MICREL SY100S891JZ

Micrel, Inc.
5-BIT REGISTERED
TRANSCEIVER
FEATURES
SY100S891
SY100S891
DESCRIPTION
25Ω cut-off bus outputs
50Ω receiver outputs
Transmit and receive registers with separate clocks
1500ps max. delay from CLK1 to Bus Outputs (BUS)
1500ps max. delay from CLK2 to Receiver Outputs (Q)
Individual bus enable pins
Internal 75KΩ input pull-down resistors
Voltage and temperature compensation for improved
noise immunity
■ Industry standard 100K ECL levels
■ Extended supply voltage option:
VEE = –4.2V to –5.5V
■ Available in 28-pin PLCC package
■
■
■
■
■
■
■
■
The SY100S891 is a 5-bit registered transceiver
containing five bus transceivers with both transmit and
receive registers. The bus outputs (BUS0 – BUS4) are
specified for driving a 25 ohm bus and the receive outputs
(Q0 – Q4) are specified for driving a 50 ohm line. The
bus outputs have a normal high level output voltage and
a normal low level output voltage when the bus enable
(BUSEN0 – BUSEN4) is high. However, the output is
switched to a cut-off level when a bus-enable is low.
This cut-off level is sufficiently low that a relatively high
impedance is presented to the bus in order to minimize
reflections. There is one bus-enable for each bus driver;
a clock (CLK1) which is common to all five bus driver
registers; and a separate clock (CLK2) which is common
to all five receive registers. Data at the D inputs is clocked
to the Bus register by a positive transition of CLK1 and
data on the bus is clocked into the Receiver register by
a positive transition of CLK2. A high on the Master Reset
clears all registers.
PIN NAMES
Pin
M9999-032406
[email protected] or (408) 955-1690
Function
BUSEN0–4
Bus Enable Inputs
D0 – D4
Data Inputs
CLK1
Bus Driver Clock Input
CLK2
Receive Register Clock
MR
Master Reset
Q0 – Q4
Bus Receive Outputs
BUS0–4
Bus Outputs
Rev.: F
1
Amendment: /0
Issue Date: March 2006
Micrel, Inc.
SY100S891
Ordering Information
Q4
BUS
4
VCCA
D3
BUSEN3
D4
BUSEN4
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
MR
26
18
Q3
CLK2
27
17
CLK1
VEE
28
16
BUS3
VCC
15
Q2
14
TOP VIEW
PLCC
J28-1
1
D2
BUSEN2
2
3
13
BUS2
VCCA
D1
4
12
Q1
5
6
7
8
9
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY100S891JC
J28-1
Commercial
SY100S891JC
Sn-Pb
SY100S891JCTR(1)
J28-1
Commercial
SY100S891JC
Sn-Pb
SY100S891JZ(2)
J28-1
Commercial
SY100S891JC with
Pb-Free bar-line indicator
Matte-Sn
SY100S891JZTR(1, 2)
J28-1
Commercial
SY100S891JC with
Pb-Free bar-line indicator
Matte-Sn
10 11
BUS1
Q0
BUS0
VCCA
BUSEN0
BUSEN1
D0
Notes:
1. Tape and Reel.
2. Pb-Free package is recommended for new designs.
28-Pin PLCC (J28-1)
M9999-032406
[email protected] or (408) 955-1690
2
Micrel, Inc.
SY100S891
BLOCK DIAGRAM
D0
25Ω CUTOFF
D Q
R C
D Q
R C
50Ω
BUS 0
Q0
BUSEN0
D1
25Ω CUTOFF
D Q
R C
D Q
R C
50Ω
BUS 1
Q1
BUSEN1
D2
25Ω CUTOFF
D Q
R C
D Q
R C
50Ω
BUS 2
Q2
BUSEN2
D3
25Ω CUTOFF
D Q
R C
D Q
R C
BUSEN3
D4
25Ω CUTOFF
D Q
R C
D Q
R C
BUSEN4
MR
CLK 1
CLK 2
M9999-032406
[email protected] or (408) 955-1690
50Ω
3
50Ω
BUS 3
Q3
BUS 4
Q4
Micrel, Inc.
SY100S891
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
Parameter
Min.
Typ.
Max.
Unit
–2160
–2100
mV
VIN = VIH (Max.) or VIL (Min.)
VIN = VIH (Max.) or VIL (Min.)
VCUT
Cut-off Bus Output Voltage
–2200
VOH
Output HIGH Voltage Bus
–1025
–955
–880
mV
VOL
Output LOW Voltage Bus
–1810
–1705
–1620
mV
VOHA
Output HIGH Voltage Bus
–1035
—
—
mV
VOLA
Output LOW Voltage Bus
—
—
–1610
mV
Condition
Loading with
25Ω to –2.20V
Loading with
25Ω to –2.0V
VIN = VIH (Min.) or VIL (Max.)
VOH
Output HIGH Voltage Receiver
–1025
–955
–880
mV
VOL
Output LOW Voltage Receiver
–1810
–1705
–1620
mV
VOHA
VOLA
Output HIGH Voltage Receiver
Output LOW Voltage Receiver
–1035
—
—
—
—
–1610
mV
mV
VIH
Input HIGH Voltage
–1165
—
–880
mV
Guaranteed HIGH Signal for All Inputs
VIL
Input LOW Voltage
–1810
—
–1475
mV
Guaranteed LOW Signal for All Inputs
IIL
Input LOW Current
0.5
—
—
µA
VIN = VIL (Min.)
IIH
Input High Current
—
—
150
µA
VIN = VIH (Max.)
IEE
Power Supply Current
–216
—
—
mA
Inputs Open
CIN
Input Pin Capacitance
—
4
—
pF
COUT
Output Pin Capacitance
—
5
—
pF
M9999-032406
[email protected] or (408) 955-1690
4
VIN = VIH (Max.) or VIL (Min.)
Loading with
50Ω to –2.0V
VIN = VIH (Min.) or VIL (Max.)
Micrel, Inc.
SY100S891
AC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
tPLH
tPHL
Propagation
CLK1 to Bus
Delay(1)
600
1000
1500
600
1000
1500
600
1000
1500
ps
tPLH
tPHL
Propagation Delay(2)
CLK2 to Q
500
800
1200
500
800
1200
500
800
1200
ps
tPLH
tPHL
Propagation Delay(1)
BUSEN to Bus
500
800
1200
500
800
1200
500
800
1200
ps
tPLH
tPHL
Propagation Delay(1)
Master Reset to Bus
600
1000
1500
600
1000
1500
600
1000
1500
ps
tPLH
tPHL
Propagation Delay(2)
Master Reset to Q
500
800
1200
500
800
1200
500
800
1200
ps
tS
Set-up Time
Bus Wrt CLK2
D Wrt CLK1
—
—
—
—
400
400
—
—
—
—
400
400
—
—
—
—
400
400
—
—
1000
—
—
1000
—
—
1000
—
—
—
—
400
400
—
—
—
—
400
400
—
—
—
—
400
400
Output Rise Time
Bus(3)
Q(4)
500
300
—
—
1000
900
500
300
—
—
1000
900
500
300
—
—
1000
900
Output Fall Time
Bus(3)
Q(4)
500
300
—
—
1000
900
500
300
—
—
1000
900
500
300
—
—
1000
900
—
100
—
—
100
—
—
100
—
tREL
Master Reset
Release Time
tH
Hold Time
Bus Wrt CLK2
D Wrt CLK1
tr
tf
tskew
Skew (Maximum
difference between
slowest and fastest path)
ps
ps
ps
ps
Notes:
1. Loaded with 25Ω to –2.0V
2. Loaded with 50Ω to –2.0V
3. 25Ω Load
4. 50Ω Load
M9999-032406
[email protected] or (408) 955-1690
ps
5
ps
Condition
Micrel, Inc.
SY100S891
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032406
[email protected] or (408) 955-1690
6