PU110 - PROTEK POWER

72-110 WATT ITE POWER SUPPLIES
DESCRIPTION
PU110 SERIES
(LVD)
The PU110 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of
delivering 72-110 watts of continuous power at 25 CFM
forced air cooling or 60-80 watts at convection cooling.
They operate at 85-264 VAC input voltage without the
need of a selector strap. They are ideally suited for use
in small to medium size digitally-based systems, such as
point-of-sale equipment, microprocessor based systems,
and telecom equipment. All models meet the safety
requirements of UL, CSA and IEC.
RoHS
SAFETY STANDARD APPROVALS
UL 60950-1
File No. E137410
FEATURES
z
z
z
z
z
z
z
z
Recognized or certified by UL, CSA and TÜV
Power Fail Detect (PFD)signal
100% burn-in
W i d e i n p u t r a n g e 8 5 - 2 6 4 VA C
Input surge current protection
Overvoltage protection
Overcurrent protection
Compliant with RoHS requirements
CSA C22.2 No. 60950-1
File No. LR93632
TÜV EN 60950-1
Certificate No. R9352008
GENERAL SPECIFICATIONS
Switching frequency:
20 KHz to 250 KHz, varied with load and
line
Efficiency:
70% minimum on single output models
with Vo ≧12V, 65% minimum on the
others
Hold-up time:
12 ms minimum at 110 VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
15 A @ 115 VAC or 30 A @ 230VAC, at
25℃ cold start
Withstand voltage:
3000 VAC from input to output,
1500 VAC from input to ground,
500 VAC from output to ground
MTBF:
400,000 hours minimum at full load
at 25℃ ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN55024)
EN55022:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8 KV air and ±4 KV contact
EN61000-4-3:
Radiated immunity, 3 V/m
EN61000-4-4:
Fast transient/burst, ±1 KV
EN61000-4-5:
Surge, ±1 KV diff., ±2 KV com.
EN61000-4-6:
Conducted immunity, 3 Vrms
EN61000-4-8:
Magnetic field immunity, 1 A/m
EN61000-4-11:
Voltage dip immunity, 30% reduction for
500 ms, and >95% reduction for 10 ms
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
(Touch current)
85-264 VAC
47-63Hz
3.20 A (rms) for 115 VAC
1.80 A (rms) for 230 VAC
0.40 mA max. @ 115 VAC, 60 Hz
0.75 mA max. @ 230 VAC, 50 Hz
OUTPUT SPECIFICATIONS
Output voltage /current:
Maximum output power:
Ripple and noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
Transient response:
See rating chart.
See rating chart.
1% peak to peak maximum
Provided on output #1 only; set at
112-132% of its nominal output
voltage
All outputs protected to short circuit
conditions
All outputs ±0.04% /℃ maximum
Maximum excursion of 4% or better on
all models, recovering to 1% of final
value within 500 us after a 25% step
load change
INTERFACE SIGNALS
PFD:
TTL logic high for normal operation and TTL logic low
upon loss of input power. This signal appears at least
1 ms prior to +5V output dropping 5% below its
nominal value. This signal also provides a minimum
delay of 100 ms after +5V is within regulation.
OUTPUT POWER DERATING CURVE
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Cooling:
0℃ to +70℃
-40℃ to +85℃
5% to 95% non-condensing
Derate from 100% at +50℃ linearly to
50% at +70℃
110 watts continuous output power at 25
CFM forced air cooling or 80 watts at
convection cooling
59
UNIVERSAL INPUT
PU110 ITE SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
(2)(4)
Output # 1
(3)
Model
PU110-10-1A
PU110-10A
PU110-12A
PU110-13A
PU110-14A
PU110-16A
PU110-23A
PU110-31A
PU110-32A
PU110-40A
PU110-41A
PU110-42A
PU110-45A
PU110-45-1A
PU110-45-2A
PU110-46A
V1
3.3 V
5V
12 V
15 V
24 V
30 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
Imin.
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
2A
0A
0A
Imax.
22.0 A
22.0 A
9.0 A
7.5 A
4.5 A
3.6 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
Output # 2
V2
Tol.
±3%
±3%
±2%
±2%
±2%
±2%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
+12 V
+12 V
+15 V
+12 V
+15 V
+12 V
+12 V
+12 V
+24 V
+15 V
Output # 3
Imin. Imax. Peak(1) Tol.
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
V3
Output # 4
Imin. Imax. Tol.
V4
Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
5A
5A
4A
5A
4A
5A
5A
5A
3A
4A
9.0 A
9.0 A
7.5 A
9.0 A
7.5 A
9.0 A
9.0 A
9.0 A
5.0 A
7.5 A
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
(N/A)
-12 V
-15 V
-12 V
-15 V
-12 V
-12 V
-12 V
-12 V
-15 V
0A
0A
0A
0A
0A
0A
0A
0A
0A
1A
1A
1A
1A
1A
1A
1A
1A
1A
±4%
±4%
±4%
±4%
±4%
±4%
±4%
±4%
±4%
Tol.
(N/A)
(N/A)
(N/A)
-5 V
0A
+24 V
0A
+12 V
0A
+24 V
0A
+24 V 1.5 A
+12 V
0A
-5 V
0A
1A
1A
1A
1A
3A
1A
1A
±4%
±4%
±4%
±4%
±10%
±4%
±4%
Max.
Output
(2)
Power
60 W / 72 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
80 W / 110 W
NOTES:
1.
Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 130 watts.
2.
110 watts maximum at 25 CFM forced air cooling or 80 watts maximum at convection cooling, except model PU110-10-1A which is rated
maximum 60 W at convection cooling or 72 W at 25 CFM forced air cooling.
3.
Safety agency approvals are for the above listed models in PCB format. To order models with metallic L-bracket or box, change suffix “A” to “B”
for L-bracket format, to “C” for enclosed format (mechanical details shown in page 71-72), e.g. PU110-31C.
4.
The output #1 of model PU110-45-1A needs a minimum current of 2 A to support the other outputs at their maximum rated loads
5.
Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load
ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output.
MECHANICAL SPECIFICATIONS
NOTES:
1.
Dimensions shown in inches [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Connector P1: Molex header 09-65-2058 or
equivalent, mating with Molex housing
09-50-1051 or equivalent.
4.
Connector P2 mates with Molex housing
09-50-3131 or equivalent.
5.
Weight: 640 grams (1.408 lbs.) approx.
6.
The copper pad of the mounting hole near P1
is for system grounding through a metallic
stand-off to system chassis.
PIN CHART
MODEL
PU110-10-1A
PU110-10A
PU110-12A
PU110-23A
PU110-31A
PU110-40A
PU110-41A
PU110-42A
PU110-45A
PIN
PU110-13A
PU110-14A
PU110-16A
PU110-32A
PU110-45-1A
PU110-45-2A
PU110-46A
1, 2, 3
4, 5
6, 7
8, 9
10
11
12
13
+V1
V1 & PFD Return V1 & PFD Return
+V1
PFD
N.C.
KEY
N.C.
V1
V1
Common Return
Common Return
Common Return
Common Return
V2
V2
PFD
PFD
N.C.
V3
KEY
KEY
N.C.
N.C.
V1
Common Return
Common Return
V2
PFD
V3
KEY
V4
60