MCC MUR605FCT

MCC
omponents
20731 Marilla Street Chatsworth
!"#
$
% !"#
TM
Micro Commercial Components
MUR605FCT
THRU
MUR660FCT
Features
•
•
•
Glass passivated junction
Superfast recovery time for hight efficiency
Low profile package
6 Amp Super Fast
Glass Passivated
Rectifier
50 to 600 Volts
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
MUR605FCT
MUR610FCT
MUR620FCT
MUR640FCT
MUR660FCT
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
MUR605FCT
MUR610FCT
MUR620FCT
MUR640FCT
MUR660FCT
ITO-220AB
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
B
L
M
C
D
A
K
50V
100V
200V
400V
600V
35V
70V
140V
280V
420V
50V
100V
200V
400V
600V
E
F
O
I
J
N
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element 605FCT-620FCT
640FCT
IF(AV)
IFSM
VF
660FCT
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
605FCT- 620FCT
640FCT
660FCT
IR
6A
60A
5.0uA
50uA
35ns
60ns
75ns
PIN 1
TA = 25°C
TA = 100°C
IR=1.0A
PIN 2
PIN 3
8.3ms, half sine
IF=0.5A,
Irr=0.25A
T rr
H H
TA = 75°C
0.975V IFM = 3 A per
1.3V element;
1.7 V TA = 25°C*
G
A
B
C
D
E
F
G
H
I
J
K
L
M
N
INCHES
.583
.606
--.406
.100
.112
.248
.272
--.161
--.071
.512
.543
.100
--.035
--.032
.118
.134
--.189
--.130
.098
.114
MM
14.80
--2.55
6.30
----13.00
15.40
10.30
2.85
6.90
4.10
1.80
13.80
2.55
----3.00
----2.50
0.90
0.80
3.40
4.80
3.30
2.90
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
Revision: 1
www.mccsemi.com
2006/03/20
MCC
MUR605FCT thru MUR660FCT
TM
Figure 1
Typical Forward Characteristics
Figure 2
Micro Commercial Components
Typical Reverse Characteristics
40
1000
640FCT
20
Tc=100°C
605FCT~620FCT
10
100
6.0
4.0
Amps
Tc=75°C
µ Amp
2.0
10
660FCT
1.0
Tc=25°C
0.6
1.0
0.4
0.2
0.1
0.1
0.7
0.9
1.1
1.3
1.5
1.7
1.9
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
100
0
2.1
200
300
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Maximum Non-Repetitive Forward Surge Current
16
12
80
70
8
60
50
6
Amps 40
Amps
30
4
20
10
2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
50
100
125
150
0
0
5
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
10
20
50
100
00
Cycles
175
°C
Revision: 1
2
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
2006/03/20