TRUMPower 65 WATT MEDICAL POWER SUPPLIES TM66 SERIES D E S C R IP T IO N ( LV D ) The TM66 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 51 to 65 watts of continuous power. They operate at 90 to 264VAC input voltage without the need of voltage selection. They are ideally suited for use in medical equipments. All models meet the safety requirements of UL, CSA and IEC. RoHS F E AT U R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ Recognized or certified by UL, CSA and TÜV Small size 100% burn-in 9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e Input surge current protection O v e r v o l ta g e p r o t e c t i o n Overcurrent protection S a f e t y Sta n d a r d A p p r o va l s : ‧ Compliant with RoHS requirement UL 2601-1 CSA C22.2 No. 601.1 INPUT SPECIFICATIONS I n p u t v o l ta g e : Input frequency: Input current: 9 0 t o 2 6 4 VA C 47 to 63 Hz 1 . 6 0 A ( r m s ) f o r 11 5 VA C 1 . 0 0 A ( r m s ) f o r 2 3 0 VA C E a r t h l e a k a g e c u r r e n t : 9 0 µ A m a x . @ 11 5 VA C , 6 0 H z 1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z TÜV EN60601-1 GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Total output power: 65 watts maximum Ripple and noise: 1% peak to peak maximum Overvoltage protection: Provided on output; set at 112 – 132% of its nominal output voltage Overcurrent protection: The output protected to short circuit conditions Temperature coefficient: All outputs ±0.04%/ºC maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change E N V I R O N M E N TA L S P E C I F I C AT I O N S Switching frequency: 42KHz ±5KHz Efficiency: 75% minimum on models with Vo ≥12V, 6% minimum on the others Hold-up time: 10 msec minimum at 110VAC Line regulation: ±0.5% maximum at full load Inrush current: 17 amps @ 115VAC or 40 amps @230VAC, at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 400,000 hours minimum at full load at 25ºC ambient , calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2: 2001) EN55011: Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated Class B conducted, Class B radiated VCCI: EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: 0ºC to +70ºC EN61000-4-4: Radiated immunity, 3V/m for 80~2500MHz Fast transient/burst, ±2KV -40ºC to +85ºC 5% to 95% non-condensing Derate from 100% at +50ºC linearly to 50% at +70ºC EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: EN61000-4-11: Magnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms Operating temperature: Storage temperature: Relative humidity: Derating: Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com MEDICAL GRADE TM66 SERIES OUTPUT VOLTAGE/ CURRENT RATING CHART Output #1 Vnom. Imin. Imax. Product No. Tol. Output #2 Imin. Imax. Vnom. Tol. Output #3 Imin. Imax. Vnom. Maximum Output Power Tol. TM66-5.1 5.1V 0A 10A 3% (N/A) (N/A) 51W TM66-12 12V 0A 5.5A 2% (N/A) (N/A) 65W TM66-15 15V 0A 4.4A 2% (N/A) (N/A) 65W TM66-18 18V 0A 3.7A 2% (N/A) (N/A) 65W TM66-24 24V 0A 2.8A 2% (N/A) (N/A) 65W TM66-28 28V 0A 2.4A 2% (N/A) (N/A) 65W NOTE: Ripple and noise: Peak-to-peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at rated line voltage and load ranges. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal. 5. P4 is for ±sense connections and mates with Molex housing 22-01-1023 and Molex 40445 series crimp terminal. 6. Weight: 330 grams (PCB format) 7. VR1 is for output voltage adjustment. PIN CHART CONN P1 P2 P3 P4 PIN Product No. 1 TM66-5.1 TM66-12 TM66-15 TM66-18 AC LIVE 3 1 1 2 3 4 5 6 AC AC OUTPUT OUTPUT OUTPUT RETURN RETURN RETURN NEUTRAL GROUND #1 #1 #1 1 2 +SENSE -SENSE TM66-24 TM66-28 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com