HONEYWELL CSNF661

Datasheet -- CSNF661
Page 1 of 4
CSNF661
CSN Series closed loop current sensor, measures AC, DC or
impulse current, 100 A nominal, ± 150 amp range, offset
pin, 1000 turn
Representative
photograph, actual
product appearance
may vary.
Due to regional
agency approval
requirements, some
products may not be
available in your area.
Please contact your
regional Honeywell
office regarding your
product of choice.
Features
Current sensing up to 1200 amps
Measures ac, dc and impulse currents
Competitive cost/performance ratio
Rapid response
High overload capability
High level of electrical isolation between primary and
secondary circuits
Industrial operating temperature range
Small size and weight
Typical Applications
Variable speed drives
Overcurrent protection
Ground fault detectors
Current feedback control systems
Robotics
UPS and telecommunication power supplies
Welding power supplies
Automotive - Battery management systems
Wattmeters
Description
The CSN Series of closed loop current sensors are based on the
principles of the Magnetoresistive or Hall effects, and the null
balance or zero magnetic flux method (feedback system). The
magnetic flux in the sensor core is constantly controlled at zero.
The amount of current required to balance zero flux is the
measure of the primary current flowing through the conductor,
multiplied by the ratio of the primary to secondary windings.
This closed loop current is the output from the device and
presents an image of the primary current reduced by the
number of secondary turns at any time. This current can be
expressed as a voltage by passing it through a resistor.
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=current&PN=CSNF661
31/08/2006
Datasheet -- CSNF661
Page 2 of 4
CSNF661
CSN Series closed loop current sensor, measures AC, DC or impulse current, 100 A
nominal, ± 150 amp range, offset pin, 1000 turn
Product Specifications
Sensor Type
Closed Loop Linear
Sensed Current Type
ac or dc
Sensed Current Range
± 150 A
Package Style
Thru Hole PCB Mount
Output Type
Current
Maximum Continuous Current
± 150 A
Supply Current
± 10 mA + output
Supply Voltage
± 12.0 Vdc to ± 15.0 Vdc
Offset Current
< ± 0.2 mA
Offset Current Drift
< ± 0.5 mA
Coil Resistance @ 70 °C
30 Ohm
Response Time
< 0.5 µs
Coil Turns
1000
Output Nominal
100 mA
Operating Temperature Range
-40 °C to 85 °C [-40 °F to 185 °F]
Storage Temperature Range
-40 °C to 90 °C [-40 °F to 194 °F]
Minimum Measuring Resistance
30 Ohm
Maximum Measuring Resistance
80 Ohm
Housing Material
Glass-filled PBT (UL94-V0)
Mounting
PCB on 3 pins
Pinout Style
Offset
Accuracy
± 0.5 %
Availability
Global
Comment
Offset pin version of CSNF161.
UNSPSC Code
411121
UNSPSC Commodity
411121 Transducers
Series Name
CSN Series
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=current&PN=CSNF661
31/08/2006
Datasheet -- CSNF661
Page 3 of 4
CSNF661
CSN Series closed loop current sensor, measures AC, DC or impulse current, 100 A
nominal, ± 150 amp range, offset pin, 1000 turn
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=current&PN=CSNF661
31/08/2006
Datasheet -- CSNF661
Page 4 of 4
CSNF661
CSN Series closed loop current sensor, measures AC, DC or impulse current, 100 A
nominal, ± 150 amp range, offset pin, 1000 turn
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
MISUSE OF DOCUMENTATION
The information presented in this product sheet (or catalog) is for reference only.
DO NOT USE this document as product installation information.
Complete installation, operation and maintenance information is provided in the
instructions supplied with each product.
Failure to comply with these instructions could result in death or serious
injury.
© Copyright Honeywell Inc.1998-2006 All rights reserved.
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=current&PN=CSNF661
31/08/2006