1 FEATURES
(1) Display format :112× 64 dot-matrix
(2) Construction : LCD panel, and COF.
(3) Display type : FSTN, Positive, Transflective, 6 o’clock view
(4) Driver : IC S6B1713A15-B0CZ
(5) 3.0V power input.
(6) Extended temperature type.
(7) ROHS compliant.
2 MECHANICAL DATA
Parameter
Stand Value
Unit
Dot size
0.245(W) × 0.310(H)
mm
Dot pitch
0.260(W) × 0.325(H)
mm
Viewing area
33.6(W) × 22.3(H)
mm
Module size
39.0(W) × 66.6(H) ×5.7 (T)
mm
3 ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
Unit
Logic Circuit Supply Voltage
VDD-VSS
-0.3
7.0
V
LCD Driving Voltage
VDD-VO
0
14
V
Input Voltage
VI
-0.3
VDD+0.3
V
Operating Temp.
TOP
-20
70
°C
Storage Temp.
TSTG
-30
80
°C
Date: 2006/7/26
AMPIRE CO., LTD.
3
4 ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Condition
Min
Typ
----- Electronic Characteristics -----
Max
Unit
Logic Circuit
Supply Voltage
VDD-VSS
--
--
3.0
--
V
LCD Driving
Voltage
V0-VSS
-20°C
7.96
8.34
8.66
V
25°C
7.57
7.92
8.27
70°C
7.31
7.59
7.91
VIH
--
0.8 VDD
--
VDD
V
VIL
IDD
-VDD = 3V
0
--
---
0.2 VDD
1.2
V
mA
Input Voltage
Logic Supply
Current
Note
----- Optical Characteristics ----Contrast
CR
25°C
Rise Time
tr
25°C
--
150
225
ms
Fall Time
tf
25°C
--
320
480
ms
Viewing Angle
Range
θf
25°C &
40
--
--
θb
CR≥2
30
--
--
θl
40
--
--
θr
40
--
--
--
64
--
Frame Frequency
fF
25°C
2
5
Note 1
Note 2
Note 3
Deg.
Hz
(NOTE 1) Contrast ratio :
CR = (Brightness in OFF state) / (Brightness in ON state)
Date: 2006/7/26
AMPIRE CO., LTD.
4
( NOTE 2 ) Response time :
(NOTE 3) Viewing angle
Date: 2006/7/26
AMPIRE CO., LTD.
5
5 BLOCK DIAGRAM &POWER INPUT
PIN NO
1
2
3
4
5
6-13
14
15
Power Supply : Using
Voltage Converter Circuit
Voltage Regulator Circuit
(External Resistor , INTRS = ”L”)
&Voltage Follower Circuit
R1
VCC
R2
JP1
C2
C4
C3
SYMBOL
LCD_CS
LCD_RESET
A0
WRITE
READ
DO-D7
VSS
VDD
VCC
JP2
C1
C5 C6 C7 C8 C9
VSS VR V0 V1 V2 V3 V4
COM 33
COM 64
C3- C2- C1- VOUT
PS MI
C3+ C2+ C1+ VDD
COM 1
KS0713
S6B1713
COM 32
SEG 112
SEG 1
SEG 112
SEG 1
COM 64
COM 33
112*64DOTS
COM 32
COM 1
DOT 1
Date Shift Direction Setting : SHL=0 , ADC=0
JP1: Select Serial(L) / Parallel(H)
JP2: Select 8080(L) / 6800(H)
Date: 2006/7/26
AMPIRE CO., LTD.
6
6 PIN CONNECTIONS
No.
Symbol
Function
1
LCD_CS
Chip select input
2
LCD_RESET
Hardware reset input
3
A0
Select address register/data register
4
WRITE
Write control signal input
5
READ
Read control signal input
6
DO
Data bus
7
D1
Data bus
8
D2
Data bus
9
D3
Data bus
10
D4
Data bus
11
D5
Data bus
12
D6
Data bus
13
D7
Data bus
14
VSS
Power Supply Ground (0V)
15
VDD
Power Supply (3V)
Date: 2006/7/26
AMPIRE CO., LTD.
7
7 TIMING CHARACTERISTICS
7.1 Read/Write Characteristics(8080-series MPU)
Date: 2006/7/26
AMPIRE CO., LTD.
8
7.2 Read/Write Characteristics(6800-series MPU)
Date: 2006/7/26
AMPIRE CO., LTD.
9
8 QUALITY AND RELIABILITY
8.1
TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
8.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E, inspection level II,
normal inspection, and single sampling plan tables for normal, tightened, and reduced
inspection.
8.3 ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
8.4 APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under flo urescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date: 2006/7/26
AMPIRE CO., LTD.
10
8.5
INSPECTION QUALITY CRITERIA
Item
Description of defects
Function
Dimension
Black spots
Short circuit or Pattern cut
Deviation from drawings
Ave . dia . D
area A
area B
Disregard
D≤0.2
3
4
0.2<D≤0.3
2
3
0.3<D≤0.4
0.4<D
0
1
Width W, Length L
A
B
disregard
W≤0.03
3
4
0.03<W≤0.05
1
1
0.05<W≤0.07 , L≤3.0
See line criteria
Average diameter D 0.2 < D < 0.5 mm
for N = 4 , D > 0.5 for N = 1
Rainbow color or newton ring.
Black lines
Bubbles in
polarizer
Color
uniformity
Glass
Scratches
Contrast
ratio
Response
time
Viewing
angle
Class of
Defects
Major
Major
Minor
Acceptable level
(%)
0.65
1.5
2.5
Minor
2.5
Minor
2.5
Minor
2.5
Obvious visible damage.
Minor
2.5
See note 1
Minor
2.5
See note 2
Minor
2.5
See note 3
Minor
2.5
ZONE A active area
ZONE B viewing area
Date: 2006/7/26
AMPIRE CO., LTD.
11
8.6 RELIABILITY
Test Item
Test Conditions
High Temperature Operation
70 ± 3°C , t=96 hrs
Low Temperature Operation
-20 ± 3°C , t=96 hrs
Note
High Temperature Storage
80± 3°C , t=96 hrs
1,2
Low Temperature Storage
-30± 3°C , t=96 hrs
1,2
40°C , Humidity 90%, 96 hrs
1,2
Humidity Test
-20°C (30 min.) ~ 25°C (5 min.) ~ 70°C (30 min.)
1,2
( 1 cycle )
Total 5 cycle
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
2
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
Thermal Shock Test
Date: 2006/7/26
AMPIRE CO., LTD.
12
9 HANDLING PRECAUTIONS
(1) An LCD module is a fragile item and should not be subjected to strong mechanical
shocks.
(2) Avoid applying pressure to the module surface. This will distort the glass and cause a
change in color.
(3) Under no circumstances should the position of the bezel tabs or their shape be modified.
(4) Do not modify the display PCB in either shape or positioning of components.
(5) Do not modify or move location of the zebra or heat seal connectors.
(6) The device should only be soldered to during interfacing. Modification to other areas of
the board should not be carried out.
(7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make
contact with the skin. If contact is made rinse immediately.
(8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or
Ethyl alcohol. The use of water, ketone or aromatic is not permitted.
(9) Prior to initial power up input signals should not be applied.
(10) Protect the module against static electricity and observe appropriate anti-static
precautions.
Date: 2006/7/26
AMPIRE CO., LTD.
13
晶 采 光 電 科技
10 OUTLINE DIMENSION
Date: 2006/7/26
AMPIRE CO., LTD.
14
晶采 光 電 科技
Date: 2006/7/26
AMPIRE CO., LTD.
15
晶采 光 電 科技
11 PACKING METHOD
Date: 2006/7/26
AMPIRE CO., LTD.
16