FEATURES PETERMANN TECHNIK - HIGH RELIABILITY FOR LOW COST - WIDE FREQUENCY RANGE - SMD PACKAGES WITH SMALL DIMENSIONS AND LOW PROFILE - EXCELLENT ATTENUATION BEHAVIOUR Time & Frequency Components ONE - PORT & TWO - PORT SAW RESONATORS TYPE ∆ f0* (MHz) ∆ f0 (kHz) Insertion Loss (dB) <2.5 for One-Port 433.02 SR433 +-75 / +-100 <7.5 for Two-Port <2.5 for One-Port +-75 / +-100 418.00 SR418 <7.5 for Two-Port <2.5 for One-Port SR318 318.00 +-75 / +-100 <7.5 for Two-Port <2.5 for One-Port SR315 315.00 +-75 / +-100 <7.5 for Two-Port * The nominal center frequency (f0) range is from 200 MHz to 1 GHz Other parameters and packages are available on request PACKAGE Freq.-Temp.-Coeff. T0-39 / F-11 / 5x5 SMD 0.032 ppm/°C² T0-39 / F-11 / 5x5 SMD 0.032 ppm/°C² T0-39 / F-11 / 5x5 SMD 0.032 ppm/°C² T0-39 / F-11 / 5x5 SMD 0.032 ppm/°C² Insertion Loss (dB) Package SAW-FILTER FOR REMOTE CONTROL TYPE Center Frequency (MHz) dB MHz SF314 314.0 3 f0 +-0.35 2.5 T0-39 / F-11 SF315 315.0 3 f0 +-0.35 2.5 T0-39 / F-11 SF418 418.0 3 f0 +-0.35 2.5 T0-39 / F-11 SF433 433.92 3 f0 +-0.35 2.5 T0-39 / F-11 Insertion Loss (dB) Package Band Width Other parameters and packages are available on request SAW-FILTER FOR COMMUNICATION TYPE Center Frequency (MHz) dB MHz D150RFQ 138 ~ 174 3 f0 +-0.05 <5 F-11 D280RFQ 278 ~ 284 3 f0 +-0.05 <5 F-11 D150TFN 138 ~ 174 3 f0 +-4.0 <6.5 F-11 D280TFN 178 ~ 284 3 f0 +-3.3 <4.5 F-11 D450TFN 400 ~ 500 3 f0 +-4.0 <4.5 F-11 Band Width Other parameters and packages are available on request Other Typical D1106(110.592MHz), D304TFN(304 MHz), D325TFN(325 MHz), D388(388MHz), D930(930.5MHz) Types D450 (402/406/410/414/418/422/426/430/430/434/438/442/446/450/454/458/462/466/470/474/478/482/486/ 490/492/494/498/502/506/510/514/518 MHz) PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] PETERMANN TECHNIK Time & Frequency Components SAW-FILTER FOR CORDLESS PHONE & COMMUNICATION Band Width TYPE Center Frequency (MHz) dB MHz D45 45.36 3 D48 48.36 D45/48 Insertion Loss (dB) Package f0 +1 <5 SF-712 3 f0 +1 <5 SF-712 45.36/48.36 3 f0 +1 <5 SF-915 D903 903.75 3 f0 +-2 <5 F-11 D927 927.75 3 f0 +-2 <5 F-11 D886 886.0 3 f0 +-2 <4 F-11 D931 931.0 3 f0 +-2 <4 F-11 D914 914.0 3 f0 +-2 <4 F-11 D959 959.0 3 f0 +-2 <4 F-11 Insertion Loss (dB) Package <21 TO-39 WSWR max. Package Application Other parameters and packages are available on request SAW-FILTER FOR SATELLITE-RECEIVER TYPE Center Frequency (MHz) dB MHz D479.5B 479.5 3 f0 +13.5 Band Width Other parameters and packages are available on request SAW-FILTER FOR CELLULAR PHONE / RF-STAGE SERIES TYPE Center Frequency (MHz) D902 902.5 25 MHz 3.5 dB 2.5 3 x 3 mm SMD FOR GSM D947 947.5 25 MHz 3.5 dB 2.5 3 x 3 mm SMD FOR GSM D942 942.5 35 MHz 3.5 dB 2.5 3 x 3 mm SMD FOR PDC/EGSM D836 836.5 25 MHz 3.5 dB 2.5 3 x 3 mm SMD FOR CDMA/AMPS Pass-Band Width Insertion Loss max. Other parameters and packages are available on request PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] PETERMANN TECHNIK Time & Frequency Components SAW-FILTER FOR CELLULAR PHONE / IF-STAGE SERIES TYPE Center Frequency (MHz) D881 881.5 25 MHz D246 246.0 D400 D85 WSWR max. Package Application 3.5 dB 2.5 3 x 3 mm SMD FOR CDMA/AMPS +-80 MHz 8 dB 2.0 µs 5 x 5 mm SMD FOR GSM 400.0 +-83 MHz 6 dB 1.0 µs 5 x 5 mm SMD FOR GSM 85.38 +-300 MHz 15 dB 3.0 µs 7 x 5 mm SMD FOR CDMA Pass-Band Width Insertion Loss max. Other parameters and packages are available on request PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] PETERMANN TECHNIK Time & Frequency Components PACKAGE DRAWINGS TO-39 5 x 5 mm SMD 09.5max 3.5max 5.0 +- 0.2 5.0min 00.45 05.08 0. 75 0. 8 #3 1.0+0.1 - 5.0 +- 0.2 FUNCTION INPUT GROUND OUTPUT PIN #1 #2 #3 #1 1.5max #2 Unit:mm 0.6+0.1 1.20+0.15 - 1.27+0.1 - F-11 3.3max #1 #3 #2 #8 #2 #1 #4 #3 11.3max #4 4.8max #2 #4 #7 2.54+0.1 - 2.54 2.54 2.54 #1 #6 #3 5.0min 00.5 #5 2.08+0.15 - PIN #1 #2 #3 #4 FUNCTION INPUT GROUND GROUND OUTPUT PIN #1 #2 #3 #4 #5 #6 #7 #8 CONNECTION GROUND INPUT GROUND GROUND / CASE GROUND OUTPUT GROUND GROUND / CASE Unit:mm PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] Unit: mm PETERMANN TECHNIK Time & Frequency Components SF-915 SIP5L 16.0max 9.5max 5.0 4.0 16.0max 4-2.54 12.0 #1 #2 #3 #4 #5 00.5 2.75 4.0 Unit:mm T-4 #1 #2 #3 #4 #5 5.5max 4.0 0.3 15.6max 4-2.54 4.5 0.54 Unit:mm #1 #2 #3 #4 00.65 1.6 7.6 1.6 S-6BA 16.0max 2.5 3.5 3.5max 6.0 Unit:mm #1 #2 #3 #4 #5 00.5 4-2.54 1.7 Unit:mm PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] PETERMANN TECHNIK Time & Frequency Components 3 x 3 mm SMD TO-8 0.85+0.08 - 3.0 +- 0.13 5.0 6.0 3.0 +- 0.13 015.6max 1.5max 5-00.5 0.6 #6 #5 #3 #4 CONNECTION GROUND INPUT GROUND GROUND OUTPUT GROUND 1.40 Unit: mm 6.25 #1 #2 1.40 0.6 3.75 3.75 PIN #1 #2 #3 #4 #5 #6 TO-5 Unit:mm 5.0 DIP10K 12.7 11.5 4.0 5.2 18.5max 0.50 0.4 4-2.54 1 Unit:mm 2 3 4 5 10 9 8 7 6 PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected] Unit: mm PETERMANN TECHNIK Time & Frequency Components 7 x 5 mm SMD 7.0+0.2 - 5.0+0.2 - 0.9+0.09 - 1.5max 1.2+0.15 - 0.23 2.54+0.13 - 0.6 #1 #2 #2 #6 #3 #4 1.0+0.13 - PIN #1 #2 #3 #4 #5 #6 CONNECTION GROUND INPUT OUTPUT GROUND SIGNAL GROUND Unit: mm PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97 http://www.petermann-technik.de | [email protected]