MACOM PSOSDO6A

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
P Series
UL Recognized
CSA Certified
VDE Approved
PE filtered
PS non-filtered
PS filtered
P Series
The P series CHAMELEON power entry module offers
the most popular features in a small footprint design
As the first 10A module to provide all five power
entry functions in one compact design, the
chameleon module readily adapts to its environment
and the needs of international markets.
• Snap-in or flange mounting
• Standard IEC 60321-1 C14 power inlet
• Both North American and metric fusing
capabilities
• Two voltage selection options (for 4-voltage
selection, see the M, L or LA Series)
• Optional DPST on/off switch
• Filter options for general purpose, medical and
high-performance EMI filtering
The CHAMELEON module’s compact design and
modular construction allows selection of the required
power entry feature — without altering the panel
cutout. And the CHAMELEON module, with its
optional adapters, will fit several common panel
cutouts.
Filter Types
The CHAMELEON module has four filter and one
non-filtered option:
S models provide an extended performance two
element circuit EMI filter, with attenuation similar to
the EEB Series power inlet filter. It offers protection
for general purpose applications with stray Line to
Ground and Line to Line noise that must be attenuated at the power inlet. These filters have limited
leakage current and are available in current ratings of
3, 6 and 10A.
L models feature a high performance medical filter
designed to help bring most digital equipment
(including switching power supplies) into compliance
with EN55022, Level B (as well as FCC part 15J, Class
B) conducted emissions limits. They are available
with current ratings of 6 and 10A. These high
performance versions are only available with
mounting ears, single voltage selection, in a complete
RFI shield with options for switch, fuses and current
ratings. Mounting extenders are not compatible with
the L or Z models.
Z models provide a high performance three element
differential mode circuit filter, with extended EMI
attenuation similar to the M Series Z models, to help
bring most digital equipment (including switching
power supplies) into compliance with EN55022, Level
B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of
6 and 10A. These high performance versions are only
available with mounting ears, single voltage selection,
in a complete RFI shield with options for switch, fuses
and current ratings. Mounting extenders are not
compatible with the L or Z models. For minimum
depth behind the panel, see the M Series
B models are non-filtered and incorporate an interconnection block. The block connects the voltage
selection terminals of an unfiltered CHAMELEON
module with an IEC connector and an optional switch
to reduce external wiring. Compatible with the A or B
RFI shield options.
H models provide susceptibility protection with
minimal leakage current, and are suitable for patient
care and non-patient care medical equipment.
192
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Ordering Information
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature.
Note: For any option where shown as “0” use the digit ZERO (0) not the letter (O).
Mounting
Style
Extender
Options1
Switch
Options*
Voltage
Select2
Fuse
Options
Filter
Type
Filter
Current
Shield
Options1
P S J 0 X S S 6 0
Mounting Style
E = Mounting ears
(Horizontal axis)
S = Snap-in
M = Mounting ears
Switch Option
0 = Blank
S = Double pole
single throw
(DPST)
Fuse Options
D = Dual fuse
S = Single fuse
Filter Current
0 = No filter
3 = 3A
6 = 6A
X = 10A
3
(Vertical axis)
Input Voltage Select
0 = Single voltage
S = Dual voltage2
select (SMPS)
X = Dual voltage2
select (series/parallel)
Extender for
J-Series or others
Shield Options
Filter Type
0 = No shield
0 = No filter
A = Filter shield
B = Interconnection
B = Complete
block3
Shield
H = Medical Filter
L = High Performance C = Complete can
(for L & Z models)
Medical4
S = General purpose
Z = High Performance4
Power Inlet Filters & Power Entry Modules
Extender
Option
0 = None
C = FN260
J = J Series
L = L Series1
Notes:
1
L Series extender cannot be added to units
with a shield. No style of extender can be
added to units with B or C shields.
2
Dual voltage options are not available with
L or Z Filter Types
Fuse holder
3 When using the interconnection block, the last
3 digits of the part number are BX (0, A, or B)
4 High performance versions (L or Z filter types)
are available with any switch or fuse option but
only in 6 or 10A with horizontal (PE) or
vertical (PM) mounting ears, single voltage (0),
complete shield (C) and no extenders
Optional switch
*
For alternative switch orientation options,
please contact technical support or your
Corcom product sales representative
Optional filter
The part number PS0SXSS6B would represent:
P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S)
general purpose filter (S) for 6A (6) with a B shield (B)
193
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Voltage Selection
Shield Options
P series power entry modules include the voltage
selector integral with the fuse holder. Three voltage
selection options are each supported by one of three
different fuse holders. The fifth digit of the part
number specifies which of the three fuse holders is
included to provide the desired voltage selection.
The single voltage fuse holder (option “0”) has no
voltage indication markings. The dual voltage options
select 115V or 230V by removing the fuse holder, flipping it over, and reinstalling it. Voltage selection is
indicated through a window in the P Series door. The
“SMPS” fuse holder (option “S”) jumpers two independent P Series terminals to indicate 230V
operation to a switching mode power supply. The
“PRSR” parallel/serial fuse holder (option “X”)
connects the windings of the equipment’s dual
primary transformer (not included) to step down the
voltage or double up the current. The markings on
the voltage selection fuse holders also remind the
user to install the appropriate fuse for the current at
the selected voltage.
The P series offers several RF shield options. The
metal shield, optional on S, H and B filtered models,
provides shielding from radiated emissions and
provides an RF ground for the filter to the panel. This
shield is available in two versions; a shield of the filter
components (designated by an A as the final digit)
and a complete shield (designated by B as the final
digit).
The A shield covers the filter portion of the module
and increases performance of the filter by protecting
the components from RFI coupling. This shield
allows the use of the C or J extender.
The B shield covers the entire power entry module
with metal, protecting the filter from RFI coupling,
and covering the mounting cut-out to block RFI
entering or leaving the equipment. The B shield
cannot be used with any extender.
A complete metal enclosure is integral to both the
high performance L and Z models, and must be specified by a C in the part number’s final digit. This
option is only available with the L or Z models.
Input Voltage Selection Schemes
S - “SPMS” Jumper Type
115V
230V
Power on/off
Hot
A
G
Note 1
Note 1
Note 1
Note 1
B
Ground
Neutral
C
Power
input
Sel.
Jumpers
D
H
SMPS
Provision for
single fusing
X - “PRSR” Parallel / Serial Type for
Dual Primary Transformer
115V
230V
Power on/off
Hot
“A” Shield
G
Note 1
Note 2
A
B
115V
“B” Shield
Ground
Note 1
Neutral
C
Note 2
H
Provision for
single fusing
115V
D
Transformer
primary

 

194
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Fuseholder
Accessories
Another feature of the P series power entry module is
the versatile fusing arrangement. The fuse holder can
hold two 1/4” x 1-1/4” (3AG) or 5 x 20mm (metric)
fuses. Single fusing is supported with a conversion
clip that shorts one of the two fuse positions, and is
designated by an S in the sixth part number digit. A
module designated for a single fuse may be reconfigured by the manufacturer or the user to accept two
fuses by simply removing the shorting clip. For applications intended for dual fusing, specify a D in the
sixth part number digit.
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
PA100: Power interconnect assembly
For voltage select models. Designed for use with
either filtered or non-filtered units, 6” wire leads
Conversion Clip for
Single Fuse
Applications
3
Power Inlet Filters & Power Entry Modules
PA101: Plug only
PA102: Pins only for use with PA101
PA105: Same as PA100 but with two wires for
units with no voltage selection
Interconnection Block
Installation of the unfiltered versions of the P series
requires wiring of the IEC socket terminals to the
optional switch and the switch to the fuse holder.
Labor can be eliminated by ordering the module
with an interconnection block. This feature, designated by “BX” in the seventh and eighth digits, pre
wires the module so that only connection to the
equipment must be done during installation. The
interconnection block includes a plastic case to
prevent access to the internal connections.
PA400: J Extender
Extends P Series height to fit J panel cutout
PA410: L Extender
Extends P Series width to fit L panel cutout
PA420: C Extender
Extends P Series height to fit C panel cutout
PA400
Extender
for
J Series Extender
J-Series or others
The dimensions of this alternative are the same as the
filtered versions.
Fuse holder
C & L Extenders can not be used with B Shields.
L Extender can not be used with shields
Optional switch
195
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Optional filter
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Specifications
Maximum leakage current each Line to Ground:
H & L Models
S & Z Models
@ 120 VAC 60 Hz:
2 A
.25 mA
@ 250 VAC 50 Hz:
5 A
.50 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Electrical Schematics
H Model
LINE
LOAD
2250 VDC
1450 VDC
Rated Voltage(max.):
250VAC
Operating Voltages:
Selectable or Fixed
115/230 VAC
S Model
LINE
Operating Frequency:
LOAD
50/60 Hz
Rated Current:
Non-Filtered – 10A
Filtered – 3, 6 or 10A
L Model
Fuseholder:
LINE
Accepts one or two fuses
.25 x 1.25”(not included)
or 5 x 20mm (not included)
DPST
10,000 operations at 51A max. inrush
Switch:
LOAD
Z Model
LINE
LOAD
Case Styles
Front View
PM
PE
PS
High Performance
Version Only
2.88 2.39
73.15 60.71
2.496
63.4



1.22
30.98
2.29
58.16
1.58
40.13
1.95
49.53
1.22
30.98


196
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Case Styles
(continued)
Extender Options
C Extender - FN260
J Extender - J Series
2.51
63.75
2.72
69.08
Bottom edge
Bottom edge
Standard Models - Side and Rear View
Non-Filtered
Filtered
3
2.29
58.16



Power Inlet Filters & Power Entry Modules
.225
5.715
2.13
54.10
1.93
49.02


High Performance Models - Side and Rear View
PM
PE
2.39
60.71
2.17
55.12
3.93
99.82
1.12
28.45
1.23
31.24
4.42
112.27





197
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Case Styles (continued)
Shield Options
“A” Shield
“B” Shield
2.19
55.63
Note:
2.19
55.63
Shields can only be used with filtered models. B shield may not be used with J or C extender
Recommended Panel Cutout
Cutout
PM
PE
“A”
2.496
63.40
“B”
R
.06
1.524
1.575
40.00
.135
Note:
Mounting Hole Diameter 3.43
For snap-in applications, the “A” sides must have a .020 [.508] radius on the installation side.
Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer’s application
parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels.
Style
Dimension “A”
Dimension “B”
+.008 - .000
+.008 - .000
No Shield
Shielded
High Performance
Standard
High Performance
1.06 [26.92]
1.12 [28.45]
1.12 [28.45]
2.13 [54.10]
2.201 [55.91]
PE
1.12 [28.45]
1.12 [28.45]
1.15 [29.21]
2.201 [55.91]*
2.201 [55.91]
PS
1.06 [26.92]
1.12 [28.45]
-
2.201 [55.91]*
-
PSC
1.06 [26.92]
1.12 [28.45]
-
2.52 [64.01]
-
PSJ
1.06 [26.92]
1.12 [28.45]
-
2.60 [66.04]
-
PSL
1.12 [28.45]
-
-
2.201 [55.91]*
-
PM
*For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90]
198
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Performance Data
Typical Insertion Loss
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
S Models
3A
6A
10A
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0.1
1
10
30
Frequency in MHz
0
10
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz
3
H Models
6A
10A
db
100
db
100
db
100
90
90
90
80
80
80
70
70
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
0
0.1
1
10
30
Frequency in MHz
0
Power Inlet Filters & Power Entry Modules
3A
10
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz
L Models
6A
10A
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
Z Models
6A
10A
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
199
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Versatile Power Entry Module with Small Footprint
(continued)
P Series
Minimum Insertion Loss
Measured in closed 50 Ohm system
Differential Mode / Symmetrical (Line to Line)
Common Mode / Asymmetrical (Line to Ground)
 

  
 









 
  
  







 
 

 



















































 
 

























































  
 




 

  
 




 

 

 
 





















 




















 
 








































200
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com