Filename: tfs 456w.doc Version 1.2 VI TELEFILTER 14.09.2006 Filter specification TFS 456W 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 134 Ω || -8 pF 218 Ω || -6 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 456W is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) PB Passband Pass band ripple 8,25 33 20 17 20 70 MHz MHz MHz MHz MHz MHz dB max. 14,0 dB 18,4 MHz min. 0,3 dB max. 0,4 45 38 38 35 61 dB dB dB dB dB dB max. min. min. min. min. min. 1 40 35 35 40 50 dB dB dB dB dB dB ** 22 Ns max. 90 ns 456,0 MHz fN ± 8,25 MHz 1,0 dB arel Relative attenuation + + + 11 fN Nominal frequency fN fN fN fN fN fN Tolerance / limit … … … … … … fN fN fN fN fN fN + + + + 8,25 20 17 20 33 149 MHz MHz MHz MHz MHz MHz Group delay ripple within PB Return loss within PB - min. 10 dB Input power level - max. 13 dBm Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf *** - - 40 °C ... + 85°C - - 45 °C ... + 85°C -20 ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) to be particularly specified after the first samples. ***) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456w.doc Version 1.2 VI TELEFILTER 14.09.2006 Filter specification TFS 456W 2/5 0 0.91 -0.4 0.85 -12 -0.8 0.79 -18 -1.2 0.73 -24 -1.6 0.67 -2 0.61 -2.4 0.55 -42 -2.8 0.49 -48 -3.2 0.43 -54 -3.6 0.37 -30 -36 -60 306 336 366 396 426 456 486 frequency in MHz 516 546 576 606 -4 444 446.4 448.8 451.2 453.6 456 458.4 frequency in MHz 460.8 463.2 465.6 delay in µs 0 -6 magnitude in dB magnitude in dB Filter characteristic 0.31 468 Construction and pin connection (All dimensions in mm) 7 5 456W ● U37 3 1,1 120° +0,15 5 7 0,1 1,1 Date code: U V W ... Year + week 2006 2007 2008 1,8 Max. 1 Date code Ground Output Output Ground Ground Input Input RF Return Ground 0,64 3 5 - 0,10 1 1 2 3 4 5 6 7 8 2,54 50 Ohm Test circuit L1 C1 6 3 7 2 L3 L5 L4 1,4,5,8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456w.doc Version 1.2 VI TELEFILTER 14.09.2006 Filter specification TFS 456W 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,30 ± 0,1 Bo : 5,30 ± 0,1 Ct : 9,5 ± 0,1 t PIN Marker Po P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456w.doc Version 1.2 VI TELEFILTER 14.09.2006 Filter specification TFS 456W 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 456w.doc VI TELEFILTER Version 1.2 Filter specification 14.09.2006 TFS 456W 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 21.08.2006 1.1 - Change input power level Strehl 01.09.2006 1.2 - Created filter specification - Added termination impedances - Added typical values - Added filter characteristics - Added test circuit Chilla 14.09.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.