SKYWORKS SKY14151

preliminary data sheet
SKY14151-350LF: High-Power Single Pole Four Throw
(SP4T) Switch with Decoder
Functional Diagram
Features
l
l
l
l
l
l
l
l
B
roadband operation (0.1–2.5 GHz)
L ow insertion loss (0.35 dB @ 1GHz, 0.5 dB @ 2 GHz) with
high isolation (29 dB @ 1 GHz)
V dd = 2.5 to 3 V for high-power applications, can be used
down to 1.8 V for low-power applications
H
igh linearity IMD < -110 dBm
G
ood harmonic performance: < -80 dBc @ 0.9 GHz
L ow voltage logic compatible( Vhigh Min. = 1.8 V)
3 x 3 mm 16-pin QFN, lead (Pb)-free and
RoHS-compliant package
S witch uses state-of-the-art GaAs pHEMT process
VDD
RF1
RF2
ANT
RF3
RF4
V1
V2
Description
The SKY14151 is a symmetrical single pole four throw (SP4T)
switch designed for broad band, high power switching applications
which demand high linearity and low insertion loss. The switch is
manufactured using the Skyworks state of the art pHEMT process.
This is a general purpose switch that is optimized for a variety of
multimode applications such as GSM/WCDMA/EDGE.
The SKY14151 features integrated logic that uses only two control
lines for the switch operation. The low current consumption of
SKY14151 makes it suitable for battery-operated applications.
This part comes in an industry-standard 3 x 3 mm 16-pin QFN
package that is lead (Pb)-free and RoHS-compliant.
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Preliminary Data Sheet: Based on engineering results. Sampling quantities available.
Pin out and package have been determined.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200983 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • February 12, 2009
1
preliminary Data Sheet • SKY14151-350LF
Electrical Specifications
TA = 25 °C, VDD = 2.5–3 V, Vhigh = VDD, all unused RF ports are terminated in a 50 W load, unless otherwise noted
Parameter
Conditions
Min.
Typ.
Max.
Unit
Electrical Characteristics
Insertion loss
Isolation
Return loss (worst case)
f = 1 GHz
0.35
dB
f = 2 GHz
0.5
dB
f = 2.5 GHz
0.55
dB
f = 1 GHz
29
dB
f = 2 GHz
25
dB
f = 2.5 GHz
23
dB
0.1 – 2.5 GHz
dB
Operating Characteristics
Second harmonic
Third harmonic
Input 0.1 dB compression point
ffundamental = 900 MHz, PIN = 34.5 dBm
-80
dBc
ffundamental = 1.8 GHz, PIN = 31.5 dBm
-80
dBc
ffundamental = 900 MHz, PIN = 34.5 dBm
-80
dBc
ffundamental = 1.8 GHz, PIN = 31.5 dBm
-80
dBc
f = 900 MHz
37
dBm
34
dBm
Imd3
f = 1.8 GHz
Standard setup
-110
dBm
Power handling under mismatch
f = 900 MHz, VSWR = 20:1
34.5
dBm
f = 1.8 GHz, VSWR = 20:1
31.5
dBm
Switching speed
5
µs
Startup time
25
µs
DC/Control Specifications
Supply voltage (VBATT)
2.5
Switched supply voltage (VDD)
2.5
Switched supply current (IDD)
Control voltage
4.4
2.65
3
0.3
Vhigh
1.8(1)
V
mA
2.65
3
V
Vlow
0.2
0.3
V
Control current, IHigh
0.5
µA
Control current, ILow
0.5
µA
1. For 1.8 V control, VDD must be < 2.65 V.
2
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
February 12, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200983 Rev. C
preliminary Data Sheet • SKY14151-350LF
Package Outline (3 x 3 x 0.75 mm 16 pin QFN)
3
1.50
0.02 + 0.03
0.02 - 0.02
Pin 1
Indicator
1.50
Characteristic
Switched supply voltage (VDD)
Input power
(low frequency to 2.5 GHz, VDD = 2.5–3 V)
Control voltage
3
0.75 ± 0.05
1.70 + 0.10
1.70 - 0.15
0.225 x 45°
Pin 1 Indicator
0.85
Exposed Pad
(0.20)
Seating
Plane
Absolute Maximum Ratings
0.85
1.70 + 0.10
1.70 - 0.15
Detail B
Value
3V
36 dBm
3V
Operating temperature
-30 °C to +85 °C
Storage temperature
-50 °C to +100 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: A lthough this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all
times from ESD. Static charges may easily produce
potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Detail C
0.40 ± 0.10
5
0.25
0.25 + 0.05
0.25 - 0.07
Detail B
Detail C
1. Dimensioning and tolerancing per ASME Y14.5M – 1994.
2. Coplanarity applies to the exposed heat sink slug as well as the terminals.
3. Plating requirement per source control drawing (SCD) 2504.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200983 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • February 12, 2009
3
preliminary Data Sheet • SKY14151-350LF
Pin Out (Top View)
GND
1
VDD
2
CTRL2
3
CTRL1
4
Logic
NC
RF2
GND
RF1
16
15
14
13
The switch can operate in one of four states, which are listed in
the truth table.
12 GND
Exposed
Paddle
GND
11 ANT
10 GND
9 GND
5
6
7
8
GND
RF4
GND
RF3
The switch may be used in the active or standby mode. The
modes are controlled by the voltage which is applied to pin 2,
VDD. The switch is active when the VDD is high and in standby
mode when VDD is low, in which case all paths are in the
isolation state.
Truth Table
State
Pin Descriptions
Pin #
Pin Name
1, 5, 7, 9,
10, 12, 14
GND
Ground. This pin should be connected to ground via
the lowest possible electrical impedance.
2
VDD
Supply voltage input. This voltage may be switched.
The switching time must be no longer than the startup time.
3
CTRL2
Control signal 2. The logic level applied to this pin,
along with the logic level applied to pin 4, controls
the state of the switch.
4
CTRL1
Control signal 1. The logic level applied to this pin,
along with the logic level applied to pin 3, controls
the state of the switch.
6
RF4
RF output 4. This pin is either connected directly to
or is disconnected from pin 11, depending upon the
control voltages applied to pins 3 and 4.
8
RF3
RF output 4. This pin is either connected directly to
or is disconnected from pin 11, depending upon the
control voltages applied to pins 3 and 4.
11
ANT
Antenna. This pin is connected directly and
exclusively to pin 6, 8, 13 or 15, depending upon
the control voltages applied to pins 3 and 4.
13
RF1
RF output 4. This pin is either connected directly to
or is disconnected from pin 11, depending upon the
control voltages applied to pins 3 and 4.
15
RF2
RF output 4. This pin is either connected directly to
or is disconnected from pin 11, depending upon the
control voltages applied to pins 3 and 4.
NC
This pad can be left open.
16
Paddle
4
Description
Ctrl1
Ctrl2
RF Path
1
VLOW
VLOW
Ant – RF1
2
VLOW
VHIGH
Ant – RF2
3
VHIGH
VLOW
Ant – RF3
4
VHIGH
VHIGH
Ant – RF4
VDD = High
Exposed paddle. This paddle should be connected to
ground via the lowest possible electrical and thermal
impedance.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
February 12, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200983 Rev. C
preliminary Data Sheet • SKY14151-350LF
Evaluation Board Schematic
RF2
RF1
C
C1
C = 100.0 pF
C
C2
C=100.0 pF
NC
16
VDD
C
C4
C = 10 nF
15
14
C
CESD
C = 1 pF
13
1
12
2
11
3
ANT
C
C9
C = 100 pF
9
5
6
7
L = 10 nH
R=
10
4
L
LESD
8
CTL2
QFN
X1
C
C5
C = 100.0 pF
CTL1
C
C6
C=100.0 pF
C
C7
C = 100.0 pF
RF4
Applications
C
C8
C = 100.0 pF
RF3
Evaluation Board
An LESD and a CESD comprise the ESD filter. This topology and
these component values may vary according to the ESD requirement and acceptable insertion loss for a specific application.
Components LESD and CESD constiture an ESD filter. Decoupling
capacitors (C3 through C6) are recommended for suppressing
noise and preventing RF leakage into the DC control circuits.”
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200983 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • February 12, 2009
5
preliminary Data Sheet • SKY14151-350LF
Typical Performance Data
0
0
-0.5
-10
-20
-1.0
Isolation (dB)
Insertion Loss (dB)
TA = 25 °C, VDD = 2.5–3 V, Vhigh = Vs, all unused RF ports are terminated in a 50 W load, unless otherwise noted
-1.5
-2.0
-2.5
-30
-40
-50
-60
-3.0
-70
0
0.5
1.0
1.5
2.0
2.5
0
0.5
1.0
1.5
Frequency (GHz)
Frequency (GHz)
insertion loss
isolation
2.0
0
Return Loss (dB)
-5
-10
-15
-20
-25
-30
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
return loss
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
February 12, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200983 Rev. C
2.5
preliminary Data Sheet • SKY14151-350LF
Copyright © 2008, 2009, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200983 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • February 12, 2009
7