OMRON SR107AD01

SR107AD, SR108AD and SR109AD
R
C
US
Conforms to EN60204-1, EN954-1, EN292, VDE 0113-1
UL and C-UL listed, BG approved
safety monitoring relays
H
SR107AD, SR108AD and SR109AD
Dual Channel Safety Monitoring Relay
■
■
■
Power requirements—the
SR107AD, SR108AD and
SR109AD will accept
24 VAC/DC
Inputs—the SR107AD,
SR108AD and SR109AD
will accept single or dual N/C
inputs or dual PNP solid-state
inputs from a light curtain (see
SR102AM for application wiring
for a light curtain)
Outputs—the SR107AD,
SR108AD and SR109AD have a
total of 4 N/O outputs with 3, 2
or 1 of the outputs with a time
delay of 1-30 sec.
■
■
External Device Monitoring
(EDM) is provided with a N/C
loop between S12 and S21 on
the SR107AD, SR108AD and
SR109AD
Reset mode—a monitored
manual start or an auto/manual
start may be configured with
the SR107AD, SR108AD and
SR109AD. Monitored manual
reset requires closure of the
reset circuit followed by opening
of the circuit. Reset occurs when
circuit is opened. Auto reset
requires only closure of the reset
circuit as reset occurs when
circuit is closed.
■
PLC Compatible—The N/O
off delayed outputs make it
possible to use the SR107AD,
SR108AD and SR109AD on
machines with Programmable
Logic Controllers that require
some time to execute an orderly
shutdown
A
Go to the Engineering Guide
For in-depth information on
safety standards and use.
SR107AD, SR108AD and SR109AD
■
Application
✎
24VAC/DC, 110VAC, 230VAC
See the SR102AM for
wiring to a light curtain
K1 (AUX)
START
MOMENTARY
PUSH
BUTTON
EB SERIES
LATCHING
E-STOP
BUTTON
GUARD
CLOSED
A1
11
21
S11
22
34
S12
Sr108
Pin Assignment
U B A1 A2
12
STOP
MOMENTARY
PUSH
BUTTON
S14
13
23
RESET
37
l1
n
timer
K2
CONTACT
PROTECTION
E.G. THERMAL
CUT OUT
K1
K3
T5009
INTERLOCK
SWITCH
K2
K4
S10
S13
14
24
FUSE
FUSE
K1
38
K2
Terminal Connections and Output Contact Arrangements
Sr109AD
A1
S11
S14
S21
S12
S13
S10
A2
14
24
34
48
14
24
38
48
S12
S13
S10
A2
S12
S13
S10
A2
A1
S11
S14
S21
A1
S11
S14
S21
13
27
37
47
13
23
37
47
13
23
33
47
Sr108AD
13
27
37
47
13
23
37
47
13
23
33
47
14
28
38
48
14
24
38
48
14
24
34
48
48
m
H
safety monitoring relays
A2
14
28
38
48
MOMENTARY
PUSH
BUTTON
K1
Dc +U B 0V
Ac
Sr107AD
47
relay control and
fault monitoring
Power supply
(S11 = 24 V)
33
S21
L1 L2 L3
K2 (AUX)
SR107AD, SR108AD and SR109AD
■
Block Diagram
A1
S11
S21
S12
S14
13
23
37
47
14
24
38
48
relay control and
fault monitoring
Power supply
(S11 = 24 V)
Sr108
Pin Assignment
UB
A1
A2
Dc
+U B
0V
Ac
l1
n
timer
K1
K3
K2
K4
A2
S10
S13
safety monitoring relays
H
■
Dimensions — mm/in.
Suitable for 35mm Din rail
acc. to Din en 50022-35
99
3.9
114
4.49
22.5
0.885
A
Go to the Engineering Guide
For in-depth information on
safety standards and use.
SR107AD, SR108AD and SR109AD
■
Specifications
Electrical
All Models
Power Supply:
±10%, 50-60 Hz, 24 VAC/DC
Power Consumption:
4.6 W
Safety Inputs:
1 N/C or 2 N/C
Max Input Resistance:
800 Ohms per channel
Outputs:
Auxiliary Outputs:
SR107AD
1 N/O + 3 N/O delayed
SR108AD
SR109AD
2 N/O + 2 N/O delayed
3 N/O + 1 N/O delayed
None
Max Switched AC:
Inductive AC-15, 3 A/250 VAC; Resistive AC-12, 8 A/250 V
Max Switched DC:
Inductive DC-13, 3 A/24 VDC; Resistive DC-12, 8 A/50 V
Min Switched Current/Voltage:
10 mA/24 V
Impulse Withstand Voltage:
2500 V
Max Drop-Out Time:
10 ms (75 ms by removing supply voltage)
Max Output Fuse:
8 A quick-acting fuse or 6 A slow-acting fuse
Start Mode:
Monitored manual (S11-S21) or auto/manual (S12-S21)
External Device Monitoring (EDM):
N/C loop between S12 and S21
Mechanical
Mounting: 35 mm (1.38 in.) DIN rail
Case Material: Polyamide PA6.6
H
1 x 2.5 mm2 (14 AWG) stranded
Weight: 250 g (8.8 oz.)
Color: Red
External Switches:
Output delay adjustment (1 to 30 sec.)
Indication: 4, status displays for relays K1 to K4
Mechanical Life:
safety monitoring relays
Max Wire Size: 1 x 106 operations
Environmental
Enclosure Protection: IP20 terminals, IP40 (NEMA 1) housing
Operating Temperature: -15 to 40°C (-5 to 140°F)
Humidity: 93% RH at 104°C (219°F)
Compliance
Standards:
EN60204-1, EN954-1, VDE 0113 part 1
Approvals/Listings:
CE-marked for all applicable directives, UL and C-UL, BG
Safety Category:
Cat. 4 per EN954-1 (SR107, SR108, SR109 internal operation)
Specifications are subject to change without notice.
Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the guard closed, actuator in place, and the
machine able to be started.
■
Ordering
Delayed Outputs
Part No.
SR107AD01
Model
24 VAC/DC
Supply InputsImmediate Outputs
2 N/C
1 N/O
3 N/O
44510-1071
SR108AD01
24 VAC/DC
2 N/C
2 N/O
2 N/O
44510-1081
SR109AD01
24 VAC/DC
2 N/C
3 N/O
1 N/O
44510-1091