JDSU 10020476

COMMUNICATIONS COMPONENTS
CATV Band Dual Output Modulator
Key Features
• Flat frequency response
• Two optical output ports
• Integrated phase modulator
• High optical damage threshold
Applications
• High performance 1550 nm CATV
band transmitters
The JDSU community antenna television (CATV) band dual output modulator is
widely accepted for use in externally modulated 1550 nm transmitters. Two
optical outputs offer flat frequency response and excellent composite second
order distortion (CSO) performance. This product is rated for operation at
optical power levels to 200 mW.
A dedicated production line and strict process control measures ensure minimal
variation in device-to-device characteristics.
Typical Return Loss Curve, S11
Typical Frequency Response, S21
0
1
-5
0
dB
dB
-10
-1
-2
-15
-20
-25
-3
-4
0.00E+00
-30
4.00E-01
8.00E-01
1.20E+00
-35
0.00E+00
8.00E-01
1.20E+00
Frequency (GHz)
Frequency (GHz)
NORTH AMERICA : 800 498-JDSU (5378)
4.00E-01
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
CATV BAND DUAL OUTPUT MODULATOR
2
CATV Band Dual Output Modulator
Schematic
VRF
Phase Modulator
VBIAS
PM Fiber In
3 dB
SM Fiber Out
APETM Waveguides
CATV Band Dual Output Modulator
Dimensions Diagram
(Specifications in inches [mm] unless otherwise noted.)
5.66 [143.8]
OUT
.90 [22.9]
.69 [17.5]
DC
RF
PM
.57 [14.5]
2X .33 [8.3]
2X Ø.15 [Ø3.8] THRU
2X .15 [3.8]
4.400 [111.8]
4.70 [119.4]
4.11 [104.4]
.37 [9.4]
.10 [2.5]
.16 [4.0]
[
2X
.18 [4.4]
1.02 [25.9]
.39 [9.8]
1.70 [43.2]
2.78 [70.5]
3.53 [89.7]
CATV BAND DUAL OUTPUT MODULATOR
3
Specifications
Parameter
General
Material
Crystal orientation
Optical1
Operating wavelength
Input optical power
On/off extinction ratio
Optical return loss
Optical insertion loss2
Insertion loss imbalance between outputs
Electrical1
Intensity modulator
Vπ, signal electrode, 100 MHz
Vπ, bias electrode, DC3
Operating bandwidth
Amplitude flatness
Phase flatness
S11
Delta phase optical outputs4
Bias electrode impedance
Passive bias point, relative to quadrature, at 1550 nm
Phase Modulator
Half-wave voltage, DC
Operating bandwidth, DC
S11
Input impedance
Bias port
Applied DC voltage
Phase modulator port
Applied RF power
RF port
Applied DC voltage
Applied RF power
Mechanical
Input fiber
Specification
Lithium niobate
X-cut, y-propagating
Maximum
Minimum
Maximum
Maximum
Maximum
1540 to 1560 nm
200 mW
20 dB
-45 dB
4.5 dB
1.0 dB
Maximum
Maximum
Minimum
Maximum
Maximum
Maximum
Maximum
5.9 V
5.0 V
47 to 860 MHz
±0.5 dB
±5°
-18 dB
0.26°
>10 kΩ
±3 V
Maximum
8.5 V
2.5 GHz
-8 dB
50 Ω
Maximum
Maximum
±15 V
Maximum
30 dBm
Maximum
Maximum
0V
24 dBm
Output fiber
Electrical connectors (package)
Environmental
Operating temperature
Storage temperature
Fujikura SM 15-P-8/125-UV/UV-400, 70 cm minimum
Hytrel 900 µm loose tube, 12 inches
SMF-28, 95 cm minimum
Hytrel 900 µm loose tube 12 inches
SMA connectors
0 to 70 °C
-40 to 80 °C
1. All measurements made at 23°C unless otherwise noted.
2. Insertion loss is measured at the maximum of the modulator’s transfer function and does not include the 3 dB loss incurred when operated at quadrature.
3. The bias point of this device is most stable when operated with applied DC voltage close to 0 V.
4. For an 80 channel NTSC, 3% OMI CATV link, with correctly operating modulator bias control, 0.26° delta phase yields a maximum of 68 dBc CSO on both outputs.
CATV BAND DUAL OUTPUT MODULATOR
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
[email protected].
Sample: 10020476
Product Code
10020476
Description
1550 nm, PM/SM, no connectors
APE is a trademark of JDSU.
Hytrel is a registered trademark of E. I. du Pont de Nemours and Company.
SMF-28 and Fujikura SM-P-8/125-UV-400 are registered trademarks of Corning Incorporated.
All statements, technical information and recommendations related to the products herein are based upon information believed to be
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including
withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products
herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are
trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. ©2006 JDS Uniphase
Corporation. All rights reserved. 10133791 Rev. 001 05/06 CATVBDOM.DS.CC.AE
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com