POWERBOX VI-JZ-CX

MODULES
VI J00
2 5 - 1 0 0 W
P C B
M O U N T I N G
C O M P O N E N T S
Features
•
•
•
•
•
•
•
Inputs: 10 to 400VDC
Output: 1 to 95VDC
UL, CSA, TÜV, BABT, CF, VDF
80-90% efficiency (typical)
Up to 27 watts/cubic inch
ZCS power architecture
Low noise FM control
Specifications
INPUT
Input voltage
Selection Table
See table
OUTPUT
PRODUCT GRADE
E, C, I, M
Output voltage
See table
Output power
See table
Output ripple
1% pk-pk
Load regulation
0.05%
Line regulation
0.05%
Current limit setting
105%–125%
Set point accuracy
0.5%
Low–high trim voltage
50%–110%
Total remote sense
Compensation
0.5V
OPERATING
MTBF
>1,000,000 hrs
Efficiency
80%–90%
Baseplate operating temp. 100°C
NOTES:
Isolation
(1)
Maximum Output for:
5V Outputs
50W
>5V Outputs
75W
<5V Outputs
10A
*100W @ 5V (20A), 300V input only.
Input – Output: 3000V rms
ENVIRONMENTAL
Cooling
External cooling may be required, consult sales
office
STANDARDS AND APPROVALS
Safety
UL1950, CSA C22.2 No.950, TÜV IEC950,
EN60950
C-Tick
AS/NZS CISPR11 Group 1 Class A
MECHANICAL
Dimensions
58x61x12.7mm
Selection Table Guide
VI - J [a] [b] - [c] [d]
Note: For RoHS version replace VI with VE.
Mechanical Drawings See page 230
228
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
Nominal
Range Notes
0= 12V
10–20V (2)
Z = 2V
2 = 15V
1= 24V
21–32V (3)
Y = 3.3V
N = 18.5V
W= 24V
18–36V (3)
0 = 5V
3 = 24V
2= 36V
21–56V (1)
X = 5.2V
L = 28V
3= 48V
42–60V (5)
W = 5.5V
J = 36V
N= 48V
36–76V (4)
V = 5.8V
K = 40V
4= 72V
55–100V (4)
T = 6.5V
4 = 48V
T= 110V
66–160V (4)
R = 7.5V
H = 52V
5= 150V
100–200V (4)
M = 10V
F = 72V
6= 300V
200–400V (5)
1 = 12V
D = 85V
7= 150/300V
100–375V (1)
P = 13.8V
B = 95V
C = PRODUCT GRADE
D = OUTPUT POWER/CURRENT
Size Module
V out ≥5V
V out <5V
E= -10°C to +100°C
Z= 25W
—
C= -25°C to +100°C
Y = 50W
Y= 10A
I= -40°C to +100°C
X = 75W
X= 15A
M= -55°C to +100°C
W = 100W
W= 20A
(2)
50W
75W
15A
(3)
75W
100W
20A
(4)
75W
100W
20A
(5)
100W*
100W
20A