DBLECTRO NVFSA15DC24V

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NVFS
NHG RELAYS
Operation condition
NVFS
Patent No.:99215698.X
25.2
21
Features
Small size and light weight. Heavy contact load (30A).
Contact arrangement Form A.
Suitable for automobile and lamp accessories application.
Insert mounting ,With metal frame.
100M
min (at 500VDC)
Dielectric Strength
Between contacts
Between contact and coil
50Hz 500V
50Hz 750V
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
147m/s2
11ms
10~40Hz double amplitude
8N
235
2
3 0.5s
-40~105
85% (at 40 )
32g
Item 6 of IEC255-5
Item 6 of IEC255-5
Ordering Information
1
2
15
of IEC255-19-1 and minimum sample size 24.
mm /inch
4
A:1A
Fuse-wire
5.2
0.205
Max. Switching Current:30A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
4.85
0.191
34.6
1.362
36max.
1.417max.
4-6.3X0.8
0.248 0.031
12
0.472
25.2max.
0.992max.
Coil Parameter
006-1800
Dimensions
Coil voltage
VDC
6
Coil
resistance
10%
Pickup
voltage
VDC(max)
(65%of rated
voltage )
Release
voltage
VDC(min)
(20% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Max.
7.8
86
4-7
16.8
0.661
Rated
5.3
0.209
34.6Max.
1.362max.
6
0.236
1.5
1
0.453
1A SPSTNO
AgSnO2
15A 30A/14VDC
420W
75VDC
50m
105
107
0.8
0.031
24.5
0.965
32
1.260
21
0.827
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
Life
Mechanical
19.1
0.752
14.9
0.587
9
0.354
Shrouded type with bracket
3 Contact rating 15:15A/14VDC 30:30A/14VDC
4 Coil rated Voltage(V) DC: 6,12,24
5.1
0.201
Dash
numbers
IEC68-2-3 Test Ca
Dimensions
DC12V
3
1 Part number NVFS
2 Contact arrangement
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
1.27mm
Qualification inspection:
Perform the qualification test as specified in the table
NVFS A
Item 7 of IEC255-5
6.5
0.256
13.5
0.531
27.5
1.083
32.6
Insulation Resistance
20
3.9
1.2
0.276 0.047
86(+)
30
87
87
30
1.2
85
012-1800
024-1800
12
24
15.6
31.2
80
320
7.8
15.6
2.4
1.8
7
4.8
Fuse-wise
5
8.4
0.331
85
17.9
0.705
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Mounting (Bottom view)
Wiring diagram (Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.