Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options M Series UL Recognized CSA Certified VDE Approved XM / ZM VM Ordering Information 5EFM4SC Mounting Type C– Snap-In Omit for flange mount Voltage Selection Positions 1 or 4 M Series Filter Type F – General purpose H – Medical X – High performance Z – Premium performance V – Non-filtered Leakage current designation E – Low leakage (<0.5 mA) (Filtered models only) Current Rating @120 VAC 3, 5 or 6A • Family of slim power entry modules that consume minimal depth behind panel • Four compact modules each provide a different option combination 3 • Available non-filtered or with one of four filter circuits designed to meet a wide variety of applications • Optional voltage selector configured for either 2 or 4 voltage selection Power Inlet Filters & Power Entry Modules Switch Option S – DPST on/off switch Omit for none M Series • Optional DPST on/off switch • Included fuseholder accepts either single 3AG fuse or dual metric fuses • Snap-in or flange mounting styles Filter Types H Models provide a basic performance dual element circuit EMI filter with minimal leakage current, suitable for medical applications, with attenuation similar to the EAH Series power inIet filter. F Models provide a basic performance dual element circuit EMI filter, with attenuation similar to the EEA Series Power Inlet Filter. X Models provide a high performance three element differential circuit filter, with extended EMI attenuation similar to the X Series chassis filter, suitable for bringing most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits. Z Models provide a premium performance three element differential circuit filter, with enhanced EMI low frequency attenuation similar to the P Series Z models, suitable for bringing most digital equipment (including switching power supplies) into compliance with EN55022 Level B as well as FCC Part 15J. For minimum panel footprint, see the P series on page 192. 183 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Specifications Accessories Maximum leakage current each Line to Ground: HM FM XM/ZM @ 120 VAC 60 Hz: 2 A .25 mA .30 mA @250 VAC 50 Hz: 5 A .50 mA .50 mA GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Hipot rating (one minute): Line to Ground: Line to Line: Line to Load (switch off) non-filtered: 2250 VDC 1450 VDC 2500 VAC Rated Voltage (max.): 250VAC Operating Frequency: 50/60 Hz Rated Current @ 120 VAC: Rated Current @ 250 VAC: 3A models: 5A models: 6A Switched models: 6A non-switched models: Required Fuse(s): Switch: MA100: Power interconnect assembly For voltage select models. 8.5” wire leads 3 to 6A 2A 4A 5A 6A Reversible fuseholder accepts one .25 x 1.25” (not included) or two 5 x 20mm (not included) DPST 100,000 operations at 70A max. inrush MA101: Plug only MA102: Strip of 100 pins for use with MA101 MA104: Individual pins for use with MA101 MA302: Two Voltage Selection Card Marked 120V/240V. One card comes standard with every 2 voltage M series module MA304: Four Voltage Selection Card Marked 100V/120V/230V/240V. One card comes standard with every 4 voltage M series module Available Part Numbers Non-Filtered Models 5EFM1S 5EFM1C 5EFM1SC 5EFM4S 5EFM4C 5EFM4SC 0 0 0 2 5EFM1 5EFM4 6VM4SC 1 1 1 4 6VM1SC 0 6VM1 6VM1S 6VM1C 6VM2 6VM2S 6VM4 6VM4S 6VM4C General Purpose Filters 4 1 2 4 3 Snap-In 2 Flange Mount 2 Voltage Selections MA400: Medical safety bracket assembly Prevents inadvertent removal of fuse(s) Medical Filters 1 4 5EHM1 5EHM4 5EHM1S 5EHM4S High Performance - FCC-B 1 4 3EXM4 3EXM1S 3EXM4S Premium Performance - EN55022-B 1 4 3EZM4 MA401: Bracket only MA402: Standoff only 3EZM1S 3EZM4S 184 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Accessories (continued) Fuse Installation Instructions MA601 - 604: Insulating Boot Plastic shroud for back of M series to prevent inadvertent access to connections 1. Remove power cord 2. Insert a pocket screwdriver at point “X” as shown A MA601: Fits M4S versions MA602: Fits M1S versions MA603: Fits M4 versions MA604: First M1 versions USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES “X” A 3 Section A-A 3. Gently lift the entire door UP approximately 1/4" (minimum) Once lifted, the door will pivot on it’s hinges to expose the fuse holder Voltage Selection Power Inlet Filters & Power Entry Modules 1. Open cover, using small blade screwdriver or similar tool (see illustration on right) Lift Up 2. Set aside cover/fuse block assembly 3. Pull voltage selector card straight out of housing, using indicator pin 4. Orient selector card so that desired voltage is readable at the bottom 4. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently lift up Use screwdriver as shown, do not use fingers NOT here 5. Orient indicator pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by rotating the card 90° clockwise) 6. Insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first 7. Replace cover, and verify that indicator pin shows the desired voltage Insert Here When the fuse holder is installed in the dual fuse position, it will normally release as soon as the door is opened 5. Install one (1) AG fuse or two (2) metric fuses (see below) 6. Replace fuse holder into housing 7. Swing and push to snap door back in place 4 0 0 0 2 3 2 0 1 1 0 2 120V 1 0 2 1 0 0 0 3 0 2 1 4 0 100V 3 0 230V 0 2 4 2 1 0 3 2 0 2 2 0 1 Fuse Options 2 4 0 240V North American single fuse installation Metric dual fuse installation Install fuses on one side only, do not install both AG and metric fuses at the same time 185 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Electrical Schematics Non-Filtered Models VM1 Neutral Filtered Models FM1 & HM1 Power On/Off Note 3 Power On/Off Note 2 K Neutral K H B J F Note 1 Note 2 Note 3 120V Hot G Phase L L Customer Transformer Primaries VM2 FM4 & HM4 Power On/Off Note 3 Neutral G 240V 120V H K Note 2 B 120V 100V A A 120V B Note 1 Neutral C C D Power On/Off Note 2 Note 1 120V J L Note 1 E E F F G 120V 100V C D D E E F F J L Phase 230V 240V A Note 4 G 120V Customer Transformer Primaries Power On/Off A 20V 100V Hot C XM1 & ZM1 Power On/Off Note 3 Neutral Note 4 Note 3 F VM4 20V 100V B 120V Customer Note 4 Transformer Primaries A A H K D 120V Hot 230V 240V H K Note 2 Note 2 Neutral H B J F Note 1 B Note 1 J L Note 1 C C D D E E F G 120V F Phase G Customer Transformer Primaries XM4 & ZM4 120V 100V Power On/Off Note 2 Neutral A A 20V Note 4 H K 100V B Note 1 Phase J L Note 4 230V 240V C C D D E E F F G 120V Customer Transformer Primaries 186 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Non-filtered Models 6VM1 USE ONLY WITH 250V FUSES 6VM2 & 6VM4 USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D C D E B B A A 100V 120V 230V 240V 6VM1C 6VM4C USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C 100V 120V 230V 240V 3 C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D E Power Inlet Filters & Power Entry Modules D E A A 6VM1S 6VM2S & 6VM4S USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D 100V 120V 230V 240V C D B B E A A 6VM1SC 6VM4SC USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C B E E A A C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D 100V 120V 230V 240V 187 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models 3EXM1S & 3EZM1S G 3EXM4S & 3EZM4S G Threaded Insert Threaded Insert 1.17* 29.7 1.13* 28.7 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES C D D E E B B *±.020 [.508] A *±.020 [.508] A 100V 120V 230V 240V DISCONNECT POWER BEFORE REPLACING FUSES 3EXM4 & 3EZM4 5EHM1 & 5EFM1 G Threaded Insert USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES 1.13* 28.7 D 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES 100V 120V 230V 240V E B A C DISCONNECT POWER BEFORE REPLACING FUSES D E B A *±.020 [.508] 188 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models (continued) 5EFM1C USE ONLY WITH 250V FUSES 5EHM4 & 5EFM4 USE ONLY WITH 250V FUSES C 100V 120V 230V 240V C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D A E D E B A 5EHM1S & 5EFM1S 3 5EFM4C C USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D 100V 120V 230V 240V C D A B Power Inlet Filters & Power Entry Modules USE ONLY WITH 250V FUSES E A 5EFM1SC 5EHM4S & 5EFM4S USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D A D B E 100V 120V 230V 240V C E A 189 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models (continued) 5EFM4SC USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES 100V 120V 230V 240V C E Recommended Panel Cutouts Insert on XM and ZM .170 models only Dia. 4.32 4S Models 1.17* 29.7 1.88* 47.8 1S & 4 models 1.13* 28.7 0.13 R 3.30 Dia. .570 14.5 .170 4.32 .175 4.45 Part No. F B *± .020 [.508] 1.145 29.08 A B C F G E 6VM1C 6VM1S 6VM1SC 6VM2 6VM4 6VM4C 6VM2S 6VM4S 6VM4SC 3EXM1S 3EZM1S 3EXM4 3EZM4 3EXM4S 3EZM4S 5EHM1 5EFM1 5EFM1C 5EHM1S 5EFM1S 5EFM1SC 5EHM4 5EFM4 5EFM4C 5EHM4S 5EFM4S 5EFM4SC 6VM1 D A Case Dimensions D 190 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 5EHM 5EFM 3EXM 3EZM db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 .15 1 0 10 30 Frequency in MHz 0.1 .15 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 3 Power Inlet Filters & Power Entry Modules Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 191 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com