HONEYWELL-ACC 73JA100

Datasheet -- 73JA100
73JA100
73 Series Precision Potentiometer, Wire Wound Element,
Solder lug Terminals, 2 W Power Rating, 100 Ohm
Resistance Value
Representative
photograph, actual
product appearance
may vary.
Features
●
●
Due to regional
agency approval
requirements, some
products may not be
available in your area.
Please contact your
regional Honeywell
office regarding your
product of choice.
●
●
Robust nickel-plated brass shaft and bushings
Wirewound element
Linear taper
10-turn construction
Typical Applications
●
●
Manual controls
Welding and heating
Description
The RA30 Series is a military qualified potentiometer made in
accordance to MIL-R-19 specifications. It offers a 3 watt power
rating and a wirewound element.
73JA100
73 Series Precision Potentiometer, Wire Wound Element, Solder lug Terminals, 2 W
Power Rating, 100 Ohm Resistance Value
Product Specifications
Potentiometer Type
Precision
Element Type
Wire Wound
Terminal Type
Solder lug
Power Rating
2W
Turns
10
Resistance Value
100 Ohm
Resistance Tolerance
±5%
Linearity
± 0.25 %
Bushing Thread
9,53 mm [0.375 in] x 32 NEF-2A
Bushing length
7,92 mm [0.312 in]
Bushing Type
Standard
Shaft Diameter
6,35 mm [0.25 in]
Shaft length
15,88 mm [0.625 in]
file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%2073JA100.htm (1 of 3)10/03/2005 12:30:25 ã
Datasheet -- 73JA100
Shaft Ending
Slotted
Body
22.23 mm [0.875 in] diameter, ± 0.79 mm [0.031 in]
Electrical Taper
Linear
Operating Temperature
-40 °C to 120 °C [-40 °F to 248 °F]
Working Voltage (Max.)
500 V
Rotational Life
50000 cycles
Mechanical Rotation
3600°
Availability
Global
Series Name
73 Series
UNSPSC Code
4111363300
UNSPSC Commodity
4111363300 Potentiometers
73JA100
73 Series Precision Potentiometer, Wire Wound Element, Solder lug Terminals, 2 W
Power Rating, 100 Ohm Resistance Value
73JA100
73 Series Precision Potentiometer, Wire Wound Element, Solder lug Terminals, 2 W
Power Rating, 100 Ohm Resistance Value
file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%2073JA100.htm (2 of 3)10/03/2005 12:30:25 ã
Datasheet -- 73JA100
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
MISUSE OF DOCUMENTATION
●
●
The information presented in this product sheet (or catalog) is for reference only.
DO NOT USE this document as product installation information.
Complete installation, operation and maintenance information is provided in the
instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
© Copyright Honeywell Inc.1998-2004 All rights reserved.