SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 D D D D D D D EPIC (Enhanced-Performance Implanted CMOS) Submicron Process ESD Protection Exceeds 2000 V Per MIL-STD-883, Method 3015; Exceeds 200 V Using Machine Model (C = 200 pF, R = 0) Latch-Up Performance Exceeds 250 mA Per JESD 17 Typical VOLP (Output Ground Bounce) < 0.8 V at VCC = 3.3 V, TA = 25°C Typical VOHV (Output VOH Undershoot) > 2 V at VCC = 3.3 V, TA = 25°C Inputs Accept Voltages to 5.5 V Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), and Thin Shrink Small-Outline (PW) Packages D, DB, OR PW PACKAGE (TOP VIEW) 1OE 1A 1Y 2OE 2A 2Y GND 1 14 2 13 3 12 4 11 5 10 6 9 7 8 VCC 4OE 4A 4Y 3OE 3A 3Y description This quadruple bus buffer gate is designed for 1.65-V to 3.6-V VCC operation. The SN74LVC125A features independent line drivers with 3-state outputs. Each output is disabled when the associated output-enable (OE) input is high. To ensure the high-impedance state during power up or power down, OE should be tied to VCC through a pullup resistor; the minimum value of the resistor is determined by the current-sinking capability of the driver. Inputs can be driven from either 3.3-V or 5-V devices. This feature allows the use of these devices as translators in a mixed 3.3-V/5-V system environment. The SN74LVC125A is characterized for operation from –40°C to 85°C. FUNCTION TABLE (each buffer) INPUTS OE A OUTPUT Y L H H L L L H X Z Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC is a trademark of Texas Instruments Incorporated. Copyright 1998, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 logic symbol† 1 1OE 1A EN 2 1 3 4 2OE 2A 3OE 3A 4OE 4A 6 5 1Y 2Y 10 8 9 13 11 12 3Y 4Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. logic diagram (positive logic) 1OE 1A 2OE 2A 1 2 3OE 3 1Y 4 5 3A 4OE 6 2Y 4A 10 9 8 3Y 13 12 11 4Y absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6.5 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6.5 V Output voltage range, VO (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA Continuous output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Package thermal impedance, θJA (see Note 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127°C/W DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stressratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The value of VCC is provided in the recommended operating conditions table. 3. The package thermal impedance is calculated in accordance with JESD 51. 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 recommended operating conditions (see Note 4) VCC Supply voltage VIH High-level input voltage Operating Data retention only VCC = 1.65 V to 1.95 V VCC = 2.3 V to 2.7 V MIN MAX 1.65 3.6 VI VO IOH Low-level input voltage 0.65 × VCC 2 0.35 × VCC 0.8 Output voltage Low level output current Low-level ∆t/∆v Input transition rise or fall rate V 0.7 Input voltage IOL V 1.7 VCC = 2.3 V to 2.7 V VCC = 2.7 V to 3.6 V 0 5.5 V 0 VCC –4 V VCC = 1.65 V VCC = 2.3 V High level output current High-level V 1.5 VCC = 2.7 V to 3.6 V VCC = 1.65 V to 1.95 V VIL UNIT –8 VCC = 2.7 V VCC = 3 V mA –12 –24 VCC = 1.65 V VCC = 2.3 V 4 VCC = 2.7 V VCC = 3 V 12 8 mA 24 0 8 ns/V TA Operating free-air temperature –40 85 °C NOTE 4: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = –100 µA IOH = –4 mA VOH VCC 1.65 V to 3.6 V 1.65 V VCC–0.2 1.2 2.3 V 1.7 2.7 V 2.2 3V 2.4 3V 2.2 IOH = –8 mA IOH = –12 12 mA IOH = –24 mA IOL = 100 µA MIN TYP† MAX UNIT V 1.65 V to 3.6 V 0.2 IOL = 4 mA IOL = 8 mA 1.65 V 0.45 2.3 V 0.7 IOL = 12 mA IOL = 24 mA 2.7 V 0.4 3V 0.55 II ICC VI = 5.5 V or GND VI = VCC or GND, 3.6 V ±5 µA 3.6 V 10 µA ∆ICC One input at VCC – 0.6 V, Other inputs at VCC or GND 2.7 V to 3.6 V 500 µA VOL IO = 0 Ci VI = VCC or GND † All typical values are at VCC = 3.3 V, TA = 25°C. POST OFFICE BOX 655303 3.3 V • DALLAS, TEXAS 75265 5 V pF 3 SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 switching characteristics over recommended operating free-air temperature range (unless otherwise noted) (see Figures 1 through 3) FROM (INPUT) TO (OUTPUT) tpd A ten tdis PARAMETER VCC = 1.8 V ± 0.15 V VCC = 2.5 V ± 0.2 V MIN MAX MIN MAX Y 1 12.3 1 OE Y 1 14.3 OE Y 1 11.1 VCC = 2.7 V MIN VCC = 3.3 V ± 0.3 V UNIT MAX MIN MAX 6.3 5.5 1 4.8 ns 1 7.4 6.6 1 5.4 ns 1 5.6 5 1 4.6 ns 1 ns tsk(o)† † Skew between any two outputs of the same package switching in the same direction operating characteristics, TA = 25°C PARAMETER Cpd 4 TEST CONDITIONS Power dissipation capacitance per gate f = 10 MHz POST OFFICE BOX 655303 VCC = 1.8 V ± 0.15 V VCC = 2.5 V ± 0.2 V VCC = 3.3 V ± 0.3 V TYP TYP TYP 7.4 11.3 15 • DALLAS, TEXAS 75265 UNIT pF SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 PARAMETER MEASUREMENT INFORMATION VCC = 1.8 V ± 0.15 V 2 × VCC S1 1k Ω From Output Under Test Open GND CL = 30 pF (see Note A) 1k Ω TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 2 × VCC Open LOAD CIRCUIT tw VCC Timing Input VCC/2 VCC/2 VCC/2 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VCC/2 VCC/2 0V tPLH Output Control (low-level enabling) tPLZ VCC VCC/2 VCC/2 VOL Output Waveform 2 S1 at Open (see Note B) VOL + 0.15 V VOL tPHZ tPZH VOH VCC/2 0V Output Waveform 1 S1 at 2 × VCC (see Note B) tPHL VCC/2 VCC VCC/2 tPZL VCC Input VOLTAGE WAVEFORMS PULSE DURATION th VCC Data Input VCC/2 0V 0V tsu Output VCC VCC/2 Input VCC/2 VOH VOH – 0.15 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2 ns, tf ≤ 2 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 PARAMETER MEASUREMENT INFORMATION VCC = 2.5 V ± 0.2 V 2 × VCC S1 500 Ω From Output Under Test Open GND CL = 30 pF (see Note A) 500 Ω TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 2 × VCC GND LOAD CIRCUIT tw VCC Timing Input VCC/2 VCC/2 VCC/2 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VCC/2 VCC/2 0V tPLH Output Control (low-level enabling) tPLZ VCC VCC/2 VCC/2 VOL Output Waveform 2 S1 at GND (see Note B) VOL + 0.15 V VOL tPHZ tPZH VOH VCC/2 0V Output Waveform 1 S1 at 2 × VCC (see Note B) tPHL VCC/2 VCC VCC/2 tPZL VCC Input VOLTAGE WAVEFORMS PULSE DURATION th VCC Data Input VCC/2 0V 0V tsu Output VCC VCC/2 Input VCC/2 VOH VOH – 0.15 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2 ns, tf ≤ 2 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 2. Load Circuit and Voltage Waveforms 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN74LVC125A QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS SCAS290F – JANUARY 1993 – REVISED JUNE 1998 PARAMETER MEASUREMENT INFORMATION VCC = 2.7 V AND 3.3 V ± 0.3 V 6V S1 500 Ω From Output Under Test Open GND CL = 50 pF (see Note A) 500 Ω TEST S1 tpd tPLZ/tPZL tPHZ/tPZH Open 6V GND tw LOAD CIRCUIT 2.7 V 2.7 V Timing Input 0V 0V VOLTAGE WAVEFORMS PULSE DURATION th 2.7 V Data Input 1.5 V 1.5 V 0V VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 1.5 V 1.5 V 0V tPLH tPHL VOH 1.5 V 2.7 V Output Control (low-level enabling) 1.5 V 1.5 V VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES tPLZ 3V Output Waveform 1 S1 at 6 V (see Note B) Output Waveform 2 S1 at GND (see Note B) 1.5 V 0V tPZL 2.7 V Output Input 1.5 V 1.5 V tsu Input 1.5 V 1.5 V tPZH VOL + 0.3 V VOL tPHZ 1.5 V VOH – 0.3 V VOH 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. D. The outputs are measured one at a time with one transition per measurement. E. tPLZ and tPHZ are the same as tdis. F. tPZL and tPZH are the same as ten. G. tPLH and tPHL are the same as tpd. Figure 3. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated