A MP I R E SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. AF-11264CFI-33H(V)(R) APPROVED BY DATE APPROVED BY Date: 2006/7/26 CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 RECORD OF REVISION Revision Date 2006/7/26 Date: 2006/7/26 Contents New Release AMPIRE CO., LTD. Editor Lorry 2 1 FEATURES (1) Display format :112× 64 dot-matrix (2) Construction : LCD panel, and COF. (3) Display type : FSTN, Positive, Transflective, 6 o’clock view (4) Driver : IC S6B1713A15-B0CZ (5) 3.0V power input. (6) Extended temperature type. (7) ROHS compliant. 2 MECHANICAL DATA Parameter Stand Value Unit Dot size 0.245(W) × 0.310(H) mm Dot pitch 0.260(W) × 0.325(H) mm Viewing area 33.6(W) × 22.3(H) mm Module size 39.0(W) × 66.6(H) ×5.7 (T) mm 3 ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min Max Unit Logic Circuit Supply Voltage VDD-VSS -0.3 7.0 V LCD Driving Voltage VDD-VO 0 14 V Input Voltage VI -0.3 VDD+0.3 V Operating Temp. TOP -20 70 °C Storage Temp. TSTG -30 80 °C Date: 2006/7/26 AMPIRE CO., LTD. 3 4 ELECTRO-OPTICAL CHARACTERISTICS Parameter Symbol Condition Min Typ ----- Electronic Characteristics ----- Max Unit Logic Circuit Supply Voltage VDD-VSS -- -- 3.0 -- V LCD Driving Voltage V0-VSS -20°C 7.96 8.34 8.66 V 25°C 7.57 7.92 8.27 70°C 7.31 7.59 7.91 VIH -- 0.8 VDD -- VDD V VIL IDD -VDD = 3V 0 -- --- 0.2 VDD 1.2 V mA Input Voltage Logic Supply Current Note ----- Optical Characteristics ----Contrast CR 25°C Rise Time tr 25°C -- 150 225 ms Fall Time tf 25°C -- 320 480 ms Viewing Angle Range θf 25°C & 40 -- -- θb CR≥2 30 -- -- θl 40 -- -- θr 40 -- -- -- 64 -- Frame Frequency fF 25°C 2 5 Note 1 Note 2 Note 3 Deg. Hz (NOTE 1) Contrast ratio : CR = (Brightness in OFF state) / (Brightness in ON state) Date: 2006/7/26 AMPIRE CO., LTD. 4 ( NOTE 2 ) Response time : (NOTE 3) Viewing angle Date: 2006/7/26 AMPIRE CO., LTD. 5 5 BLOCK DIAGRAM &POWER INPUT PIN NO 1 2 3 4 5 6-13 14 15 Power Supply : Using Voltage Converter Circuit Voltage Regulator Circuit (External Resistor , INTRS = ”L”) &Voltage Follower Circuit R1 VCC R2 JP1 C2 C4 C3 SYMBOL LCD_CS LCD_RESET A0 WRITE READ DO-D7 VSS VDD VCC JP2 C1 C5 C6 C7 C8 C9 VSS VR V0 V1 V2 V3 V4 COM 33 COM 64 C3- C2- C1- VOUT PS MI C3+ C2+ C1+ VDD COM 1 KS0713 S6B1713 COM 32 SEG 112 SEG 1 SEG 112 SEG 1 COM 64 COM 33 112*64DOTS COM 32 COM 1 DOT 1 Date Shift Direction Setting : SHL=0 , ADC=0 JP1: Select Serial(L) / Parallel(H) JP2: Select 8080(L) / 6800(H) Date: 2006/7/26 AMPIRE CO., LTD. 6 6 PIN CONNECTIONS No. Symbol Function 1 LCD_CS Chip select input 2 LCD_RESET Hardware reset input 3 A0 Select address register/data register 4 WRITE Write control signal input 5 READ Read control signal input 6 DO Data bus 7 D1 Data bus 8 D2 Data bus 9 D3 Data bus 10 D4 Data bus 11 D5 Data bus 12 D6 Data bus 13 D7 Data bus 14 VSS Power Supply Ground (0V) 15 VDD Power Supply (3V) Date: 2006/7/26 AMPIRE CO., LTD. 7 7 TIMING CHARACTERISTICS 7.1 Read/Write Characteristics(8080-series MPU) Date: 2006/7/26 AMPIRE CO., LTD. 8 7.2 Read/Write Characteristics(6800-series MPU) Date: 2006/7/26 AMPIRE CO., LTD. 9 8 QUALITY AND RELIABILITY 8.1 TEST CONDITIONS Tests should be conducted under the following conditions : Ambient temperature : 25 ± 5°C Humidity : 60 ± 25% RH. 8.2 SAMPLING PLAN Sampling method shall be in accordance with MIL-STD-105E, inspection level II, normal inspection, and single sampling plan tables for normal, tightened, and reduced inspection. 8.3 ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 8.4 APPEARANCE An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under flo urescent light. The inspection area of LCD panel shall be within the range of following limits. Date: 2006/7/26 AMPIRE CO., LTD. 10 8.5 INSPECTION QUALITY CRITERIA Item Description of defects Function Dimension Black spots Short circuit or Pattern cut Deviation from drawings Ave . dia . D area A area B Disregard D≤0.2 3 4 0.2<D≤0.3 2 3 0.3<D≤0.4 0.4<D 0 1 Width W, Length L A B disregard W≤0.03 3 4 0.03<W≤0.05 1 1 0.05<W≤0.07 , L≤3.0 See line criteria Average diameter D 0.2 < D < 0.5 mm for N = 4 , D > 0.5 for N = 1 Rainbow color or newton ring. Black lines Bubbles in polarizer Color uniformity Glass Scratches Contrast ratio Response time Viewing angle Class of Defects Major Major Minor Acceptable level (%) 0.65 1.5 2.5 Minor 2.5 Minor 2.5 Minor 2.5 Obvious visible damage. Minor 2.5 See note 1 Minor 2.5 See note 2 Minor 2.5 See note 3 Minor 2.5 ZONE A active area ZONE B viewing area Date: 2006/7/26 AMPIRE CO., LTD. 11 8.6 RELIABILITY Test Item Test Conditions High Temperature Operation 70 ± 3°C , t=96 hrs Low Temperature Operation -20 ± 3°C , t=96 hrs Note High Temperature Storage 80± 3°C , t=96 hrs 1,2 Low Temperature Storage -30± 3°C , t=96 hrs 1,2 40°C , Humidity 90%, 96 hrs 1,2 Humidity Test -20°C (30 min.) ~ 25°C (5 min.) ~ 70°C (30 min.) 1,2 ( 1 cycle ) Total 5 cycle Sweep frequency : 10 ~ 55 ~ 10 Hz/1min Amplitude : 0.75mm Vibration Test (Packing) 2 Test direction : X.Y.Z/3 axis Duration : 30min/each axis Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35°C , 45-65%RH). Definitions of life end point : l Current drain should be smaller than the specific value. l Function of the module should be maintained. l Appearance and display quality should not have degraded noticeably. l Contrast ratio should be greater than 50% of the initial value. Thermal Shock Test Date: 2006/7/26 AMPIRE CO., LTD. 12 9 HANDLING PRECAUTIONS (1) An LCD module is a fragile item and should not be subjected to strong mechanical shocks. (2) Avoid applying pressure to the module surface. This will distort the glass and cause a change in color. (3) Under no circumstances should the position of the bezel tabs or their shape be modified. (4) Do not modify the display PCB in either shape or positioning of components. (5) Do not modify or move location of the zebra or heat seal connectors. (6) The device should only be soldered to during interfacing. Modification to other areas of the board should not be carried out. (7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make contact with the skin. If contact is made rinse immediately. (8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or Ethyl alcohol. The use of water, ketone or aromatic is not permitted. (9) Prior to initial power up input signals should not be applied. (10) Protect the module against static electricity and observe appropriate anti-static precautions. Date: 2006/7/26 AMPIRE CO., LTD. 13 晶 采 光 電 科技 10 OUTLINE DIMENSION Date: 2006/7/26 AMPIRE CO., LTD. 14 晶采 光 電 科技 Date: 2006/7/26 AMPIRE CO., LTD. 15 晶采 光 電 科技 11 PACKING METHOD Date: 2006/7/26 AMPIRE CO., LTD. 16