200197B.pdf

DATA SHEET
AS216-339, AS216-339LF: GaAs SPDT IC 7 W T/R Switch
300 kHz–2.5 GHz
Features
Pin Out
High isolation (30 dB @ 0.9 GHz)
Designed for mobile radio applications
● P
-1 dB = 10 W @ 0.9 GHz, 25 °C
● High intercept point (IP3 63 dBm,@ 0.9 GHz)
● Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
●
8
2
7
J1
1
●
GND
CBL
GND
6
GND
5
3
J2
CBL
V1
CBL
4
V2
J3
Description
The AS216-339 is a high-power IC FET SPDT switch in a plastic
SOIC-8 exposed paddle package. This switch has been designed
for use where extremely high linearity is required. It can be controlled with positive, negative or a combination of both voltages.
Some standard implementations include antenna changeover,
T/R and diversity switching over 2 W. This switch can be used in
many analog and digital wireless communication systems
including cellular, GSM and PCS applications.
NEW
External DC blocking capacitors (CBL) are required only if VHIGH > 0.0 V.
CBL = 100 pF for operation >500 MHz.
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 °C (0, -5 V)
Parameter(1)
Insertion
loss(2)
Frequency
Min.
300 kHz–0.5 GHz
300 kHz–1.0 GHz
300 kHz–2.5 GHz
Isolation
300 kHz–0.5 GHz
300 kHz–1.0 GHz
300 kHz–2.5 GHz
VSWR(3)
300 kHz–1.0 GHz
300 kHz–2.5 GHz
32
27
19
Typ.
Max.
Unit
0.7
0.8
1.0
0.8
0.9
1.1
dB
dB
dB
34
28
20
1.2:1
1.5:1
dB
dB
dB
1.4:1
1.7:1
dB
dB
1. All measurements made in a 50 Ω system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Insertion loss state.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200197 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 16, 2006
1
DATA SHEET • AS216-339
Operating Characteristics at 25 °C (0, -5 V)
Parameter
Condition
Switching characteristics
Rise, fall
On, off
Video feedthru
Frequency
Min.
Typ.
10/90% or 90/10% RF
50% CTL to 90/10% RF
TRISE = 1 ns, BW = 500 MHz
Max.
Unit
6
12
30
ns
ns
mV
dBm
dBm
Input power for 1 dB compression
VCTL = 5 V
VCTL = 10 V
0.9 GHz
0.9 GHz
35
40
Intermodulation intercept point
For two-tone input power 13 dBm
IP3
0.9 GHz
63
dBm
45
°C/W
Thermal resistance
VLOW= -12 V ≤ VLOW ≤ 0 V, 500 µA max.
VHIGH= 0 V ≤ VHIGH ≤ 12 V, 500 µA max.
Differential = 5 V ≤ (VHIGH – VLOW) < 12 V
Control voltages
Typical Performance Data (0, -5 V)
0
-0.1
-5
-10
J3
-15
-0.5
Isolation (dB)
Insertion Loss (dB)
-0.3
J3
-0.7
J2
-0.9
-20
J2
-25
-30
-35
-1.1
-40
-1.3
-45
-1.5
-50
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Typical Isolation vs. Frequency
0
4.0
12
-5
10
Max. Input Power (W)
Return Loss (dB)
-10
-15
-20
J2
-25
-30
-35
J3
-40
PIN (W)
8
6
4
2
-45
-50
0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
0
20
40
60
80
100
120
140
Heat Sink Temperature (˚C)
Typical Return Loss vs. Frequency
Temperature Derating Curve (0, +10)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
160
Frequency (GHz)
July 16, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200197 Rev. B
DATA SHEET • AS216-339
Absolute Maximum Ratings
0
-0.2
Characteristic
Insertion Loss (dB)
-0.4
10 V
-0.6
5V
-0.8
-1.0
Value
RF input power
8 W > 0.9 GHz,
0, -12 V
Control voltage
(VHIGH – VLOW) < 12 V
Operating temperature
-1.2
-40 °C to +85 °C
Storage temperature
-1.4
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
-1.6
-1.8
-2.0
20
22
24
26
28
30
32
34
36
38
40
Input Power (dBm)
Compression at 900 MHz 25 °C
Truth Table
V1
V2
J1–J2
J1–J3
VLOW
VHIGH
Insertion loss
Isolation
VHIGH
VLOW
Isolation
Insertion loss
All other conditions not recommended.
VLOW = 0 to -12 V.
VHIGH = 0 to 12 V.
Differential = 5 V ≤ ( VHIGH– VLOW) < 12 V.
Refer to Application Notes for further information on differential voltage operation.
Recommended Solder Reflow Profiles
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
SOIC-8 Exposed Paddle
0.155 (3.94 mm)
+ 0.002 (0.05 mm)
- 0.005 (0.13 mm)
Pin 1
Indicator
0.194 (4.93 mm)
+ 0.002 (0.05 mm)
- 0.005 (0.13 mm)
0.016 (0.41 mm)
+ 0.0032 (0.080 mm)
- 0.080 (0.060 mm)
Refer to the “Recommended Solder Reflow Profile”
Application Note.
0.078
(1.98 mm)
0.061 (1.55 mm)
± 0.005 (0.13 mm)
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Exposed
Pad
0.097
(2.46 mm)
0.050
(1.27 mm)
BSC
0.090
(2.29 mm)
0.003 (0.08 mm)
± 0.002 (0.05 mm)
0.090
(2.29 mm)
0.236 (5.99 mm)
+ 0.008 (0.21 mm)
- 0.006 (0.15 mm)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200197 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 16, 2006
3
DATA SHEET • AS216-339
Copyright © 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
July 16, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200197 Rev. B