VECTRON TFS433X

Filename: tfs 433X.doc
Version 1.1
VI TELEFILTER
18.08.2005
Filter specification
TFS 433X
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
240 Ω || -2,5 pF
240 Ω || -2,5 pF
unbalanced
balanced
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 433X is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 433,92 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
ae = amin
Insertion loss
(reference level)
1,9
-
Nominal frequency
fN
-
Centre frequency 3dB
fC
433,92
PB
-
Passband
-
0,16
0,18
0,22
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
+
+
+
+
+
423,92
19,92
10,42
2,20
1,80
1,00
8,08
66,08
266,08
371,08
dB
max.
3,0
433,92
MHz
dB
MHz
fN ± 0,16 MHz
arel
Relative attenuation
fN
fN
fN
tolerance / limit
MHz … fN
MHz … fN
MHz … fN
+
+
+
0,16
0,18
0,22
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
+
+
+
+
+
19,92
10,42
2,20
1,80
0,82
8,08
66,08
266,08
371,08
566,08
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
…
…
…
…
…
…
…
…
…
…
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
DV voltage
VDC
Input power level
Operating temperature range
OTR
Storage temperature range
dB
dB
dB
max.
max.
max.
2
3
6
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
52
48
29
26
17
18
40
50
45
60
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
-
max.
6
V
-
max.
10
58
56
46
46
18
40
47
65
52
62
-
- 40 °C ... + 95°C
-
- 45 °C ... + 130°C
- 10
Frequency inversion temperature
Temperature coefficient of frequency
0,45
0,50
0,70
TCf **
- 0,03
dBm
°C
ppm/K
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 433X.doc
Version 1.1
VI TELEFILTER
18.08.2005
Filter specification
TFS 433X
2/5
0
0
-10
-0.5
-20
-1
-30
-1.5
magnitude in dB
magnitude in dB
Filter characteristic
-40
-50
-60
-2
-2.5
-3
-70
-3.5
-80
-4
-90
-4.5
-100
300
400
500
600
700
frequency in MHz
800
900
-5
1000
433.6
433.7
433.8
433.9
434
frequency in MHz
434.1
434.2
Construction and pin connection
(All dimensions in mm)
7
+0,20
SQ 3,81 - 0,10
5
433X
● T23
1
3
7
5
Input
Ground
Ground
Ground
Output
Output
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
1,2 Max.
0,1
12
0°
0,6
3
1,78
2,54
1
Date code
1
2
3
4
5
6
7
8
1,78
50 Ohm Test circuit
1
5
2
6
3, 4, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 433X.doc
Version 1.1
VI TELEFILTER
18.08.2005
Filter specification
TFS 433X
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
t
Po
PIN Marker
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 433X.doc
Version 1.1
VI TELEFILTER
18.08.2005
Filter specification
TFS 433X
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 433X.doc
VI TELEFILTER
Version 1.1
Filter specification
18.08.2005
TFS 433X
5/5
Version
Reason of Changes
Name
Date
1.0
1.1
- Generation of filter specification
- Change of storge temperature to +130°C
Noack
Sabah
06.06.2005
18.08.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.