VI-J00 Series

DC-DC PCB MOUNTED CONVERTERS & POWER MODULES
VI-J00 Series
2 5 - 1 0 0 W AT T S - D C / D C C O N V E R T E R S H A L F B R I C K
FEATURES
•
•
•
•
•
•
•
•
•
Inputs: 10 to 400VDC
Output: 1 to 95VDC
cURus, cTUVus, CE Mark
Up to 90% efficiency
Up to 50 watts/cubic inch
ZCS power architecture
Low noise FM control
Remote sense and current limit
Logic disable
SPECIFICATIONS
SELECTION TABLES
INPUT
Input voltage
A = INPUT VOLTAGE
See table
OUTPUT
NOMINAL
B = OUTPUT VOLTAGE
RANGE NOTES
0= 12V
10-20V
(2)
Z = 2V
2 = 15V
Product grade
E, C, I, M
1= 24V
21-32V
(3)
Y = 3.3V
N = 18.5V
Output voltage
See table
W= 24V
18-36V
(3)
0 = 5V
3 = 24V
Output power
See table
2= 36V
21-56V
(1)
X = 5.2V
L = 28V
Output ripple
1% pk-pk
3= 48V
42-60V
(5)
W = 5.5V
J = 36V
Load regulation
0.05%
N= 48V
36-76V
(4)
V = 5.8V
K = 40V
Line regulation
0.05%
4= 72V
55-100V
(4)
T = 6.5V
4 = 48V
Current limit setting
105%-125%
T= 110V
66-160V
(4)
R = 7.5V
H = 52V
Set point accuracy
0.5%
5= 150V
100-200V
(4)
M = 10V
F = 72V
Low-high trim voltage
Total remote sense
Compensation
50%-110%
0.5V
6= 300V
200-400V
(5)
1 = 12V
D = 85V
7= 150/300V
100-375V
(1)
P = 13.8V
B = 95V
C = PRODUCT GRADE
OPERATING
MTBF
>1,000,000 hrs
Efficiency
78%-90% Model Dependant
Baseplate operating temp. 100°C
Isolation
Input - Output: 3000V rms
ENVIRONMENTAL
Cooling
UL60950-1, CSA60950-1, EN60950-1, Low
Voltage Directive (2006/95/EC)
MECHANICAL
Dimensions
V OUT 5V
V OUT <5V
E= -10°C to +100°C
Z= 25W
Z = 5A
C= -25°C to +100°C
Y = 50W
Y= 10A
I= -40°C to +100°C
X = 75W
X= 15A
M= -55°C to +100°C
W = 100W
W= 20A
External cooling may be required, consult
sales office
STANDARDS AND APPROVALS
Safety
D = OUTPUT POWER/CURRENT
SIZE MODULE
58x61x12.7mm
NOTES:
MAXIMUM OUTPUT FOR:
(1)
(2)
(3)
(4)
(5)
5V Outputs
50W
50W
>5V Outputs
75W
75W
75W
75W
100W*
100W
100W
100W
<5V Outputs
10A
15A
20A
20A
20A
*100W @ 5V (20A), 300V input only.
NOTE: For RoHS version replace VI with VE
SELECTION TABLE GUIDE
VI - J [a] [b] - [c] [d]
250
Doc. No. PBC9 Rev.C 28-4-11