POWERBOX 4050

MODULES
4000 Series
1 0 W - 3 3 K V
S I N G L E
O U T P U T
D C / D C
I N D U S T R I A L
Features
•
•
•
•
•
•
•
0 to 100% adjustability.
Voltage programmable.
Voltage monitor.
Remote on/off control.
EMI/RFI shielding.
Short circuit, reverse polarity protection.
Arc protection.
Specifications
Selection Tables
INPUT
Voltage
+24Vdc (+20% to -5%).
OUTPUT
Power
10W.
MODEL
NUMBER
OUTPUT
OUTPUT*1
VOLTAGE
CURRENT
4010
0 to 1,000V
10mA
0.1%
4020
0 to 2,000V
5mA
0.1%
4030
0 to 3,000V
3.3mA
0.2%
4050
0 to 5,000V
2mA
0.1%
4070
0 to 7,000V
1.4mA
0.1%
1mA
0.1%
RIPPLE
Voltage
See table.
Current
See table.
Ripple
See table.
4100
0 to 10,000V
Analog control
0 to 10 Volts = 0 to 100% output.
4120
0 to 12,000V
0.8mA
0.1%
Voltage monitor
0 to 10 Volts = 0 to 100% output..
4150
0 to 15,000V
0.67mA
0.1%
On/Off control
On = 0 Volts or N.C.
Off = 5 Volts
4200
0 to 20,000V
0.5mA
0.2%
4300*2
0 to 30,000V
0.33mA
0.4%
4330*2
0 to 33,000V
0.30mA
0.2%
Reference output
10 Volts (±0.5%).
ENVIRONMENTAL
Operating temperature
–10°C to +60°C.
Note: 1. At maximum rated output voltage.
2. No voltage monitor.
GENERAL
PIN#
FUNCTION
1
On/Off control
2
Ground/case
Fully encapsulated.
3
+24Volt input
Case material
Black anodised aluminum.
4
10 Volt reference output
Input connector
Molex 09-50-3071 (supplied).
5
Programming voltage
6
Internal potentiometer
7
Voltage monitor
Dimensions
104 x 78.7 x 35.56 mm (4010 to 4200).
104 x 91.4 x 35.56 mm (4300 to 4330).
Weight
675g.
Packaging
Molex pins
08-50-0106 (supplied).
High voltage leads
30KV 22AWG (4010 to 4200).
40KV 20AWG (4300 to 4330).
OPTIONS
Negative output voltage
PROGRAMMING
VOLTAGE
Apply 0-10V to pin 5 for 0-100% output.
RESISTANCE
Connect potentiometer to pin 4 (reference voltage),
connect wiper arm to pin 5, and connect
potentiometer to the ground.
Put “N” after model (eg 4300N).
MANUAL
222
Connect pin 6 to pin 5, turn front panel pot for voltage
adjust.