XPPOWER VEH60US12

ACDC
60 Watts
VEH Series
xppower.com
•
Energy Efficiency Level V, ≥15 V
•
CEC 2008 & EISA 2007 Compliant
•
China Compulsory Certfication (CCC) Qualified
•
Single Outputs from 12 V to 30 V
•
Optional Inlet Connectors
•
No Load Input Power <0.5 W
•
High Power Density
B R A N D
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
General
•
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
1.7 A max
50 A max at 230 VAC, cold start at 25 °C
<1 mA at 240 VAC/50 Hz
EN61000-3-2, class A
<0.5 W
Internal T3.15A/250 V fuse in line
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
Start Up Delay
Start Up Rise Time
Transient Response
•
•
•
•
•
•
•
Line Regulation
Load Regulation
Ripple & Noise
•
•
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
Coefficient
•
See table
±5% at 50% load
No minimum load requirement
8 ms min at 115 VAC, full load
3 s max
8 ms typical
4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
±0.5% max
±5% max
200 mv pk-pk max, 20 MHz bandwidth
(see note 1)
See table
110 -180%
Continuous (hiccup/trip & restart mode
with auto recovery)
±0.04%/˚C
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
• See table
• Level V ≥15 V
• 3000 VAC Input to Output,
1500 VAC Input to Ground.
• 60 kHz ±10 kHz
• >700 kHrs to Bell Core iss. 6
Environmental
Operating Temperature • 0 ˚C to +60 ˚C derate linearly from 100%
load at +40 ˚C to 50% load at +60 ˚C
Storage Temperature • -20 ˚C to +85 ˚C
Operating Humidity
• 5% to 90% RH non-condensing
Storage Humidity
• 5% to 95% RH non-condensing
Shock
• 6 random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
•
•
•
•
•
•
•
Conducted Immunity
Magnetic Field
Dips & Interruptions
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2 class A
EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria B
EN61000-4-6, level 2 Perf Criteria A
EN61000-4-8, 3 A/m Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
IEC60950-1, EN60950-1, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, Approved as Limited Power
Source
Output Power
60
60
60
60
60
W
W
W
W
W
Output Voltage(5)
12.0
15.0
19.0
24.0
30.0
V
V
V
V
V
Output Current
5.00
4.00
3.16
2.50
2.00
A
A
A
A
A
OVP Setting(2)
16.0
18.0
25.0
30.0
36.0
V
V
V
V
V
Efficiency(3)
85%
87%
87%
87%
87%
Model Number(4)
VEH60US12†^
VEH60US15(6)†^
VEH60US19(6)
VEH60US24(6)†^
VEH60US30(6)
Notes
1. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
2. Typical values.
3. Average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input.
4. For optional IEC320-C6 input connector, add suffix ‘C6’ to end of the part number, e.g. VEH60US24C6. Contact sales for details.
5. Other voltages between 12 V and 30 V available on request, contact sales for details.
6. Energy Efficiency Level V.
† Available from Farnell & element14. See page 28.
^ Available from Newark. See page 28.
Mechanical Details
Cable length: 48” ±2” (1220 mm ±50 mm)
IEC320-C14
2.09
(53.0)
1.57
(40.0)
0.91
(23.0)
1.18 ±0.2
(30.0,
±5.0)
0.43
(11.0)
0.4
(10.0)
4.62
(117.4)
Optional IEC320-C6
1.26
(32.0)
0.91
(23.0)
Power Cord for C14 inlet, Order Part:
UK - UK-MAINS-IEC
European - EU-MAINS-IEC
US - US-MAINS-IEC
Power Cord for C6 inlet, Order Part:
UK - UK-MAINS-5
European - EU-MAINS-5
US - US-MAINS-5
Notes
1.
2.
3.
4.
All dimensions are shown in inches (mm), Tolerance is 0.04” (±1.0) max except output lead.
Weight: 0.76 lbs (345 g) approx.
Output connector is barrel type with 11 mm length, 5.5 mm dia. outer, 2.5 mm dia. inner with center + and outer shell - polarity.
Optional output connectors available.
04-Oct-11
ACDC
VEH60
Models and Ratings