CUI VWRBT2-D12-S5-SMT

date
10/14/2011
page
1 of 5
SERIES: VWRBT2 │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
2 W isolated output
wide input (2:1)
industry standard 16 pin SMT package style
single regulated outputs
1,500 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 80%
RoHS
input
voltage
output
voltage
output
power
ripple
and noise
efficiency
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
VWRBT2-D12-S3.3-SMT
9 ~ 18
3.3
50
500
1.65
150
70
VWRBT2-D12-S5-SMT
9 ~ 18
VWRBT2-D12-S9-SMT
9 ~ 18
5
40
400
2
150
74
9
22
222
2
150
76
VWRBT2-D12-S12-SMT
VWRBT2-D12-S15-SMT
9 ~ 18
12
16
167
2
150
78
9 ~ 18
15
13
133
2
150
79
VWRBT2-D24-S3.3-SMT
18 ~ 36
3.3
50
500
1.65
150
72
VWRBT2-D24-S5-SMT
18 ~ 36
5
40
400
2
150
76
VWRBT2-D24-S9-SMT
18 ~ 36
9
22
222
2
150
78
VWRBT2-D24-S12-SMT
18 ~ 36
12
16
167
2
150
80
VWRBT2-D24-S15-SMT
18 ~ 36
15
13
133
2
150
80
MODEL
Notes:
output
current
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
cui.com
CUI Inc │ SERIES: VWRBT2 │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2011 │ page 2 of 5
INPUT
parameter
conditions/description
operating input voltage
12 V input
24 V input
min
typ
max
units
9
18
12
24
18
36
Vdc
Vdc
OUTPUT
parameter
conditions/description
typ
max
units
line regulation
measured from low line to high line
min
±0.2
±0.5
%
load regulation
measured from 10% to 100% full load
±0.5
±1
%
±3
voltage accuracy
refer to recommended circuit
±1
switching frequency
100% load, nominal input voltage
300
temperature coefficient
%
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
tested for 1 minute, at 1 mA max.
1,500
Vdc
insulation resistance
at 500 Vdc
1,000
MΩ
RoHS compliant
yes
1,000,000
hours
MTBF
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-40
typ
85
°C
storage temperature
-55
125
°C
95
%
245
°C
storage humidity
temperature rise
100% load
reflow soldering temperature
for 10 seconds
15
cui.com
°C
CUI Inc │ SERIES: VWRBT2 │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2011 │ page 3 of 5
DERATING CURVE
Load (%)
RECOMMENDED REFLOW PROFILE
Operating Temp. (°C)
MECHANICAL
parameter
conditions/description
dimensions
0.94 x 0.71 x 0.32 inch (23.9 x 18.1 x 8.0 mm)
min
case material
UL94V-0 epoxy resin
typ
weight
max
units
5.2
g
1.02[0.040]
0.50[0.020]
23.86[0.939]
3.04[0.120]
15.24[0.600]
2.54[0.100]
PIN
Function
1
GND
7
NC
8
NC
+Vo
9
10
1
7
8
13.7 0[0 .539 ]
( Top View)
1 8.10 [0.7 13]
10 9
18.10[0.713]
10 9
1
7
8
+Vin
NC: No conne ction
2.54[0.100]
No te:
Un it :m m [in ch]
P in sectio n toler ances:±0 .10m m [ ±0.00 4inch]
Gener al t olera nces:±0. 25m m [ ±0.01 0inch]
5
0.25[0.010]
16
0V
16
16
2.5 4[0 .100 ]
PIN CONNECTIONS
2.1 0[0. 083 ]
(Side View)
1 7.22 [0.6 78]
8 .00[0 .31 5]
7 .50 [0.29 5]
MECHANICAL DRAWING
1.40±0.20
[0.055±0.008]
cui.com
1.00[0.039]
CUI Inc │ SERIES: VWRBT2 │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2011 │ page 4 of 5
APPLICATION NOTES
All of the VWRBT2-SMT Series have been tested according to the following recommended testing circuit before leaving the factory. This
series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase capacitance
properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1).
Figure 1
+Vin
+Vout
Cin
DC
Table 1
DC
-Vin
-Vout
Single Vout
(Vdc)
Cout
(μF)
3.3
2,200
5
1,000
9
680
12
470
15
330
1.
Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded. The
minimum output load must be at least 10%. If the actual load is less than 10%, the output ripple may increase sharply while the
efficiency and reliability will greatly reduce.
2.
Recommended Circuit
It is best to test with full load and not to test without load. To further reduce output ripple, you may increase the external capacitor,
choose a capacitor with low ESR.
3.
Input Current
Nominal input voltage range. The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC
module (Figure 2)
IP≤1.4*Iin-max
Figure 2
4.
No parallel connection or plug and play
cui.com
CUI Inc │ SERIES: VWRBT2 │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2011 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
05/12/2008
1.01
updated to new template
10/04/2011
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.