OMRON SS5GL-13F

Snap Action Switch
SS
Subminiature Snap Action Switch
• Economical, subminiature snap action switch offers long
service life (30 million operations minimum)
• All models are free from overtravel restrictions, permit easy
setting
• Wide switching capacity range from microvoltage/current
loads (1 mA at 5 VDC to high-capacity loads 10.1 A at 250
VAC)
• Standard operating force, low force or super-low force
models available
• RoHS Compliant
Ordering Information
Rating
Actuator
0.1 A
Pin plunger
Hinge lever
Simulated roller
lever
Hinged roller
lever
5A
Pin plunger
Hinge lever
10 A
Contact
OF
Straight
PCB terminal
Left-angled
Right-angled
Soldered
terminal
Tab (#110)
terminal
25 g
SS-01-ED
—
—
SS-01-E
SS-01-ET
50 g
SS-01-FD
—
—
SS-01-F
SS-01-FT
150 g
SS-01D
SS-01D1
SS-01D2
SS-01
SS-01T
8g
SS-01GL-ED
—
—
SS-01GL-E
SS-01GL-ET
16 g
SS-01GL-FD
—
—
SS-01GL-F
SS-01GL-FT
50 g
SS-01GLD
SS-01GLD1
SS-01GLD2
SS-01GL
SS-01GLT
8g
SS-01GL13-ED
—
—
SS-01GL13-E
SS-01GL13-ET
16 g
SS-01GL13-FD
—
—
SS-01GL13-F
SS-01GL13-FT
50 g
SS-01GL13D
—
—
SS-01GL13
SS-01GL13T
8g
SS-01GL2-ED
—
—
SS-01GL2-E
SS-01GL2-ET
16 g
SS-01GL2-FD
—
—
SS-01GL2-F
SS-01GL2-FT
50 g
SS-01GL2D
—
—
SS-01GL2
SS-01GL2T
50 g
SS-5-FD
SS-5-FD1
SS-5-FD2
SS-5-F
SS-5-FT
150 g
SS-5D
SS-5D1
SS-5D2
SS-5
SS-5T
16 g
SS-5GL-FD
SS-5GL-FD1
SS-5GL-FD2
SS-5GL-F
SS-5GL-FT
50 g
SS-5GLD
SS-5GLD1
SS-5GLD2
SS-5GL
SS-5GLT
Simulated roller
lever
16 g
SS-5GL13-FD
—
SS-5GL13-FD2
SS-5GL13-F
SS-5GL13-FT
50 g
SS-5GL13D
SS-5GL13D1
SS-5GL13D2
SS-5GL13
SS-5GL13T
Hinge roller
lever
16 g
SS-5GL2-FD
SS-5GL2-FD1
SS-5GL2-FD2
SS-5GL2-F
SS-5GL2-FT
50 g
SS-5GL2D
SS-5GL2D1
SS-5GL2D2
SS-5GL2
SS-5GL2T
150 g
SS-10D
—
—
SS-10
SS-10T
50 g
SS-10GLD
—
—
SS-10GL
SS-10GLT
Simulated roller
lever
50 g
SS-10GL13D
—
—
SS-10GL13
SS-10GL13T
Hinge roller
lever
50 g
SS-10GL2D
—
—
SS-10GL2
SS-10GL2T
Pin plunger
Hinge lever
Snap Action Switch
SS
95
Model Number Legend
SS1 2 3 4 5
1.
Ratings
10:
10.1 A at 125 VAC
5:
5 A at 125 VAC
01:
0.1 A at 30 VDC
3.
Maximum Operating Force (see note)
None: 150 gf
-F:
50 gf (0.1A and 5A versions)
-E:
25 gf (0.1A versions)
2.
Actuator
None: Pin plunger
GL:
Hinge lever
GL13: Simulated roller lever
GL2: Hinge roller lever
4.
Contact Form
None: SPDT
-2:
SPST-NC
-3:
SPST-NO
5.
Terminals
None: Solder terminals
T:
Quick-connect terminals (#110)
D:
Straight PCB terminals
D1:
Left-angled PCB terminals
D2:
Right-angled PCB terminals
Note: These OF values are for the pin plunger models.
Consult Omron regarding the following:
- SPST-NC and SPST-NO versions
- High temperature versions that are rated from -25°C to 120°C
- Left and Right angled PCB terminal versions
Specifications
■ Characteristics
Operating speed
0.1 mm to 1 m/second (pin plunger models)
Operating frequency
Mechanical: 400 operations per minute max.
Electrical: 30 operations per minute max.
Insulation resistance
100 MΩ at 500 VDC
Contact resistance
150 gf:
50 gf:
25 gf:
SS-10, SS-5 models:
30 mΩ max.
SS-01 models:
50 mΩ max.
SS-5 models:
50 mΩ max.
SS-01 models
100 mΩ max.
SS-01 models
150 mΩ max.
Dielectric strength (See note 2)
1,000 VAC (600 VAC for SS-01), 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground and between each
terminal and noncurrent-carrying metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (see note 3)
150 gf:
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction: 300 m/s2 (approx. 30G) max.
50 gf and 25gf:
Destruction: 500 m/s2 (approx. 50G) max.
Malfunction: 200 m/s2 (approx. 20G) max.
Degree of protection
IEC IP40
Degree of protection against
electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25° to 85°C (at 60% RH max.) with no icing
Ambient operating humidity
85% max. (for 5°C to 35°C)
Service life
Mechanical:
30 million operations min. at 60 operations per minute (SS-01, SS-5)
10 million operations min. at 60 operations per minute (SS-10)
Electrical:
200,000 operations min. at 30 operations per minute (SS-01, SS-5)
50,000 operations min. at 30 operations per minute (SS-10)
Weight
Approx. 1.6 g pin plunger type
Note: 1. Data shown are of initial value.
2. The dielectric strength values shown is measured using a separator between the switch and metal mounting plate.
3. For pin plunger models, the above value apply for use at the free position and total travel position. For the lever models, the values apply
at the total travel position.
96
Snap Action Switch
SS
■ Ratings (reference values)
Switch series:
SS-10 and SS-5
Resistive load
Contact form
NO
SS-01
Inductive load
NC
NC
NO
0.7 A
250 VAC
3 A (10.1A)
1A
8 VDC
5 A (10.1A)
14 VDC
5 A (10.1A)
2A
4A
3A
0.1 A
30 VDC
4A
2A
3A
3A
0.1 A
125 VDC
0.4 A
0.05 A
0.4 A
0.05 A
---
250 VDC
0.2 A
0.03 A
0.2 A
0.03 A
---
3A
0.5 A
2A
5A
NC
NO
2.5 A
1.3 A
Resistive Load
1.5 A
2A
NO
Motor load
5 A (10.1A)
125 VAC
NC
Lamp load
1.5 A
4A
NC
NO
0.1 A
0.8 A
---
3A
0.1 A
Note: 1. Data in parentheses apply to the SS-10 models only.
2. The above current ratings are the values of the steady-state current.
3. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). The inductive load rating of the SS-10 is the
same as that of SS-5.
4. Lamp load has an inrush current of 10 times the steady-state current
5. Motor load has an inrush current of 6 times the steady-state current.
6. If the switch is used in a DC circuit and is subjected to inrush current or surge, connect a surge suppressor across the switch.
7. The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/minute
■ Approved Standards
■ Contact Specifications
UL Recognized (File No. E41515)
CSA Certified (File No. LR21642)
Rated Voltage
SS-10
SS-5
SS-01
125 VAC
---
5A
0.1 A
250 VAC
10.1 A
3A
---
30 VDC
---
---
0.1 A
EN61058-1 - - VDE approval
(File No. 129246 for SS-5, 125256 for SS-10)
Rated Voltage
SS-10
SS-5
250 VAC
10.1 A
5A
EN61058-1 - - TÜV Rheinland approval
(File No. J9451450)
Rated Voltage
SS-10
SS-5
250 VAC
10.1 A
5A
Item
SS-10
SS-5
SS-01
Specification
Rivet
Crossbar
Material
Silver alloy
Silver
Gold alloy
Gap (standard value)
0.5 mm
0.25 mm
Inrush current
NC: 20A max. NC: 20A max.
1A max.
NO: 15A max. NO: 10A max.
Minimum applicable
160 mA at 5 VDC
1 mA at 5 VDC
load (see note)
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60%
(λ60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C)
Note: The rated values approved by each of the safety standards
(e.g. UL, CSA) may be different from the performance characteristics individually defined in this catalog.
Snap Action Switch
SS
97
Engineering Data
■ Mechanical Service Life
■ Electrical Service Life
SS-5 Models
SS-01, SS-5 Models
(Pin Plunger Models)
(Pin Plunger Models)
40,000
Number of operations (x10 3)
Number of operations (x10 3)
5,000
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Without load
Operating frequency: 60 operations/min
30,000
20,000
10,000
5,000
3,000
1,000
0.2
0.3
0.4
0.5
0.6
0.7
300
250 VAC
100
50
30
0
1
2
3
4
5
6
7
Switching current (A)
Overtravel (mm)
■ Mounting
125 VAC
500
10
0.1
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
cosφ = 1
■ Contact Form
Panel Mounting
SPST-NC
SPDT
SPST-NO
All switches may be panel mounted using M2.3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.23 to 0.26 N·m.
Two, 2.4-dia. mounting holes or
M2.3 screw holes
COM
PCB Layout
Three, 1.35 to 1.5 dia.
+0.15
8.8 –0.05
16.1±0.1
98
COM
NC
COM
NO
* Consult Omron for SPST-NC and SPST-NO contact form types
ordering information.
9.5 ± 0.1
(1.6)
NO NC
Snap Action Switch
SS
Dimensions
■ Terminals
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Terminal plate thickness is 0.5 mm for all models.
Quick-connect Terminals (#110)
Solder Terminals
2.9
PCB Terminals
2.9
2.9
6.4
7.1
8.8
COM
terminal
(C)
1.6
3.2
1.6
6.4
9.5±0.1
8.8
Three,
1.6-dia. holes
19.8
8.8
2.8
1.6
7.3
7.3
3.2
9.5±0.1
19.8
COM terminal (C)
NO terminal
NC terminal
0.6
3.3
10.6
Three, 1.2 dia.
COM
terminal
(C)
7.0
0.5
7.3
1.2
9.5±0.1
3.2
19.8
NO terminal
t = 0.5
NC terminal
NO terminal
NC terminal
Note: Terminal plate thickness is 0.5 mm for all models.
PCB, Right-angled terminal
PCB, Left-angled terminal
Note: Angled terminal directions
are shown below.
Left-angled terminal
COM
terminal
Right-angled terminal
COM
terminal
NC
terminal
NC terminal
NO terminal
NO terminal
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and dimensions are for solder terminal models.
Refer to “Terminals” for models with quick-connect terminals (#110) or PCB terminals.
3. The operating characteristics are for operation in the A direction( )
Pin Plunger Models
7.5
PT
SS-01(-E, -F)
SS-5(-F)
SS-10
3.2
2
A
+0.075
OP
6.4
2.9
2.35 –0.05
9.5 10.2
2.5
6.4
2.5±0.07 dia.
1.6
Characteristics
OF max.
RF min.
PT max.
OT min.
MD max.
OP
SS-01-E
25 g
2g
0.5 mm
0.5 mm
0.1 mm
2.35 +0.075
–0.05 dia. holes
8.8
7.3
5.1 9.5±0.1
19.8
3.2
6.4
Part number
SS-01-F, SS-5-F
SS-01, SS-5
50 g
150 g
4g
25 g
0.5 m
0.5 mm
0.5 mm
0.5 mm
0.1 mm
0.1 mm
8.4 ± 0.5 mm
Three, 1.6 dia.
SS-10
150 g
25 g
0.6 mm
0.4 mm
0.12 mm
Snap Action Switch
SS
99
Hinge Lever Models
t = 0.3
(see note 1)
SS-01GL(-E, -F)
SS-5GL(-F)
SS-10GL
14.5 (see note 2) A
+0.075
FP
OP
2.35 –0.05
9.5 10.2
2.5
2.9
6.4
+0.075
2.5±0.07 dia.
1.6
Note:
3.6
2.35 –0.05 dia. holes
Three, 1.6 dia.
3.2
6.4
8.8
7.3
5.1 9.5±0.1
19.8
1. Stainless-steel lever
2. Besides the SS- GL models with a hinge lever length of 14.5, the SS- GL11 models with a hinge lever length of 18.5, the
SS- GL111 models with a hinge lever length of 22.6, and the SS- GL1111 models with a hinge lever length of 37.8 are available.
Contact your OMRON representative for these models
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
SS-01GL-E
8g
1g
1.2 mm
0.8 mm
SS-01GL-F, SS-5GL-F
SS-01GL, SS-5GL
16 g
50 g
2g
6g
1.2 mm
1.2 mm
0.8 mm
0.8 mm
13.6 mm
8.8 ± 0.8 mm
Simulated Roller Lever Models
15.8
t = 0.3
(see note)
SS-01GL13(-E, -F)
SS-5GL13(-F)
SS-10GL13
A 1.3R
3.6
OP
+0.075
2.35 –0.05
6.4
2.35 +0.075
–0.05
2.5±0.07 dia.
1.6
8.8
SS-10GL13-E
8g
1g
1.2 mm
0.8 mm
dia. holes
7.3
5.1 9.5±0.1
19.8
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
FP
9.5 10.2
2.5
2.9
SS-10GL
50 g
6g
1.0 mm
1.0 mm
Note:
3.2
6.4
Three, 1.6 dia.
Stainless-steel spring lever
SS-10GL13-F, SS-5GL13-F
SS-01GL13, SS-5GL13
16 g
50 g
2g
6g
1.2 mm
1.2 mm
0.8 mm
0.8 mm
15.5 mm
10.7±0.8 mm
Hinge Roller Lever Models
14.5
SS-01GL2(-E, -F)
SS-5GL2(-F)
SS-10GL2
SS-10GL13
50 g
6g
1.0 mm
1.0 mm
4.8 dia. × 3.2
(see note 2)
A
t = 0.3
(see note 1)
OP
FP
+0.075
2.35 –0.05 dia.
2.9
9.5 10.2
2.5
6.4
2.5±0.07 dia.
1.6
+0.075
2.35 –0.05
8.8
5.1 9.5±0.1
19.8
dia. holes
7.3
Note:
3.2
6.4
Three, 1.6 dia.
1. Stainless-steel spring lever
2. Polyacetal resin roller
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
100
SS-01GL2-E
8g
1g
1.2 mm
0.8 mm
Snap Action Switch
SS
SS-01GL2-F, SS-5GL2-F
SS-01GL2, SS-5GL2
16 g
50 g
2g
6g
1.2 m
1.2 mm
0.8 mm
0.8 mm
19.3 mm
14.5 ± 0.8 mm
SS-10GL2
50 g
6g
1.0 mm
1.0 mm
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
■ Cautions
Mounting
Handling
Mount the switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the switch, resulting in faulty operation or
breakage in the housing.
Turn OFF the power supply before mounting or removing the switch,
wiring, or performing maintenance for inspection. Failure to do so
may result in electric shock or burning
Operating Stroke
Terminal Connection
Take particular care in setting the operating stroke for the pin plunger
models. Make sure that the operating stroke is 70% to 100% of the
rated OT distance. Do not operate the actuator exceeding the OT distance, otherwise the life expectancy of the switch may be shortened.
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and then solder.
Using Microloads
Voltage (V)
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
Make sure that the capacity of the soldering iron is 60 W maximum.
Do not take more than 5 seconds to solder the switch terminal.
Improper soldering involving an excessively high temperature or
excessive soldering time may deteriorate the characteristics of the
switch.
Be sure to apply only the minimum required amount of flux. The
switch may have contact failures if flux intrudes in the interior of the
switch.
Use the following lead wires to connect to the solder terminals;
30
26mA 100mA
0.16mA
24
Operating range
for micro load
models SS-01
Operating
range for
general-load
models
SS-5, SS-10
12
Inoperable
range
5
1mA
100mA 160mA
Model
Conductor size
SS-5
0.5 to 0.75 mm2
SS-10
0.75 mm2
If the PCB terminal models are soldered in a solder bath, flux will permeate inside the switch and cause contact failure. Therefore, manually solder the PCB terminal.
Wire the quick-connect terminals (#110) with receptacles. Insert the
terminals straight into the receptacles. Do not impose excessive
force on the terminal in the horizontal direction, otherwise the terminal may be deformed or the housing may be damaged.
Insulation Distance
0
1
10
100
1,000
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
Use a separator between the switch and metal mounting panels, to
ensure proper dielectric characteristics are achieved.
According to EN61058-1, the minimum insulation thickness for this
switch should be 1.1 mm and minimum clearance distance between
the terminal and mounting plate should be 1.6 mm. If the insulation
distance cannot be provided in the product incorporating the switch,
either use a switch with insulation barrier or use a separator to
ensure sufficient insulation distance.
Separator
Snap Action Switch
SS
101
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X303-E-1
11/10
Snap Action Switch
SS
Specifications subject to change without notice
Printed in USA