EPCOS B44066T0050E690

Thyristor module TSM-HV50
Series/Type:
TSM
Ordering code: B44066T0050E690
Date:
Version:
August 2006
4
Content of inside pages of data sheet. Data will be automatically entered into frontpage
headlines, headers and footers. Please fill in the table and then change the colour to “White”.
This ensures that the table disappears for the customer pdf.
Identification/Classification 1:
(header 1)
Thyristor module for dynamic PFC
Identification/Classification 2:
(header 2)
Accessories for power factor correction
Ordering code:
B44066T0050E690
Series/Type:
Thyristor module TSM-HV50
Preliminary data (optional):
(if necessary)
Preliminary data
Department:
FK PC PM PFC
Date:
August 2006
© EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0050E690
Thyristor module TSM-HV50
Preliminary data
Charateristics
„ Fast electronically controlled self observing thyristor
switch
„ Usage in dynamic (fast) power factor correction
systems in 690 V grids, neutral conductor required
„ For capacitive loads up to max. 60 kvar at 690 V
„ Micro-processor controlled alignment to tuned or
detuned capacitor branches (up to 14%) for optimized
switching behaviour
„ No system perturbation due to switching operations
(transients)
„ Switching without delay
„ Maintenance-free
„ Long useful service life
„ No noise emission during switching operations
„ Compact module ready for connection
Features
•
Easy installation
-
Mechanical assembly directly on a mounting plate
-
Self check after turn-on of main voltage
-
Optimized switching behaviour to the connected load
(tuned/detuned) via the internal processor
-
Storage of optimized parameters for optimum switching
behaviour
•
Mounting position
-
Upright; minimum 100 mm space on top and below
•
Display and control via LED display
-
Operation
-
Faults
-
Activation
-
Temperature
-
Voltage
-
Capacitor failure
•
Permanent self-monitoring
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2006
Page 2 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0050E690
Thyristor module TSM-HV50
Preliminary data
Technical data
Dimensions
157 x 200 x 195 mm (w x h x d)
Weight
5 kg
Rated voltage
Max. 690 V
Auxiliary supply
230 V AC
Frequency
50/60 Hz
Switching capability
50 A (max. 60 kvar at 690 V)
Activation
10…24 V DC (approx. 20 mA) via terminal clamp,
internally electrically isolated
Switching time
Approx. 5 ms
Reset time
Depending on degree of detuning and dimension of
discharge resistor
Display
Status LED per phase
LED triggering signal
Power circuit
Direct connection 4 pole via busbar (cable lug 25 mm2,
D = 8 mm), connection from the bottom
Power dissipation
PD (in W) = 3.0 x I (in A); at 690 V/50 kvar approx.
125 W thermal
3 x electronic fuse „superfast“ (NH00 AC 690)
50/60 kvar: max.125 A (SIBA Art. No.: 20 209 20-125)
25 kvar: max. 63 A (SIBA Art. No.: 20 209 20- 63)
–10 °C … +55 °C
Fuses (mandatory for protection of components)
Ambient operating temperature at nominal load
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2006
Page 3 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0050E690
Thyristor module TSM-HV50
Preliminary data
Connection diagram: three-phase load at 690 V (standard)
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2006
Page 4 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0050E690
Thyristor module TSM-HV50
Preliminary data
Cautions and warnings
General
• Thyristor modules TSM series may only be used for the purpose they have been designed for.
• Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid
separator device.
• Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled
high current and voltages may occur.
• The devices in operation have to be protected against moisture and dust, sufficient cooling has to
be assured.
Attention
Due to the switching principle of the thyristor module the power capacitors are permanently loaded to
the peak value of the grid voltage (DC voltage) even when switched off. Therefore following rules
have to be obeyed in any case:
• For standard PFC-systems (without reactors) single-phase power capacitors of 400 V nominal
voltage have to be used; for detuned systems with detuning factor 7 % at 690 V, PFC capacitors
of 440 V nominal voltage have to be used. For detuned systems with detuning factor 14 % at 690
V, PFC capacitors of 480 V nominal voltage have to be used.
• In dynamic systems with TSM modules no fast discharge reactors may be used (reactor = DCwise short circuit).
• For standard PFC-systems 3 current limiting reactors are mandatory per thyristor module.
• Thyristor modules in general have to be protected by superfast electronic fuses. Principles for
dimensioning have to be considered. Fuses in the system have to be marked.
• Due to the special switching, the PFC capacitors are fully loaded even when the particular step
has been switched off. Protection against contact has to be guaranteed. Warning signals in the
systems are required.
• Even in switched off state no electrical isolation is achieved for electronic switches. Therefore
parts of the systems may not be touched after switching off the complete system before the
capacitors have been completely discharged.
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR
PHYSICAL INJURY.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual
version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case,
bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications.
Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to
approve our product specifications or request our approval for your specification before ordering.
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2006
Page 5 of 6
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g. installation
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.epcos.com/trademarks.
FK PC PM PFC
August 2006
Page 6 of 6