Factory-set to 1-stage setting W: Factory-set to 2-stage setting Ordering Information ■ List of Models Supported configurations Sensor power supply 12 VDC None Output type • 1-stage counter • 1-stage counter with total counter Supply voltage • 1-stage counter • 2-stage counter • 1-stage counter with total counter • 1-stage counter with batch counter • Dual counter (addition/subtraction) • Tachometer 11-pin socket Screw terminal 1-stage Contact output 1-stage (See note.) 2-stage 6 digits 4 digits 6 digits 4 digits 6 digits 6 digits 4 digits H7CX-A11@ H7CX-A114@ H7CX-A@ H7CX-A4@ H7CX-AU@ H7CX-AW@ H7CX-A4W@ 100 to 240 VAC H7CX-A11 H7CX-A114 H7CX-A H7CX-A4 --- H7CX-AW H7CX-A4W 12 to 24 VDC/ 24 VAC H7CX-A11D1 H7CX-A114D1 --- --- --- H7CX-AWD1 --- Contact and transistor output 100 to 240 VAC --- --- --- --- H7CX-AU --- --- 12 to 24 VDC/ 24 VAC --- --- --- --- H7CX-AUD1 --- --- Transistor output 100 to 240 VAC H7CX-A11S H7CX-A114S H7CX-AS H7CX-A4S --- H7CX-AWS --- 12 to 24 VDC/ 24 VAC H7CX-A11SD1 --- --- --- H7CX-AUSD1 H7CX-AWSD1 --- 12 to 24 VDC --- --- H7CX-AD H7CX-A4D --- --- --- --- --- H7CX-ASD H7CX-A4SD --- H7CX-AWSD H7CX-A4WSD Contact output Transistor output Note: Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2. ■ Accessories (Order Separately) Name Flush Mounting Adapter (See note 1.) Waterproof Packing (See note 1.) Models Y92F-30 Y92S-29 Track Mounting/Front Connecting Socket 11-pin 11-pin, finger-safe type P2CF-11-E Back Connecting Socket 11-pin P3GA-11 11-pin, finger-safe type Hard Cover Mounting Track P2CF-11 P3GA-11 with Y92A-48G (See note 2.) Y92A-48 Soft Cover Y92A-48F1 50 cm (l) × 7.3 mm (t) PFP-50N 1 m (l) × 7.3 mm (t) PFP-100N 1 m (l) × 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Note: 1. Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@ models). 2. Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket. C-88 • 1-stage counter • 2-stage counter • 1-stage counter with total counter • 1-stage counter with batch counter • Dual counter (addition only) Multifunction Preset Counter H7CX Specifications ■ Ratings H7CX-A4@ H7CX-A@ Preset counter Supported configurations 1-stage counter, 1-stage counter with total counter (selectable) Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz), 12 to 24 VDC H7CX-A114@ H7CX-A11@ Counters Item Classification 100 to 240 VAC (50/60 Hz) 24 VAC (50/60 Hz)/12 to 24 VDC Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC) Power consumption Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC Mounting method Flush mounting Flush mounting, surface mounting, or DIN track mounting External connections Screw terminals 11-pin socket Terminal screw tightening torque 0.5 N·m max. --- Display 7-segment, negative transmissive LCD; PV 11.5-mm-high characters, red or 9-mm-high characters, red or green (programmable) green (programmable) SV 6-mm-high characters, green 6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 11.5-mm-high characters, red 9-mm-high characters, red 4 digits (−999 to 9,999) SV range: 0 to 9,999 6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 Digits 4 digits (−999 to 9,999) SV range: 0 to 9,999 Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 Input modes Increment, decrement, command, individual, and quadrature Input signals CP1, CP2, reset, and total reset Input method No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation) Output modes N, F, C, R, K-1, P, Q, A One-shot output time 0.01 to 99.99 s Output type Contact type: SPDT Transistor type: 1 transistor Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max. N, F, C, R, K-1, P, Q, A, K-2, D, L N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A, K-2, D, L NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for details. Key protection Yes Prescaling function Yes (0.001 to 9.999) Decimal point adjustment Yes (rightmost 3 digits) Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Ambient temperature Operating: Storage: Ambient humidity 25% to 85% Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request) Attachments Waterproof packing, flush mounting adapter Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999) −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) −25 to 65°C (with no icing or condensation) None Note: 1. Permissible ripple: 20% (p-p) max. 2. Only when the following modes are selected. Input mode: command, individual, or quadrature; output mode: K-2, D, or L Multifunction Preset Counter H7CX C-89 ■ Ratings (contd.) Item H7CX-A4W@ H7CX-AW@ H7CX-AU@ Classification Preset counter Supported configurations 1-stage counter, 2-stage counter, 1-stage 1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch counter with total counter, 1-stage counter counter, dual counter (addition/subtraction), tachometer (selectable) with batch counter, dual counter (addition only) (selectable) Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz), 12 to 24 VDC Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC) Power consumption Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC Mounting method Flush mounting External connections Screw terminals Terminal screw tightening torque 0.5 N·m max. Display 7-segment, negative transmissive LCD PV 11.5-mm-high characters, red or green (programmable) SV 6-mm-high characters, green Preset counter/tachometer 100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC, 12 to 24 VDC 9-mm-high characters, red or green (programmable) Digits 4 digits (−999 to 9,999) SV range: 0 to 9,999 Input signals CP1, CP2, reset 1, and reset 2 Input method No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) Counter Tachometer 100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC 6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 Input mode Increment, decrement, command, individual, and quadrature Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation) Output modes N, F, C, R, K-1, P, Q, A One-shot output time 0.01 to 99.99 s Pulse measurement method --- Max. counting speed --- 30 Hz or 10 kHz (selectable) Measuring ranges --- 30 Hz: 0.01 to 30.00 Hz 10 kHz: 0.01 Hz to 10 kHz N, F, C, R, K-1, P, Q, A, K-2, D, L, H Periodic measurement (Sampling period: 200 ms) Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C) Output modes --- HI-LO, AREA, HI-HI, LO-LO Auto-zero time --- 0.1 to 99.9 s Startup time --- 0.0 to 99.9 s Average processing --- OFF/2/4/8 times Output type H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1) H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max. H7CX-AU/-AUD1: SPDT and 1 transistor H7CX-AUSD1: 2 transistors (Output allocation possible) NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC External power supply 12 VDC (±10%) 100 mA (except for H7CX-A@D models) Refer to Precautions for details. Key protection Yes Prescaling function Yes (0.001 to 9.999) Decimal point adjustment Yes (rightmost 3 digits) Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Ambient temperature Operating: Storage: Ambient humidity 25% to 85% Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request) Attachments Waterproof packing, flush mounting adapt- Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings er Yes (0.001 to 99.999) −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) −25 to 65°C (with no icing or condensation) Note: 1. Permissible ripple: 20% (p-p) max. 2. Only when the following modes are selected. - Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H - Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation C-90 Multifunction Preset Counter H7CX ■ Characteristics H7CX 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/ 12 to 24 VDC) 1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-@SD/-@SD1) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC Noise immunity ±1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC ±600 V (between input terminals) Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Destruction: 15 kV Malfunction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Shock resistance Destruction: 294 m/s2 each in three directions Malfunction: 98 m/s2 each in three directions Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) See Life-test Curve on page 92. Approved safety standards (See note 1.) UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection). EMC (EMI) Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: Degree of protection Panel surface: IP66 and NEMA Type 4 (indoors) (See note 2.) Weight Approx. 140 g EN61326 EN55011 Group 1 class A EN55011 Group 1 class A EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 1 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage) Note: 1. To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements. 2. A waterproof packing is necessary to ensure IP66 waterproofing between the H7CX and installation panel. Multifunction Preset Counter H7CX C-91 Counters item Insulation resistance ■ Life-test Curve (Reference Values) Resistive Load Inductive Load 1,000 No. of operations (×103) No. of operations (×103) 1,000 700 500 300 30 VDC (cosφ=1) 250 VAC (cosφ=1) 700 500 300 30 VDC (L/R=7 ms) 100 100 70 70 250 VAC cosφ=0.4 50 50 0 1 2 3 0 4 1 2 Load current (A) 3 4 Load current (A) Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). ■ Inrush Current (Reference Values) Model H7CX-A11/-AW Voltage Applied voltage Inrush current (peak value) 0.7 ms H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC 10.4 A 1.2 ms H7CX-AD 6.0 A 1.2 ms 12 to 24 VDC 264 VAC Time 5.8 A C-92 100 to 240 VAC 26.4 VDC Multifunction Preset Counter H7CX Connections ■ Block Diagram (Basic insulation) Output circuit (Basic insulation) Power supply circuit Counters (See note.) Display circuit Internal control circuit Input circuit Key switch circuit Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation. ■ I/O Functions Using as a Counter Inputs Outputs CP1, CP2 • In general (except for dual counter mode) Reads counting signals Increment, decrement, command, individual, and quadrature inputs accepted. • When used as a dual counter Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input. Increment signals can be input. Reset or Reset 1 • In general (except for dual counter mode) Resets present value and outputs (OUT2 when using the batch counter). (See note 1.) Counting cannot be performed during reset/reset 1 input. The reset indicator is lit during reset input. • When used as a dual counter Resets the CP1 present value (to 0). Counting for CP1 input cannot be performed during reset 1 input. The reset indicator is lit during reset 1 input. Total Reset or Reset 2 (See note 2.) • When used as a 1-stage/2-stage counter Does not operate (Not used). • When used as a total and preset counter Resets the total count value. Holds the total count value at 0 during total reset input. • When used as a batch counter Resets the batch count value and batch output (OUT1). Holds the batch count value at 0 during reset 2 input. • When used as a dual counter Resets the CP2 present value. Counting for CP2 input cannot be performed during reset 2 input. OUT1, OUT2 Outputs take place according to designated output mode when corresponding preset is reached. Note: 1. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models. 2. The reset indicator will not be lit when the total reset or reset 2 input is ON. Using as a Tachometer Inputs Outputs CP1, CP2 Reads counting signals. (CP2 input is not used.) Reset 1, Reset 2 Holds the measurement value and outputs. (Reset 2 input is not used.) The reset indicator is lit during hold. OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached. Multifunction Preset Counter H7CX C-93 ■ Terminal Arrangement Confirm that the power supply meets specifications before use. CP1 6 Total reset 10 CP2 CP1 Total reset CP2 Reset 0V Reset H7CX-AD/-A4D 1-stage Contact Output H7CX-A/-A4 1-stage Contact Output 7 8 9 10 0V 6 (−) 7 8 9 Sensor, etc. Unused (+) 12 VDC 11 Unused 12 Unused 13 11 5 1 Unused Unused 12 13 External power supply 1 2 3 4 2 3 4 5 OUT OUT (−) (+) Note: Terminals 1 and 6 are connected internally. Total reset 6 CP1 10 CP2 0V Reset CP1 H7CX-ASD/-A4SD 1-stage Transistor Output Total reset CP2 Reset H7CX-AS/-A4S 1-stage Transistor Output 7 8 9 10 0V 6 (−) 7 8 9 Sensor, etc. Unused (+) 12 VDC 11 Unused 12 Unused 13 11 5 1 Unused Unused 12 13 External power supply 1 2 3 4 2 3 4 OUT 5 OUT (+) (−) Note: Terminals 1 and 6 are connected internally. H7CX-A11/-A114/-A11D1/-A114D1 1-stage Contact Output H7CX-A11S/-A114S/-A11SD1 1-stage Transistor Output Reset Reset CP1 CP1 Internal circuit CP2 0V (−) (+) 4 8 9 10 1 11 4 0V (−) (+) 8 3 2 Sensor, etc. 12 VDC 1 11 9 10 12 VDC External power supply External power supply OUT OUT (−) (+) Note: Do not connect unused terminals as relay terminals. C-94 Internal circuit 5 6 7 Total reset 3 2 Sensor, etc. CP2 5 6 7 Total reset Multifunction Preset Counter H7CX (−) (+) 10 6 (−) 8 9 10 Sensor, etc. Sensor, etc. (+) (+) 12 VDC External power supply 7 0V 11 12 13 Counters (−) Reset 2 9 CP1 8 CP2 CP1 Reset 2 7 0V 6 Reset 1 CP2 H7CX-AWS/-AWSD1 2-stage Transistor Output Reset 1 H7CX-AW/-A4W/-AWD1 2-stage Contact Output 12 VDC 11 OUT1 12 13 OUT1 External power supply 1 2 3 4 1 5 2 3 5 (−) (+) 9 10 Reset 2 8 CP1 CP1 Reset 2 7 CP2 CP2 H7CX-AUSD1 1 or 2-stage Transistor Output Reset 1 H7CX-AWSD/-A4WSD 2-stage Transistor Output (+) Reset 1 (−) 4 OUT2 OUT2 7 8 9 10 0V 0V 6 6 (−) Sensor, etc. Unused (+) 11 12 13 12 VDC 11 OUT1 12 13 OUT1 or 2 External power supply 1 2 3 4 5 1 2 3 (−) 4 5 OUT 1 or 2 OUT2 (+) Note: 1. Terminals 1 and 6 are connected internally. 2. Do not connect unused terminals as relay terminals. (−) (+) Note: Each output can be flexibly allocated to either stage 1 or 2 in function selection mode. Reset 1 CP2 CP1 Reset 2 H7CX-AU/-AUD1 1-stage Contact, 1-stage Transistor Output 7 8 9 10 0V 6 (−) Sensor, etc. (+) 12 VDC External power supply 11 1 12 2 3 13 4 OUT1 or 2 5 OUT 1 or 2 (−) (+) Note: Each output can be flexibly allocated to either stage 1 or 2 by setting in function selection mode. Multifunction Preset Counter H7CX C-95 ■ Input Circuits CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input +14 V 1 kΩ Internal circuit IN Note: The circuit shown above is for no-voltage input (NPN input). ■ Input Connections The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output H7CX-A@ H7CX-A11@ 6 7 8 9 10 3 7 5 6 4 H7CX-A@ H7CX-A11@ 6 7 8 9 10 3 7 5 6 4 Operates when the transistor turns ON. Operates when the transistor turns ON. No-voltage Input Signal Levels No-contact input Short-circuit level Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 KΩ max. (The leakage current is 5 to 20 mA when the impedance is 0 Ω.) Open level Transistor OFF Impedance when OFF: 100 KΩ min. Contact input Use contact which can adequately switch 5 mA at 10 V. Maximum applicable voltage: 30 VDC max. Total reset/reset 2 input DC Two-wire Sensor CP1 input CP2 input Input Reset/reset 1 input 0V H7CX-A@ H7CX-A11@ 6 7 8 9 10 3 7 5 6 4 Operates when the transistor turns ON. Applicable Two-wire Sensor Leakage current:1.5 mA max. Switching capacity:5 mA min. Residual voltage:3 VDC max. Operating voltage:10 VDC C-96 Multifunction Preset Counter H7CX H7CX-A@ H7CX-A11@ Total reset/reset 2 input CP1 input CP2 input Reset/reset 1 input 0V Input CP1 input CP2 input Reset/reset 1 input 0V Input CP1 input CP2 input Input Reset/reset 1 input 0V Total reset/reset 2 input Sensor Total reset/reset 2 input PLC or sensor Contact Input 6 7 8 9 10 3 7 5 6 4 Operates when the contact turns ON. Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) 6 7 8 9 10 3 7 5 6 4 H7CX-A@ H7CX-A11@ 6 7 8 9 10 3 7 5 6 4 Operates when the transistor turns ON. Operates when the transistor turns OFF. H7CX-A@ H7CX-A11@ 6 7 8 9 10 3 7 5 6 4 Counters Total reset/reset 2 input CP1 input CP2 input Reset/reset 1 input 0V Input CP1 input CP2 input Reset/reset 1 input 0V Input CP1 input CP2 input Input Reset/reset 1 input 0V Total reset/reset 2 input Sensor Total reset/reset 2 input Sensor H7CX-A@ H7CX-A11@ Contact Input No-contact Input (PNP Transistor) Operates when the contact turns ON. Voltage Input Signal Levels High level (Input ON): Low level (Input OFF): Maximum applicable voltage: Input resistance: 4.5 to 30 VDC 0 to 2 VDC 30 VDC max. Approx. 4.7 kΩ Multifunction Preset Counter H7CX C-97 Nomenclature Indicators A Reset Indicator (Orange) Lit when the reset input (1) or reset key is ON. B Key Protection Indicator (Orange) C Control Output Indicator (Orange) OUT: One stage OUT1, OUT2: Two stages D Total Count Indicator Lit when the total count value is displayed. E Batch Indicator Lit when the batch count value is displayed. F Set Value 1, 2 Stage Indicator G Present Value (Main Display) Character height: 11.5 mm (6-digit: 9mm) H Set Value (Sub-display) Character height: 6 mm Operation Keys 1 2 7 3 4 5 6 9 11 10 12 8 Front view of 4-digit model I Mode Key Used to switch mode and setting items. J Reset Key The operation of the reset function depends on the configuration selected as shown in the table below. K Up Keys: 1 to 4 (6-digit models: 1 to 6) L Down Keys: 1 to 4 Switches M Key Protect Switch 1 (Factory setting) OFF 2 7 3 4 5 6 8 ON N DIP Switch 9 11 10 Front view of 6-digit model 13 14 Reset Operation by Reset Key Configuration 1-stage/2-stage counter Reset operation Resets the present value and outputs. Total and preset • Resets the present value and outputs. counter • When the total count value is displayed, resets the present value, the total count value, and outputs. C-98 Multifunction Preset Counter H7CX Batch counter • Resets the present value and OUT2. • When the batch count value is displayed, resets the present value, the batch count value, and outputs. Dual counter Resets the CP1 present value, CP2 present value, dual count value, and outputs. Tachometer Maintains the measured value and outputs (hold function). Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Counter (without Flush Mounting Adapter) Screw-terminal Models with External Power Supplies (Flush Mounting) • H7CX-AW • H7CX-AWS • H7CX-A4W • H7CX-AWD1 • H7CX-AWSD1 • H7CX-AU • H7CX-AUD1 • H7CX-AUSD1 Counters • H7CX-A • H7CX-AS • H7CX-A4 • H7CX-A4S 48×48 6 100 44.8×44.8 Note: M3.5 terminal screw (effective length: 6 mm) Screw-terminal Models without External Power Supplies (Flush Mounting) • H7CX-AD • H7CX-ASD • H7CX-A4D • H7CX-A4SD • H7CX-AWSD • H7CX-AWSD 48×48 6 64 44.8×44.8 Note: M3.5 terminal screw (effective length: 6 mm) 11-pin Socket Models (Flush Mounting/Surface Mounting) • H7CX-A11 • H7CX-A11S • H7CX-A11D1 • H7CX-A11SD1 • H7CX-A114 • H7CX-A114S • H7CX-A114D1 48×48 6 72.5 14.4 44.8×44.8 Multifunction Preset Counter H7CX C-99 ■ Dimensions with Flush Mounting Adapter Screw-terminal Models with External Power Supplies Panel Cutouts (Provided with Adapter and Waterproof Packing) • H7CX-AW • H7CX-AWS • H7CX-A4W • H7CX-AWD1 • H7CX-AWSD1 • H7CX-A • H7CX-AS • H7CX-A4 • H7CX-A4S • H7CX-AU • H7CX-AUD1 • H7CX-AUSD1 Panel cutouts are as shown below. (according to DIN43700). Y92S-29 (provided) Waterproof Packing Panel 60 min. Y92F-30 (provided) Flush Mounting Adapter 45+0.6 −0 45+0.6 −0 60 min. 15 min. (51) 58 48 7.5 98.5 Screw-terminal Models without External Power Supplies (Provided with Adapter and Waterproof Packing) • H7CX-AD • H7CX-ASD • H7CX-A4D • H7CX-A4SD • H7CX-AWSD • H7CX-A4WSD Y92S-29 (provided) Waterproof Packing 58 Panel Y92F-30 (provided) Flush Mounting Adapter Note: 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operability, it is recommended that Adapters are mounted so that the gap between sides with hooks is at least 15 mm (i.e., so that the panel cutout interval is at least 60 mm). 3. It is possible to mount counters side by side, but only in the direction without the hooks. If they are mounted side-by-side, water-resistant specifications cannot be ensured. (51) n side by side mounting A 48 7.5 A = (48n − 2.5)+10 62.5 11-pin Socket Models With Y92A-48F1 attached. A = {48n−2.5 + (n−1) x 4}+10 (Adapter and Waterproof Packing Ordered Separately) • H7CX-A11 • H7CX-A11S • H7CX-A11D1 • H7CX-A11SD1 • H7CX-A114 • H7CX-A114S • H7CX-A114D1 With Y92A-48 attached. A = (51n−5.5)+10 Y92S-29 (order separately) Waterproof Packing 58 Panel Y92F-30 (order separately) Flush Mounting Adapter P3GA-11 (order separately) Back Connecting Socket (51) 48 7.5 98.7 ■ Dimensions with Front Connecting Socket H7CX -A11@ 109.7 112 P2CF-11 Note: These dimensions vary with the kind of DIN track (reference value). C-100 Multifunction Preset Counter H7CX ■ Accessories (Order Separately) Note: All units are in millimeters unless otherwise indicated. 7.8 M3.5 x 7.5 sems 3 4.5 70 max. Terminal Arrangement/ Internal Connections (Top View) 35.4 Two, 4.5-dia. holes Counters Track Mounting/Front Connecting Socket P2CF-11 Eleven, Surface Mounting Holes Two, 4.5 dia. or two, M4 4 50 max. 31.2 max. 40±0.2 Note: Track mounting is also possible. P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 4.5 5 7.8 3 1.2 70 max. 35.4 Two, 4.5-dia. holes 4 40±0.2 50 max. 30 31.2 max. Back Connecting Socket P3GA-11 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 25.6 45 4.5 6.2 16.3 Note: Finger protection can be ensured by using in combination with the Y92A-48G Terminal Cover. Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3GA-11 Socket) Twelve, 6.4-dia. holes 34 47.7 x 47.7 16.5 48 x 48 24.6 27.6 47.4 Multifunction Preset Counter H7CX C-101 Hard Cover Y92A-48 Note: 1. Depending on the operating environment, the condition of the Soft Cover may deteriorate, and it may shrink or become harder. Therefore, it is recommended that the Soft Cover is replaced regularly. 2. The H7CX’s panel surface is water-resistive (conforming to IP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator’s hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Soft Cover Y92A-48F1 Flush Mounting Adapter (provided with screw-terminal models) Waterproof Packing (provided with screw-terminal models) Y92F-30 Y92S-29 Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 15 25 25 10 35±0.3 27±0.15 35±0.3 25 * 25 1,000 (500) 10 (see note) 15 1 25 25 15 25 25 10 1,000 27 24 1 10 Note: The values shown in parentheses are for the PFP-50N. End Plate PFP-M Spacer PFP-S 10 6.2 16 12 5 1.8 1 50 1.8 11.5 C-102 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 Multifunction Preset Counter H7CX 16.5 29.2 1.5 Precautions ■ Transistor Output The service life of the output relays depends on the switching capacity and switching conditions. Consider the actual application conditions and use the product within the rated load and electrical service life. Using the product beyond its service life may result in contact deposition or burning. The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN output Do not disassemble, repair, or modify the product. Doing so may result in electric shock, fire, or malfunction. Do not allow metal objects or conductive wires to enter the product. Doing so may result in electric shock, fire, or malfunction. Load Load + + Power for load Power for load The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H7CX. ■ External Power Supply The capacity of the external power supply is 100 mA at 12 V. When using a 24 VAC/12 to 24 VDC power supply, reduce the load with the power supply voltage, as shown in the following diagram (DC power supplies only). (DC v ltage PNP output Counters !Caution Do not