MA-COM 5EHM1S

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
M Series
UL Recognized
CSA Certified
VDE Approved
XM / ZM
VM
Ordering Information
5EFM4SC
Mounting Type
C– Snap-In
Omit for flange mount
Voltage Selection Positions
1 or 4
M Series
Filter Type
F – General purpose
H – Medical
X – High performance
Z – Premium performance
V – Non-filtered
Leakage current designation
E – Low leakage (<0.5 mA)
(Filtered models only)
Current Rating @120 VAC
3, 5 or 6A
• Family of slim power entry modules that consume
minimal depth behind panel
• Four compact modules each provide a different
option combination
3
• Available non-filtered or with one of four filter
circuits designed to meet a wide variety of
applications
• Optional voltage selector configured for either
2 or 4 voltage selection
Power Inlet Filters & Power Entry Modules
Switch Option
S – DPST on/off switch
Omit for none
M Series
• Optional DPST on/off switch
• Included fuseholder accepts either single 3AG fuse
or dual metric fuses
• Snap-in or flange mounting styles
Filter Types
H Models provide a basic performance dual
element circuit EMI filter with minimal leakage
current, suitable for medical applications, with
attenuation similar to the EAH Series power inIet
filter.
F Models provide a basic performance dual
element circuit EMI filter, with attenuation similar
to the EEA Series Power Inlet Filter.
X Models provide a high performance three
element differential circuit filter, with extended
EMI attenuation similar to the X Series chassis
filter, suitable for bringing most digital equipment
(including switching power supplies) into compliance with FCC Part 15J, Class B conducted
emissions limits.
Z Models provide a premium performance three
element differential circuit filter, with enhanced
EMI low frequency attenuation similar to the P
Series Z models, suitable for bringing most digital
equipment (including switching power supplies)
into compliance with EN55022 Level B as well as
FCC Part 15J. For minimum panel footprint, see
the P series on page 192.
183
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Specifications
Accessories
Maximum leakage current each Line to Ground:
HM
FM
XM/ZM
@ 120 VAC 60 Hz:
2 A
.25 mA
.30 mA
@250 VAC 50 Hz:
5 A
.50 mA
.50 mA
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Hipot rating (one minute):
Line to Ground:
Line to Line:
Line to Load (switch off) non-filtered:
2250 VDC
1450 VDC
2500 VAC
Rated Voltage (max.):
250VAC
Operating Frequency:
50/60 Hz
Rated Current @ 120 VAC:
Rated Current @ 250 VAC:
3A models:
5A models:
6A Switched models:
6A non-switched models:
Required Fuse(s):
Switch:
MA100: Power interconnect assembly
For voltage select models. 8.5” wire leads
3 to 6A
2A
4A
5A
6A
Reversible fuseholder accepts
one .25 x 1.25” (not included)
or two 5 x 20mm (not included)
DPST
100,000 operations at 70A max. inrush
MA101: Plug only
MA102: Strip of 100 pins for use with MA101
MA104: Individual pins for use with MA101
MA302: Two Voltage Selection Card
Marked 120V/240V. One card comes standard with
every 2 voltage M series module
MA304: Four Voltage Selection Card
Marked 100V/120V/230V/240V. One card comes
standard with every 4 voltage M series module
Available Part Numbers
Non-Filtered Models
5EFM1S 5EFM1C 5EFM1SC
5EFM4S 5EFM4C 5EFM4SC
0
0
0
2
5EFM1
5EFM4
6VM4SC
1
1
1
4
6VM1SC
0
6VM1
6VM1S
6VM1C
6VM2
6VM2S
6VM4
6VM4S
6VM4C
General Purpose Filters
4
1
2
4
3
Snap-In
2
Flange Mount
2
Voltage
Selections
MA400: Medical safety bracket assembly
Prevents inadvertent removal of fuse(s)
Medical Filters
1
4
5EHM1
5EHM4
5EHM1S
5EHM4S
High Performance - FCC-B
1
4
3EXM4
3EXM1S
3EXM4S
Premium Performance - EN55022-B
1
4
3EZM4
MA401: Bracket only
MA402: Standoff only
3EZM1S
3EZM4S
184
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Accessories (continued)
Fuse Installation Instructions
MA601 - 604: Insulating Boot
Plastic shroud for back of M series to prevent
inadvertent access to connections
1. Remove power cord
2. Insert a pocket screwdriver at point “X” as shown
A
MA601: Fits M4S versions
MA602: Fits M1S versions
MA603: Fits M4 versions
MA604: First M1 versions
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
“X”
A
3
Section A-A
3. Gently lift the entire door UP approximately 1/4" (minimum)
Once lifted, the door will pivot on it’s hinges to expose
the fuse holder
Voltage Selection
Power Inlet Filters & Power Entry Modules
1. Open cover, using small blade screwdriver or
similar tool (see illustration on right)
Lift Up
2. Set aside cover/fuse block assembly
3. Pull voltage selector card straight out of housing,
using indicator pin
4. Orient selector card so that desired voltage is
readable at the bottom
4. When the fuse holder is installed in the single fuse position,
apply the screwdriver as shown and gently lift up
Use screwdriver as shown, do not use fingers
NOT here
5. Orient indicator pin to point up when desired
voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by
rotating the card 90° clockwise)
6. Insert voltage selector card into housing, printed
side of card facing forward toward IEC connector
and edge containing the desired voltage first
7. Replace cover, and verify that indicator pin shows
the desired voltage
Insert Here
When the fuse holder is installed in the dual fuse position,
it will normally release as soon as the door is opened
5. Install one (1) AG fuse or two (2) metric fuses (see below)
6. Replace fuse holder into housing
7. Swing and push to snap door back in place
4
0
0
0
2 3
2
0
1
1
0
2
120V
1
0
2
1
0
0
0
3
0
2
1
4
0
100V
3
0
230V
0
2 4
2
1 0
3
2
0
2
2
0
1
Fuse Options
2
4
0
240V
North American
single fuse installation
Metric
dual fuse installation
Install fuses on one side only, do not install
both AG and metric fuses at the same time
185
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Electrical Schematics
Non-Filtered Models
VM1
Neutral
Filtered Models
FM1 & HM1
Power On/Off
Note 3
Power On/Off
Note 2
K
Neutral
K
H
B
J
F
Note 1
Note 2
Note 3
120V
Hot
G
Phase
L
L
Customer
Transformer Primaries
VM2
FM4 & HM4
Power On/Off
Note 3
Neutral
G
240V
120V
H
K
Note 2
B
120V
100V
A
A
120V
B
Note 1
Neutral
C
C
D
Power On/Off
Note 2
Note 1
120V
J
L
Note 1
E
E
F
F
G
120V
100V
C
D
D
E
E
F
F
J
L
Phase
230V
240V
A
Note 4
G
120V
Customer
Transformer Primaries
Power On/Off
A
20V
100V
Hot
C
XM1 & ZM1
Power On/Off
Note 3
Neutral
Note 4
Note 3
F
VM4
20V
100V
B
120V
Customer Note 4
Transformer Primaries
A
A
H
K
D
120V
Hot
230V
240V
H
K
Note 2
Note 2
Neutral
H
B
J
F
Note 1
B
Note 1
J
L
Note 1
C
C
D
D
E
E
F
G
120V
F
Phase
G
Customer
Transformer Primaries
XM4 & ZM4










120V
100V
Power On/Off
Note 2
Neutral
A
A
20V
Note 4
H
K
100V
B
Note 1
Phase
J
L
Note 4




230V
240V
C
C
D
D
E
E
F
F
G
120V
Customer
Transformer Primaries



 
 
186
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Case Styles - Non-filtered Models
6VM1
USE ONLY WITH
250V FUSES
6VM2 & 6VM4
USE ONLY WITH
250V FUSES
C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
E
D
C
D
E
B
B
A
A




100V
120V
230V
240V




6VM1C








6VM4C
USE ONLY WITH
250V FUSES
USE ONLY WITH
250V FUSES
C
100V
120V
230V
240V
3
C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
E
Power Inlet Filters & Power Entry Modules
D
E
A
A








6VM1S


6VM2S & 6VM4S
USE ONLY WITH
250V FUSES
USE ONLY WITH
250V FUSES
C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
E
D
100V
120V
230V
240V
C
D
B
B
E
A
A








6VM1SC








6VM4SC
USE ONLY WITH
250V FUSES
USE ONLY WITH
250V FUSES
C
B
E
E
A
A



C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
100V
120V
230V
240V







187
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Case Styles - Filtered Models
3EXM1S & 3EZM1S
G
3EXM4S & 3EZM4S
G
Threaded
Insert
Threaded
Insert
1.17*
29.7
1.13*
28.7
1.88*
47.8
3.09
Max.
78.49
USE ONLY WITH
250V FUSES
1.88*
47.8
3.09
Max.
78.49
USE ONLY WITH
250V FUSES
C
DISCONNECT POWER
BEFORE REPLACING FUSES
C
D
D
E
E
B
B
*±.020 [.508]
A
*±.020 [.508]
A





100V
120V
230V
240V
DISCONNECT POWER
BEFORE REPLACING FUSES





3EXM4 & 3EZM4










5EHM1 & 5EFM1
G
Threaded
Insert
USE ONLY WITH
250V FUSES
C
DISCONNECT POWER
BEFORE REPLACING FUSES
1.13*
28.7
D
1.88*
47.8
3.09
Max.
78.49
USE ONLY WITH
250V FUSES
100V
120V
230V
240V
E
B
A
C
DISCONNECT POWER
BEFORE REPLACING FUSES
D
E
B
A
*±.020 [.508]


















188
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Case Styles - Filtered Models (continued)
5EFM1C
USE ONLY WITH
250V FUSES
5EHM4 & 5EFM4
USE ONLY WITH
250V FUSES
C
100V
120V
230V
240V
C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
A
E
D
E
B
A









5EHM1S & 5EFM1S




3
5EFM4C
C
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
E
D
100V
120V
230V
240V
C
D
A
B
Power Inlet Filters & Power Entry Modules
USE ONLY WITH
250V FUSES
E
A








5EFM1SC





5EHM4S & 5EFM4S
USE ONLY WITH
250V FUSES
USE ONLY WITH
250V FUSES
C
DISCONNECT POWER
BEFORE REPLACING FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
A
D
B
E
100V
120V
230V
240V
C
E
A













189
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Case Styles - Filtered Models (continued)
5EFM4SC
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
100V
120V
230V
240V
C
E


Recommended Panel Cutouts
Insert on XM and ZM
.170
models only Dia. 4.32
4S Models 1.17*
29.7
1.88*
47.8
1S & 4 models 1.13*
28.7
0.13 R
3.30
Dia.
.570
14.5
.170
4.32
.175
4.45

Part No.
F
B





*± .020 [.508]
1.145
29.08
A
B
C
F
G




E









 
 



 
 



 
 



 
 
 
 
 
 
 
 



 
 



 
 



 
 
























































































































6VM1C


6VM1S


6VM1SC


6VM2
6VM4


6VM4C


6VM2S
6VM4S


6VM4SC


3EXM1S
3EZM1S


3EXM4
3EZM4


3EXM4S
3EZM4S


5EHM1
5EFM1


5EFM1C


5EHM1S
5EFM1S


5EFM1SC


5EHM4
5EFM4


5EFM4C


5EHM4S
5EFM4S


5EFM4SC

6VM1
D
A



Case Dimensions


D






















190
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Slim Power Entry Module Family with Multiple Options
(continued)
M Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
5EHM
5EFM
3EXM
3EZM
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.1 .15
1
0
10
30
Frequency in MHz
0.1 .15
1
10
30
Frequency in MHz
0
10
0.1
1
0
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
3
Power Inlet Filters & Power Entry Modules
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Differential Mode / Symmetrical (Line to Line)
Common Mode / Asymmetrical (Line to Ground)

 
  
 





  
      

 


























































191
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com