TSC TSH282

TSH282
Sensitivity Unipolar Hall Effect Switch
TO-92S
Pin Definition:
1. VCC
2. GND
3. Output
SOT-23
Pin Definition:
1. VCC
2. Output
3. GND
Description
TSH282 is an unipolar Hall effect sensor IC. It incorporates advanced chopper stabilization technology to provide
accurate and stable magnetic switch points. The design, specifications and performance have been optimized for
applications of solid state switches. The output transistor will be switched on (BOP) in the presence of a sufficiently
strong South pole magnetic field facing the marked side of the package. Similarly, the output will be switched off
(BRP) in the presence of a weaker South field and remain off with “0” field.
Features
●
●
●
●
●
●
CMOS Hall IC Technology
Solid-State Reliability
Chopper stabilized amplifier stage
Unipolar, output switches with absolute value of
South pole from magnet
Operation down to 3.0V
High Sensitivity for direct reed switch replacement
applications
Ordering Information
Part No.
TSH282CT B0G
TSH282CX RFG
Package
Packing
TO-92S
SOT-23
1Kpcs / Bulk Bag
3Kpcs / 7” Reel
Note: “G” denote for Halogen Free Product
Application
●
●
●
●
●
Solid state switch
Limit switch, Current limit
Interrupter
Current sensing
Magnet proximity sensor for reed switch
replacement
Absolute Maximum Rating (Ta = 25oC unless otherwise noted)
Characteristics
Limit
Value
Unit
Supply voltage
Output Voltage
Reverse voltage
Magnetic flux density
Output current
Operating Temperature Range
VCC
VOUT
VCC/OUT
27
27
-0.3
Unlimited
50
V
V
V
Gauss
mA
o
C
IOUT
TOPR
-40 to +85
o
-55 to +150
Storage temperature range
TSTG
C
o
150
Maximum Junction Temp
TJ
C
206
TO-92S
o
Thermal Resistance - Junction to Ambient
θJA
C/W
543
SOT-23
148
TO-92S
o
Thermal Resistance - Junction to Case
θJC
C/W
410
SOT-23
606
TO-92S
Package Power Dissipation
PD
mW
230
SOT-23
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximumrated conditions for extended periods may affect device reliability.
1/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
Block Diagram
Note: Static sensitive device; please observe ESD precautions. Reverse VDD protection is not included. For
reverse voltage protection, a 100Ω resistor in series with VDD is recommended.
Typical Application Circuit
D1:1N4148 or 100Ω
C1:1000pF
C2:15pF
R1:10KΩ
Electrical Specifications (DC Operating Parameters:TA=+25oC,VCC=12V)
Parameters
Test Conditions
Min
Typ
Max
Units
3.0
--
24
V
Supply Voltage
Operating
Supply Current
B<BOP
--
2.5
5.0
mA
Output Low Voltage
IOUT = 20mA, B>BOP
--
--
500
mV
Output Leakage Current
IOFF B<BRP, VOUT = 20V
--
--
10
uA
Output Rise Time
RL=1kΩ, CL =20pF
--
0.04
--
uS
Output Fall Time
RL=1kΩ; CL =20pF
--
0.18
--
uS
2/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
Magnetic Specifications
o
DC Operating Parameters: TA=+25 C, VDD=12V
Parameter
Symbol
Operate Point
Test condition
Min
Typ
Max
Unit
BOP
45
--
100
Gauss
Release Point
BRP
25
--
70
Gauss
Hysteresis
BHYS
--
20
--
Gauss
Note: 1G (Gauss) = 0.1mT (millitesta)
Output Behavior versus Magnetic Pole
o
DC Operating Parameters Ta = -40 to 125 C, VDD = 3.0 ~ 24V
Parameter
Test condition
OUT(TO-92S)
OUT(SOT-23)
South pole
B>Bop[(100)~(45)]
Low
Open(Pull-up Voltage)
Null or weak magnetic field
-Brp ~ +Brp
Open(Pull-up Voltage)
Open(Pull-up Voltage)
North pole
B< -Bop(-25~-70)
Open(Pull-up Voltage)
Low
SOT-23 (North Pole)
TO-92S (South Pole)
OUT=Low
(VDSon)
OUT=Low
(VDSon)
3/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
Characteristic Performance
Figure 1. Supply Voltage vs. Flux Density
Figure 2. Temperature vs. Flux Density
Figure 3. Supply Current vs. Temperature
Figure 4. Supply Current vs. Supply Voltage
Figure 5. Output Saturation Voltage vs.
Supply Voltage
Figure 6. Output Saturation Voltage vs.
Temperature
4/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
Characteristic Performance
Figure 7. Output Leakage Current vs.
Supply Voltage
Figure 8. Power Dissipation vs. Temperature
5/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
TO-92S Mechanical Drawing
Unit: Millimeters
Marking Diagram
282
Y
WW
= Device Code
= Year Code (3=2013, 4=2014….)
= Week Code (01~52)
6/8
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
SOT-23 Mechanical Drawing
Unit: Millimeters
Marking Diagram
282
WW
= Device Code
= Week Code Table
week
code
week
code
week
code
week
code
1
OA
14
ON
27
PA
40
PN
2
OB
15
OO
28
PB
41
PO
3
OC
16
OP
29
PC
42
PP
4
OD
17
OQ
30
PD
43
PQ
7/8
5
OE
18
OR
31
PE
44
PR
6
OF
19
OS
32
PF
45
PS
7
OG
20
OT
33
PG
46
PT
8
OH
21
OU
34
PH
47
PU
9
OI
22
OV
35
PI
48
PV
10
OJ
23
OW
36
PJ
49
PW
11
OK
24
OX
37
PK
50
PX
12
OL
25
OY
38
PL
51
PY
13
OM
26
OZ
39
PM
52
PZ
Version: B13
TSH282
Sensitivity Unipolar Hall Effect Switch
Notice
Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf,
assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, to
any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of
sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty,
relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose,
merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify TSC for any damages resulting from such improper use or sale.
8/8
Version: B13