MICREL SY10E160JZ

12-BIT PARITY
GENERATOR/CHECKER
Micrel, Inc.
FEATURES
The SY10/100E160 are high-speed, 12-bit parity
generator/checkers with differential outputs, for use in
new, high-performance ECL systems. The output Q takes
on a logic HIGH value only when an odd number of inputs
are at a logic HIGH. A logic HIGH on the enable input (EN)
forces the output Q to a logic LOW.
An additional feature of the E160 is the output register.
Two multiplexers and their associated signals control the
register input by providing the option of holding present
data, loading the new parity data or shifting external data
in. To hold the present data, the Hold signal (HOLD) must
be at a logic LOW level. If the HOLD signal is at a logic
HIGH, the data present at the Q output is passed through
the first multiplexer. Taking the Shift signal (SHIFT) to a
logic HIGH will shift the data at the S-IN pin into the output
register. If the SHIFT signal is at a logic LOW, the output
of the first multiplexer is then passed through to the register.
The register itself is clocked on the rising edge of CLK1
or CLK2 (or both). The presence of a logic HIGH on the
reset pin (R) forces the register output Y to a logic LOW.
■
■
■
■
■
■
Output register with Shift/Hold capability
900ps max. D to Q, /Q output
Enable control
Asynchronous Register Reset
Differential outputs
Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E160
■ Available in 28-pin PLCC package
BLOCK DIAGRAM
D0
D1
D2
D3
D4
D5
D6
D7
Q
Q
0
0
MUX
EN
SY100E160
DESCRIPTION
■ Provides odd-HIGH parity of 12 inputs
■ Extended 100E VEE range of –4.2V to –5.5V
D8
D9
D10
D11
SY10E160
SY100E160
SY10E160
D
Y
MUX
1
1
SEL
Y
SEL
R
HOLD
S-IN
SHIFT
CLK1
CLK2
R
M9999-032006
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: March 2006
SY10E160
SY100E160
Micrel, Inc.
Ordering Information(1)
EN
VCCO
D1
D2
D1
D4
D3
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
J28-1
Commercial
SY10E160JC
Sn-Pb
D5
26
18
Q
SY10E160JC
D6
D7
VEE
27
17
SY10E160JCTR(2)
J28-1
Commercial
SY10E160JC
Sn-Pb
15
Q
VCC
Y
SY100E160JC
J28-1
Commercial
SY100E160JC
Sn-Pb
14
Y
SY100E160JCTR(2)
J28-1
Commercial
SY100E160JC
Sn-Pb
VCCO
NC
SY10E160JZ(3)
J28-1
Commercial
SY10E160JZ with
Matte-Sn
Pb-Free bar-line indicator
SY10E160JZTR(2, 3)
J28-1
Commercial
SY10E160JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100E160JZ(3)
J28-1
Commercial
SY100E160JZ with
Matte-Sn
Pb-Free bar-line indicator
SY100E160JZTR(2, 3)
J28-1
Commercial
SY100E160JZ with
Matte-Sn
Pb-Free bar-line indicator
28
16
PLCC
TOP VIEW
J28-1
1
D8
D9
2
3
13
D10
4
12
9
10 11
CLK2
R
8
CLK1
7
S-IN
SHIFT
6
D11
HOLD
5
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
SY10E160
SY100E160
Micrel, Inc.
PIN NAMES
TRUTH TABLE
Pin
Function
D0–D11
Data Inputs
S-IN
Serial Data Input
EN
Enable, active LOW
HOLD
Hold, active LOW
SHIFT
Shift, active HIGH
CLK1, CLK2
Clock Inputs
R
Reset Input
Q, Q
Direct Output
Y, Y
Register Output
VCCO
VCC to Output
Number of
HIGH Inputs
Output
Q
Even
LOW
Odd
HIGH
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
IIH
IEE
Parameter
TA = +25°C
Min. Typ. Max. Min. Typ.
Input HIGH Current
CLK1, CLK2
R
All Other Inputs
TA = +85°C
Max. Min. Typ.
Max.
—
—
—
—
—
—
200
300
150
—
—
—
—
—
—
200
300
150
—
—
—
—
—
—
200
300
150
—
—
82
82
98
98
—
—
82
82
98
98
—
—
82
94
98
113
Power Supply Current
10E
100E
M9999-032006
[email protected] or (408) 955-1690
3
Unit
Condition
µA
—
mA
—
SY10E160
SY100E160
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
tPD
tS
tH
tr
tf
Parameter
TA = +25°C
Min. Typ. Max. Min. Typ.
TA = +85°C
Max. Min. Typ.
Max.
Propagation Delay to Output
D to Q
EN to Q
CLK to Y
R to Y
400
300
275
275
650
550
500
500
950
750
700
725
400
300
275
275
650
550
500
500
950
750
700
725
400
300
275
275
650
550
500
500
950
750
700
725
Set-up Time
D
HOLD
S-IN
SHIFT
1200
600
350
500
900
300
150
250
—
—
—
—
1200
600
350
500
900
300
150
250
—
—
—
—
1200
600
350
500
900
300
150
250
—
—
—
—
Hold Time
D
HOLD
S-IN
SHIFT
–400
100
300
200
–900
–300
–150
–250
—
—
—
—
–400
100
300
200
–900
–300
–150
–250
—
—
—
—
–400
100
300
200
–900
–300
–150
–250
—
—
—
—
300
450
650
300
450
650
300
450
650
Rise/Fall Time
20% to 80%
M9999-032006
[email protected] or (408) 955-1690
4
Unit
Condition
ps
—
ps
—
ps
—
ps
—
SY10E160
SY100E160
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690
5