SPANSION MBM29F016A-90

TM
SPANSION Flash Memory
Data Sheet
September 2003
TM
This document specifies SPANSION memory products that are now offered by both Advanced Micro Devices and
Fujitsu. Although the document is marked with the name of the company that originally developed the specification,
these products will be offered to customers of both AMD and Fujitsu.
Continuity of Specifications
There is no change to this datasheet as a result of offering the device as a SPANSION
revisions will occur when appropriate, and changes will be noted in a revision summary.
TM
product. Future routine
Continuity of Ordering Part Numbers
AMD and Fujitsu continue to support existing part numbers beginning with "Am" and "MBM". To order these
products, please use only the Ordering Part Numbers listed in this document.
For More Information
Please contact your local AMD or Fujitsu sales office for additional information about SPANSION
solutions.
TM
memory
FUJITSU SEMICONDUCTOR
DATA SHEET
DS05-20844-5E
FLASH MEMORY
CMOS
16M (2M × 8) BIT
MBM29F016A-70/-90/-12
■ GENERAL DESCRIPTION
The MBM29F016A is a 16 M-bit, 5.0 V-Only Flash memory organized as 2 M bytes of 8 bits each. The 2 M bytes
of data is divided into 32 sectors of 64 K bytes for flexible erase capability. The 8 bit of data will appear on DQ7
to DQ0. The MBM29F016A is offered in a 48-pin TSOP(1) package. This device is designed to be programmed
in-system with the standard system 5.0 V VCC supply. A 12.0 V VPP is not required for program or erase operations.
The device can also be reprogrammed in standard EPROM programmers.
The standard MBM29F016A offers access times between 70 ns and 120 ns allowing operation of high-speed
microprocessors without wait states. To eliminate bus contention the device has separate chip enable (CE), write
enable (WE), and output enable (OE) controls.
(Continued)
■ PRODUCT LINE UP
Part No.
MBM29F016A
VCC = 5.0 V ±5%
-70
—
—
VCC = 5.0 V ±10%
—
-90
-12
Max Address Access Time (ns)
70
90
120
Max CE Access Time (ns)
70
90
120
Max OE Access Time (ns)
40
40
50
Ordering Part No.
■ PACKAGES
48-pin Plastic TSOP(1)
48-pin Plastic TSOP(1)
Marking Side
Marking Side
(FPT-48P-M19)
(FPT-48P-M20)
MBM29F016A-70/-90/-12
(Continued)
The MBM29F016A is command set compatible with JEDEC standard E2PROMs. Commands are written to the
command register using standard microprocessor write timings. Register contents serve as input to an internal
state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses
and data needed for the programming and erase operations. Reading data out of the device is similar to reading
from 12.0 V Flash or EPROM devices.
The MBM29F016A is programmed by executing the program command sequence. This will invoke the Embedded
Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies
proper cell margin. Each sector can be programmed and verified in less than 0.5 seconds. Erase is accomplished
by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal
algorithm that automatically preprograms the array if it is not already programmed before executing the erase
operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin.
This device also features a sector erase architecture. The sector erase mode allows for sectors of memory to
be erased and reprogrammed without affecting other sectors. A sector is typically erased and verified within 1
second (if already completely preprogrammed). The MBM29F016A is erased when shipped from the factory.
The MBM29F016A device also features hardware sector group protection. This feature will disable both program
and erase operations in any combination of eight sector groups of memory. A sector group consists of four
adjacent sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31.
Fujitsu has implemented an Erase Suspend feature that enables the user to put erase on hold for any period of
time to read data from or program data to a non-busy sector. Thus, true background erase can be achieved.
The device features single 5.0 V power supply operation for both read and program functions. Internally generated
and regulated voltages are provided for the program and erase operations. A low VCC detector automatically
inhibits write operations during power transitions. The end of program or erase is detected by Data Polling of
DQ7, or by the Toggle Bit I feature on DQ6 or RY/BY output pin. Once the end of a program or erase cycle has
been completed, the device automatically resets to the read mode.
The MBM29F016A also has a hardware RESET pin. When this pin is driven low, execution of any Embedded
Program or Embedded Erase operations will be terminated. The internal state machine will then be reset into
the read mode. The RESET pin may be tied to the system reset circuity. Therefore, if a system reset occurs
during the Embedded Program or Embedded Erase operation, the device will be automatically reset to a read
mode. This will enable the system microprocessor to read the boot-up firmware from the Flash memory.
Fujitsu's Flash technology combines years of EPROM and E2PROM experience to produce the highest levels
of quality, reliability, and cost effectiveness. The MBM29F016A memory electrically erases all bits within a sector
simultaneously via Fowler-Nordheim tunneling. The bytes are programmed one byte at a time using the EPROM
programming mechanism of hot electron injection.
2
MBM29F016A-70/-90/-12
■ FEATURES
• Single 5.0 V read, write, and erase
Minimizes system level power requirements
• Compatible with JEDEC-standard commands
Pinout and software compatible with single-power supply Flash
Superior inadvertent write protection
• 48-pin TSOP(1) (Package Suffix: PFTN-Normal Bend Type, PFTR-Reverse Bend Type)
• Minimum 100,000 write/erase cycles
• High performance
70 ns maximum access time
• Sector erase architecture
Uniform sectors of 64 K bytes each
Any combination of sectors can be erased. Also supports full chip erase.
• Embedded Erase™* Algorithms
Automatically pre-programs and erases the chip or any sector
• Embedded Program™* Algorithms
Automatically programs and verifies data at specified address
• Data Polling and Toggle Bit feature for detection of program or erase cycle completion
• Ready/Busy output (RY/BY)
Hardware method for detection of program or erase cycle completion
• Low VCC write inhibit ≤ 3.2 V
• Hardware RESET pin
Resets internal state machine to the read mode
• Erase Suspend/Resume
Supports reading or programming data to a sector not being erased
• Sector group protection
Hardware method that disables any combination of sector groups from write or erase operation (a sector group
consists of 4 adjacent sectors of 64 K bytes each)
• Temporary sector groups unprotection
Temporary sector unprotection via the RESET pin
* : Embedded EraseTM and Embedded ProgramTM are trademarks of Advanced Micro Devices, Inc.
3
MBM29F016A-70/-90/-12
■ PIN ASSIGNMENTS
TSOP(1)
N.C.
N.C.
A19
A18
A17
A16
A15
A14
A13
A12
CE
VCC
N.C.
RESET
A11
A10
A9
A8
A7
A6
A5
A4
N.C.
N.C.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
(Marking Side)
MBM29F016A
Normal Bend
N.C.
N.C.
A20
N.C.
WE
OE
RY/BY
DQ7
DQ6
DQ5
DQ4
VCC
VSS
VSS
DQ3
DQ2
DQ1
DQ0
A0
A1
A2
A3
N.C.
N.C.
(FPT-48P-M19)
N.C.
N.C.
A4
A5
A6
A7
A8
A9
A10
A11
RESET
N.C.
VCC
CE
A12
A13
A14
A15
A16
A17
A18
A19
N.C.
N.C.
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
(Marking Side)
MBM29F016A
Reverse Bend
(FPT-48P-M20)
■ PIN DESCRIPTIONS
Pin
4
Function
A20 to A0
Address Inputs
DQ7 to DQ0
Data Inputs/Outputs
CE
Chip Enable
OE
Output Enable
WE
Write Enable
RY/BY
Ready/Busy Output
RESET
Hardware Reset Pin/Sector Protection Unlock
N.C.
No Internal Connection
VSS
Device Ground
VCC
Device Power Supply
N.C.
N.C.
A3
A2
A1
A0
DQ0
DQ1
DQ2
DQ3
VSS
VSS
VCC
DQ4
DQ5
DQ6
DQ7
RY/BY
OE
WE
N.C.
A20
N.C.
N.C.
MBM29F016A-70/-90/-12
■ BLOCK DIAGRAM
DQ7 to DQ0
VCC
VSS
RY/BY
Buffer
RY/BY
Erase Voltage
Generator
WE
Input/Output
Buffers
State
Control
RESET
Command
Register
Program Voltage
Generator
Chip Enable
Output Enable
Logic
CE
OE
STB
Low VCC Detector
Timer for
Program/Erase
Address
Latch
STB
Data Latch
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
A20 to A0
■ LOGIC SYMBOL
21
A20 to A0
8
DQ7 to DQ0
CE
OE
WE
RESET
RY/BY
5
MBM29F016A-70/-90/-12
■ FLEXIBLE SECTOR-ERASE ARCHITECTURE
MBM29F016A User Bus Operations Table
OE
WE
A0
A1
A6
CE
Operation
A9
DQ7 to DQ0 RESET
Auto-Select Manufacturer Code *1
L
L
H
L
L
L
VID
Code
H
Auto-Select Device Code *1
L
L
H
H
L
L
VID
Code
H
Read *
L
L
H
A0
A1
A6
A9
DOUT
H
Standby
H
X
X
X
X
X
X
High-Z
H
Output Disable
L
H
H
X
X
X
X
High-Z
H
Write (Program/Erase)
L
H
L
A0
A1
A6
A9
DIN
H
L
VID
X
X
X
VID
X
H
L
L
H
L
H
L
VID
Code
H
Temporary Sector Group Unprotection
X
X
X
X
X
X
X
X
VID
Reset (Hardware)
X
X
X
X
X
X
X
High-Z
L
3
Enable Sector Group Protection *2
Verify Sector Group Protection *
2
Legend: L = VIL, H = VIH, X = VIL or VIH,
= Pulse Input. See DC Characteristics for voltage levels.
*1 : Manufacturer and device codes may also be accessed via a command register write sequence. Refer to
“MBM29F016A Command Definitions Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”.
*2 : Refer to the section on Sector Group Protection.
*3 : WE can be VIL if OE is VIL, OE at VIH initiates the write operations.
6
MBM29F016A-70/-90/-12
Command
Sequence
Bus
Write
Cycles
Req'd
MBM29F016A Command Definitions Table
First Bus Second Bus Third Bus Fourth Bus
Fifth Bus
Sixth Bus
Write Cycle Write Cycle Write Cycle Read/Write
Write
Cycle
Write
Cycle
Cycle
Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/Reset*1
1
XXXh
F0h
—
—
—
—
—
—
—
—
—
—
Reset/Read*1
3
555h
AAh
2AAh
55h
555h
F0h
RA*2
RD*2
—
—
—
—
Autoselect
3
555h
AAh
2AAh
55h
555h
90h
IA*2
ID*2
—
—
—
—
Byte Program
4
555h
AAh
2AAh
55h
555h
A0h
PA
PD
—
—
—
—
Chip Erase
6
555h
AAh
2AAh
55h
555h
80h
555h
AAh
2AAh
55h
555h
10h
Sector Erase
6
555h
AAh
2AAh
55h
555h
80h
555h
AAh
2AAh
55h
SA
30h
Sector Erase Suspend
Erase can be suspended during sector erase with Addr (“H” or “L”), Data (B0h)
Sector Erase Resume
Erase can be resumed after suspend with Addr (“H” or “L”), Data (30h)
*1: Either of the two reset commands will reset the device.
*2: The fourth bus cycle is only for read.
Notes : • Address bits A20 to A11 = X = “H” or “L” for all address commands except or Program Address (PA) and
Sector Address (SA).
• Bus operations are defined in “MBM29F016A User Bus Operations Table” in “■ FLEXIBLE SECTORERASE ARCHITECTURE”.
• RA = Address of the memory location to be read.
IA = Autoselect read address that sets A6, A1, A0.
PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of
the WE pulse.
SA = Address of the sector to be erased. The combination of A20, A19, A18, A17, and A16 will uniquely select
any sector.
• RD = Data read from location RA during read operation.
ID = Device code / manufacture code for the address located by IA.
PD = Data to be programmed at location PA. Data is latched on the rising edge of WE.
• Read and Byte program functions to non-erasing sectors are allowed in the Erase Suspend mode.
• The system should generate the following address pattens: 555h or 2AAh to addresses A10 to A0.
• The command combinations not described in “MBM29F016A Command Definitions” are illegal.
Type
MBM29F016A Sector Protection Verify Autoselect Codes Table
Code DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0
A6
A1
A0 (HEX)
A20 to A18
Manufacture’s
Code
X
X
X
VIL
VIL
VIL
04h
0
0
0
0
0
1
0
0
Device Code
X
X
X
VIL
VIL
VIH
ADh
1
0
1
0
1
1
0
1
Sector Group
Protection
Sector Group
Addresses
VIL
VIH
VIL
01h*
0
0
0
0
0
0
0
1
* : Outputs 01h at protected sector addresses and outputs 00h at unprotected sector addresses.
7
MBM29F016A-70/-90/-12
SA0
SA1
SA2
SA3
SA4
SA5
SA6
SA7
SA8
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
SA24
SA25
SA26
SA27
SA28
SA29
SA30
SA31
A19
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
A20
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A20
8
Sector Address Table
A18
A17
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
A16
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Sector Group Addresses Table
A19
A18
Address Range
000000h to 00FFFFh
010000h to 01FFFFh
020000h to 02FFFFh
030000h to 03FFFFh
040000h to 04FFFFh
050000h to 05FFFFh
060000h to 06FFFFh
070000h to 07FFFFh
080000h to 08FFFFh
090000h to 09FFFFh
0A0000h to 0AFFFFh
0B0000h to 0BFFFFh
0C0000h to 0CFFFFh
0D0000h to 0DFFFFh
0E0000h to 0EFFFFh
0F0000h to 0FFFFFh
100000h to 10FFFFh
110000h to 11FFFFh
120000h to 12FFFFh
130000h to 13FFFFh
140000h to 14FFFFh
150000h to 15FFFFh
160000h to 16FFFFh
170000h to 17FFFFh
180000h to 18FFFFh
190000h to 19FFFFh
1A0000h to 1AFFFFh
1B0000h to 1BFFFFh
1C0000h to 1CFFFFh
1D0000h to 1DFFFFh
1E0000h to 1EFFFFh
1F0000h to 1FFFFFh
Sectors
SGA0
0
0
0
SA0 to SA3
SGA1
0
0
1
SA4 to SA7
SGA2
0
1
0
SA8 to SA11
SGA3
0
1
1
SA12 to SA15
SGA4
1
0
0
SA16 to SA19
SGA5
1
0
1
SA20 to SA23
SGA6
1
1
0
SA24 to SA27
SGA7
1
1
1
SA28 to SA31
MBM29F016A-70/-90/-12
• Thirty two 64 K byte sectors
• 8 sector groups each of which consists of 4 adjacent sectors in the following pattern; sectors 0-3, 4-7, 8-11,
12-15, 16-19, 20-23, 24-27, and 28-31
• Individual-sector or multiple-sector erase capability
• Sector group protection is user-definable
SA31
64 K byte
SA30
64 K byte
SA29
64 K byte
SA28
64 K byte
1FFFFFh
1EFFFFh
1DFFFFh
Sector
Group 7
1CFFFFh
1BFFFFh
1AFFFFh
19FFFFh
18FFFFh
17FFFFh
16FFFFh
15FFFFh
14FFFFh
13FFFFh
12FFFFh
11FFFFh
10FFFFh
32 Sectors Total
0FFFFFh
0EFFFFh
0DFFFFh
0CFFFFh
0BFFFFh
0AFFFFh
09FFFFh
08FFFFh
07FFFFh
06FFFFh
05FFFFh
04FFFFh
SA3
64 K byte
SA2
64 K byte
SA1
64 K byte
SA0
64 K byte
03FFFFh
02FFFFh
01FFFFh
Sector
Group 0
00FFFFh
000000h
9
MBM29F016A-70/-90/-12
■ FUNCTIONAL DESCRIPTION
Read Mode
The MBM29F016A has two control functions which must be satisfied in order to obtain data at the outputs. CE
is the power control and should be used for a device selection. OE is the output control and should be used to
gate data to the output pins if a device is selected.
Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable
access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output
enable access time is the delay from the falling edge of OE to valid data at the output pins (assuming the
addresses have been stable for at least tACC-tOE time).
Standby Mode
There are two ways to implement the standby mode on the MBM29F016A device, one using both the CE and
RESET pins; the other via the RESET pin only.
When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC ±0.3 V.
Under this condition the current consumed is less than 5 µA. A TTL standby mode is achieved with CE and
RESET pins held at VIH. Under this condition the current is reduced to approximately 1 mA. During Embedded
Algorithm operation, VCC Active current (ICC2) is required even CE = VIH. The device can be read with standard
access time (tCE) from either of these standby modes.
When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS ±0.3 V
(CE = “H” or “L”). Under this condition the current consumed is less than 5 µA. A TTL standby mode is achieved
with RESET pin held at VIL (CE = “H” or “L”). Under this condition the current required is reduced to approximately
1 mA. Once the RESET pin is taken high, the device requires 500 ns of wake up time before outputs are valid
for read access.
In the standby mode the outputs are in the high impedance state, independent of the OE input.
Output Disable
With the OE input at a logic high level (VIH), output from the device is disabled. This will cause the output pins
to be in a high impedance state.
Autoselect
The autoselect mode allows the reading out of a binary code from the device and will identify its manufacturer
and type. This mode is intended for use by programming equipment for the purpose of automatically matching
the device to be programmed with its corresponding programming algorithm. This mode is functional over the
entire temperature range of the device.
To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two
identifier bytes may then be sequenced from the device outputs by toggling address A0 from VIL to VIH. All
addresses are don't cares except A0, A1, and A6. (See “MBM29F016A Sector Protection Verify Autoselect Codes
Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”.)
The manufacturer and device codes may also be read via the command register, for instances when the
MBM29F016A is erased or programmed in a system without access to high voltage on the A9 pin. The command
sequence is illustrated in “MBM29F016A Command Definitions Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”. (Refer to Autoselect Command section.)
Byte 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04h) and byte 1 (A0 = VIH) represents the device
identifier code for MBM29F016A = ADh. These two bytes are given in the “MBM29F016A Sector Protection
Verify Autoselect Codes Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”. All identifiers for
manufactures and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper
device codes when executing the Autoselect, A1 must be VIL. (See “MBM29F016A Sector Protection Verify
Autoselect Codes Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”.)
10
MBM29F016A-70/-90/-12
The Autoselect mode also facilitates the determination of sector group protection in the system. By performing
a read operation at the address location XX02h with the higher order address bits A18, A19 and A20 set to the
desired sector group address, the device will return 01h for a protected sector group and 00h for a non-protected
sector group.
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve
as inputs to the internal state machine. The state machine outputs dictate the function of the device.
The command register itself does not occupy any addressable memory location. The register is a latch used to
store the commands, along with the address and data information needed to execute the command. The
command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on
the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE,
whichever happens first. Standard microprocessor write timings are used.
Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters.
Sector Group Protection
The MBM29F016A features hardware sector group protection. This feature will disable both program and erase
operations in any combination of eight sector groups of memory. Each sector group consists of four adjacent
sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31 (see
“Sector Group Address Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”). The sector group
protection feature is enabled using programming equipment at the user's site. The device is shipped with all
sector groups unprotected.
To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest
VID = 11.5 V), CE = VIL. The sector addresses (A20, A19, and A18) should be set to the sector to be protected.
“Sector Address Table” and “Sector Group Address Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”
define the sector address for each of the thirty two (32) individual sectors, and the sector group address for each
of the eight (8) individual group sectors. Programming of the protection circuitry begins on the falling edge of
the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during
the WE pulse. See “Temporary Sector Group Unprotection Timing Diagram” in “■ TIMING DIAGRAM” and
“Temporary Sector Group Unprotection Algorithm” in “■ FLOW CHART” for sector protection waveforms and
algorithm.
To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9
with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A20, A19, and A18) while (A6, A1, A0) = (0,
1, 0) will produce a logical “1” code at device output DQ0 for a protected sector. Otherwise the device will produce
00h for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are DON’T CARES.
Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes.
It is also possible to determine if a sector group is protected in the system by writing an Autoselect command.
Performing a read operation at the address location XX02h, where the higher order addresses (A20, A19, and
A18) are the desired sector group address will produce a logical “1” at DQ0 for a protected sector group. See
“MBM29F016A Sector Protection Verify Autoselect Codes Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE” for Autoselect codes.
11
MBM29F016A-70/-90/-12
Temporary Sector Group Unprotection
This feature allows temporary unprotection of previously protected sector groups of the MBM29F016A device
in order to change data. The Sector Group Unprotection mode is activated by setting the RESET pin to high
voltage (12 V). During this mode, formerly protected sector groups can be programmed or erased by selecting
the sector group addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sector
groups will be protected again. Refer to “Temporary Sector Group Unprotection Timing Diagram” in “■ TIMING
DIAGRAM” and “Temporary Sector Group Unprotection Algorithm” in “■ FLOW CHART”.
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register.
Writing incorrect address and data values or writing them in the improper sequence will reset the device to the
read mode. “MBM29F016A Command Definitions Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”
defines the valid register command sequences. Note that the Erase Suspend (B0h) and Erase Resume (30h)
commands are valid only while the Sector Erase operation is in progress. Moreover, both Read/Reset commands
are functionally equivalent, resetting the device to the read mode.
Read/Reset Command
The read or reset operation is initiated by writing the read/reset command sequence into the command register.
Microprocessor read cycles retrieve array data from the memory. The device remains enabled for reads until the
command register contents are altered.
The device will automatically power-up in the read/reset state. In this case, a command sequence is not required
to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no
spurious alteration of the memory content occurs during the power transition. Refer to the AC Read
Characteristics and Waveforms for the specific timing parameters.
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such,
manufacture and device codes must be accessible while the device resides in the target system. PROM
programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high
voltage onto the address lines is not generally desirable system design practice.
The device contains an autoselect command operation to supplement traditional PROM programming
methodology. The operation is initiated by writing the autoselect command sequence into the command register.
Following the command write, a read cycle from address XX00h retrieves the manufacture code of 04h. A read
cycle from address XX01h returns the device code ADh. (See “MBM29F016A Sector Protection Verify Autoselect
Codes Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”).
All manufacturer and device codes will exhibit odd parity with the DQ7 defined as the parity bit.
Sector state (protection or unprotection) will be informed by address XX02h.
Scanning the sector group addresses (A18, A19, A20) while (A6, A1, A0) = (0, 1, 0) will produce a logical “1” at
device output DQ0 for a protected sector group.
To terminate the operation, it is necessary to write the read/reset command sequence into the register and also
to write the Autoselect command during the operation, execute it after writing Read/Reset command sequence.
Byte Programming
The device is programmed on a byte-by-byte basis. Programming is a four bus cycle operation. There are two
“unlock” write cycles. These are followed by the program set-up command and data write cycles. Addresses are
latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of
12
MBM29F016A-70/-90/-12
CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming.
Upon executing the Embedded Program Algorithm command sequence, the system is not required to provide
further controls or timings. The device will automatically provide adequate internally generated program pulses
and verify the programmed cell margin.
This automatic programming operation is completed when the data on DQ7 is equivalent to data written to this
bit at which time the device returns to the read mode and addresses are no longer latched. (See “Hardware
Sequence Flags Table” in “■ FUNCTIONAL DESCRIPTION”, Hardware Sequence Flags.) Therefore, the device
requires that a valid address to the device be supplied by the system at this particular instance of time. Data
Polling must be performed at the memory location which is being programmed.
Any commands written to the chip during this period will be ignored. If a hardware reset occurs during the
programming operation, it is impossible to guarantee the data are being written.
Programming is allowed in any sequence and across sector boundaries. Beware that a data “0” cannot be
programmed back to a “1”. Attempting to do so may either hang up the device or result in an apparent success
according to the data polling algorithm but a read from reset/read mode will show that the data is still “0”. Only
erase operations can convert “0”s to “1”s.
“Embedded ProgramTM Algorithm” in “■ FLOW CHART” illustrates the Embedded ProgrammingTM Algorithm
using typical command strings and bus operations.
Chip Erase
Chip erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the
“set-up” command. Two more “unlock” write cycles are then followed by the chip erase command.
Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase
Algorithm command sequence the device will automatically program and verify the entire memory for an all zero
data pattern prior to electrical erase. The system is not required to provide any controls or timings during these
operations.
The automatic erase begins on the rising edge of the last WE pulse in the command sequence and terminates
when the data on DQ7 is “1” (see Write Operation Status section) at which time the device returns to read the
mode.
“Embedded EraseTM Algorithm” in “■ FLOW CHART” illustrates the Embedded Erase™ Algorithm using typical
command strings and bus operations.
Sector Erase
Sector erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the
“set-up” command. Two more “unlock” write cycles are then followed by the Sector Erase command. The sector
address (any address location within the desired sector) is latched on the falling edge of WE, while the command
(Data = 30h) is latched on the rising edge of WE. After time-out of 50 µs from the rising edge of the last sector
erase command, the sector erase operation will begin.
Multiple sectors may be erased concurrently by writing the six bus cycle operations on “MBM29F016A Command
Definitions Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”. This sequence is followed with writes
of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between
writes must be less than 50 µs otherwise that command will not be accepted and erasure will start. It is
recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts
can be re-enabled after the last Sector Erase command is written. A time-out of 50 µs from the rising edge of
the last WE will initiate the execution of the Sector Erase command(s). If another falling edge of the WE occurs
within the 50 µs time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window
is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend
13
MBM29F016A-70/-90/-12
during this time-out period will reset the device to the read mode, ignoring the previous command string. Resetting
the device once execution has begun will corrupt the data in that sector. In that case, restart the erase on those
sectors and allow them to complete. (Refer to the Write Operation Status section for DQ3, Sector Erase Timer
operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 31).
Sector erase does not require the user to program the device prior to erase. The device automatically programs
all memory locations in the sector(s) to be erased prior to electrical erase. When erasing a sector or sectors the
remaining unselected sectors are not affected. The system is not required to provide any controls or timings
during these operations.
The automatic sector erase begins after the 50 µs time out from the rising edge of the WE pulse for the last
sector erase command pulse and terminates when the data on DQ7 is “1” (see Write Operation Status section)
at which time the device returns to the read mode. Data polling must be performed at an address within any of
the sectors being erased.
“Embedded EraseTM Algorithm” in “■ FLOW CHART” illustrates the Embedded Erase™ Algorithm using typical
command strings and bus operations.
Erase Suspend
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads
from or programs to a sector not being erased. This command is applicable ONLY during a Sector Erase operation
which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written
during the Chip Erase operation or Embedded Program Algorithm. Writing the Erase Suspend command during
the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase
operation.
Any other command written during the Erase Suspend mode will be ignored except the Erase Resume command.
Writing the Erase Resume command resumes the erase operation. The addresses are DON’T CARES when
writing the Erase Suspend or Erase Resume command.
When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum
of 15 µs to suspend the erase operation. When the device has entered the erase-suspended mode, the RY/BY
output pin and the DQ7 bit will be at logic “1”, and DQ6 will stop toggling. The user must use the address of the
erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes
of the Erase Suspend command are ignored.
When the erase operation has been suspended, the device defaults to the erase-suspend-read mode. Reading
data in this mode is the same as reading from the standard read mode except that the data must be read from
sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the
device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2.)
After entering the erase-suspend-read mode, the user can program the device by writing the appropriate
command sequence for Byte Program. This program mode is known as the erase-suspend-program mode.
Again, programming in this mode is the same as programming in the regular Byte Program mode except that
the data must be programmed to sectors that are not erase-suspended. Successively reading from the erasesuspended sector while the device is in the erase-suspend-program mode will cause DQ2 to toggle. The end of
the erase-suspended program operation is detected by the RY/BY output pin, Data polling of DQ7, or by the
Toggle Bit I (DQ6) which is the same as the regular Byte Program operation. Note that DQ7 must be read from
the Byte Program address while DQ6 can be read from any address.
To resume the operation of Sector Erase, the Resume command (30h) should be written. Any further writes of
the Resume command at this point will be ignored. Another Erase Suspend command can be written after the
chip has resumed erasing.
14
MBM29F016A-70/-90/-12
Write Operation Status
Status
Hardware Sequence Flags Table
DQ6
DQ7
Embedded Program Algorithm
0
0
1
0
Toggle
0
1
Toggle
1
1
0
0
Toggle*1
Erase Suspend Read
(Non-Erase Suspended Sector)
Data
Data
Data
Data
Data
Erase Suspend Program
(Non-Erase Suspended Sector)
DQ7
Toggle*2
0
0
1*3
DQ7
Toggle
1
0
1
0
Toggle
1
1
N/A
DQ7
Toggle
1
0
N/A
Embedded Program Algorithm
Exceeded
Time Limits
Embedded Erase Algorithm
Erase
Suspended
Mode
DQ2
Toggle
Erase Suspend Read
(Erase Suspended Sector)
Erase
Suspended
Mode
DQ3
DQ7
Embedded Erase Algorithm
In Progress
DQ5
Erase Suspend Program
(Non-Erase Suspended Sector)
*1 : Performing successive read operations from the erase-suspended sector will cause DQ2 to toggle.
*2 : Performing successive read operations from any address will cause DQ6 to toggle.
*3 : Reading the byte address being programmed while in the erase-suspend program mode will indicate logic “1”
at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle.
DQ7
Data Polling
The MBM29F016A device features Data Polling as a method to indicate to the host that the embedded algorithms
are in progress or completed. During the Embedded Program Algorithm, an attempt to read the device will
produce the complement of the data last written to DQ7. Upon completion of the Embedded Program Algorithm,
an attempt to read the device will produce the true data last written to DQ7. During the Embedded Erase™
Algorithm, an attempt to read the device will produce a “0” at the DQ7 output. Upon completion of the Embedded
Erase Algorithm an attempt to read the device will produce a “1” at the DQ7 output. The flowchart for Data Polling
(DQ7) is shown in “Data Polling Algorithm” in “■ FLOW CHART”.
Data polling will also flag the entry into Erase Suspend. DQ7 will switch “0” to “1” at the start of the Erase Suspend
mode. Please note that the address of an erasing sector must be applied in order to observe DQ7 in the Erase
Suspend Mode.
During Program in Erase Suspend, Data polling will perform the same as in regular program execution outside
of the suspend mode.
For chip erase, the Data Polling is valid after the rising edge of the sixth WE pulse in the six write pulse sequence.
For sector erase, the Data Polling is valid after the last rising edge of the sector erase WE pulse. Data Polling
must be performed at sector address within any of the sectors being erased and not a sector that is within a
protected sector group. Otherwise, the status may not be valid.
Just prior to the completion of Embedded Algorithm operation DQ7 may change asynchronously while the output
enable (OE) is asserted low. This means that the device is driving status information on DQ7 at one instant of
time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7
output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operations
and DQ7 has a valid data, the data outputs on DQ6 to DQ0 may be still invalid. The valid data on DQ7 to DQ0 will
be read on the successive read attempts.
15
MBM29F016A-70/-90/-12
The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase
Algorithm, Erase Suspend, erase-suspend-program mode, or sector erase time-out. (See “Hardware Sequence
Flags Table” in “■ FUNCTIONAL DESCRIPTION”.)
See “AC Waveforms for Data Polling during Embedded Algorithm Operations” in “■ TIMING DIAGRAM” for the
Data Polling timing specifications and diagrams.
DQ6
Toggle Bit I
The MBM29F016A also features the “Toggle Bit I” as a method to indicate to the host system that the embedded
algorithms are in progress or completed.
During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from
the device at any address will result in DQ6 toggling between one and zero. Once the Embedded Program or
Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive
attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth WE pulse in the four
write pulse sequence. For chip erase, and sector erase the Toggle Bit I is valid after the rising edge of the sixth
WE pulse in the six write pulse sequence. For Sector Erase, the Toggle Bit I is valid after the last rising edge of
the sector erase WE pulse. The Toggle Bit I is active during the sector erase time out.
In programming, if the sector being written to is protected, the Toggle Bit I will toggle for about 2 µs and then
stop toggling without the data having changed. In erase, the device will erase all the selected sectors except for
the ones that are protected. If all selected sectors are protected, the chip will toggle the Toggle Bit I for about
100 µs and then drop back into read mode, having changed none of the data.
Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will
cause DQ6 to toggle.
See “AC Waveforms for Toggle Bit I during Embedded Algorithm Operations” in “■ TIMING DIAGRAM” for the
Toggle Bit I timing specifications and diagrams.
DQ5
Exceeded Timing Limits
DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under
these conditions DQ5 will produce a “1”. This is a failure condition which indicates that the program or erase
cycle was not successfully completed. Data Polling DQ7, DQ6 is the only operating function of the device under
this condition. The CE circuit will partially power down the device under these conditions (to approximately 2
mA). The OE and WE pins will control the output disable functions as described in “MBM29F016A User Bus
Operations Table” in “■ FLEXIBLE SECTOR-ERASE ARCHITECTURE”.
The DQ5 failure condition may also appear if a user tries to program a 1 to a location that is previously programmed
to 0. In this case the device locks out and never completes the Embedded Algorithm operation. Hence, the
system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the device has exceeded timing
limits, the DQ5 bit will indicate a “1”. Please note that this is not a device failure condition since the device was
incorrectly used. If this occurs, reset the device.
DQ3
Sector Erase Timer
After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will
remain low until the time-out is complete. Data Polling and Toggle Bit I are valid after the initial sector erase
command sequence.
16
MBM29F016A-70/-90/-12
If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may
be used to determine if the sector erase timer window is still open. If DQ3 is high (“1”) the internally controlled
erase cycle has begun; attempts to write subsequent commands (other than Erase Suspend) to the device will
be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low (“0”),
the device will accept additional sector erase commands. To insure the command has been accepted, the system
software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3
were high on the second status check, the command may not have been accepted.
Refer to “Hardware Sequence Flags Table” in “■ FUNCTIONAL DESCRIPTION”: Hardware Sequence Flags.
DQ2
Toggle Bit II
This toggle bit II, along with DQ6, can be used to determine whether the device is in the Embedded Erase™
Algorithm or in Erase Suspend.
Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded Erase™ Algorithm. If
the device is in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause
DQ2 to toggle. When the device is in the erase-suspended-program mode, successive reads from the byte
address of the non-erase suspended sector will indicate a logic “1” at the DQ2 bit.
DQ7
DQ6
DQ2
DQ7
Toggle
1
Erase
0
Toggle
Toggle
Erase Suspend Read *1
(Erase-Suspended Sector)
1
1
Toggle
DQ7 *2
Toggle
1 *2
Mode
Program
Erase Suspend Program
*1 : These status flags apply when outputs are read from a sector that has been erase-suspended.
*2 : These status flags apply when outputs are read from the byte address of the non-erase suspended sector.
DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend
Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized
as follows:
For example, DQ2 and DQ6 can be used together to determine the erase-suspend-read mode (DQ2 toggles while
DQ6 does not). See also “Hardware Sequence Flags Table” in “■ FUNCTIONAL DESCRIPTION” and “DQ2 vs.
DQ6” in “■ TIMING DIAGRAM”.
Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase
mode, DQ2 toggles if this bit is read from the erasing sector.
RY/BY
Ready/Busy
The MBM29F016A provides a RY/BY open-drain output pin as a way to indicate to the host system that the
Embedded Algorithms are either in progress or has been completed. If the output is low, the device is busy with
either a program or erase operation. If the output is high, the device is ready to accept any read/write or erase
operation. When the RY/BY pin is low, the device will not accept any additional program or erase commands
with the exception of the Erase Suspend command. If the MBM29F016A is placed in an Erase Suspend mode,
the RY/BY output will be high, by means of connecting with a pull-up resistor to VCC.
17
MBM29F016A-70/-90/-12
During programming, the RY/BY pin is driven low after the rising edge of the fourth WE pulse. During an erase
operation, the RY/BY pin is driven low after the rising edge of the sixth WE pulse. The RY/BY pin will indicate a
busy condition during RESET pulse. Refer to “RY/BY Timing Diagram during Program/Erase Operations” in “■
TIMING DIAGRAM” for a detailed timing diagram. The RY/BY pin is pulled high in standby mode.
Since this is an open-drain output, several RY/BY pins can be tied together in parallel with a pull-up resistor to VCC.
RESET
Hardware Reset
The MBM29F016A device may be reset by driving the RESET pin to VIL. The RESET pin must be kept low (VIL)
for at least 500 ns. Any operation in progress will be terminated and the internal state machine will be reset to
the read mode 20 µs after the RESET pin is driven low. If a hardware reset occurs during a program operation,
the data at that particular location will be indeterminate.
When the RESET pin is low and the internal reset is complete, the device goes to standby mode and cannot be
accessed. Also, note that all the data output pins are tri-stated for the duration of the RESET pulse. Once the
RESET pin is taken high, the device requires tRH of wake up time until outputs are valid for read access.
The RESET pin may be tied to the system reset input. Therefore, if a system reset occurs during the Embedded
Program or Erase Algorithm, the device will be automatically reset to read mode and this will enable the system’s
microprocessor to read the boot-up firmware from the Flash memory.
Data Protection
The MBM29F016A is designed to offer protection against accidental erasure or programming caused by spurious
system level signals that may exist during power transitions. During power up the device automatically resets
the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory
contents only occurs after successful completions of specific multi-bus cycle command sequences.
The device also incorporates several features to prevent inadvertent write cycles resulting from VCC power-up
and power-down transitions or system noise.
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less
than 3.2 V (typically 3.7 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits
are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until
the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct
to prevent unintentional writes when VCC is above 3.2 V.
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH or WE = VIH. To initiate a write cycle CE and WE
must be a logical zero while OE is a logical one.
Power-Up Write Inhibit
Power-up of the device with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE.
The internal state machine is automatically reset to the read mode on power-up.
18
MBM29F016A-70/-90/-12
■ ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Symbol
Unit
Min
Max
Tstg
−55
+125
°C
TA
−40
+85
°C
VIN, VOUT
−2.0
+7.0
V
Power Supply Voltage *1
VCC
−2.0
+7.0
V
A9, OE, and RESET *1,*3
VIN
−2.0
+13.5
V
Storage Temperature
Ambient Temperature with Power Applied
Voltage with Respect to Ground All pins except A9,
OE, and RESET *1,*2
*1 : Voltage is defined on the basis of VSS = GND = 0 V.
*2 : Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, input or I/O pins may undershoot
VSS to –2.0 V for periods of up to 20 ns. Maximum DC voltage on output and I/O pins is VCC +0.5 V. During
voltage transitions, outputs may overshoot to VCC +2.0 V for periods up to 20 ns.
*3 : Minimum DC input voltage on A9, OE, and RESET pins are –0.5 V. During voltage transitions, A9, OE, and
RESET pins may undershoot VSS to –2.0 V for periods of up to 20 ns. Voltage difference between input and
power supply voltage (VIN – VCC) does not exceed +9.0 V. Maximum DC input voltage on A9, OE, and RESET are
+13.0 V which may overshoot to +14.0 V for periods up to 20 ns.
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Ambient Temperature
Power Supply Voltages*
Symbol
MBM29F016A-70
MBM29F016A-90/-12
MBM29F016A-70
MBM29F016A-90/-12
TA
VCC
Value
Unit
Min
Max
−20
+70
−40
+85
+4.75
+5.25
V
+4.50
+5.50
V
°C
* : Voltage is defined on the basis of VSS = GND = 0 V.
Note : Operating ranges define those limits between which the functionality of the device is guaranteed.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
19
MBM29F016A-70/-90/-12
■ MAXIMUM OVERSHOOT / MAXIMUM UNDERSHOOT
1.
Maximum Undershoot Waveform
+0.8 V
20 ns
20 ns
–0.5 V
–2.0 V
20 ns
2.
Maximum Overshoot Waveform 1
20 ns
VCC +2.0 V
VCC +0.5 V
+2.0 V
20 ns
20 ns
3. Maximum Overshoot Waveform 2
20 ns
+14.0 V
+13.0 V
VCC +0.5 V
20 ns
Note : This waveform is applied for A9, OE and RESET.
20
20 ns
MBM29F016A-70/-90/-12
■ DC CHARACTERISTICS
Parameter
Symbol
Test Conditions
Min
Max
Unit
Input Leakage Current
ILI
VIN = VSS to VCC, VCC = VCC Max
—
±1.0
µA
Output Leakage Current
ILO
VOUT = VSS to VCC,
VCC = VCC Max
—
±1.0
µA
A9, OE, RESET Inputs Leakage
Current
ILIT
VCC = VCC Max,
A9, OE, RESET = 12.5 V
—
50
µA
VCC Active Current *1
ICC1
CE = VIL, OE = VIH
—
40
mA
VCC Active Current *2
ICC2
CE = VIL, OE = VIH
—
45
mA
VCC = VCC Max, CE = VIH,
RESET = VIH
—
1
mA
VCC = VCC Max, CE = VCC ±0.3 V,
RESET = VCC ±0.3 V
—
5
µA
VCC = VCC Max,
RESET = VIL
—
1
mA
VCC = VCC Max,
RESET = VSS ±0.3 V
—
5
µA
VCC Current (Standby)
VCC Current (Standby, Reset)
ICC3
ICC4
Input Low Level
VIL
—
–0.5
0.8
V
Input High Level
VIH
—
2.0
VCC+0.5
V
Voltage for Autoselect and Sector
Protection (A9, OE, RESET) *3, *4
VID
—
11.5
12.5
V
Output Low Voltage Level
VOL
IOL = 12.0 mA, VCC = VCC Min
—
0.45
V
VOH1
IOH = –2.5 mA, VCC = VCC Min
2.4
—
V
VOH2
IOH = –100 µA
VCC–0.4
—
V
3.2
4.2
V
Output High Voltage Level
Low VCC Lock-Out Voltage
VLKO
—
*1 : The ICC current listed includes both the DC operating current and the frequency dependent component
(at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH.
*2 : ICC active while Embedded Algorithm (program or erase) is in progress.
*3 : Applicable to sector protection function.
*4 : (VID – VCC) do not exceed 9 V.
21
MBM29F016A-70/-90/-12
■ AC CHARACTERISTICS
• Read Only Operations Characteristics
Symbol
Parameter
-70 *1
Test
Setup
JEDEC Standard
Min
-90 *2
Max Min Max Min Max
Unit
Read Cycle Time
tAVAV
tRC
—
70
—
90
—
120
—
ns
Address to Output Delay
tAVQV
tACC
CE = VIL
OE = VIL
—
70
—
90
—
120
ns
Chip Enable to Output Delay
tELQV
tCE
OE = VIL
—
70
—
90
—
120
ns
Output Enable to Output Delay
tGLQV
tOE
—
—
40
—
40
—
50
ns
Chip Enable to Output High-Z
tEHQZ
tDF
—
—
20
—
20
—
30
ns
Output Enable to Output High-Z
tGHQZ
tDF
—
—
20
—
20
—
30
ns
Output Hold Time From Addresses,
CE or OE, whichever occurs first
tAXQX
tOH
—
0
—
0
—
0
—
ns
—
tREADY
—
—
20
—
20
—
20
µs
RESET Pin Low to Read Mode
*1 : Test Conditions:
Output Load: 1 TTL gate and 30 pF
Input rise and fall times: 5 ns
Input pulse levels: 0.0 V or 3.0 V
Timing measurement reference level
Input: 1.5 V
Output: 1.5 V
*2 : Test Conditions:
Output Load: 1 TTL gate and 100 pF
Input rise and fall times: 5 ns
Input pulse levels: 0.45 V or 2.4 V
Timing measurement reference level
Input: 0.8 V and 2.0 V
Output: 0.8 V and 2.0 V
5.0 V
Diode = 1N3064
or Equivalent
2.7 kΩ
Device
Under
Test
6.2 kΩ
CL
Diode = 1N3064
or Equivalent
Notes : • CL = 30 pF including jig capacitance
• CL = 100 pF including jig capacitance
Test Conditions
22
-12 *2
MBM29F016A-70/-90/-12
• Write/Erase/Program Operations
Symbol
Parameter
MBM29F016A
-70
JEDEC Standard
-90
-12
Unit
Min Typ Max Min Typ Max Min Typ Max
Write Cycle Time
tAVAV
tWC
70
—
—
90
—
— 120 —
—
ns
Address Setup Time
tAVWL
tAS
0
—
—
0
—
—
0
—
—
ns
Address Hold Time
tWLAX
tAH
45
—
—
45
—
—
50
—
—
ns
Data Setup Time
tDVWH
tDS
30
—
—
45
—
—
50
—
—
ns
Data Hold Time
tWHDX
tDH
0
—
—
0
—
—
0
—
—
ns
Output Enable Setup Time
—
tOES
0
—
—
0
—
—
0
—
—
ns
Output
Read
Enable Hold
Toggle Bit I and Data Polling
Time
0
—
—
0
—
—
0
—
—
ns
—
tOEH
10
—
—
10
—
—
10
—
—
ns
Read Recover Time Before Write
tGHWL
tGHWL
0
—
—
0
—
—
0
—
—
ns
Read Recover Time Before Write
tGHEL
tGHEL
0
—
—
0
—
—
0
—
—
ns
CE Setup Time
tELWL
tCS
0
—
—
0
—
—
0
—
—
ns
WE Setup Time
tWLEL
tWS
0
—
—
0
—
—
0
—
—
ns
CE Hold Time
tWHEH
tCH
0
—
—
0
—
—
0
—
—
ns
WE Hold Time
tEHWH
tWH
0
—
—
0
—
—
0
—
—
ns
Write Pulse Width
tWLWH
tWP
35
—
—
45
—
—
50
—
—
ns
Write Pulse Width
tELEH
tCP
35
—
—
45
—
—
50
—
—
ns
Write Pulse Width High
tWHWL
tWPH
20
—
—
20
—
—
20
—
—
ns
Write Pulse Width High
tEHEL
tCPH
20
—
—
20
—
—
20
—
—
ns
Byte Programming Operation
tWHWH1
tWHWH1
—
8
—
—
8
—
—
8
—
µs
Sector Erase Operation *1
tWHWH2
tWHWH2
—
1
—
—
1
—
—
1
—
s
—
—
8
—
—
8
—
—
8
s
—
tVCS
50
—
—
50
—
—
50
—
—
µs
—
tVLHT
4
—
—
4
—
—
4
—
—
µs
— 100 —
— 100 —
—
µs
VCC Setup Time
Voltage Transition Time *2
2
Write Pulse Width *
—
tWPP
2
100 —
OE Setup Time to WE Active *
—
tOESP
4
—
—
4
—
—
4
—
—
µs
CE Setup Time to WE Active *2
—
tCSP
4
—
—
4
—
—
4
—
—
µs
Recover Time from RY/BY
—
tRB
0
—
—
0
—
—
0
—
—
ns
RESET Pulse Width
—
tRP
500 —
— 500 —
— 500 —
—
ns
RESET Hold Time Before Read
—
tRH
50
—
—
50
—
—
50
—
—
ns
Program/Erase Valid to RY/BY Delay
—
tBUSY
—
—
70
—
—
90
—
— 120
ns
Delay Time from Embedded Output Time
—
tEOE
—
—
40
—
—
40
—
—
ns
50
*1 : This does not include the preprogramming time.
*2 : This timing is for Sector Protection operation.
23
MBM29F016A-70/-90/-12
■ ERASE AND PROGRAMMING PERFORMANCE
Limits
Parameter
Unit
Comments
Min
Typ
Max
Sector Erase Time
—
1
8
s
Excludes 00h programming
prior to erasure
Byte Programming Time
—
8
150
µs
Excludes system-level
overhead
Chip Programming Time
—
16.8
40
s
Excludes system-level
overhead
100,000
—
—
cycle
Erase/Program Cycle
■ TSOP(1) PIN CAPACITANCE
Parameter
Symbol
Parameter Description
Typ
Max
Unit
CIN
Input Capacitance
VIN = 0
8
10
pF
COUT
Output Capacitance
VOUT = 0
8
10
pF
CIN2
Control Pin Capacitance
VIN = 0
9
10
pF
Note : Test conditions TA = +25°C, f = 1.0 MHz
24
Test Setup
MBM29F016A-70/-90/-12
■ TIMING DIAGRAM
• Key to Switching Waveforms
WAVEFORM
INPUTS
OUTPUTS
Must Be
Steady
Will Be
Steady
May
Change
from H to L
Will Be
Changing
from H to L
May
Change
from L to H
Will Be
Changing
from L to H
“H” or “L”
Any Change
Permitted
Changing,
State
Unknown
Does Not
Apply
Center Line is
HighImpedance
“Off” State
(1) AC Waveforms for Read Operations
tRC
Address Stable
Address
tACC
CE
tDF
tOE
OE
tOEH
WE
tCE
Outputs
High-Z
tOH
Output Valid
High-Z
25
MBM29F016A-70/-90/-12
(2) AC Waveforms for Alternate WE Controlled Program Operations
3rd Bus Cycle
Address
Data Polling
555h
PA
PA
tAH
tWC
tRC
tAS
tCH
CE
tGHWL
OE
tWP
tWHWH1
WE
tWPH
tCS
tDF
tDH
A0h
Data
tOE
PD
DQ7
DOUT
DOUT
tDS
tOH
5.0 V
tCE
Notes : • PA is address of the memory location to be programmed.
• PD is data to be programmed at byte address.
• DQ7 is the output of the complement of the data written to the device.
• DOUT is the output of the data written to the device.
• Figure indicates last two bus cycles of four bus cycle sequence.
26
MBM29F016A-70/-90/-12
(3) AC Waveforms for Alternate CE Controlled Program Operations
3rd Bus Cycle
Address
Data Polling
555h
PA
PA
tAH
tWC
tAS
tWH
WE
tGHEL
OE
tCP
tWHWH1
CE
tWS
tCPH
tDH
Data
A0h
PD
DQ7
DOUT
tDS
5.0 V
Notes : • PA is address of the memory location to be programmed.
• PD is data to be programmed at byte address.
• DQ7 is the output of the complement of the data written to the device.
• DOUT is the output of the data written to the device.
• Figure indicates last two bus cycles of four bus cycle sequence.
27
MBM29F016A-70/-90/-12
(4) AC Waveforms Chip/Sector Erase Operations
tAH
Address
555h
2AAh
555h
555h
2AAh
SA*
tAS
CE
tGHWL
OE
tWP
WE
tCS
tWPH
10h for Chip Erase
tDH
Data
VCC
tDS
AAh
55h
80h
AAh
55h
tVCS
* : SA is the sector address for Sector Erase. Address = 555h for Chip Erase.
28
10h/30h
MBM29F016A-70/-90/-12
(5) AC Waveforms for Data Polling during Embedded Algorithm Operations
tCH
CE
tDF
tOE
OE
tOEH
WE
tCE
*
DQ7
Data
DQ7 =
Valid Data
DQ7
tEOE
tWHWH1 or 2
DQ6 to DQ0
Data
High-Z
DQ6 to DQ0 = Output Flug
DQ7 to DQ0
Valid Data
High-Z
* : DQ7 = Valid Data (The device has completed the Embedded operation.)
(6) AC Waveforms for Toggle Bit I during Embedded Algorithm Operations
CE
tOEH
WE
tOES
OE
*
DQ6
Data
DQ6 = Toggle
DQ6 =
Stop Toggling
DQ6 = Toggle
DQ7 to DQ0
Valid
tOE
* : DQ6 stops toggling (The device has completed the Embedded operation.)
29
MBM29F016A-70/-90/-12
(7) RY/BY Timing Diagram during Program/Erase Operations
CE
Rising edge of the last WE signal
WE
Entire programming
or erase operations
RY/BY
tBUSY
(8) RESET, RY/BY Timing Diagram
WE
RESET
tRP
tREADY
RY/BY
30
tRB
MBM29F016A-70/-90/-12
(9) AC Waveforms for Sector Group Protection Timing Diagram
A 20, A 19, A 18
SGAX
SGAY
A0
A1
A6
12V
5V
A9
tVLHT
12V
5V
OE
tVLHT
tVLHT
tVLHT
tWPP
WE
tOESP
tCSP
CE
Data
01h
tVCS
tOE
VCC
SGAX = Sector Group Address for initial sector
SGAY = Sector Group Address for next sector
31
MBM29F016A-70/-90/-12
(10) Temporary Sector Group Unprotection Timing Diagram
VCC
tVIDR
tVCS
tVLHT
VID
5V
5V
RESET
CE
WE
tVLHT
Program or Erase Command Sequence
tVLHT
RY/BY
Unprotection period
(11) DQ2 vs. DQ6
Enter
Embedded
Erasing
WE
Erase
Suspend
Erase
Enter Erase
Suspend Program
Erase Suspend
Read
Erase
Suspend
Program
DQ6
DQ2*
Toggle
DQ2 and DQ6
with OE or CE
* : DQ2 is read from the erase-suspended sector.
32
Erase
Resume
Erase Suspend
Read
Erase
Erase
Complete
MBM29F016A-70/-90/-12
■ FLOW CHART
(1) Embedded ProgramTM Algorithm
EMBEDDED ALGORITHMS
Start
Write Program Command
Sequence
(See Below)
Data Polling Device
Increment Address
No
Last Address
?
Yes
Programming Completed
Program Command Sequence (Address/Command):
555h/AAh
2AAh/55h
555h/A0h
Program Address/Program Data
33
MBM29F016A-70/-90/-12
(2) Embedded Erase™ Algorithm
Start
Write Erase Command
Sequece
(See Below)
Data Polling or Toggle Bit I
Successfully Completed
Erasure Completed
Chip Erase Command Sequence
(Address/Command):
Individual Sector/Multiple Sector
Erase Command Sequence
(Address/Command):
555h/AAh
555h/AAh
2AAh/55h
2AAh/55h
555h/80h
555h/80h
555h/AAh
555h/AAh
2AAh/55h
2AAh/55h
555h/10h
Sector Address/30h
Sector Address/30h
Additional sector
erase commands
are optional.
Sector Address/30h
Note : To insure the command has been accepted, the system software should check the status
of DQ3 prior to and following each subsequent sector erase command. If DQ3 were high on
the second status check, the command may not have been accepted.
34
MBM29F016A-70/-90/-12
(3) Data Polling Algorithm
Start
VA = Address for programming
= Any of the sector addresses
within the sector being erased
during sector erase or multiple
erases operation.
= Any of the sector group
addresses within the sector not
being protected during sector
erase or multiple sector erases
operation.
Read Byte
(DQ7 to DQ0)
Addr. = VA
DQ7 = Data?
Yes
No
No
DQ5 = 1?
Yes
Read Byte
(DQ7 to DQ0)
Addr. = VA
DQ7 = Data?
Yes
No
Fail
Pass
Note : DQ7 is rechecked even if DQ5 = “1” because DQ7 may change simultaneously with DQ5.
35
MBM29F016A-70/-90/-12
(4) Toggle Bit I Algorithm
Start
Read
(DQ7 to DQ0)
Addr. = “H” or “L”
*1
Read
(DQ7 to DQ0)
Addr. = “H” or “L”
*1
No
DQ6 = Toggle
?
Yes
No
DQ5 = 1
?
Yes
Read
(DQ7 to DQ0)
Addr. = “H” or “L”
*1,*2
Read
(DQ7 to DQ0)
Addr. = “H” or “L”
*1,*2
DQ6 = Toggle
?
No
Yes
Fail
Pass
*1: Read toggle bit twice to determine whether it is toggling.
*2: DQ6 is rechecked even if DQ5 = “1” because DQ6 may stop toggling at the same time as DQ5
changing to “1”.
36
MBM29F016A-70/-90/-12
(5) Sector Group Protection Algorithm
Start
Setup Sector Group Addr.
(A20, A19, A18)
PLSCNT = 1
OE = VID, A9 = VID,
CE = VIL, RESET = VIH
Increment PLSCNT
Activate WE Pulse
Time out 100 µs
WE = VIH, CE = OE = VIL,
(A9 should remain VID)
Read from Sector Group
Addr. (A20, A19, A18)
A1 = 1, A0 = A6 = 0
No
No
PLSCNT = 25?
Yes
Remove VID from A9
Write Reset Command
Data = 01h?
Yes
Yes
Protect Another Sector
Group?
No
Device Failed
Remove VID from A9
Write Reset Command
Sector Protection
Completed
37
MBM29F016A-70/-90/-12
(6) Temporary Sector Group Unprotection Algorithm
Start
RESET = VID *1
Perform Erase or
Program Operations
RESET = VIH
Temporary Sector Group
Unprotection Completed *2
*1 : All Protected sector groups unprotected.
*2 : All previously protected sector groups are protected once again.
38
MBM29F016A-70/-90/-12
■ ORDERING INFORMATION
Part No.
Package
Access Time (ns)
MBM29F016A-70PFTN
MBM29F016A-90PFTN
MBM29F016A-12PFTN
48-pin plastic TSOP (1)
(FPT-48P-M19)
(Normal Bend)
70
90
120
MBM29F016A-70PFTR
MBM29F016A-90PFTR
MBM29F016A-12PFTR
48-pin plastic TSOP (1)
(FPT-48P-M20)
(Reverse Bend)
70
90
120
MBM29F016
A
-70
Remarks
PFTN
PACKAGE TYPE
PFTN = 48-Pin Thin Small Outline Package
(TSOP (1) ) Normal Bend
PFTR = 48-Pin Thin Small Outline Package
(TSOP (1) ) Reverse Bend
SPEED OPTION
See Product Selector Guide
A = Device Revision
DEVICE NUMBER/DESCRIPTION
MBM29F016
16 Mega-bit (2 M × 8-Bit) CMOS Flash Memory
5.0 V-only Read, Write, and Erase
64 K Byte (32 Sectors)
39
MBM29F016A-70/-90/-12
■ PACKAGE DIMENSIONS
Note 1) * : Values do not include resin protrusion.
Resin protrusion and gate protrusion are +0.15 (.006) Max (each side) .
Note 2) Pins width and pins thickness include plating thickness.
Note 3) Pins width do not include tie bar cutting remainder.
48-pin plastic TSOP(1)
(FPT-48P-M19)
LEAD No.
1
48
INDEX
Details of "A" part
0.25(.010)
0~8˚
0.60±0.15
(.024±.006)
24
25
* 12.00±0.20
20.00±0.20
(.787±.008)
* 18.40±0.20
(.724±.008)
"A"
0.10(.004)
(.472±.008)
+0.10
1.10 –0.05
+.004
.043 –.002
(Mounting
height)
+0.03
0.17 –0.08
+.001
.007 –.003
C
0.10±0.05
(.004±.002)
(Stand off height)
0.50(.020)
0.22±0.05
(.009±.002)
0.10(.004)
M
2003 FUJITSU LIMITED F48029S-c-6-7
Dimensions in mm (inches) .
Note : The values in parentheses are reference values.
(Continued)
40
MBM29F016A-70/-90/-12
(Continued)
Note 1) * : Values do not include resin protrusion.
Resin protrusion and gate protrusion are +0.15 (.006) Max (each side) .
Note 2) Pins width and pins thickness include plating thickness.
Note 3) Pins width do not include tie bar cutting remainder.
48-pin plastic TSOP(1)
(FPT-48P-M20)
LEAD No.
1
48
Details of "A" part
INDEX
0.60±0.15
(.024±.006)
0~8˚
0.25(.010)
24
25
+0.03
0.17 –0.08
+.001
0.10(.004)
.007 –.003
0.50(.020)
0.22±0.05
(.009±.002)
M
0.10±0.05
(.004±.002)
(Stand off height)
+0.10
"A"
1.10 –0.05
+.004
* 18.40±0.20
(.724±.008)
20.00±0.20
(.787±.008)
C
0.10(.004)
.043 –.002
(Mounting height)
* 12.00±0.20(.472±.008)
2003 FUJITSU LIMITED F48030S-c-6-7
Dimensions in mm (inches) .
Note : The values in parentheses are reference values.
41
MBM29F016A-70/-90/-12
FUJITSU LIMITED
All Rights Reserved.
The contents of this document are subject to change without notice.
Customers are advised to consult with FUJITSU sales
representatives before ordering.
The information, such as descriptions of function and application
circuit examples, in this document are presented solely for the
purpose of reference to show examples of operations and uses of
Fujitsu semiconductor device; Fujitsu does not warrant proper
operation of the device with respect to use based on such
information. When you develop equipment incorporating the
device based on such information, you must assume any
responsibility arising out of such use of the information. Fujitsu
assumes no liability for any damages whatsoever arising out of
the use of the information.
Any information in this document, including descriptions of
function and schematic diagrams, shall not be construed as license
of the use or exercise of any intellectual property right, such as
patent right or copyright, or any other right of Fujitsu or any third
party or does Fujitsu warrant non-infringement of any third-party’s
intellectual property right or other right by using such information.
Fujitsu assumes no liability for any infringement of the intellectual
property rights or other rights of third parties which would result
from the use of information contained herein.
The products described in this document are designed, developed
and manufactured as contemplated for general use, including
without limitation, ordinary industrial use, general office use,
personal use, and household use, but are not designed, developed
and manufactured as contemplated (1) for use accompanying fatal
risks or dangers that, unless extremely high safety is secured, could
have a serious effect to the public, and could lead directly to death,
personal injury, severe physical damage or other loss (i.e., nuclear
reaction control in nuclear facility, aircraft flight control, air traffic
control, mass transport control, medical life support system, missile
launch control in weapon system), or (2) for use requiring
extremely high reliability (i.e., submersible repeater and artificial
satellite).
Please note that Fujitsu will not be liable against you and/or any
third party for any claims or damages arising in connection with
above-mentioned uses of the products.
Any semiconductor devices have an inherent chance of failure. You
must protect against injury, damage or loss from such failures by
incorporating safety design measures into your facility and
equipment such as redundancy, fire protection, and prevention of
over-current levels and other abnormal operating conditions.
If any products described in this document represent goods or
technologies subject to certain restrictions on export under the
Foreign Exchange and Foreign Trade Law of Japan, the prior
authorization by Japanese government will be required for export
of those products from Japan.
F0306
 FUJITSU LIMITED Printed in Japan