HONEYWELL DC005NDC4

Datasheet -- DC005NDC4
1 of 4
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=pressu...
DC005NDC4
Representative
photograph, actual
product appearance may
vary.
Due to regional agency
approval requirements,
some products may not
be available in your
area. Please contact
your regional Honeywell
office regarding your
product of choice.
Pressure Sensors: Measurement Type: Bidirectional
Gage, Differential; Signal Conditioning: Amplified;
Pressure Range: ± 5.0 in H2O; Port Style: Barbed
Features
Ultra Low Pressure Sensing, down to 1" H20
ASIC Enhanced
Available in Gage and Differential Pressure Ranges
Available in Ratiometric and Regulated
Temperature Compensated over 0 °C to 50 °C [32 °F to
122 °F]
Combined Linearity and Hysteresis error <±0.25% Span
Typical Applications
Medical Instrumentation
HVAC
Environmental Controls
Portable Monitors
Description
The DC pressure sensor combines our SURSENSETM precision
high sensitivity silicon sensing capabilities with the latest in ASIC
technology to produce one of the most precise, reliable pressure
sensors in the market. The SURSENSE technology provides
Dynamic Self Compensation which substantially reduces offset
errors due to changes in temperature, stability to warmup, long
term instability and position sensitivity. When operated with a
fixed 5.0 Vdc supply the DC sensors provides a ratiometric 0.25
Vdc to 4.25 Vdc output (4.0 Vdc span). Regulated voltage units
are also available for applications involving variable supply
voltages (see electrical specifications).
DC005NDC4
Pressure Sensors: Measurement Type: Bidirectional Gage, Differential; Signal
Conditioning: Amplified; Pressure Range: ± 5.0 in H2O; Port Style: Barbed
Product Specifications
Measurement Type
Signal
Conditioning
Pressure Range
Maximum
Overpressure
Supply Voltage
Differential, Bidirectional Gage
Amplified
± 5.0 in H2O
150 in H2O
5.0 Vdc ± 0.1 Vdc
11/1/2005 9:35 PM
Datasheet -- DC005NDC4
2 of 4
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=pressu...
Compensated
Yes
Output Calibration
Yes
Termination
PCB
Port Style
Barbed
Package Style
Honeywell DI-DC
Typical Sensitivity
0.8 V/in H2O
Full Scale Span
± 2.0 V typ.
Null Offset
2.25 Vdc typ.
Offset Position
Sensitivity
Total Error
(% Full Scale)
± 5 mV
± 1.0 % typ., ± 2.0 % max.
(See Note 1)
Accuracy
± 0.25 %
(% Best Fit Straight
(See Note 2)
Line)
Operating
Temperature Range
-25 °C to 85 °C [-13 °F to 185 °F]
Compensated
Temperature Range
0 °C to 50 °C [32 °F to 122 °F]
Storage
Temperature Range
-40 °C to 125 °C [-40 °F to 257 °F]
Media
Compatibility
UNSPSC Code
UNSPSC
Commodity
P2 port: DRY GASES ONLY: Media must be compatible with
epoxy based adhesive. P1 port: Wetted materials; Media must
be compatible with nylon housing, epoxy adhesive and silicon.
411121
411121 Transducers
Note 1
Percentage of Full Scale includes: zero calibration, temperature
effect on zero and span, nonlinearity, hysteresis, repeatability,
and stability over the compensated temperature range.
Note 2
Percentage of Best Fit Straight Line includes: nonlinearity,
hysteresis, and repeatability
Availability
Global
Series Name
DC Series
DC005NDC4
Pressure Sensors: Measurement Type: Bidirectional Gage, Differential; Signal
Conditioning: Amplified; Pressure Range: ± 5.0 in H2O; Port Style: Barbed
11/1/2005 9:35 PM
Datasheet -- DC005NDC4
3 of 4
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=pressu...
DC005NDC4
Pressure Sensors: Measurement Type: Bidirectional Gage, Differential; Signal
Conditioning: Amplified; Pressure Range: ± 5.0 in H2O; Port Style: Barbed
DC005NDC4
Pressure Sensors: Measurement Type: Bidirectional Gage, Differential; Signal
Conditioning: Amplified; Pressure Range: ± 5.0 in H2O; Port Style: Barbed
11/1/2005 9:35 PM
Datasheet -- DC005NDC4
4 of 4
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=pressu...
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
MISUSE OF DOCUMENTATION
The information presented in this product sheet (or catalog) is for reference
only. DO NOT USE this document as product installation information.
Complete installation, operation and maintenance information is provided in
the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious
injury.
© Copyright Honeywell Inc.1998-2004 All rights reserved.
11/1/2005 9:35 PM