MICREL SY10E416JI

■ Differential D and Q
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E416 are 5-bit differential line receiving
devices. The 2.0GHz of bandwidth provided by the high
frequency outputs make the devices ideal for buffering
of very high speed oscillators.
A VBB pin is available to AC couple an input signal to
the devices.
The design incorporates two stages of gain internal to
the devices, making them an excellent choice for use in
high bandwidth amplifier applications.
VBB output for single-ended use
600ps max. propagation delay
High frequency outputs
2 stages of gain
Internal 75KΩ input pull-down resistors
Fully compatible with Motorola 10E/100E416
Available in 28-pin PLCC package
PIN NAMES
BLOCK DIAGRAM
Pin
D0
D0
SY100E416
DESCRIPTION
FEATURES
■
■
■
■
■
■
■
SY10E416
SY100E416
SY10E416
QUINT DIFFERENTIAL
LINE RECEIVER
Micrel, Inc.
Q0
Q0
D1
D0
Q1
Q1
D2
D2
Q2
Q2
D3
D3
Q3
Q3
D4
D4
Q4
Q4
Function
D[0:4], D[0:4]
Differential Data Inputs
Q[0:4], Q[0:4]
Differential Data Outputs
VCCO
VCC to Output
VBB
M9999-032206
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: March 2006
SY10E416
SY100E416
Micrel, Inc.
Ordering Information(1)
Q4
Q4
VCCO
D3
D4
D4
VCCO
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
J28-1
Industrial
SY10E416JI
Sn-Pb
D3
26
18
Q3
SY10E416JI
D2
27
17
Q3
D2
SY10E416JITR(2)
J28-1
Industrial
SY10E416JI
Sn-Pb
28
16
VCC
VEE
VBB
1
15
Q2
SY100E416JI
J28-1
Industrial
SY100E416JI
Sn-Pb
2
J28-1
Industrial
SY100E416JI
Sn-Pb
D0
3
13
Q2
VCCO
SY100E416JITR(2)
SY10E416JC
J28-1
Commercial
SY10E416JC
Sn-Pb
D0
4
12
Q1
SY10E416JCTR(2)
J28-1
Commercial
SY10E416JC
Sn-Pb
SY100E416JC
J28-1
Commercial
SY100E416JC
Sn-Pb
SY100E416JCTR(2)
J28-1
Commercial
SY100E416JC
Sn-Pb
SY10E416JY(3)
J28-1
Industiral
SY10E416JY with
Pb-Free bar-line indicator
Matte-Sn
SY10E416JYTR(2, 3)
J28-1
Industrial
SY10E416JY with
Pb-Free bar-line indicator
Matte-Sn
SY100E416JY(3)
J28-1
Industrial
SY100E416JY with
Pb-Free bar-line indicator
Matte-Sn
SY100E416JYTR(2, 3)
J28-1
Industrial
SY100E416JY with
Pb-Free bar-line indicator
Matte-Sn
TOP VIEW
PLCC
J28-1
8
9
10 11
VCCO
Q1
7
VCCO
Q0
Q0
D1
6
D1
5
14
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032206
[email protected] or (408) 955-1690
2
SY10E416
SY100E416
Micrel, Inc.
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
VBB
TA = +25°C
Min.
Typ.
Output Reference Voltage
10E
100E
–1.38
–1.38
—
—
—
—
150
—
—
150
—
—
135
135
162
162
—
—
135
135
50
—
—
50
–1.5
—
0
–1.5
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
VPP (DC)
Input Sensitivity
VCMR
Common Mode Range
Max.
Min.
–1.27 –1.35
–1.26 –1.38
Typ.
TA = +85°C
Parameter
—
—
Max.
Min.
–1.25 –1.31
–1.26 –1.38
Typ. Max.
Unit
Condition
V
—
µA
—
mA
—
—
—
–1.19
–1.26
—
—
150
162
162
—
—
135
155
162
186
—
—
50
—
—
mV
1
—
0
–1.5
—
0
V
2
Notes:
1. Differential input voltage required to obtain a full ECL swing on the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
tPD
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min. Typ.
Max. Unit
Propagation Delay to Output
D (Diff)
D (SE)
250
200
350
350
500
550
250
200
350
350
500
550
250
200
350
350
500
550
—
50
—
—
50
—
—
50
—
Condition
ps
—
ps
1
ps
2
tskew
Within-Device Skew
tskew
Duty Cycle Skew, tPLH–tPHL
VPP (AC)
Minimum Input Swing
150
—
—
150
—
—
150
—
—
mV
3
tr
tf
Rise/Fall Time
20–80%
100
200
350
100
200
350
100
200
350
ps
—
±10
±10
±10
Notes:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Duty cycle skew defined only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the outputs.
3. Minimum input swing for which AC parameters are guaranteed.
M9999-032206
[email protected] or (408) 955-1690
3
SY10E416
SY100E416
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032206
[email protected] or (408) 955-1690
4