SPECIFICATIONS FOR LCD MODULE

A MP I R E
SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
APPROVED
AF-128128C2FI-25H
BY
DATE
Approved For Specifications
Approved For Specifications & Sample
APPROVED BY
Date : 2004/8/30
CHECKED BY
AMPIRE CO., LTD.
ORGANIZED BY
1
RECORD OF REVISION
Revision Date
2004/8/30
Contents
Patrick
New Release
Date : 2004/8/30
Editor
AMPIRE CO., LTD.
2
1
FEATURES
(1) Display format : 128×128 dots, 1/128 duty.
(2) Construction : LCD panel and COF.
(3) Display type : FSTN , Transflective, Positive , 6 o’clock view
(4) Controller : HD66750S
(5) +2.8V single power input.
(6) Extend temperature type.
2
3
MECHANICAL DATA
Parameter
Stand Value
Unit
Dot size
0.199(W) × 0.219(H)
mm
Dot pitch
0.213(W) × 0.233(H)
mm
Viewing area
30.5(W) ×32.0 (H)
mm
Module size
36.3(W) × 83.5(H) × 1.4 max.(T)
mm
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
Unit
Logic Circuit Supply Voltage
VDD-VSS
-0.3
+4.6
V
LCD Driving Voltage
VLCD-VSS
0
20.0
V
Input Voltage
VI
-0.3
VDD+0.3
V
Operating Temp.
TOP
-20
70
°C
Storage Temp.
TSTG
-30
80
°C
Extend temp. type
Date : 2004/8/30
AMPIRE CO., LTD.
3
4
ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Note
----- Electronic Characteristics ----Logic Circuit
Supply Voltage
VDD-VSS
--
2.4
2.8
3.6
V
LCD Driving
Voltage
(FSTN )
VO-VSS
-20 °C
--
13.55
--
V
25 °C
--
12.8
--
70 °C
--
12.13
--
Input Voltage
VIH
--
0.7VDD
--
VDD
V
VIL
--
-0.3
--
0.15
VDD
V
IDD
VDD=
2.8V
--
0.5
0.7
mA
Logic Supply
Current
----- Optical Characteristics ( FSTN ) ----Contrast
CR
25°C
--
7
--
Rise Time
tr
25°C
--
200
--
ms
Fall Time
tf
25°C
--
200
--
ms
Viewing Angle
Range
θf
25°C &
--
40
--
θb
CR≥2
--
30
--
θl
--
35
--
θr
--
35
--
--
64
--
Frame Frequency
fF
25°C
Note 1
Note 2
Note 3
Deg.
Hz
(NOTE 1) Contrast ratio :
CR = (Brightness in OFF state) / (Brightness in ON state)
Date : 2004/8/30
AMPIRE CO., LTD.
4
( NOTE 2 ) Response time :
(NOTE 3) Viewing angle
Date : 2004/8/30
AMPIRE CO., LTD.
5
5
BLOCK DIAGRAM & INTERFACE
C17 DOT 1
C1
C16
C64
C65
128X128 LCD PANEL
C112
C113
C128
S1
COM128/1
COM113/16
S 128
SEG1/128
COM112/17
SEG128/1
C128
COM64/65
COM65/64
COM16/113
(TOP VIEW)
HD66750S
COM1/128
COM17/112
LCD MODULE
PIN 15
PIN 1
No.
Symbol
1
VDD
2~9
D7~D0
10
/RES
11
/CS
Chip select at low
12
A0
Select register Lo:Index/status
13
/WR
Data Write
14
/RD
Data Read
15
VSS
Ground (0V)
Date : 2004/8/30
Function
Power supply for logic circuit
Data bus
Reset pin .Initializes the LSI when low
AMPIRE CO., LTD.
Hi:Control
6
6
TIMING CHARACTERISTICS
Date : 2004/8/30
AMPIRE CO., LTD.
7
80-SYSTEM
Item
Symbol
VDD=1.8to2.4V
Min
Bus cycle time
Max
Min
Max
--
380
--
tcycW
Write
tcycR
Read 800
PWLW
Write120
PWLR
Read 350
PWHW
Write300
PWHRL
Read 300
Enable rise/fall time
tWRr,WRf
--
25
--
25
Address set-up time
(RS, R/W to E)
tAS
50
--
50
--
Address hold time
tAH
20
--
20
--
Write Data set-up time
tDSW
60
--
60
--
Write Data hold time
tH
20
--
20
--
Read Data delay time
tDDR
--
300
--
200
Read Data hold time
tDHR
5
--
5
--
Lo level plusw width
Hi-level pulse width
Date : 2004/8/30
600
VDD=2.4to3.6V
Unit
ns
500
--
70
--
250
--
150
--
150
AMPIRE CO., LTD.
8
Date : 2004/8/30
AMPIRE CO., LTD.
9
7
QUALITY AND RELIABILITY
7.1
TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
7.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal
single sampling plan .
7.3 ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
7.4 APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under flourescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date : 2004/8/30
AMPIRE CO., LTD.
10
7.5
INSPECTION QUALITY CRITERIA
Item
Function
Dimension
Black spots
Black lines
Bubbles in
polarizer
Color
uniformity
Glass
Scratches
Contrast
ratio
Response
time
Viewing
angle
Description
of
defects
Class of
Defects
Major
Major
Minor
Acceptable level
(%)
0.65
1.5
2.5
Minor
2.5
Minor
2.5
Minor
2.5
Obvious visible damage.
Minor
2.5
See note 1
Minor
2.5
See note 2
Minor
2.5
See note 3
Minor
2.5
Short circuit or Pattern cut
Deviation from drawings
Ave . dia . D
area A
area B
Disregard
D≤0.2
3
4
0.2<D≤0.3
2
3
0.3<D≤0.4
0.4<D
0
1
Width W, Length L
A
B
disregard
W≤0.03
3
4
0.03<W≤0.05
1
1
0.05<W≤0.07 , L≤3.0
See line criteria
Average diameter D 0.2 < D < 0.5 mm
for N = 4 , D > 0.5 for N = 1
Rainbow color or newton ring.
Zone A active area
Zone B viewing area
Date : 2004/8/30
AMPIRE CO., LTD.
11
7.6 RELIABILITY
Test Conditions
Test Item
Extend Temp. type
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-20±3°C , t=96 hrs
High Temperature Storage
80±3°C , t=96 hrs
Low Temperature Storage
Thermal Shock Test
Humidity Test
-30±3°C , t=96 hrs
-30°C ~ 25°C ~ 80°C
30 m in. 5 min. 30 min. ( 1 cycle )
Total 5 cycle
40 °C, Humidity 90%, 96 hrs
Note
1,2
1,2
1,2
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
2
Vibration Test (Packing)
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
The ESD test method follow IEC 1000-4-2
Contact discharage: ±4kV, level II
Air discharge ±8kV, level III
ESD Test
2
Cd=150pF, Rd=330Ω
Test times:10 times per each condition, total 40 times.
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2004/8/30
AMPIRE CO., LTD.
12
8
HANDLING PRECAUTIONS
(1) A LCD module is a fragile item and should not be subjected to strong mechanical shocks.
(2) Avoid applying pressure to the module surface. This will distort the glass and cause a
change in color.
(3) Under no circumstances should the position of the bezel tabs or their shape be modified.
(4) Do not modify the display PCB in either shape or positioning of components.
(5) Do not modify or move location of the zebra or heat seal connectors.
(6) The device should only be soldered to during interfacing. Modification to other areas of
the board should not be carried out.
(7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make
contact with the skin. If contact is made rinse immediately.
(8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or
Ethyl alcohol. The use of water, ketone or aromatic is not permitted.
(9) Prior to initial power up input signals should not be applied.
(10) Protect the module against static electricity and observe appropriate anti-static
precautions.
Date : 2004/8/30
AMPIRE CO., LTD.
13
OUTLINE DIMENSION
晶采 光 電 科技
9
Date : 2004/8/30
AMPIRE CO., LTD.
14
晶采 光 電 科技
10 PACKING METHOD
Date : 2004/8/30
AMPIRE CO., LTD.
15